Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

2D photofragmentation LIF imaging of H 2 O 2 and HO 2 in the effluent of an atmospheric-pressure plasma jet: effects of solid and liquid interfaces

Two-dimensional (2D) absolute measurements of hydrogen peroxide (H 2 O 2 ) and approximations of the hydroperoxyl radical (HO 2 ) in the effluent of a COST Reference Microplasma Jet operated with a He/H 2 O feed gas are presented. Gas-phase densities are mapped using photofragmentation laser-induced fluorescence (PF-LIF) under three boundary conditions: open effluent, a solid target, and a liquid target. A novel method is presented for separating PF-LIF signals from H 2 O 2 and HO 2 using comparative measurements in oxygen-rich and oxygen-free environments to exploit the preferential formation of HO 2 in the presence of molecular oxygen. This separation strategy is supported by results from a plug-flow plasma chemistry model. Measured densities agree closely with model predictions in both magnitude and trend, while the 2D experimental distributions provide additional insight into the spatial dependencies of these species. In particular, the results show distinct differences in species transport depending on the target type: solid surfaces induce lateral deflection and reduced centerline densities, whereas liquid interfaces promote axial accumulation and higher near-axis concentrations.

atmospheric-pressure plasma jet (APPJ)↗

Experimental Investigation of Rotating Stall in a Research Multistage Axial Compressor

A collection of experimental data acquired in the NASA low-speed multistage axial compressor while operated in rotating stall is presented in this paper. The compressor was instrumented with high-response wall pressure modules and a static pressure disc probe for in-flow measurement, and a split-fiber probe for simultaneous measurements of velocity magnitude and flow direction. The data acquired to-date have indicated that a single fully developed stall cell rotates about the flow annulus at 50.6% of the rotor speed. The stall phenomenon is substantially periodic at a fixed frequency of 8.29 Hz. It was determined that the rotating stall cell extends throughout the entire compressor, primarily in the axial direction. Spanwise distributions of the instantaneous absolute flow angle, axial and tangential velocity components, and static pressure acquired behind the first rotor are presented in the form of contour plots to visualize different patterns in the outer (midspan to casing) and inner (hub to mid-span) flow annuli during rotating stall. In most of the cases observed, the rotating stall started with a single cell. On occasion, rotating stall started with two emerging stall cells. The root cause of the variable stall cell count is unknown, but is not attributed to operating procedures.

Lepicovsky, Jan↗

Methods and apparatus for determining cardiac output

The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

Cohen, Richard J.↗

Flow pattern and void fraction characterization in nitrogen/water flows through a diamond-type triply periodic minimal surface lattice

Here, this study presents, to the authors knowledge, the first experimental investigation on the void fraction and flow patterns in two-phase flows through a diamond-type Triply Periodic Minimal Surface (TPMS) lattice. An additively manufactured TPMS structure was tested under upward co-current flow of a water/nitrogen mixture. Superficial velocities varied for a total of 42 test conditions (gas: 0.01–2.4 m/s; liquid: 0.01–2.4 m/s; mass flux: 20–2370 kg/m 2 ·s). High-speed video and X-ray imaging enabled time-averaged void fraction measurements and identified six distinct flow regimes which were used to develop a flow pattern map. Comparison of the void fraction data with correlations from literature demonstrated the Rouhani and Axelsson (1970) [49] correlation modified by Steiner (1993) [52] provided the best agreement, which was improved with empirically fit coefficients. This approach predicted the void fraction with errors < ±20% for 64% of the data, with a mean absolute percent deviation (MAPD) of 23%. The measured frictional pressure drop was compared to correlations from literature which captured the observed trends but did not provide good accuracy. The best agreement was found after optimizing the empirical coefficients of the Muller-Steinhagen & Heck (1986) [56] correlation; this approach captured 33% of the data within ±20% with a MAPD of 46% over the full range and captured 71% of the data within ±20% a MAPD of 13.3% at mass fluxes >1100 kg/m 2 -s. These results provide foundational insight into TPMS two-phase flow behavior and inform modeling and design of advanced heat exchange components incorporating TPMS geometries.

