Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multiscale porosity characterization in additively manufactured polymer nanocomposites using micro-computed tomography

Extrusion-based additive manufacturing (AM) of polymer composites exhibits complex thermally driven phenomena that introduce severe discontinuities in the internal structure across length scales, especially voids or porosity. This study utilizes a high-throughput porosity characterization technique to analyze large datasets from numerous micro-computed tomography (mu CT) scans to capture the influence of AM print parameters on the size, shape, and location of porosity across multiple print layers (up to a few cm) on fused granular fabrication (FGF) printers. The materials investigated include nanocomposite formulations based on commercially relevant nylon-12 and polyether ketone ketone (PEKK) materials comprising nano- or micro- sized fillers. The estimated global porosity follows an inverse linear correlation against the bulk density of the printed samples. Increasing the extrusion multiplier (EM) and the nozzle temperature while decreasing the print speeds reduces the global porosity. Outlier analyses (local porosity morphology) show that faster print speeds and higher extrusion rates result in long, slender inter-layer voids, while lower nozzle temperatures lead to large, symmetrical, inter-bead voids (at the bead junction). Lack of active chamber temperature increases inter-layer and intra-bead voids with a two-fold increase in global porosity. Overall, the micro filler-reinforced composites exhibit higher global porosity than nanofiller-reinforced composites, which is attributed to the increased mismatch in the thermal expansion coefficient between the filler and the polymers used in the study.

36 MATERIALS SCIENCE↗

Deep learning for Alzheimer's disease: Mapping large-scale histological tau protein for neuroimaging biomarker validation

Abnormal tau inclusions are hallmarks of Alzheimer's disease and predictors of clinical decline. Several tau PET tracers are available for neurodegenerative disease research, opening avenues for molecular diagnosis in vivo. However, few have been approved for clinical use. Understanding the neurobiological basis of PET signal validation remains problematic because it requires a large-scale, voxel-to-voxel correlation between PET and (immuno) histological signals. Large dimensionality of whole human brains, tissue deformation impacting co-registration, and computing requirements to process terabytes of information preclude proper validation. We developed a computational pipeline to identify and segment particles of interest in billion-pixel digital pathology images to generate quantitative, 3D density maps. The proposed convolutional neural network for immunohistochemistry samples, IHCNet, is at the pipeline's core. We have successfully processed and immunostained over 500 slides from two whole human brains with three phospho-tau antibodies (AT100, AT8, and MC1), spanning several terabytes of images. Our artificial neural network estimated tau inclusion from brain images, which performs with ROC AUC of 0.87, 0.85, and 0.91 for AT100, AT8, and MC1, respectively. Introspection studies further assessed the ability of our trained model to learn tau-related features. We present an end-to-end pipeline to create terabytes-large 3D tau inclusion density maps co-registered to MRI as a means to facilitate validation of PET tracers.

60 APPLIED LIFE SCIENCES↗

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

Material Science Image Analysis using Quant-CT in ImageJ

We introduce a computational analysis workflow to access properties of solid objects using nondestructive imaging techniques that rely on X-ray imaging. The goal is to process and quantify structures from material science sample cross sections. The algorithms can differentiate the porous media (high density material) from the void (background, low density media) using a Boolean classifier, so that we can extract features, such as volume, surface area, granularity spectrum, porosity, among others. Our workflow, Quant-CT, leverages several algorithms from ImageJ, such as statistical region merging and 3D object counter. It also includes schemes for bilateral filtering that use a 3D kernel, for parallel processing of sub-stacks, and for handling over-segmentation using histogram similarities. The Quant-CT supports fast user interaction, providing the ability for the user to train the algorithm via subsamples to feed its core algorithms with automated parameterization. Quant-CT plugin is currently available for testing by personnel at the Advanced Light Source and Earth Sciences Divisions and Energy Frontier Research Center (EFRC), LBNL, as part of their research on porous materials. The goal is to understand the processes in fluid-rock systems for the geologic sequestration of CO2, and to develop technology for the safe storage of CO2 in deep subsurface rock formations. We describe our implementation, and demonstrate our plugin on porous material images. This paper targets end-users, with relevant information for developers to extend its current capabilities.

