Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Electron-radiation effects on the ac and dc electrical properties and unpaired electron densities of three aerospace polymers

The effects of gigarad-level total absorbed doses from 1-MeV electrons on the post-irradiation alternating-current (ac) and direct-current (dc) electrical properties and the unpaired electron densities have been studied for Kapton, Ultem, and Mylar. The unpaired electron densities (determined from electron paramagnetic resonance spectroscopy) and the dc electrical conductivities of the irradiated materials were monitored as functions of time following the exposures to determine their decay characteristics at room temperature. The elevated-temperature ac electrical dissipations of the Ultem and Mylar were affected by the radiation. The dc conductivity of the Kapton increased by five orders of magnitude, while the dc conductivities of the Ultem and Mylar increased by less than an order of magnitude, due to the radiation. The observed radiation-generated changes in the ac electrical dissipations are explained in terms of known radiation-generated changes in the molecular structures of the three materials. A preliminary model relating the dc electrical conductivity and the unpaired electron density in the Kapton is proposed.

Long, Sheila Ann T.↗

An electrochemical study of corrosion protection by primer-topcoat systems on 4130 steel with ac impedance and dc methods

To investigate metal surface corrosion and the breakdown of metal protective coatings, the ac impedance method is applied to six systems of primer coated and primer topcoated 4130 steel. Two primers were used: a zinc-rich epoxy primer and a red lead oxide epoxy primer. The epoxy-polyamine topcoat was used in four of the systems. The EG and G-PARC Model 368 ac impedance measurement system, along with dc measurements with the same system using the polarization resistance method, were used to monitor changing properties of coated 4230 steel disks immersed in 3.5 percent NaCl solutions buffered at pH 5.4 over periods of 40 to 60 days. The corrosion system can be represented by an electronic analog called an equivalent circuit consisting of resistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for the resistors and capacitors, that can be assigned in the equivalent circuit following a least-squares analysis of the data, describe changes that occur on the corroding metal surface and in the protective coatings. Two equivalent circuits have been determined that predict the correct Bode phase and magnitude of the experimental sample at different immersion times. The dc corrosion current density data are related to equivalent circuit element parameters. Methods for determining corrosion rate with ac impedance parameters are verified by the dc method.

Mendrek, M. J.↗

Development of a computer algorithm for the analysis of variable-frequency AC drives: Case studies included

The development of computer software for performance prediction and analysis of voltage-fed, variable-frequency AC drives for space power applications is discussed. The AC drives discussed include the pulse width modulated inverter (PWMI), a six-step inverter and the pulse density modulated inverter (PDMI), each individually connected to a wound-rotor induction motor. Various d-q transformation models of the induction motor are incorporated for user-selection of the most applicable model for the intended purpose. Simulation results of selected AC drives correlate satisfactorily with published results. Future additions to the algorithm are indicated. These improvements should enhance the applicability of the computer program to the design and analysis of space power systems.

Kankam, M. David↗

Development of software to improve AC power quality on large spacecraft

To insure the reliability of a 20 kHz, AC power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can cause malfunctions in equipment that the power system is supplying, and during extreme distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. HARMFLO, a power flow computer program, which was capable of analyzing harmonic conditions on three phase, balanced, 60 Hz, AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The results are that (1) the harmonic power now has a model of a single phase, voltage controlled, full wave rectifier; and (2) HARMFLO was ported to the SUN workstation platform.

Kraft, L. Alan↗

Electromechanical systems with transient high power response operating from a resonant ac link

The combination of an inherently robust asynchronous (induction) electrical machine with the rapid control of energy provided by a high frequency resonant ac link enables the efficient management of higher power levels with greater versatility. This could have a variety of applications from launch vehicles to all-electric automobiles. These types of systems utilize a machine which is operated by independent control of both the voltage and frequency. This is made possible by using an indirect field-oriented control method which allows instantaneous torque control all four operating quadrants. Incorporating the ac link allows the converter in these systems to switch at the zero crossing of every half cycle of the ac waveform. This zero loss switching of the link allows rapid energy variations to be achieved without the usual frequency proportional switching loss. Several field-oriented control systems were developed under contract to NASA.

