Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

CO 2 Laser Sintering of Garnet-Type Solid-State Electrolytes

We report the processing of garnet-type solid-state electrolytes remains challenging as densification conventionally requires high sintering temperatures and long processing times, which can result in severe Li loss, the formation of secondary phases, and thus high porosity and low ionic conductivity. Here, we report an ultrafast sintering method based on CO 2 laser scanning with the assistance of a heating stage. We demonstrate the rapid densification of low-packing-density Li 6.4 La 3 Zr 1.4 Ta 0.6 O 12 (LLZTO) films, which are difficult to densify by conventional furnace sintering methods. This unique approach has three fingerprint characteristics: (1) mitigation of Li loss through ultrafast sintering (dwelling time $\ll$1 s); (2) a unique anisotropic shrinkage behavior that greatly reduces film thickness; (3) wave-like surface topology from point scanning strategy that enables 3D interfacial contacts with electrode materials. Herein, highly dense (95.68%) and highly conductive (0.26 mS·cm –1 at 25 °C) LLZTO films are obtained through CO2 laser sintering. This work provides a unique, scalable, and widely applicable ultrarapid laser sintering technique to overcome the difficulties associated with classic methods for the integration of SSEs for practical all-solid-state Li-metal battery applications.

36 MATERIALS SCIENCE↗

A review of long fibre thermoplastic (LFT) composites [A review of long fibre-reinforced thermoplastic of long fibre thermoplastic (LFT) composites]

Long fibre-reinforced thermoplastic or long fibre thermoplastic (LFT) composites possess superior specific modulus and strength, excellent impact resistance, and other advantages such as ease of processability, recyclability, and excellent corrosion resistance. These advantages make LFT composites one of the most advanced lightweight engineering materials and enable their increasing use in various applications. This review paper summarizes the research and development work that has been conducted on LFT composites since their initial development. Different aspects of LFTs, such as process development, fibre orientation distribution (FOD), fibre length distribution (FLD), and their effects on the mechanical properties of LFT composites are described. The characterization of the FOD and FLD in the LFT composites using advanced imaging technology such as high-resolution 3D micro-CT scanning technique is summarized. Research and development of LFT hybridisation and LFT additives are also discussed. Lastly, conclusions are made and the future outlook of LFT composites is given.

36 MATERIALS SCIENCE↗

Atom probe datasets from neutron irradiated Fe-Cr alloys

A series of model Fe–Cr alloys containing 3–18 at.% Cr was neutron irradiated at a nominal temperature of 563 K to 1.82 dpa. Solute distributions were analyzed by atom probe tomography, which revealed α′ precipitation for alloys containing more than 9 at.% Cr. Both the Cr concentration dependence of α′ precipitation and the measured matrix compositions are in agreement with the recently published Fe–Cr phase diagrams. An irradiation-accelerated precipitation process is strongly suggested. Irradiation was carried out in the Advance Test Reactor (ATR) at Idaho National Laboratory. A series of six Fe–Cr alloys of nominal compositions 3, 6, 9, 12, 15 and 18 at.% Cr was irradiated at a neutron fluence (E > 1 MeV) of 1.1 × 1021 n cm−2 at 563 ± 15 K and to a damage level of 1.82 displacements per atom (dpa). Nominal neutron flux and dpa rate are 2.3 × 1014 n cm−2 s−1 and 3.4 × 10−7 dpa s−1, respectively. The microstructures of the Fe–Cr alloys were studied by atom probe tomography (APT) using a Cameca 4000X HR instrument. APT specimens were prepared by a standard lift-out process using a Quanta 3D 200i dual beam scanning electron microscope ensuring that the analyses were performed away from grain boundaries.