97 MATHEMATICS AND COMPUTING↗

A New Look at Aubrites: Investigating 3D Modal Mineralogy with X-Ray Computed Tomography

The aubrites (approximately 30 known meteorites) are a unique group of differentiated meteorites that formed on asteroids with oxygen fugacities (ƒO2) from approximately 2 to approximately 6 log units below the iron-wustite buffer. At these highly reduced conditions, elements deviate from the geochemical behavior exhibited at terrestrial ƒO2, forming FeO-poor silicates and exotic sulfides. While previous studies have described the petrology and 2D modal abundances of aubrites, this work investigates the 3D modal mineralogies of silicate, metal, and sulfide phases in aubrite samples, which are then compared to the available 2D data. In addition to 3D modal mineralogies, we have examined the geochemistry of fourteen aubrites, including mineral major-element compositions, bulk-rock compositions, and oxygen isotopic compositions to understand their formation and evolution at extreme ƒO2 conditions. We utilize X-ray computed tomography (XCT) to non-destructively analyze the distribution and abundances of mineral phases in aubrites and locate composite clasts of sulfide grains for future analytical study. In order to better constrain elemental behavior under reduced conditions, we specifically target minerals phases that comprise moderately volatile elements (i.e. oldhamite [CaS], caswellsilverite [NaCrS2] and djerfisherite [K6Na(Fe,Cu,Ni)25S26Cl]) as it has been shown that their geochemical behavior changes as a function of ƒO2. Currently, we have produced 3D scans of the Norton County aubrite. The results of the XCT data have allowed for the determination of the abundances of silicate groundmass (i.e., enstatite, forsterite, albite, and diopside), light (based on electron density) sulfides (i.e. alabandite [MnS] and daubréelite [FeCr2S4]), heavy (based on electron density) sulfides (i.e., troilite [FeS]), and Fe,Ni metal by segmenting a density histogram in Volume Graphics Studio software. XCT scans of additional aubrites are underway. By combining the 3D representation of the exotic phases found in aubrites with existing 2D characterizations, we are able to better determine modal abundances. By integrating 3D and 2D modal abundances and geochemistry, we can ultimately better constrain aubrite petrogenesis and elemental partitioning under reduced conditions. Furthermore, application of this new 3D approach offers the opportunity to identify and select clasts for future study prior to cutting the sample, which will minimize sample loss of this precious material.

Wilbur, Zoe↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

PyCMG-based Simulation of Volumetric Concrete Microstructure

Concrete is a complex, heterogeneous material with a microstructure composed of aggregates, cement paste, and pores spanning multiple length scales. Understanding this microstructure is critical for advancing the performance, durability, and modeling of concrete-based systems. While experimental imaging such as X-ray computed tomography (XCT) provides valuable insights, generating large datasets with detailed ground truth annotations is both costly and labor-intensive due to challenges in segmenting similar phases, such as aggregates and cement paste, that often share similar attenuation properties. To address this, we developed a pipeline to simulate realistic 3D concrete microstructures using the open-source Python package PyCMG. This simulation effort focuses on generating high-fidelity, annotated microstructures that can serve as training or benchmarking datasets for image analysis, segmentation algorithms, and machine learning models, particularly in scenarios where experimental data is scarce.

Ziabari, Amir [Oak Ridge National Laboratory; ORNL↗

Three-dimensional reconstruction and morphologic characteristics of porous metal fiber sintered sheet

This paper presents an approach to achieve morphological characterizing for complex porous materials based on micro X-ray tomography images, with an example of a novel porous metal fiber sheet produced through solid-state sintering method. The geometrical reconstruction was performed after selection of volume of interest and image processing of anisotropic diffusion smooth. The reconstructed gray level images were then transferred into binary images by adjusting binarization threshold according to the actual porosity. Taking into account the tubular structural feature of the fibers, skeleton extraction algorithm based on the distance transform function was applied and further improved by the scale axis transform method. The skeleton was later pruned and segmented according to the contact points to perform morphological characterizing. Compared with actual manufacturing parameters, the style, length, radius, orientation and tortuosity of fiber segments were discussed. The results show that our proposed method can well describe the actual geometrical and morphological characteristics, which will provide a promising method for the structural description of fibrous networks. - Highlights: • Micro-CT technology was used to achieve the 3D geometrical reconstruction. • Skeleton extraction algorithm was modified to get the medial skeleton. • Skeleton filter operation was adopted to deal with the segmented skeleton. • Useful morphological statistics was obtained through skeleton segments. • Relationship between structure and manufacturing processes was discussed.