42 - ENGINEERING↗

Improved dewpoint-probe calibration

Relatively-simple pressure-control apparatus calibrates dewpoint probes considerably faster than conventional methods, with no loss of accuracy. Technique requires only pressure measurement at each calibration point and single absolute-humidity measurement at beginning of run. Several probes can be calibrated simultaneously and points can be checked above room temperature.

Stephenson, J. G.↗

A polytetrafluorethylene insulated cable for high temperature oxygen aerospace applications

For electrical cables to function and survive in the severe high temperature oxygen environment that will be experienced in the external tanks of the space shuttle, extreme cleanliness and material purity is required. A flexible light weight cable has been developed for use in pure oxygen at worst case temperatures of -190 to +260 degrees Centigrade and pressures as high as 44 pounds per square inch absolute. A comprehensive series of tests were performed on cables manufactured to the best commercial practices in order to establish the basic guidelines for control of build configuration as well as each material used in construction of the cable.

Sheppard, A. T.↗

Investigation of Three Low-temperature-ratio Combustor Configurations in a 48-inch-diameter Ram-jet Engine

A preliminary evaluation was made of three types of combustor configurations in a 48-inch-diameter ram-jet engine to determine the one with the greatest promise of ultimately achieving efficient and stable combustion at low fuel-air rations and low combustor-inlet pressure. The combustor configurations evaluated include (1) a can-piloted configuration using a gutter-type flame holder with can-type pilot burners for stability, (2) an annular-piloted configuration using a gutter-type flame holder with an annular pilot burner to provide stability and to serve as a flow divider for confined fuel-air mixing, and (3) a can-type configuration using a flow divider for confined fuel-air mixing. No modifications were made to optimize the performance of any configuration. On the basis of this preliminary evaluation at an inlet-air temperature of about 990 degrees R, the annular-piloted combustor configuration appeared to have the greatest promise of permitting combustion efficiencies in excess of 0.90 at low fuel-air ratio with combustor-inlet pressures as low as 700 pounds per square foot absolute.

COMBUSTION - RAM-JET ENGINES↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

Engine performance and the determination of absolute ceiling

This report contains a brief study of the variation of engine power with temperature and pressure. The variation of propeller efficiency in standard atmosphere is obtained from the general efficiency curve which is developed in NACA report no. 168. The variation of both power available and power required are then determined and curves plotted, so that the absolute ceiling may be read directly from any known sea-level value of the ratio of power available to power required.

Diehl, Walter S↗

Laser Flash Photolysis Studies of Radical-Radical Reaction Kinetics: The O((sup 3)P(sub J)) + BrO Reaction

A novel dual laser flash photolysis-long path absorption-resonance fluorescence technique has been employed to study the kinetics of the important stratospheric reaction 0((sup 3)P(sub j)) + Br yields(k1) BrO((sup 2)P(sub J)) + O2 as a function of temperature (231-328 K) and pressure (25-150 Torr) in N2 buffer gas. The experimental approach preserves the principal advantages of the flash photolysis method, i.e., complete absence of surface reactions and a wide range of accessible pressures, but also employs techniques which are characteristic of the discharge flow method, namely chemical titration as a means for deducing the absolute concentration of a radical reactant and use of multiple detection axes. We find that k1 is independent of pressure, and that the temperature dependence of k1 is adequately described by the Arrhenius expression k1(T) = 1.91 x 10(exp -11)(230/J) cu cm/ molecule.s; the absolute accuracy of measured values for k1 is estimated to vary from +/- 20 percent at at T approximately 230 K to +/- 30 percent at T approximately 330 K. Our results demonstrate that the O((sup 3)P(sub j)) + BrO rate coefficient is significantly faster than previously 'guesstimated,' and suggest that the catalytic cycle with the O((sup 3)P(sub j)) + BrO reaction as its rate-limiting step is the dominant stratospheric BrO(x), odd-oxygen destruction cycle at altitudes above 24 km.