Bachhav, Mukesh↗

Atom probe datasets from neutron irradiated Fe-Cr alloys

A series of model Fe–Cr alloys containing 3–18 at.% Cr was neutron irradiated at a nominal temperature of 563 K to 1.82 dpa. Solute distributions were analyzed by atom probe tomography, which revealed α′ precipitation for alloys containing more than 9 at.% Cr. Both the Cr concentration dependence of α′ precipitation and the measured matrix compositions are in agreement with the recently published Fe–Cr phase diagrams. An irradiation-accelerated precipitation process is strongly suggested. Irradiation was carried out in the Advance Test Reactor (ATR) at Idaho National Laboratory. A series of six Fe–Cr alloys of nominal compositions 3, 6, 9, 12, 15 and 18 at.% Cr was irradiated at a neutron fluence (E > 1 MeV) of 1.1 × 1021 n cm−2 at 563 ± 15 K and to a damage level of 1.82 displacements per atom (dpa). Nominal neutron flux and dpa rate are 2.3 × 1014 n cm−2 s−1 and 3.4 × 10−7 dpa s−1, respectively. The microstructures of the Fe–Cr alloys were studied by atom probe tomography (APT) using a Cameca 4000X HR instrument. APT specimens were prepared by a standard lift-out process using a Quanta 3D 200i dual beam scanning electron microscope ensuring that the analyses were performed away from grain boundaries.

Bachhav, Mukesh↗

6cr

A series of model Fe–Cr alloys containing 3–18 at.% Cr was neutron irradiated at a nominal temperature of 563 K to 1.82 dpa. Solute distributions were analyzed by atom probe tomography, which revealed α′ precipitation for alloys containing more than 9 at.% Cr. Both the Cr concentration dependence of α′ precipitation and the measured matrix compositions are in agreement with the recently published Fe–Cr phase diagrams. An irradiation-accelerated precipitation process is strongly suggested. Irradiation was carried out in the Advance Test Reactor (ATR) at Idaho National Laboratory. A series of six Fe–Cr alloys of nominal compositions 3, 6, 9, 12, 15 and 18 at.% Cr was irradiated at a neutron fluence (E > 1 MeV) of 1.1 × 1021 n cm−2 at 563 ± 15 K and to a damage level of 1.82 displacements per atom (dpa). Nominal neutron flux and dpa rate are 2.3 × 1014 n cm−2 s−1 and 3.4 × 10−7 dpa s−1, respectively. The microstructures of the Fe–Cr alloys were studied by atom probe tomography (APT) using a Cameca 4000X HR instrument. APT specimens were prepared by a standard lift-out process using a Quanta 3D 200i dual beam scanning electron microscope ensuring that the analyses were performed away from grain boundaries.

Bachhav, Mukesh↗

A New Method of Absorption-Phase Nanotomography for 3D Observation of Mineral-Organic-Water Textiles and its Application to Pristine Carbonaceous Chondrites

Pristine carbonaceous chondrites contain fine-grained matrix, which is composed largely of amorphous silicates, sub-micron silicate and sulfide crystals, and organic materials. They are regarded as primitive dust in the early Solar System that have suffered minimal alteration in their parent bodies. The matrix generally has different lithologies; some of them are unaltered but some are more or less aqueously altered. Their textures have been examined in 2D usually by FE-SEM/EDS, TEM/EDS, nano-SIMS and micro-XRD. Observation of their complex fine textures, such as spatial relation between different lithologies in 3D, is important for understanding aggregation and alteration processes. Synchrotron radiation (SR)-based X-ray tomography reveals 3D structures nondestructively with high spatial resolution of approximately greater than 100 nm. We have developed a new technique using absorption contrasts called "dual-energy tomography" (DET) to obtain 3D distribution of minerals at SPring-8, SR facility in Japan, and applied successfully to Itokawa particles. Phase and absorption contrast images can be simultaneously obtained in 3D by using "scanning-imaging x-ray microscopy" (SIXM) at SPring-8, which can discriminate between void, water and organic materials. We applied this technique combined with FIB micro-sampling to carbonaceous chondrites to search for primitive liquid water. In this study, we combined the DET and SIXM to obtain three dimensional submicron-scale association between minerals, organic materials and water and applied this to pristine carbonaceous chondrites.

