At least 289 records · Page 16

Toxicity studies of a polyurethane rigid foam

Relative toxicity tests were performed on a polyurethane foam containing a trimethylopropane-based polyol and an organophosphate flame retardant. The routine screening procedure involved the exposure of four Swiss albino male mice in a 4.2 liter hemispherical chamber to the products generated by pyrolyzing a 1.00 g sample at a heating rate of 40 deg C/min from 200 to 800 C in the absence of air flow. In addition to the routine screening, experiments were performed with a very rapid rise to 800 C, with nominal 16 and 48 ml/sec air flow and with varying sample rates. No unusual toxicity was observed with either gradual or rapid pyrolysis to 800 C. Convulsions and seizures similar to those previously reported were observed when the materials were essentially flash pyrolyzed at 800 C in the presence of air flow, and the toxicity appeared unusual because of low sample weights required to produce death.

Hilado, C. J.↗

Thickness and Fuel Preheating Effects on Material Flammability in Microgravity from the BASS Experiment

The Burning and Suppression of Solids (BASS) experiment was performed on the International Space Station. Microgravity combustion tests burning thin and thick flat samples, acrylic spheres, and candles were conducted. The samples were mounted inside a small wind tunnel which could impose air flow speeds up to 40 cms. The wind tunnel was installed in the Microgravity Science Glovebox which supplied power, imaging, and a level of containment. The effects of air flow speed, fuel thickness, fuel preheating, and nitrogen dilution on flame appearance, flame growth, and spread rates were determined in both the opposed and concurrent flow configuration. In some cases, a jet of nitrogen was introduced to attempt to extinguish the flame. Microgravity flames were found to be especially sensitive to air flow speed in the range 0 to 5 cms. The gas phase response is much faster compared to the solid and so as the flow speed is changed, the flame responds with almost no delay. At the lowest speeds examined (less than 1 cms) all the flames tended to become dim blue and very stable. However, heat loss at these very low convective rates is small so the flames can burn for a long time. At moderate flow speeds (between about 1 and 5 cms) the flame continually heats the solid fuel resulting in an increasing fuel temperature, higher rate of fuel vaporization, and a stronger, more luminous flame as time progresses. Only the smallest flames burning acrylic slabs appeared to be adversely influenced by solid conductive heat loss, but even these burned for over 5 minutes before self-extinguishing. This has implications for spacecraft fire safety since a tiny flame might be undetected for a long time. While the small flame is not particularly hazardous if it remains small, the danger is that it might flare up if the air convection is suddenly increased or if the flame spreads into another fuel source.

Combustion↗

Disintegration of liquid sheets

The development, stability, and disintegration of liquid sheets issuing from a two-dimensional air-assisted nozzle is studied. Detailed measurements of mean drop size and velocity are made using a phase Doppler particle analyzer. Without air flow the liquid sheet converges toward the axis as a result of surface tension forces. With airflow a quasi-two-dimensional expanding spray is formed. The air flow causes small variations in sheet thickness to develop into major disturbances with the result that disruption starts before the formation of the main break-up region. In the two-dimensional variable geometry air-blast atomizer, it is shown that the air flow is responsible for the formation of large, ordered, and small chaotic 'cell' structures.

Mansour, Adel↗

Effect of periodic changes of angle of attack on behavior of airfoils

This report presents the results of a series of experiments, which gave some quantitative results on the effect of periodic changes in the direction of the relative air flow against airfoils. The first series of experiments concerned how the angle of attack of the wing model was changed by causing the latter to oscillate about an axis parallel to the span and at right angles to the air flow. The second series embraced all the experiments in which the direction of the air flow itself was periodically changed.