Burrows, Linda M.↗

Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

Hull, Gary↗

Max Launch Abort System (MLAS) Pad Abort Test Vehicle (PATV) II Attitude Control System (ACS) Integration and Pressurization Subsystem Dynamic Random Vibration Analysis

In order to mitigate catastrophic failures on future generation space vehicles, engineers at the National Aeronautics and Space Administration have begun to integrate a novel crew abort systems that could pull a crew module away in case of an emergency at the launch pad or during ascent. The Max Launch Abort System (MLAS) is a recent test vehicle that was designed as an alternative to the baseline Orion Launch Abort System (LAS) to demonstrate the performance of a "tower-less" LAS configuration under abort conditions. The MLAS II test vehicle will execute a propulsive coast stabilization maneuver during abort to control the vehicles trajectory and thrust. To accomplish this, the spacecraft will integrate an Attitude Control System (ACS) with eight hypergolic monomethyl hydrazine liquid propulsion engines that are capable of operating in a quick pulsing mode. Two main elements of the ACS include a propellant distribution subsystem and a pressurization subsystem to regulate the flow of pressurized gas to the propellant tanks and the engines. The CAD assembly of the Attitude Control System (ACS) was configured and integrated into the Launch Abort Vehicle (LAV) design. A dynamic random vibration analysis was conducted on the Main Propulsion System (MPS) helium pressurization panels to assess the response of the panel and its components under increased gravitational acceleration loads during flight. The results indicated that the panels fundamental and natural frequencies were farther from the maximum Acceleration Spectral Density (ASD) vibrations which were in the range of 150-300 Hz. These values will direct how the components will be packaged in the vehicle to reduce the effects high gravitational loads.

Ekrami, Yasamin↗

Study of the Dependence on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.

Bandler, Simon↗

Enhancement of the AC RPA

The overall goal of this research project is to improve the response and sensitivity of the AC Retarding Potential Analyzer (RPA). The AC RPA can accurately measure the flux, energy, and energy distribution of charged particles in a space environment. The enhancement of the sensor derives from changes that increase sensitivity of flux measurements through reduction of the baseline noise. The enhanced AC RPA sensor allows diagnosis of required charge particle beams necessary for tests of materials, instruments and subsystems, for future exploration missions.

Israel, Mordecai Ben↗

Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

A system is provided for controlling two alternating current (AC) machines via a five-phase PWM inverter module. The system comprises a first control loop, a second control loop, and a current command adjustment module. The current command adjustment module operates in conjunction with the first control loop and the second control loop to continuously adjust current command signals that control the first AC machine and the second AC machine such that they share the input voltage available to them without compromising the target mechanical output power of either machine. This way, even when the phase voltage available to either one of the machines decreases, that machine outputs its target mechanical output power.

42 ENGINEERING↗

Security-Constrained Unit Commitment with Linearized AC Optimal Power Flow.

We propose a mathematical programming-based approach to optimize the security-constrained unit commitment problem with a full AC transmission network representation. Our approach is based on our previously introduced successive linear programming (SLP) approach to solving the non-linear, nonconvex AC optimal power flow (ACOPF) problem. By linearizing the ACOPF, we are able to leverage powerful commercial mixed-integer solvers to iteratively optimize the combined unit commitment plus ACOPF model. We demonstrate our approach on six-bus, IEEE RTS-96, and IEEE 118-bus test systems. We perform a comparative analysis of the relative impacts of singlebus, DC, and AC transmission network models on the unit commitment and dispatch solutions and their associated costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual magnetic phase material rings for AC electric machines

An AC electric machine that includes a dual magnetic phase material ring is disclosed. The AC electric machine includes a stator assembly and a rotor assembly positioned within the stator assembly and configured to rotate relative thereto, the rotor assembly comprising a rotor core including a stack of rotor laminations that collectively form the rotor core, the rotor core including a plurality of rotor poles separated by gaps therebetween. The AC electric machine also includes a dual magnetic phase material ring positioned about the stack of rotor laminations, the dual magnetic phase material ring comprising a first ring portion comprising a magnetic portion and a second ring portion comprising a non-magnetic portion.