Tsuchiyama, A.↗

Development of Human-Spacesuit Interaction Models

Today’s astronaut corps represents a wide range of various anthropometric dimensions. Accommodating this wide range of anthropometry and protecting for size variations in future crews, makes spacesuit sizing and fit a challenging and necessary aspect of suit development. Spacesuit fit can play an important role in performance, but a suit fit assessment, especially in dynamic postures, is difficult without extensive human-in-the-loop testing. One approach to address this issue is to model and simulate the human-spacesuit interactions for a target population early in the design process. The Anthropometry and Biomechanics Facility (ABF) at the NASA Johnson Space Center has been working to incorporate parametric human models based on 3D full-body scan data with spacesuit CAD models that can be driven by the user or imported motion capture data. An articulated spacesuit model combined with a poseable high-fidelity human model allows comparisons to be made between spacesuit capabilities and normal human ranges of motion. Furthermore, predictions can be made as to how a specific individual or population may perform in the suit from the perspective of reach and mobility. In this paper, we will present case study examples of reach, mobility, and fit analyses that can be done with these models and the methodology developed thus far. These models have the potential to become powerful tools for evaluating future spacesuit design architectures from the perspective of optimizing fit and performance.

Jarvis, Sarah↗

Scan strategies in EBM-printed IN718 and the physics of bulk 3D microstructure development

Three-dimensional (3D) characterization provides opportunities for understanding processing-structure relationships in additively manufactured (AM) materials. Bulk samples of Inconel 718 were fabricated via electron beam melting (EBM) in order to study microstructural development as a function of energy input and beam scan strategy. TriBeam tomography of bulk Inconel 718 microstructures built under steady-state growth conditions reveals the sensitivity of microstructure formation and evolution to machine process parameters. Here, samples manufactured using a narrow range of energy input per unit build area result in varied grain morphologies and crystallographic textures. Using TRUCHAS, a thermal simulation software, the thermal history of bulk scan strategies was predicted, and combined with a calibrated microstructure-processing map to accurately predict bulk grain morphologies. The solidification parameters and the 3D measured nucleation density are used to predict the transition between columnar and equiaxed grain morphologies, providing a process map to guide AM parameter choices to locally control as-printed microstructure. A two-dimensional metric for characterizing bulk grain morphology was also found to agree well with predictions from the process map calibrated by 3D data. Combined with 3D tomography and thermal modelling, the physics of structure development were understood at a new level of detail with respect to the competing processes of grain nucleation and epitaxial growth.

36 MATERIALS SCIENCE↗

SU-F-T-555: Accurate Stereotactic Cone TMRs Converted from PDDs Scanned with Ray Trace

Purpose: To investigate whether the accuracy of TMRs for stereotactic cones converted from PDDs scanned with Ray Trace can be improved, when compared against the TMRs converted from the traditional PDDs. Methods: Ray Trace measurement in Sun Nuclear 3D Scanner is for accurate scan of small field PDDs. The system detects the center of field at two depths, for example, at 3 and 20 cm in our study, and then performs scan along the line passing the two centers. With both Ray Trace and the traditional method, PDDs for conical cones of 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter (jaws set to 5×5 cm) were obtained for 6X FFF and 10X FFF energies on a Varian Edge linac, using Edge detectors. The formalism of converting PDD to TMR given in Khan’s book (4th Edition, p.161) was applied. Sp values at dmax were obtained by measuring cone Scp and Sc. Continuous direct measurement of TMR by filling/draining water to/from the tank and spot measurement by moving the tank and detector were also performed with the same equipment, using 100 cm SDD. Results: For 6XFFF energy and all the cones, TMRs converted from Ray Trace were very close to the continuous and spot measurement, while TMRs converted from traditional PDDs had larger deviation. Along the central axis beyond dmax, 1.7% of TMR data points calculated from Ray Trace had more 3% deviation from measurement, with maximal deviation of 5.2%. Whereas, 34% of TMR points calculated from traditional PDDs had more than 3% deviation, with maximum of 5.7%. In this initial study, Ray Trace scans for 10XFFF beam were noisy, further measurement is warranted. Conclusion: The Ray Trace could improve the accuracy of PDDs measurement and the calculated TMRs for stereotactic cones, which was within 3% of the measured TMRs.