AIRFOILS - ANGLE OF ATTACK↗

Altitude-Wind-Tunnel Investigation of the 19B-2, 19B-8, and 19XB-1 Jet Propulsion Engines: Performance and Windmilling Drag Characteristics - 3

The performance characteristics of the 19B-8 and 19XB-1 turbojet engines and the windmilling-drag characteristics of the 19B-6 engine were determined in the Cleveland altitude wind tunnel. The investigations were conducted on the 19B-8 engine at simulated altitudes from 5000 to 25,000 feet with various free-stream ram-pressure ratios and on the 19XB--1 engine at simulated altitudes from 5000 to 30,000 feet with approximately static free-stream conditions. Data for these two engines are presented to show the effect of altitude, free-stream ram-pressure ratio, and tail-pipe-nozzle area on engine performance. A 21-percent reduction in tail-pipe-nozzle area of the 19B-8 engine increased the let thrust 43 percent the net thrust 72 percent, and the fuel consumption 64 percent. An increase in free-stream ram-pressure ratio raised the jet thrust and the air flow and lowered the net thrust throughout the entire range of engine speeds for the 19B-8 engine. At similar operating conditions, the corrected jet thrust and corrected air flow were approximately the same for both engines, and the corrected specific fuel consumption based on jet thrust was lower for the 19XB-1 engine than for the 19B-8 engine. The thrust and air-flow data obtained with both engines at various altitudes for a given free-stream rampressure ratio were generalized to standard sea-level atmospheric conditions. The performance parameters involving fuel consumption generalized only at high engine speeds at simulated altitudes as high as 15,000 feet. The windmilling drag of the 19B-8 engine increased rapidly as the airspeed was increased.

Fleming, WIlliam A.↗

Influence of Buoyant Convection on the Stability of Enclosed Laminar Flames

Enclosed diffusion flames are commonly found in practical combustion systems, such as the power-plant combustor, gas turbine combustor, and jet engine after-burner. In these systems, fuel is injected into a duct with a co-flowing or cross-flowing air stream. In combustors, this flame is anchored at the burner (i.e., fuel jet inlet) unless adverse conditions cause the flame to lift off or blow out. Investigations of burner stability study the lift off, reattachment, and blow out of the flame. There have been numerous studies of flame stability. Relatively few studies have investigated the stability of flames with an oxidizer co-flow, compared with the number of studies on (nearly) free jet diffusion flames. The air flow around the fuel jet can significantly alter the lift off, reattachment and blow out of the jet diffusion flame. In normal gravity, however, the effects of the air flow on flame stability are often complicated by the presence of buoyant convection. A comparison of normal-gravity and microgravity flames can provide clear indication of the influence of forced and buoyant flows on the flame stability. The overall goal of the Enclosed Laminar Flames (ELF) research, described at the following URL site: http://zeta.lerc.nasa.gov/expr/elf.htm, is to improve our understanding of the effects of buoyant convection on the structure and stability of co-flow diffusion flames.

Brooker, John E.↗

Solid metabolic waste transport and stowage investigation

The basic Waste Collection System (WCS) design under consideration utilized air flow to separate the stool from the WCS user and to transport the fecal material to a slinger device for subsequent deposition on a storage bowel. The major parameters governing stool separation and transport were found to be the area of the air inlet orifices, the configuration of the air inlet orifice and the transport air flow. Separation force and transport velocity of the stool were studied. The developed inlet orifice configuration was found to be an effective design for providing fecal separation and transport. Simulated urine tests and female user tests in zero gravity established air flow rates between 0.08 and 0.25 cu sm/min (3 and 9 scfm) as satisfactory for entrapment, containment and transport of urine using an urinal. The investigation of air drying of fecal material as a substitute for vacuum drying in a WCS breadboard system showed that using baseline conditions anticipated for the shuttle cabin ambient atmosphere, flow rates of 0.14 cu sm/min (5 cfm) were adequate for drying and maintaining biological stability of the fecal material.

Burt, R. A.↗

Character of energy flow in air shower core

Energy per charged particle near the core of air showers was measured by 9 energy flow detectors, which were the combination of Cerenkov counters and scintillators. Energy per particle of each detector was normalized to energy at 2m from the core. The following results were obtained as to the energy flow: (1) integral frequency distribution of mean energy per particle (averaged over 9 detectors) is composed of two groups separated distinctly; and (2) showers contained in one group show an anisotropy of arrival direction.