36 MATERIALS SCIENCE↗

TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

SU-C-213-01: 3D Printed Patient Specific Phantom Composed of Bone and Soft Tissue Substitute Plastics for Radiation Therapy

Purpose: 3D printed phantoms constructed of multiple tissue approximating materials could be useful in both clinical and research aspects of radiotherapy. This work describes a 3D printed phantom constructed with tissue substitute plastics for both bone and soft tissue; air cavities were included as well. Methods: 3D models of an anonymized nasopharynx patient were generated for air cavities, soft tissues, and bone, which were segmented by Hounsfield Unit (HU) thresholds. HU thresholds were chosen to define air-to-soft tissue boundaries of 0.65 g/cc and soft tissue-to-bone boundaries of 1.18 g/cc based on clinical HU to density tables. After evaluation of several composite plastics, a bone tissue substitute was identified as an acceptable material for typical radiotherapy x-ray energies, composed of iron and PLA plastic. PET plastic was determined to be an acceptable soft tissue substitute. 3D printing was performed on a consumer grade dual extrusion fused deposition model 3D printer. Results: MVCT scans of the 3D printed heterogeneous phantom were acquired. Rigid image registration of the patient and the 3D printed phantom scans was performed. The average physical density of the soft tissue and bone regions was 1.02 ± 0.08 g/cc and 1.39 ± 0.14 g/cc, respectively, for the patient kVCT scan. In the 3D printed phantom MVCT scan, the average density of the soft tissue and bone was 1.01 ± 0.09 g/cc and 1.44 ± 0.12 g/cc, respectively. Conclusion: A patient specific phantom, constructed of heterogeneous tissue substitute materials was constructed by 3D printing. MVCT of the 3D printed phantom showed realistic tissue densities were recreated by the 3D printing materials. Funding provided by intra-department grant by University of Minnesota Department of Radiation Oncology.

60 APPLIED LIFE SCIENCES↗

Evaluating Quantity of Decommissioning Waste by Cutting Virtual 3D Objects in Large Equipment - 19111

Equipment and piping components contaminated by radioactive materials and/or including irradiated materials as low-level wastes must be cut, segmented, and packed in waste containers. There is a trade-off between cost and exposure dose when packing waste fragments into containers, if the fragments are cut into small sizes, although the number of containers becomes less than the number of larger fragments, the cutting work hours and exposure dose would increase. To avoid excess exposure dose and minimize number of waste containers for many pieces of equipment and piping components, an automatic planning method for virtual cutting of 3D equipment objects under the constraints of container sizes, maximum radioactivity, maximum weight, and maximum dose rate was developed. It was confirmed that the developed method effectively evaluates size, weight, and amount of radioactivity in each container automatically. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular Predictors of 3D Morphogenesis by Breast Cancer Cell Lines in 3D Culture

Correlative analysis of molecular markers with phenotypic signatures is the simplest model for hypothesis generation. In this paper, a panel of 24 breast cell lines was grown in 3D culture, their morphology was imaged through phase contrast microscopy, and computational methods were developed to segment and represent each colony at multiple dimensions. Subsequently, subpopulations from these morphological responses were identified through consensus clustering to reveal three clusters of round, grape-like, and stellate phenotypes. In some cases, cell lines with particular pathobiological phenotypes clustered together (e.g., ERBB2 amplified cell lines sharing the same morphometric properties as the grape-like phenotype). Next, associations with molecular features were realized through (i) differential analysis within each morphological cluster, and (ii) regression analysis across the entire panel of cell lines. In both cases, the dominant genes that are predictive of the morphological signatures were identified. Specifically, PPAR? has been associated with the invasive stellate morphological phenotype, which corresponds to triple-negative pathobiology. PPAR? has been validated through two supporting biological assays.

