Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - AIRFOILS - OSCILLATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Classroom aerosol dispersion modeling: experimental assessment of a low-cost flow simulation tool

The purpose of this study was to assess the utility of a low-cost flow simulation tool for an indoor air modeling application by comparing its outputs with the results of a physical experiment, as well as those from a more advanced computational fluid dynamics (CFD) software package. In this study, five aerosol dispersion tests were performed in two different classrooms by releasing a CO 2 tracer gas from six student locations. Resultant steady-state concentrations were monitored at 13 locations around the periphery of the room. Subsequently, the experiments were modeled using both a low-cost tool (SolidWorks Flow Simulation) and a more sophisticated tool (STAR-CCM+). Models were evaluated based on their ability to predict the experimentally measured concentrations at the 13 monitoring locations by calculating four performance parameters commonly used in the evaluation of dispersion models: fractional mean bias (FB), normalized mean-square error (NMSE), fraction of predicted value within a factor of two (FAC2), and normalized absolute difference (NAD). The more sophisticated model performed better in 15 of the 20 possible cases (five tests at four parameters each), with parameters meeting acceptance criteria in 19 of 20 cases. However, the lower-cost tool was only slightly worse, with parameters meeting acceptance criteria in 18 of 20 cases, and it performed better than the other tool in 3 of 20 cases. Because it provides useful results at a fraction of the monetary and training cost and is already widely accessible to many institutions, such a tool may be worthwhile for many indoor aerosol dispersion applications, especially for students or researchers just beginning CFD modeling.

54 ENVIRONMENTAL SCIENCES↗

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Energy Storage Analysis

This study presents a comprehensive techno-economic characterization of energy storage and exible low carbon power generation technologies that can shift energy across days, weeks, or months to balance daily, weekly, and seasonal disparities in supply and demand. Energy storage technologies evaluated here include pumped hydropower storage (PHS), adiabatic and diabatic compressed air energy storage (CAES), vanadium redox flow batteries (VRBs), pumped thermal energy storage (P-TES), and renewably produced hydrogen stored in either geologic formations or underground pipes with re-electrification via combustion turbines in combined cycles, stationary proton exchange membrane (PEM) fuel cells, or the novel use of PEM fuel cells designed for heavy-duty vehicles (HDVs) which are expected to have shorter lives but also lower capital costs. We also evaluate flexible low-carbon power generation systems, including ethanol combustion in gas turbines and natural gas combustion with carbon capture and sequestration (CCS). We estimate current costs with literature data, use learning rates to characterize future costs, and develop capacity factors calibrated to an 85% renewables grid to calculate the levelized cost of energy (LCOE) of each technology. Results illustrate that at the 12-hour storage duration, PHS and CAES have the lowest LCOE with current costs, and VRBs become competitive if future costs are achieved. At the 120-hour storage duration, hydrogen systems with geologic storage and natural gas with CCS achieve the lowest LCOE in both current and future capital cost scenarios. In particular, the new configuration of HDV-PEM fuel cells with hydrogen storage in geologic formations evaluated here could lower the LCOE by 22-27% compared to stationary fuel cell systems typically evaluated and might help enable very high (>80%) renewable energy electric power systems. P-TES and hydrogen stored in underground pipes are the least-cost options at the 120-hour storage duration rating that do not require some form of geologic storage. Sensitivity analysis and Monte Carlo analysis illustrate that the general trends seen in this study are valid for a wide range of capacity factors and future cost scenarios. The study also illustrates that coproducing and selling hydrogen to other markets could reduce the LCOE of hydrogen systems by up to 39%.