Thorn, R. P.↗

Stand Alone Pressure Measurement Device (SAPMD) for the space shuttle Orbiter, part 1

The specifications for the Stand Alone Pressure Measurement Device (SAPMD) are as follows: the SAPMD shall measure ambient pressure at the surface of the Orbiter TPS in the range of 0 to 15 pounds per square inch absolute (PSIA). Measurement will begin at solid rocket booster (SRB) ignition as sensed by appropriate vibration sensing elements in the SAPMD. Pressure and corresponding real-time data are to be recorded every one tenth second for 140 seconds and at the end of the recording period, the operation will be discontinued with the data preserved for interrogation subsequent to Orbiter re-entry and landing. The type and size of the battery shall be such as to allow the vibration sensing elements and a real-time clock to be initialized a minimum of 30 day prior to launch and still provide power as necessary to perform the 140 second data recording period after SRB ignition. Battery installation shall be in such a manner as to allow battery replacement without removing the SAPMD from its position or removing more than one TPS tile. The SAPMD must be mounted in specific locations under tile of the TPS. To accommodate such mounting, the absolute maximum physical dimensions much not exceed 6.0 inches in length, 1.5 inches in width, and 0.4 inches in height, and the device shall be of such configuration that it can be bonded to the Orbiter skin at the joint line of two TPS tiles with the pressure sensing port at the surface of the tile. The SAPMD must remain operational in the temperature range of -40 to +85 C and survive storage temperature of -55 to +125 C. The pressure port must withstand 934 C without causing damage to the TPS during entry and must remain functional at 262 C during ascent. The accuracy of the pressure measurement must be plus or minus one-half PSIA over a temperature range of 0 to +36 C. All the specifications were met and verified by prototype testing and documented in the enclosed test data. Four flight-qualified models were fabricated and of these, two were delivered and successfully flown in the cargo bay of STS-26.

Tomlinson, Bill↗

The erosion/corrosion of small superalloy turbine rotors operating in the effluent of a PFB coal combustor

Superalloy turbine rotors in a single stage turbine with 6 percent partial admittance were operated in the effluent of a pressurized fluidized bed coal combustor for up to 164 hours. Total mass flow was 300 kg/hr and average particulate loadings ranged from 600 to 2800 ppm for several coal/sorbent combinations. A 5.5 atm turbine inlet gas pressure and inlet gas temperatures from 700 to 800 C yielded absolute gas velocities at the stator exit of about 500 m/s. The angular rotation speed (40,000 rpm) of the six inch diameter rotors was equivalent to a tip speed of about 300 m/s, and average gas velocities relative to the rotating surface ranged from 260 to 330 m/s at mean radius. The rotor erosion pattern reflects heavy particle separation with severe (5 to 500 cm/yr) erosion at the leading edge, pressure side center, and suction side trailing edge at the tip. The erosion distribution pattern provides a spectrum of erosion/oxidation/deposition as a function of blade position. This spectrum includes enhanced oxidation (10 to 100 x air), mixed oxides in exposed depletion zones, sulfur rich oxides in deposition zones, and rugged areas of erosive oxide removal.

Zellars, G. R.↗

Correction for Neutral Pressure-Driven Signal in Radiated Power Measurements on Proto-MPEX