60 APPLIED LIFE SCIENCES↗

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens↗

SU-G-JeP2-12: Quantification of 3D Geometric Distortion for 1.5T and 3T MRI Scanners Used for Radiation Therapy

Purpose: To quantify the magnitude of geometric distortion for MRI scanners and provide recommendations for MRI imaging for radiation therapy Methods: A novel phantom, QUASAR MRID3D [Modus Medical Devices Inc.], was scanned to evaluate the level of 3D geometric distortion present in five MRI scanners used for radiation therapy in our department. The phantom was scanned using the body coil with 1mm image slice thickness to acquire 3D images of the phantom body. The phantom was aligned to its geometric center for each scan, and the field of view was set to visualize the entire phantom. The dependence of distortion magnitude with distance from imaging isocenter and with magnetic field strength (1.5T and 3T) was investigated. Additionally, the characteristics of distortion for Siemens and GE machines were compared. The image distortion for each scanner was quantified in terms of mean, standard deviation (STD), maximum distortion, and skewness. Results: The 3T and 1.5T scans show a similar absolute distortion with a mean of 1.38mm (0.33mm STD) for 3T and 1.39mm (0.34mm STD) for 1.5T for a 100mm radius distance from isocenter. Some machines can have a distortion larger than 10mm at a distance of 200mm from the isocenter. The distortions are presented with plots of the x, y, and z directional components. Conclusion: The results indicate that quantification of MRI image distortion is crucial in radiation oncology for target and organ delineation and treatment planning. The magnitude of geometric distortion determines the margin needed for target contouring which is usually neglected in treatment planning process, especially for SRS/SBRT treatments. Understanding the 3D distribution of the MRI image distortion will improve the accuracy of target delineation and, hence, treatment efficacy. MRI imaging with proper patient alignment to the isocenter is vital to reducing the effects of MRI distortion in treatment planning.

60 APPLIED LIFE SCIENCES↗

Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 Multiplication-Sign 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction ({approx}650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM Trade-Mark-Sign (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 {+-} 2.0 mm, 5.1 {+-} 3.1 mm, and 17.9 {+-} 5.1 mm in the planning 4DCT, and 2.8 {+-} 1.6 mm, 5.3 {+-} 3.1 mm, and 16.5 {+-} 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 {+-} 0.7 and 4.2 {+-} 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R{sup 2}= 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used.

60 APPLIED LIFE SCIENCES↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

Experimental tests of linear and nonlinear three-dimensional equilibrium models in DIII-D

DIII-D experiments using new detailed magnetic diagnostics show that linear, ideal magnetohydrodynamics (MHD) theory quantitatively describes the magnetic structure (as measured externally) of three-dimensional (3D) equilibria resulting from applied fields with toroidal mode number n = 1, while a nonlinear solution to ideal MHD force balance, using the VMEC code, requires the inclusion of n ≥ 1 to achieve similar agreement. These tests are carried out near ITER baseline parameters, providing a validated basis on which to exploit 3D fields for plasma control development. Scans of the applied poloidal spectrum and edge safety factor confirm that low-pressure, n = 1 non-axisymmetric tokamak equilibria are determined by a single, dominant, stable eigenmode. However, at higher beta, near the ideal kink mode stability limit in the absence of a conducting wall, the qualitative features of the 3D structure are observed to vary in a way that is not captured by ideal MHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-41: 3D MTP-TRUS for Prostate Implant

Purpose: Prostate brachytherapy is an effective treatment for early prostate cancer. The current prostate implant is limited to using 2D transrectal ultrassound (TRUS) or machenical motor driven 2D array either in the end or on the side. Real-time 3D images can improve the accuracy of the guidance of prostate implant. The concept of our system is to allow realtime full visualization of the entire prostate with the multiple transverse scan. Methods: The prototype of 3D Multiple-Transverse-Plane Transrectal Ultrasound probe (MTP-TRUS) has been designed by us and manufactured by Blatek inc. It has 7 convex linear arrays and each array has 96 elements. It is connected to cQuest Fire bird research system (Cephasonics inc.) which is a flexible and configurable ultrasound-development platform. The size of cQuest Firebird system is compact and supports the real-time wireless image transferring. A relay based mux board is designed for the cQuest Firebird system to be able to connect 672 elements. Results: The center frequency of probe is 6MHz±10%. The diameter of probe is 3cm and the length is 20cm. The element pitch is 0.205 mm. Array focus is 30mm and spacing 1.6cm. The beam data for each array was measured and met our expectation. The interface board of MTP-TURS is made and able to connect to cQuest Firebird system. The image display interface is still under the development. Our real-time needle tracking algorithm will be implemented too. Conclusion: Our MTP-TRUS system for prostate implant will be able to acquire real-time 3D images of prostate and do the real-time needle segmentation and tracking. The system is compact and have wireless function.