3D cell culture models, breast cancer cell lines, ↗

Impact of Endografting on the Thoracic Aortic Anatomy: Comparative Analysis of the Aortic Geometry before and after the Endograft Implantation

Purpose: Although the widespread acceptance of thoracic endovascular aortic repair (TEVAR) as a first-line treatment option for a multitude of thoracic aortic diseases, little is known about the consequences of the device implantation on the native aortic anatomy. We propose a comparative analysis of the pre- and postoperative geometry on a clinical series of patients and discuss the potential clinical implications Methods: CT pre- and postoperative acquisitions of 30 consecutive patients treated by TEVAR for different pathologies (20 thoracic aortic aneurysms, 6 false aneurysms, 3 penetrating ulcers, 1 traumatic rupture) were used to model the vascular geometry. Pre- and postoperative geometries were compared for each patient by pairing and matching the 3D models. An implantation site was identified, and focal differences were detected and described. Results: Segmentation of the data sets was successfully performed for all 30 subjects. Geometry differences between the pre- and postoperative meshes were depicted in 23 patients (76 %). Modifications at the upper implantation site were detected in 14 patients (47 %), and among them, the implantation site involved the arch (Z0–3) in 11 (78 %). Conclusion: Modeling the vascular geometry on the basis of imaging data offers an effective tool to perform patient-specific analysis of the vascular geometry before and after the treatment. Future studies will evaluate the consequences of these changes on the aortic function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic analysis of magnetic equilibrium reconstruction with eddy currents on LTX- β

Magnetic equilibrium reconstruction in the Lithium Tokamak Experiment-Beta (LTX-β) is complicated by strong eddy currents and toroidal asymmetries arising from its segmented, close-fitting conducting shell. In the earlier experiment LTX, these three-dimensional (3D) conductor effects significantly distorted diagnostic signals and challenged conventional axisymmetric reconstruction methods. In this work, we demonstrate that accurate plasma equilibria can be recovered on LTX-β by incorporating a small number of dominant eddy current modes derived from realistic conductor models. Using the open-source $\tt{TokaMaker}$ Grad–Shafranov solver, we reconstruct equilibria across a systematically selected set of LTX-β discharges and validate them against the legacy $\tt{PSI-Tri}$ hybrid 2D-3D code. Our results show that fully 2D $\tt{TokaMaker}$ reconstructions achieve significantly improved agreement with flux loop and Mirnov probe measurements, reducing total chi-squared fitting errors, especially during startup. Finally, we develop new hybrid 2D-3D $\tt{TokaMaker}$ reconstructions by integrating the $\tt{ThinCurr}$ 3D eddy current model, which we optimize for significant further reduction of chi-squared in most scenarios. These findings underscore the importance of realistic wall-current modeling in short-pulse tokamaks, and establish a physics-based reconstruction framework that is extensible to devices with complex passive structures and 3D wall interactions.

Grad–Shafranov solver↗

Three-Dimensional Ultrastructure of Arabidopsis Cotyledons Infected with Colletotrichum higginsianum

We used serial block-face scanning electron microscopy (SBF-SEM) to study the host–pathogen interface between Arabidopsis cotyledons and the hemibiotrophic fungus Colletotrichum higginsianum. By combining high-pressure freezing and freeze-substitution with SBF-SEM, followed by segmentation and reconstruction of the imaging volume using the freely accessible software IMOD, we created 3D models of the series of cytological events that occur during the Colletotrichum–Arabidopsis susceptible interaction. We found that the host cell membranes underwent massive expansion to accommodate the rapidly growing intracellular hypha. As the fungal infection proceeded from the biotrophic to the necrotrophic stage, the host cell membranes went through increasing levels of disintegration culminating in host cell death. Intriguingly, we documented autophagosomes in proximity to biotrophic hyphae using transmission electron microscopy (TEM) and a concurrent increase in autophagic flux between early to mid/late biotrophic phase of the infection process. Occasionally, we observed osmiophilic bodies in the vicinity of biotrophic hyphae using TEM only and near necrotrophic hyphae under both TEM and SBF-SEM. Overall, we established a method for obtaining serial SBF-SEM images, each with a lateral ( x-y) pixel resolution of 10 nm and an axial ( z) resolution of 40 nm, that can be reconstructed into interactive 3D models using the IMOD. Application of this method to the Colletotrichum–Arabidopsis pathosystem allowed us to more fully understand the spatial arrangement and morphological architecture of the fungal hyphae after they penetrate epidermal cells of Arabidopsis cotyledons and the cytological changes the host cell undergoes as the infection progresses toward necrotrophy. [Formula: see text] Copyright © 2024 The Author(s). This is an open access article distributed under the CC BY 4.0 International license .