A pinhole camera using four-channel resistive bolometers was designed and implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to measure the plasma radiated power. Quantification of the radiated power is required for comprehensive power balance assessments but faces unique challenges on linear plasma devices due to weak absolute signal, compared to typical use in toroidal fusion plasmas, and high neutral pressure changes. Around 1 mTorr, the pressure-driven signal contribution was shown to overwhelm the radiated power signal in Proto-MPEX, found to be ~3 μW . Since the pressure-driven signals could not be predicted from first principle arguments, the signals were corrected using empirical models that take two experimental pressure measurements and the raw bolometer signal to reveal the radiated power signals. Four “gas-only” Proto-MPEX shots were taken, without the radio frequency (rf) plasma discharge, to train, optimize, and validate empirical models. The data included two pressure measurements at different locations along with the bolometer signal. Multiple models were tested; partial least-squares regression with a cross correlation method to account for the time offset in the pressure measurements provided the best combination of accuracy and stability. The model was validated to have a modeling error of 0.0036 V, which was lower than 10% of the expected radiated power signal. The model was tested on a different “gas-only” shot with a complete time-series data. For plasma operation shots, the corrected bolometer measurements were compared with an absolute extreme ultraviolet photodiode measurement and similarities and differences are discussed.

Lee, Seungsup↗

Piston manometer as an absolute standard for vacuum gage calibration in the range 10 to 700 microtorr

Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).

Warshawsky, I.↗

Solubility of K in Fe-S liquid, silicate-K/Fe-S/liq equilibria, and their planetary implications

Potassium has been found to have extremely limited absolute solubility in Fe-S liquid in the pressure-temperature range of 18 to 40 kbars, 1050 to 1150 C, and fO2 within the field of metallic iron. It also partitioned into a certain silicate phase highly in preference to Fe-S liquid at 30 kbar and 1100 C. The dependence of the partitioning of K between solid silicate and Fe-S liquid on fO2 and compositions of mineral solid solutions have been analyzed. These experimental data, along with those of others, limit the amount of K that could fractionate in Fe-S liquid layers or a core in the early history of the moon and, thus, act as localized heat sources in its thermal history models; the data also seem to argue against a chondritic abundance of potassium for earth. The question of fractionation of enough K-40 in an Fe-S liquid outer core of earth to provide the necesary thermal energy for the geomagnetic dynamo remains unresolved.

Gangully, J.↗

The energy balance of the solar transition region

It is shown how the observed distribution of the emission measure with temperature can be used to limit the range of energy deposition functions suitable for heating the solar transition region and inner corona. The minimum energy loss solution is considered in view of the work by Hearn (1975) in order to establish further scaling laws between the transition region pressure, the maximum coronal temperature and the parameter giving the absolute value of the emission measure. Also discussed is the absence of a static energy balance at the base of the transition region in terms of measurable atmospheric parameters, and the condition for a static energy balance is given. In addition, the possible role of the emission from He II in stabilizing the atmosphere by providing enhanced radiation loss is considered.

Jordan, C.↗

Computer code for preliminary sizing analysis of axial-flow turbines

This mean diameter flow analysis uses a stage average velocity diagram as the basis for the computational efficiency. Input design requirements include power or pressure ratio, flow rate, temperature, pressure, and rotative speed. Turbine designs are generated for any specified number of stages and for any of three types of velocity diagrams (symmetrical, zero exit swirl, or impulse) or for any specified stage swirl split. Exit turning vanes can be included in the design. The program output includes inlet and exit annulus dimensions, exit temperature and pressure, total and static efficiencies, flow angles, and last stage absolute and relative Mach numbers. An analysis is presented along with a description of the computer program input and output with sample cases. The analysis and code presented herein are modifications of those described in NASA-TN-D-6702. These modifications improve modeling rigor and extend code applicability.

Glassman, Arthur J.↗

A note on secondary flow in rotating radial channels

A general vector differential equation for the vorticity component parallel to a streamline is derived for steady, nonviscous, and incompressible flow in a rotating system. This equation is then simplified by restricting it to rotating radial channels and by making further simplifying assumptions. The simplified equation is used to solve for the secondary vorticity, the vorticity component parallel to the streamline, in three special cases involving different streamtube geometries; the results are presented in a series of figures. The secondary vorticity is shown to decrease with decreased absolute angular velocity of the fluid, decreased inlet total-pressure gradient, decreased length of relative flow path, and increased relative velocity.

Kramer, James J↗