Mizushima, K.↗

Comparison of High-Speed Images of Lean Blowout for Four National Jet Fuel Combustion Program Fuels

Using the NASA 7-point lean direct injection (LDI) aero gas turbine combustor concept, the effect of fuel composition on lean blowout (LBO) was compared for three National Jet Fuel Combustion Program (NJFCP) fuels and one single-component fuel. The fuels were A-2, an "average" Jet-A with a derived cetane number (DCN) of 49; C-1, which consists primarily of C12 and C16 isoparaffins (Gevo ATJ), with a DCN of 16; C-4, which consists primarily of C9-C16 and C13 isoparaffins (Sasol IPK blended with Gevo), with a DCN of 28; and n-dodecane, with a DCN of 73.5;. Lean blowout was reached by increasing the air flow. Previously-reported results showed the air flow rate at LBO increased with increasing DCN. This presentation examines high speed flame images taken as the flame blew out.

lean blow-out↗

Thermal Management Techniques for Oil-Free Turbomachinery Systems

Tests were performed to evaluate three different methods of utilizing air to provide thermal management control for compliant journal foil air bearings. The effectiveness of the methods was based on bearing bulk temperature and axial thermal gradient reductions during air delivery. The first method utilized direct impingement of air on the inner surface of a hollow test journal during operation. The second, less indirect method achieved heat removal by blowing air inside the test journal to simulate air flowing axially through a hollow, rotating shaft. The third method emulated the most common approach to removing heat by forcing air axially through the bearing s support structure. Internal bearing temperatures were measured with three, type K thermocouples embedded in the bearing that measured general internal temperatures and axial thermal gradients. Testing was performed in a 1 atm, 260 C ambient environment with the bearing operating at 60 krpm and supporting a load of 222 N. Air volumetric flows of 0.06, 0.11, and 0.17 cubic meters per minute at approximately 150 to 200 C were used. The tests indicate that all three methods provide thermal management but at different levels of effectiveness. Axial cooling of the bearing support structure had a greater effect on bulk temperature for each air flow and demonstrated that the thermal gradients could be influenced by the directionality of the air flow. Direct air impingement on the journal's inside surface provided uniform reductions in both bulk temperature and thermal gradients. Similar to the direct method, indirect journal cooling had a uniform cooling effect on both bulk temperatures and thermal gradients but was the least effective of the three methods.

Radil, Kevin↗

Amateur Cleanrooms: Costs May Not Offset Benefits

Contamination and Coatings Branch During my career at NASA, I have encountered a variety of cleanroom systems. With many projects, cost pressures and lack of adequate facilities have forced the managers to resort to amateur cleanrooms to manufacture spacecraft and instruments. These rooms are usually spaces that have been used for other purposes that are converted to cleanroom, usually without the assistance of a contamination control specialist. Often, scientists and engineers are successful in converting an area for experimental use. However, when the area is used for production, countless difficulties are encountered. This paper will document some of the disasters that I have personally witnessed and offer some guidelines for contamination professionals to follow if you are called upon to assist in the development of new cleanrooms. Cleanroom come in all shapes and sizes from special purpose mini-environments (such as flow benches) to large, expansive production facilities. These areas may require a variety of unit operations to be carried out within a short range of each other. The design of the cleanroom should account for compatibilities of these operations to protect the product and personnel. The level of cleanliness has traditionally been associated with the method of ventilation. However, just because and =ea has HEPA filters and greater that 20 air changes per hour does not mean that it is a cleanroom. Airflow is extremely complex; the only way to properly design a cleanroom is through the use of a computer based model. In the aerospace industry, few engineered cleanrooms are modeled. Modeling has been perceived as expensive; however, modern programs and fast computers are changing perception. It is the lack of appreciation for how air flow and location within a cleanroom affects the product that causes most of the problems I have experienced. Currently, the rules defining the best air flow design practices are based on simplistic historical data that are often wrong. The performance of a cleanroom is defined by a set of complex interactions between the airflow, sources of contamination and heat, position of the air terminals and exhausts as well as the objects occupying the space in question. These subtleties are almost never appreciated in the setup of amateur cleanrooms (and sadly, in some engineered cleanroom as well). Experience with the room, measurement of air flows in the room, and black light inspections can be used to