Biochemistry & Molecular Biology↗

Evaluation of a multi-atlas based method for segmentation of cardiac CTA data: a large-scale, multicenter, and multivendor study

Purpose: Computed tomography angiography (CTA) is increasingly used for the diagnosis of coronary artery disease (CAD). However, CTA is not commonly used for the assessment of ventricular and atrial function, although functional information extracted from CTA data is expected to improve the diagnostic value of the examination. In clinical practice, the extraction of ventricular and atrial functional information, such as stroke volume and ejection fraction, requires accurate delineation of cardiac chambers. In this paper, we investigated the accuracy and robustness of cardiac chamber delineation using a multiatlas based segmentation method on multicenter and multivendor CTA data. Methods: A fully automatic multiatlas based method for segmenting the whole heart (i.e., the outer surface of the pericardium) and cardiac chambers from CTA data is presented and evaluated. In the segmentation approach, eight atlas images are registered to a new patient's CTA scan. The eight corresponding manually labeled images are then propagated and combined using a per voxel majority voting procedure, to obtain a cardiac segmentation. Results: The method was evaluated on a multicenter/multivendor database, consisting of (1) a set of 1380 Siemens scans from 795 patients and (2) a set of 60 multivendor scans (Siemens, Philips, and GE) from different patients, acquired in six different institutions worldwide. A leave-one-out 3D quantitative validation was carried out on the eight atlas images; we obtained a mean surface-to-surface error of 0.94{+-}1.12 mm and an average Dice coefficient of 0.93 was achieved. A 2D quantitative evaluation was performed on the 60 multivendor data sets. Here, we observed a mean surface-to-surface error of 1.26{+-}1.25 mm and an average Dice coefficient of 0.91 was achieved. In addition to this quantitative evaluation, a large-scale 2D and 3D qualitative evaluation was performed on 1380 and 140 images, respectively. Experts evaluated that 49% of the 1380 images were very accurately segmented (below 1 mm error) and that 29% were accurately segmented (error between 1 and 3 mm), which demonstrates the robustness of the presented method. Conclusions: A fully automatic method for whole heart and cardiac chamber segmentation was presented and evaluated using multicenter/multivendor CTA data. The accuracy and robustness of the method were demonstrated by successfully applying the method to 1420 multicenter/multivendor data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining registration and active shape models for the automatic segmentation of the lymph node regions in head and neck CT images

Purpose: Intensity-modulated radiation therapy (IMRT) is the state of the art technique for head and neck cancer treatment. It requires precise delineation of the target to be treated and structures to be spared, which is currently done manually. The process is a time-consuming task of which the delineation of lymph node regions is often the longest step. Atlas-based delineation has been proposed as an alternative, but, in the authors' experience, this approach is not accurate enough for routine clinical use. Here, the authors improve atlas-based segmentation results obtained for level II-IV lymph node regions using an active shape model (ASM) approach. Methods: An average image volume was first created from a set of head and neck patient images with minimally enlarged nodes. The average image volume was then registered using affine, global, and local nonrigid transformations to the other volumes to establish a correspondence between surface points in the atlas and surface points in each of the other volumes. Once the correspondence was established, the ASMs were created for each node level. The models were then used to first constrain the results obtained with an atlas-based approach and then to iteratively refine the solution. Results: The method was evaluated through a leave-one-out experiment. The ASM- and atlas-based segmentations were compared to manual delineations via the Dice similarity coefficient (DSC) for volume overlap and the Euclidean distance between manual and automatic 3D surfaces. The mean DSC value obtained with the ASM-based approach is 10.7% higher than with the atlas-based approach; the mean and median surface errors were decreased by 13.6% and 12.0%, respectively. Conclusions: The ASM approach is effective in reducing segmentation errors in areas of low CT contrast where purely atlas-based methods are challenged. Statistical analysis shows that the improvements brought by this approach are significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