carbon capture and sequestration↗

Adsorption of Iodine on Metal Coupons in Humid and Dry Environments

In this study, five different metal coupons were evaluated for gaseous iodine [I2(g)] adsorption including two stainless steels (i.e., SS304 and SS316), two Inconel® alloys (i.e., 625 and 718) and pure Ni (i.e., Ni-200) within a dynamic flow-through system where temperature, iodine concentration, flow rate, atmosphere, and relative humidity were controlled. Humidity was shown to be critical to iodine adsorption on SS304 and SS316 and Ni-200 at ambient temperatures. The results presented herein suggest that a moisture mediated reaction is occurring. However, higher humidity levels decrease the adsorption, suggesting an ideal range of humidity for highest corrosion. A comparison of the five metal substrates showed the highest I2(g) adsorption in the following descending order Ni-200 > SS304 > SS316 >718>625.The 625 and 718 Inconel alloys were fairly inert to iodine adsorption under the conditions tested. Characterization by scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction of the Ni-200 coupon indicates that NiI2 is formed and flakes off the surface as a black powder. The SS304 and SS316 coupons showed evidence of extensive reactions with I2(g) and formed a much more deliquescent corrosion product, which reacted with air when removed from the flow-through system for weighing on the analytical balance. These findings assist in predicting iodine adsorption behavior on a variety of metal surfaces under various conditions.

Beck, Chelsie L.↗

Heat transfer coefficients of moving particle beds from flow-dependent thermal conductivity and near-wall resistance

Accurate determination of heat transfer coefficients for flowing packed particle beds is essential to the design of particle heat exchangers and other thermal and thermochemical equipment. While such dense granular flows mostly fall into the well-known plug-flow regime, the discrete nature of granular materials alters the thermal transport processes in both the near-wall and bulk regions of flowing particle beds from their stationary counterparts. As a result, heat transfer correlations based on the stationary particle bed thermal conductivity could be inadequate for flowing particles in a heat exchanger. Most earlier works have achieved a reasonable agreement with experiments by treating granular heat transfer media as a plug-flow continuum with a near-wall thermal resistance in series. However, the thermal conductivity values of the continuum were often obtained from measurements on stationary beds owing to the difficulty of flowing bed measurements. In this work, it was found that the properties of a stationary bed are highly sensitive to the method of particle packing and there is a decrease in the particle bed thermal conductivity and increase in the near-wall thermal resistance, measured as an effective air gap thickness, on the onset of particle flow. These variations in thermal conductivity of stationary and flowing particle beds can lead to errors in heat transfer coefficient calculations. Therefore, the heat transfer coefficients for granular flows were calculated using experimentally determined flowing particle bed thermal conductivity and near-wall air gap for ceramic particles – CARBO CP 40/100 (mean diameter = 275 µm), HSP 40/70 (404 µm) and HSP 16/30 (956 µm); at velocities of 5–15 mm·s –1 ; and temperatures of 300–650 °C. The thermal conductivity and air gap values for CP 40/100 and HSP 40/70 were further used to calculate heat transfer coefficients across different particle bed temperatures and velocities for different parallel-plate heat exchanger dimensions. Furthermore, these calculations, which show good agreement with measured HTC values reported in literature, can be used as a guide for heat exchanger designs. Graphical abstract

14 SOLAR ENERGY↗

Digital Twin Model for Advanced Manufacture of a Rotating Detonation Engine Injector