Ramsey, W. Lawrence↗

Altitude-Wind-Tunnel Investigation of the 19B-2, 19B-8 and 19XB-1 Jet- Propulsion Engines: Analysis of Compressor Performance - 4

Investigations were conducted in the Cleveland altitude wind tunnel to determine the performance and operational characteristics of the 19B-2, 19B-8, and 19XS-1 turbojet engines. One objective was to determine the effect of altitude, flight Mach number, and tail-pipe-nozzle area on the performance characteristics of the six-stage and ten-stage axial-flow compressors of the 19B-8 and 19XB-1 engines, respectively, The data were obtained over a range of simulated altitudes and flight Mach numbers. At each simulated flight condition the engine was run over its full operable range of speeds. Performance characteristics of the 19B-8 and 19XB-1 compressors for the range of operation obtainable in the turboJet-engine installation are presented. Compressor characteristics are presented as functions of air flow corrected to sea-level conditions, compressor Mach number, and compressor load coefficient. For the range of compressor operation investigated, changes in Reynolds number had no measurable effect on the relations among compressor Mach number, corrected air flow, compressor load coefficient, compressor pressure ratio, and compressor efficiency. The operating lines for the 19B-8 compressor lay on the low-air-flow side of the region of maximum compressor efficiency; the 19B-8 compressor operated at higher average pressure coefficients per stage and produced a lower over-all pressure ratio than did the 19XB-1 compressor.

Dietz, Robert O.↗

Pressure control valve

A control valve is provided which is adapted to be connected between a pressure source, such as a vacuum pump, and a pressure vessel so as to control the pressure in the vessel. The valve comprises a housing having a longitudinal bore which is connected between the pump and vessel, and a transversely movable valve body which controls the air flow through an air inlet in the housing. The valve body includes cylindrical and conical shaped portions which cooperate with reciprocally shaped portions of the housing to provide flow control. A filter in the air inlet removes foreign matter from the air. The bottom end of the valve body is screwed into the valve housing control knob formed integrally with the valve body and controls translation of the valve body, and the opening and closing of the valve.

Lambson, K. H.↗

Performance of the Bowen ratio systems on a 22 deg slope

The Bowen ratio energy balance technique was used to assess the energy fluxes on inclined surfaces during the First ISLSCP Field Experiment (FIFE). Since air flow over sloping surface may differ from that over flat terrain, it is important to examine whether Bowen ratio measurements taken on sloping surfaces are valid. In this study, the suitability of using the Bowen ratio technique on sloping surfaces was tested by examining the assumptions that the technique requires for valid measurements. This was accomplished by studying the variation of Bowen ratio measurements along a selected slope at the FIFE site. In September 1988, four Bowen ratio systems were set up in a line along the 22 degree north-facing slope with northerly air flow (wind went up the slope). In July of 1989, six Bowen ratio systems were similarly installed with southerly air flow (the wind went down slope). Results indicated that, at distances between 10 to 40 meters from the top of the slope, no temperature or vapor pressure gradient parallel to the slope was detected. Uniform Bowen ratio values were obtained on the slope, and thus the sensible or latent heat flux should be similar along the slope. This indicates that the assumptions for valid flux measurements are reasonably met at the slope. The Bowen ratio technique should give the best estimates of the energy fluxes on slopes similar to that in this study.

Nie, D.↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗

Modeling of a Turbofan Engine with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