42 ENGINEERING↗

Programmable AC power supply for simulating power transient expected in fusion reactor

This paper focus on control engineering of the programmable AC power source which has capability to simulate power transient expected in fusion reactor. To generate the programmable power source, AC-AC power electronics converter is adopted to control the power of a set of heaters to represent the transient phenomena of heat exchangers or heat sources of a fusion reactor. The International Thermonuclear Experimental Reactor (ITER) plasma operation scenario is used as the basic reference for producing this transient power source. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Segmented superconducting tape having reduced AC losses and method of making

A superconducting tape having reduced AC losses. The tape has a high temperature superconductor layer that is segmented. Disruptive strips, formed in one of the tape substrate, a buffer layer, and the superconducting layer create parallel discontinuities in the superconducting layer that separate the current-carrying elements of the superconducting layer into strips or filament-like structures. Segmentation of the current-carrying elements has the effect of reducing AC current losses. Methods of making such a superconducting tape and reducing AC losses in such tapes are also disclosed.

36 MATERIALS SCIENCE↗

AC and Impulse Breakdown of Liquid Nitrogen at 77 K for Quasi-Uniform Field Gaps

Liquid nitrogen (LN2) is commonly used both as a coolant and electrical insulation in high temperature superconductor (HTS) equipment for power applications. Hence it is necessary to know the electrical breakdown characteristics of LN2 under a variety of conditions which are likely to be encountered in practice. The ac breakdown and positive and negative polarity breakdown results for lightning impulse (1.2 microsecond rise time/50 microsecond fall time) are presented for LN2 using sphere to plane electrode geometry for sphere diameters of 50.8 and 101.6 mm over a gap range of 1 to 15 mm. Voltages up to 110 kVrms were studied for ac breakdown and up to 500-kV peak for impulse. In this work both the ac and impulse breakdown voltages scale approximately with distance over the limited gaps studied which is indicative of a quasi-uniform (near- uniform) electric field between sphere and plane. These measurements were conducted in a dewar which could be pressurized from 1 to 2 bar absolute which greatly reduces the spontaneous formation of bubbles that can occur in open LN2 bath experiments and thus potentially reduce the breakdown strength. Results from the pressurized system and near atmospheric pressure similar to an open bath are compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signal quality of the LHC AC dipoles and its impact on beam dynamics

The adiabaticity of the AC dipole might be compromised by noise or unwanted frequency components in its signal. An effort has been put to characterize and optimize the signal quality of the LHC AC dipoles. The measured signal is used in realistic simulations in order to evaluate its impact on beam dynamics and to ultimately establish safe margins for the operation of the LHC AC dipoles.

43 PARTICLE ACCELERATORS↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation on Effect of Magnetic Field Dependency Coefficient of Critical Current Density on the AC Magnetizing Loss in HTS Tapes Exposed to External Field

High-temperature superconducting (HTS) technology is the most promising, advanced, and beneficial technological developments of the last two decades in terms of fabricating more efficient, compact, and reliable electrical power apparatus. The second-generation HTS wires are now quite competitive with traditional conductors from the cost point of view. In addition, they are of high interest in electrical machine manufacturing due to their unique merits such as high current density, high magnetic field, and low loss. The most significant issue for any superconducting devices which work with alternating current or magnetic field is the AC loss of the HTS tapes. Since HTS tapes are always exposed to an external magnetic field in electrical machine applications, it is vital to consider the effect of this external field on their AC magnetizing (ACMG) loss. It is well-known that external magnetic field decreases the current carrying capability of the wire. In real life, critical current density of HTS tapes is dependent to magnetic field but this dependency sometime was not considered in modeling stage in order to make it faster and simple. In this paper, the electromagnetic properties of HTS tapes for use in superconducting electric machines have been investigated with a particular focus on the ACMG loss of YBCO tapes. For this purpose, a two-dimensional finite element model has been implemented based on the H formulation in order to study the effect of dependency of critical current density to magnetic field on the variation of ACMG loss. The modeling results will be helpful for electrical machine designers to have a better understanding about this effect and have a more accurate estimate of ACMG loss in design stage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