A digital twin material model (DTMM) of an additive manufacturing (AM) process was created to advance the state of the art in rotating detonation engine (RDE) injector design. Current RDE injectors are designed with large pressure drops, enabling a stable and repeatable combustion process. However, this comes at the cost of system efficiency. For the technology to transition to commercial fossil-based power generation, it is important to develop injectors with reduced flow losses. Low-loss injectors are difficult to design and manufacture with conventional manufacturing techniques. AM enables new design options, but the AM manufacturing process must be thoroughly understood to result in a robust design. A DTMM provides the necessary insight by defining the cause-effect relationships between process parameters, microstructure features, and properties. Therefore, a DTMM to support the design and manufacturing process was developed and applied to the design of a new additively manufactured low-loss injector. The injector combustion behavior was characterized through hot-fire tests, and mechanical performance was compared to the DTMM predictions. The two project goals were the successful development of the DTMM and the demonstration of an improved RDE injector design. The RDE injector design and DTMM developments occurred on parallel but dependent paths. The injector was designed to reduce pressure drop by increasing the cross-sectional flow area ratio between the injector air passages and the combustor annulus. This resulted in less structural material, raising the concern that thin members would be susceptible to high-cycle fatigue (HCF) under the periodic loading inherent to an RDE. It was most important for the DTMM to predict behavior in these features; therefore, the injector design concept guided the material thicknesses used in fatigue tests. The DTMM development started by manufacturing a series of coupons over the range of possible AM process variations. A design-of-experiment approach was used to select which process variable combinations gave the most efficient coverage relevant to the injector design space. The microstructure in each of these coupons was characterized, and then computational methods were used to create a numerical model of the correlation between process variables and microstructure. Next, a set of HCF samples were tested to calibrate existing models that map microstructure to HCF performance. Together, these two links formed the DTMM that calculates HCF behavior from AM process variables. Two injector prototypes were additively manufactured. The first injector design strategy aggressively pursued low-loss performance by substantially increasing the oxidizer flow area. The combination of manufacturing lead times and the fatigue testing schedule meant that the DTMM was not available when building this first prototype. Therefore, its process parameters were chosen based on a manual review of the available coupon data. This prototype was built successfully and evaluated in 58 combustion tests. Sustained detonation was achieved with remarkably reduced pressure loss, and some tests even displayed pressure loss characteristics similar to conventional gas turbine combustors. This achieved the project goal of improving RDE injector design. The second injector was manufactured according to the optimized parameters predicted by the DTMM. The flow area modifications of this injector were less aggressive than the first injector since demonstrating low pressure loss was not an objective of the second hot-fire test series. Rather, the test objective was to cause high cycle fatigue failure in the part due to periodic loading from the rotating detonation wave. The observed number of cycles to failure was to be compared to the number predicted by the DTMM and thereby assess the utility of the DTMM in component design. However, the required level of vibration was not obtained during combustion. Therefore, high cycle fatigue was not experienced in the hot-fire tests of the second injector. Fatigue data was obtained by further testing the second injector in a conventional HCF test apparatus. The injector demonstrated HCF strength above the DTMM prediction. In fact, it did not fail and testing was only discontinued due to reaching the end of the period of performance. This points to some success in the project’s primary goal of successfully developing and applying the DTMM to a component design. Implementing the DTMM recommendations for optimal processing parameters led to a part with acceptable properties. The DTMM was also shown to be an efficient correlator of data and to provide insight into the relationship between process settings, microstructure, and property performance. However, the failure of the DTMM prediction to match the experimental result of the injector fatigue test also points to the need to include significantly more data in the model development. In this project, coupons made with identical processing parameters exhibited drastically different properties from each other and from the injector part, which clearly influences the accuracy of a model that predicts performance based on parameters. Uncertainties in the build process must be quantified to develop more robust models. A denser and broader matrix of coupon process and geometry variations, several repeated builds of every point, more in-situ build process measurements, and direct observation of tensile and HCF sample microstructure (as opposed to separate microstructure specimens) are recommendations to improve future AM modeling efforts.

20 FOSSIL-FUELED POWER PLANTS↗

The Pacific Northwest Heat Wave of 25–30 June 2021: Synoptic/Mesoscale Conditions and Climate Perspective

Abstract An unprecedented heat wave occurred over the Pacific Northwest and southwest Canada on 25–30 June 2021, resulting in all-time temperature records that greatly exceeded previous record maximum temperatures. The impacts were substantial, including several hundred deaths, thousands of hospitalizations, a major wildfire in Lytton, British Columbia, Canada, and severe damage to regional vegetation. Several factors came together to produce this extreme event: a record-breaking midtropospheric ridge over British Columbia in the optimal location, record-breaking midtropospheric temperatures, strong subsidence in the lower atmosphere, low-level easterly flow that produced downslope warming on regional terrain and the removal of cooler marine air, an approaching low-level trough that enhanced downslope flow, the occurrence at a time of maximum insolation, and drier-than-normal soil moisture. It is shown that all-time-record temperatures have not become more frequent and that annual high temperatures only increased at the rate of baseline global warming. Although anthropogenic warming may have contributed as much as 1°C to the event, there is little evidence of further amplification from increasing greenhouse gases. Weather forecasts were excellent for this event, with highly accurate predictions of the extreme temperatures. Significance Statement This paper describes the atmospheric evolution that produced an extreme heat wave over the Pacific Northwest during June 2021 and puts this event into historical perspective.