The main focus of this study is to apply a computational tool for the flow analysis of the turbine engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center. The PSL has been used to test a highly instrumented Honeywell ALF502R-5A (LF11) turbofan engine at simulated altitude operating conditions. Test data analysis with an engine cycle code and a compressor flow code was conducted to determine the values of key icing parameters, that can indicate the risk of ice accretion, which can lead to engine rollback (un-commanded loss of engine thrust). The full engine aerothermodynamic performance was modeled with the Honeywell Customer Deck specifically created for the ALF502R-5A engine. The mean-line compressor flow analysis code, which includes a code that models the state of the ice crystal, was used to model the air flow through the fan-core and low pressure compressor. The results of the compressor flow analyses included calculations of the ice-water flow rate to air flow rate ratio (IWAR), the local static wet bulb temperature, and the particle melt ratio throughout the flow field. It was found that the assumed particle size had a large effect on the particle melt ratio, and on the local wet bulb temperature. In this study the particle size was varied parametrically to produce a non-zero calculated melt ratio in the exit guide vane (EGV) region of the low pressure compressor (LPC) for the data points that experienced a growth of blockage there, and a subsequent engine called rollback (CRB). At data points where the engine experienced a CRB having the lowest wet bulb temperature of 492 degrees Rankine at the EGV trailing edge, the smallest particle size that produced a non-zero melt ratio (between 3 percent - 4 percent) was on the order of 1 micron. This value of melt ratio was utilized as the target for all other subsequent data points analyzed, while the particle size was varied from 1 micron - 9.5 microns to achieve the target melt ratio. For data points that did not experience a CRB which had static wet bulb temperatures in the EGV region below 492 degrees Rankine, a non-zero melt ratio could not be achieved even with a 1 micron ice particle size. The highest value of static wet bulb temperature for data points that experienced engine CRB was 498 degrees Rankine with a particle size of 9.5 microns. Based on this study of the LF11 engine test data, the range of static wet bulb temperature at the EGV exit for engine CRB was in the narrow range of 492 degrees Rankine - 498 degrees Rankine , while the minimum value of IWAR was 0.002. The rate of blockage growth due to ice accretion and boundary layer growth was estimated by scaling from a known blockage growth rate that was determined in a previous study. These results obtained from the LF11 engine analysis formed the basis of a unique “icing wedge.”

Turbo engine↗

A clean air continuous flow propulsion facility

Consideration is given to a contaminant-free, high enthalpy, continuous flow facility designed to obtain detailed code validation measurements of high speed combustion. The facility encompasses uncontaminated air temperature control to within 5 K, fuel temperature control to 2 K, a ceramic flow straightener, drying of inlet air, and steady state continuous operation. The air heating method provides potential for independent control of contaminant level by injection, mixing, and heating upstream. Particular attention is given to extension of current capability of 1250 K total air temperature, which simulates Scramjet enthalpy at Mach 5.

Krauss, R. H.↗

The Determination of Forces and Moments on a Gimballed SRM Nozzle Using a Cold Flow Model

The Solid Rocket Motor Air Flow Facility (SAF) at NASA Marshall Space Flight Center was used to characterize the flow in the critical aft end and nozzle of a solid propellant rocket motor (SRM) as part of the design phase of development. The SAF is a high pressure, blowdown facility which supplies a controlled flow of air to a subscale model of the internal port and nozzle of a SRM to enable measurement and evaluation of the flow field and surface pressure distributions. The ASRM Aft Section/Nozzle Model is an 8 percent scale model of the 19 second burn time aft port geometry and nozzle of the Advanced Solid Rocket Motor, the now canceled new generation space Shuttle Booster. It has the capability to simulate fixed nozzle gimbal angles of 0, 4, and 8 degrees. The model was tested at full scale motor Reynolds Numbers with extensive surface pressure instrumentation to enable detailed mapping of the surface pressure distributions over the nozzle interior surface, the exterior surface of the nozzle nose and the surface of the simulated propellant grain in the aft motor port. A mathematical analysis and associated numerical procedure were developed to integrate the measured surface pressure distributions to determine the lateral and axial forces on the moveable section of the nozzle, the effective model thrust and the effective aerodynamic thrust vector (as opposed to the geometric nozzle gimbal angle). The nozzle lateral and axial aerodynamic loads and moments about the pivot point are required for design purposes and require complex, three dimensional flow analyses. The alignment of the thrust vector with the nozzle geometric centerline is also a design requirement requiring three dimensional analyses which were supported by this experimental program. The model was tested with all three gimbal angles at three pressure levels to determine Reynolds number effects and reproducibility. This program was successful in demonstrating that a measured surface pressure distribution could be integrated to determine the lateral and axial loads, moments and thrust vector alignment for the scaled model of a large space booster nozzle. Numerical results were provided which are scaleable to the full scale rocket motor and can be used as benchmark data for 3-D CFD analyses.

Whitesides, R. Harold↗