60 APPLIED LIFE SCIENCES↗

3D Volumetric Analysis of Wind Turbine Wake Properties in the Atmosphere Using High-Resolution Doppler Lidar

Wind turbine wakes in the atmosphere are three-dimensional (3D) and time dependent. An important question is how best to measure atmospheric wake properties, both for characterizing these properties observationally and for verification of numerical, conceptual, and physical (e.g., wind tunnel) models of wakes. Here a scanning, pulsed, coherent Doppler lidar is used to sample a turbine wake using 3D volume scan patterns that envelop the wake and simultaneously measure the inflow profile. The volume data are analyzed for quantities of interest, such as peak velocity deficit, downwind variability of the deficit, and downwind extent of the wake, in a manner that preserves the measured data. For the case study presented here, in which the wake was well defined in the lidar data, peak deficits of up to 80% were measured 0.6-2 rotor diameters (D) downwind of the turbine, and the wakes extended more than 11D downwind. Temporal wake variability over periods of minutes and the effects of atmospheric gusts and lulls in the inflow are demonstrated in the analysis. Lidar scanning trade-offs important to ensuring that the wake quantities of interest are adequately sampled by the scan pattern, including scan coverage, number of scans per volume, data resolution, and scan-cycle repeat interval, are discussed.

17 WIND ENERGY↗

R and DE Robotic Sensor Intern Team: Advanced Sensor Suite Prototype

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel is an example of such an environment where a biannual inspection is currently performed. Presently inspections are performed by teleoperated robotic crawlers which provide low-res video feedback to the structural engineers. Advanced sensors: including Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. Possible sensors were a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The Hokuyo UTM-30LX-EW shown below provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. Along with the Lidar, a camera sensor, IMU sensor, pan-tit unit, and on board computer needed to be identified. The two panospheric cameras allow for full 360 deg. FOV. The IMU will give data on the state of the robot inside the tunnel. The computer is used to gather and process data on board and to control the pan-tilt system. Mounts were designed and 3D printed to build the prototype of the sensor suite. It was designed to have the Lidar on top With its full FOV free while having the camera below and as close to together as possible while still leaving much of their FOV visible. The design also managed the cables such that they were unlikely to be damaged if in tension and so that they did not intrude much on the cameras vision. The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. a postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans With one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 2) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved. The sensor trees depth accuracy was evaluated in comparison to a high end commercial FARO Terrestrial Laser Scanner (TLS) with specifications for millimeter accuracy at distances above 10 m. For the purposes of these tests, the depth measurements produced by the TLS were taken as ground truth. Example test wall panels were scanned with the TLS and postprocessed with its proprietary software, and subsequently scanned with the sensor tree system. The two scans were manually aligned and for each point in the output cloud from the sensor tree, the distance to the nearest ground truth point in the FARO cloud was determined. 98.7% of all produced points were within the specified target range of 6 mm, with an average deviation of 1.75 mm. The test walls used have an overall in-wall depth variation of around 40 mm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D Histopathology—a Lung Tissue Segmentation Workflow for Microfocus X-ray-Computed Tomography Scans

Lung histopathology is currently based on the analysis of 2D sections of tissue samples. The use of microfocus X-ray-computed tomography imaging of unstained soft tissue can provide high-resolution 3D image datasets in the range of 2–10 μm without affecting the current diagnostic workflow. Important details of structural features such as the tubular networks of airways and blood vessels are contained in these datasets but are difficult and time-consuming to identify by manual image segmentation. Providing 3D structures permits a better understanding of tissue functions and structural interrelationships. It also provides a more complete picture of heterogeneous samples. In addition, 3D analysis of tissue structure provides the potential for an entirely new level of quantitative measurements of this structure that have previously been based only on extrapolation from 2D sections. In this paper, a workflow for segmenting such 3D images semi-automatically has been created using and extending the ImageJ open-source software and key steps of the workflow have been integrated into a new ImageJ plug-in called LungJ. Results indicate an improved workflow with a modular organization of steps facilitating the optimization for different sample and scan properties with expert input as required. This allows for incremental and independent optimization of algorithms leading to faster segmentation. Representation of the tubular networks in samples of human lung, building on those segmentations, has been demonstrated using this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