Meteorology & Atmospheric Sciences↗

Ductility evaluation of nitrided Zircaloy-4 cladding by ring compression testing

Here, this study evaluated the embrittlement of Zircaloy-4 cladding by dry air and dry nitrogen environments as a function of process temperature and duration of exposure. A Netzsch thermogravimetric analyzer was used to measure the mass gain of cladding sections over time with specified temperature and gas flow programs. Oxidation of Zircaloy in dry air produced a brittle ZrO 2 layer with ductile unreacted metal. In contrast, nitridation of Zircaloy had a slower reaction rate but produced a brittle cladding that was more easily breached during ring compression tests. The ring compression tests demonstrated that ductility of Zircaloy cladding decreases as nitrogen pickup increases; a ductile-to-brittle transition occurs near a mass gain of 2.1 wt %. Nitridation showed minimal temperature dependency in ductility degradation, whereas oxidation showed significant temperature dependency in ductility degradation, with severe embrittlement occurring at 1200 °C. Optical micrographs confirmed the formation of uniform ZrN layers (approximately 12 µm thick) on the cladding surface, indicating that cladding embrittlement is primarily the result of nitrogen diffusion rather than metal layer thinning.

36 MATERIALS SCIENCE↗

Air resonance enhanced multiphoton ionization tagging velocimetry

Air resonance enhanced multiphoton ionization (REMPI) tagging velocimetry (ART) was demonstrated in quiescent and supersonic flows. The ART velocimetry method utilizes a wavelength tunable laser beam to resonantly ionize molecular oxygen in air and generate additional avalanche-type ionization of molecular nitrogen. The fluorescence emissions from the first negative and first positive bands of molecular nitrogen are, thus, produced and used for flow tagging. Detailed characterization of ART was conducted, including the effects of oxygen resonance to fluoresce nitrogen, nitrogen fluorescence spectrum, laser energy deposition into quiescent flow showing minimal perturbations in flow, fluorescence lifetime study at various pressures, and line tagging without breakdown. Pointwise velocity measurements within a supersonic flow from a nominal Mach 1.5 nozzle have been conducted and characterized.

Clark, Aleksander↗

Non-Contact Vapor Detection of Illicit Drugs via Atmospheric Flow Tube-Mass Spectrometry

Real-time, non-contact detection of illicit drugs is a desirable goal for the interdiction of these controlled substances, but the relatively low vapor pressures of such species present a challenge for trace vapor detection technologies. The introduction of atmospheric flow tube-mass spectrometry (AFT-MS), which has previously been demonstrated to detect gas-phase analytes at low parts-per-quadrillion levels for explosives and organophosphorus compounds, also enables the potential for non-contact drug detection. With AFT-MS, direct vapor detection of cocaine and methamphetamine from ~5 µg residues at room temperature is demonstrated herein. Furthermore, thermal desorption of low- to sub-picogram levels of cocaine, methamphetamine, fentanyl, and heroin is observed via AFT-MS using a carrier flow rate of several L/min of air. These low levels can permit non-contact sampling through collection of vapor, effectively preconcentrating the analyte before desorption and analysis. Quantitative evaluation of the thermal desorption approach has yielded limits of detection (LODs) on order of 10 fg for cocaine and fentanyl, 100 fg for methamphetamine, and 1.6 pg for heroin. The LOD for heroin was lowered to 200 fg by using tributyl phosphate as a dopant to form a proton-bound heterodimer with heroin. When used with AFT-MS, the intentional formation of specific drug-dopant adducts has the potential to enhance detection limits and selectivity of additional drug species. Species that are prone to form adducts present a challenge to analysis, but that difficulty can be overcome by the intentional addition of a dopant. Molecules unlikely to form adducts will remain essentially unimpacted, but the adduct-forming species will interact with the dopant to compress the analyte signal into a single peak. This approach would be valuable in the application of non-contact screening for illicit substances via vapor collection followed by thermal desorption for analysis.

methamphetamine, cocaine, heroin, fentanyl, atmosp↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical modeling of hydrogen mixing in a direct-injection engine fueled with gaseous hydrogen

Hydrogen is considered as one of the most promising options to achieve effective decarbonization of the energy and transportation sectors. As such, it has recently been receiving increasing attention because of its promising potential as an energy carrier for advanced energy and propulsion systems. With a focus on internal combustion engines, direct injection (DI) of gaseous hydrogen during the compression stroke offers great potential for high engine efficiency and specific power while reducing the risk of backfiring and pre-ignition issues. Therefore, many experimental and numerical efforts have recently been dedicated to understanding the physical and chemical behaviors of hydrogen in engine during mixing and combustion. This study focuses on computational fluid dynamics (CFD) modeling of the hydrogen DI process in a hydrogen optical research engine. Under the conditions studied, gaseous hydrogen is injected into the combustion chamber via a centrally located single-hole injector at a pressure of 100 bar. Two configurations, namely low-and high-tumble, are investigated to understand the impact of different in-cylinder flow patterns on the fuel-air mixture preparation. Simulations are carried out using the commercial CFD software CONVERGE. Here, the in-cylinder turbulence is modeled with an unsteady Reynolds-averaged Navier-Stokes (URANS) formulation closed by the renormalization group (RNG) k-ε model. Several numerical methods and model constants, including but not limited to turbulent Schmidt number, are evaluated. The numerical results are systematically compared against experimental measurements of velocity and hydrogen concentration fields on the vertical center plane to assess the performance of the CFD model, unveil the physics of hydrogen mixing, and establish best practices for modeling hydrogen DI under relatively high injection pressure conditions.

33 ADVANCED PROPULSION SYSTEMS↗

MBMS1.0: An Open-Source Code for Modeling and Simulation of Membrane-Based Dehumidification and Energy Recovery

Membrane-based dehumidification is currently being considered as a promising solution for the building application due to its low cost and very limited energy consumption. Developing a simple and efficient open-source code simulation tool is important for boosting the optimization and evaluation of such device in HVAC community. This paper reports a first-order physics based model which accounts for the fundamental heat and mass transfer of humid-air vapor at feed side to flow stream at permeate side. The current model comprises two membrane mass transfer submodels (i.e. microstructure model and performance map model); and it adopts a segment-by-segment methodology for discretizing heat and mass transfer governing equations. The model is capable of simulating both dehumidifiers and energy recovery ventilators with parallel-flow cross-flow, and counter-flow configurations. The model was validated with the measurements at appropriate device. The practices in dehumidification and energy recovery exchangers are also discussed. The model and open-source codes are expected to become a solid fundament for developing a more comprehensive and accurate membrane-based dehumidification in the future.

Gao, Zhiming↗

Development and Porting of Nuclear Reactor Computational Models for the NRIC Virtual Test Bed in FY23

The U.S. DOE’s National Reactor Innovation Center (NRIC) hosts an open-source website and associated GitHub repository called the Virtual Test Bed (VTB) on which computational models for advanced reactors are documented and shared with the reactor community. In FY23 under the NRIC program, computational models for nuclear reactor analysis were developed and contributed to the VTB Github repository during FY23 by contributors at Argonne National Laboratory. Other models developed outside of NRIC were also ported to the VTB as part of this work, serving a broader mission to make computational reactor analysis models more widely available to the reactor community. The model development activities focused on demonstration of gas-cooled microreactor models including computational fluid dynamics simulations of flow through an industry-inspired air jacket design, and simulation of multiphysics transients for a gas-cooled microreactor assembly. Additionally, development of a molten salt reactor (led at Idaho National Laboratory) was supported through Argonne’s expertise in multigroup cross sections generation. Models for these two reactor types were targeted due to their relevancy to NRIC’s Demonstration of Microreactor Experiments (DOME) and Laboratory for Operation and Testing in the U.S. (LOTUS) physical test beds, which are slated to host microreactor and molten salt reactor experiments. The model porting activities consisted of developing detailed documentation for several physics models which originate from the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. We include only contributions from Argonne National Laboratory in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Howard A. Hanson Dam Juvenile Fish Passage and Survival Study Live Fish Injury Assessment, Sensor Fish, and BioPA Modeling Tasks

The live fish injury assessment, Sensor Fish, and BioPA modeling study tasks were conducted by researchers from Pacific Northwest National Laboratory (PNNL). The four tasks were part of the larger Evaluation of Howard A. Hanson Dam (HAHD) Juvenile Fish Passage and Survival study, which had six total tasks. To achieve study objectives for each of the four tasks, field work occurred at Green Peter Dam (GPR) to evaluate the highest elevation steep slope bypass pipe, at HAHD to evaluate baseline conditions of the horseshoe tunnel, and at PNNL’s Aquatic Research Laboratory (ARL) to evaluate simulated dam passage conditions (i.e., shear forces and collision). Each of these evaluations utilized live fish injury assessment, Sensor Fish, and BioPA modeling. Live fish injury assessment and survival (tagged with and without balloon or passive integrated transponder [PIT] tags) was correlated with Sensor Fish to determine thresholds. The CFD analyses were then performed, and the computed values were compared to the corresponding measured values of Sensor Fish data. The results of the overall injury and survival of fish was also used in the validation of the CFD modeling method. Collectively, the results will aid in future modeling of fish passage at HAHD. Results from these tasks can be used by biologists, engineers, resource managers, and regional decision-makers to inform baseline conditions under current operations and the engineering design of the new FPF at HAHD. This draft report contains initial data and results from the four tasks. Table 8 1, Table 8 2, and Table 8 3, and Figure 8 1, Figure 8 2, and Figure 8 3 depict the CFD modeling findings for the GPR steep slope bypass, HAHD horseshoe tunnel, and laboratory testing. Table 8 4, Table 8 5, and Table 8 6 depict the Sensor Fish findings for the GPR steep slope bypass and HAHD horseshoe tunnel testing. The Mv values observed in the HAHD were significantly lower compared to the laboratory experiments conducted at PNNL. Currently, investigations are underway to understand the reasons for this disparity and to establish an appropriate threshold value for Mv. Survival predictions presented in the tables below should be considered preliminary and should not be used until further analyses and adjustments are completed. The next steps for modeling will include the flow regime, (i.e., density of flow regimes due to water and air mixing ) to continue to improve on the threshold value for Mv.

13 HYDRO ENERGY↗

Markov Chain Monte Carlo Parameter Estimation of Deflagration Losses in a Rotating Detonation Engine

One of the practical challenges of the studies of rotating detonation engines (RDEs) is the direct estimation of losses from experimental measurements. This study attempts at resolving this limitation by combining a reduced order model (ROM) of the detonation wave characteristics with a Markov chain Monte Carlo parameter estimation framework. The model considers simple deflagration losses and the overall impact of deflagration on RDE performance. To evaluate this model, a Markov Chain Monte Carlo (MCMC) sampling technique was applied to estimate the loss parameters within the model for a set of conditions operated in hydrogen-air over a range of mass flow rates and equivalence ratios. The MCMC parameter estimation framework allowed for the determination of a posterior distribution of the loss parameters for each test condition, an examination of the correlation between the loss parameters and measured performance metrics of the RDE, and an uncertainty propagation of these parameters. The predicted model loss parameters were then compared to indirect experimental measurements of the deflagration combustion fractions to evaluating the validity of the approach, and shed light on the benefits and drawbacks of the model, measurement techniques, and the estimation framework.

33 ADVANCED PROPULSION SYSTEMS↗

Lawrence Berkley National Laboratory Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence Berkley National Laboratory Building 59 (Raw)

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management. Raw data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