Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Capture Cross Section Measurements in {sup nat}Fe and {sup 181}Ta from 1 to 2000 keV Using a New C6D6 Detector Array

A new array of four C6D6 detectors has been developed at the Rensselaer Polytechnic Institute Gaerttner LINAC center for the purposes of measuring neutron capture cross sections in the keV resonance region with low sensitivity to scattered neutrons. The new detection apparatus incorporates low-mass, low cross-section materials to reduce neutron sensitivity, and uses digital data acquisition equipment to enable saving of the full waveform output of each detector module for offline analysis. Capture yields are determined by applying the total energy method and pulse height weighting technique during the analysis of the saved data. Measurements have been performed on samples of iron and tantalum using the new system, with results consistent with existing data libraries. (authors)

42 ENGINEERING↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗

Note: Recent achievements at the 60-MeV Linac for sub-picosecond terahertz radiation at the Pohang Accelerator Laboratory

A femtosecond (fs) terahertz (THz) linac has been constructed to generate fs-THz radiation by using ultrashort electron beam at the Pohang Accelerator Laboratory. To generate an ultrashort electron beam with 60-MeV energy, a chicane bunch compressor has been adopted. Simulation studies have been conducted to design the linac. In this note, recent achievements at 60-MeV linac are presented.

43 PARTICLE ACCELERATORS↗

Note: Emittance measurements of intense pulsed proton beam for different pulse length and repetition rate

The high intensity ion source (SILHI), in operation at CEA-Saclay, has been used to produce a 90 mA pulsed proton beam with pulse length and repetition rates suitable for the European Spallation Source (ESS) linac. Typical r-r{sup '} rms normalized emittance values smaller than 0.2{pi} mm mrad have been measured for operation in pulsed mode (0.01 < duty cycle < 0.15 and 1 ms < pulse duration < 10 ms) that are relevant for the design update of the Linac to be used at the ESS in Lund.

43 PARTICLE ACCELERATORS↗

R and D toward a compact high-brilliance X-ray source based on channeling radiation

X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B{approx} 10{sup 12} photons.(mm-mrd){sup -2}. (0.1% BW){sup -1}.s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

43 PARTICLE ACCELERATORS↗

The Klynac: An integrated klystron and linear accelerator

The Klynac concept integrates an electron gun, a radio frequency (RF) power source, and a coupled-cavity linear accelerator into a single resonant system. The klystron is essentially a conventional klystron structure with an input cavity, some number of intermediate cavities and an output cavity. The accelerator structure is, likewise, a conventional on-axis coupled structure. The uniqueness is the means of coupling the klystron output cavity to the accelerator. The coupler is a resonant coupler rather than an ordinary transmission line. The geometry of such a system need not be coaxial. However, if the klystron and accelerator are coaxial we can eliminate the need for a separate cathode for the accelerator by injecting some of the klystron beam into the accelerator. Such a device can be made cylindrical which is ideal for some applications.

43 PARTICLE ACCELERATORS↗

Note: Neutron shutter for Kolkata superconducting cyclotron

In particle accelerator facilities, experimental areas are isolated from active accelerator area with thick concrete walls. A neutron shutter is used to isolate the experimental areas from the active accelerator area in the beam line. These shutters are provided primarily to reduce the secondary radiations like neutrons in the experimental areas to permissible limit when the primary beam is blocked in the accelerator area. The reduced radiation level in the experimental areas makes the experimental areas accessible. The shutters should allow the primary beam to pass to the experimental caves when they retracted from the beam line. A new neutron shutter has been designed and fabricated. This shutter incorporates compact features with considerable reduction in length, surface area and volume. The attenuation of secondary radiations is evaluated using Monte-Carlo radiation transport code FLUKA. It is found that the features of the shutter are sufficiently good enough to reduce the diffused secondary radiations well within the permissible levels.

43 PARTICLE ACCELERATORS↗

Design of a high-power, high-gain, 2nd harmonic, 22.848 GHz gyroklystron

In this paper we consider the design of a four-cavity, high-gain K-band gyroklystron experiment for high gradient structure testing. The frequency doubling gyroklystron utilizes a beam voltage of 500 kV and a beam current of 200 A from a magnetron injection gun (MIG) originally designed for a lower-frequency device. The microwave circuit features input and gain cavities in the circular TE{sub 011} mode and penultimate and output cavities that operate at the second harmonic in the TE{sub 021} mode. We investigate the MIG performance and study the behavior of the circuit for different values of perpendicular to parallel velocity ratio (α= V{sub ⊥}/ V{sub z}). This microwave tube is expected to be able to produce at least 20 MW of power in 1μs pulses at a repetition rate of at least 120 Hz. A maximum efficiency of 26% and a large signal gain of 58 dB under zero-drive stable conditions were simulated for a velocity ratio equal to 1.35.

43 PARTICLE ACCELERATORS↗

A compact 10 kW, 476 MHz solid state radio frequency amplifier for pre-buncher cavity of free electron laser injector linear accelerator

A 10 kW, 476 MHz, 0.1% duty cycle solid state RF amplifier system for driving sub-harmonic, pre-buncher cavity of IR-FEL injector LINAC, has been developed at RRCAT. The 10 kW power is achieved by combining output of eight 1400 W amplifier modules using 8-way planar corporate combiner. The solid state amplifier modules have been developed using 50 V RF LDMOS transistors which although meant for push-pull operation are being used in single ended configuration with matching circuit developed on a thin (25 mils), high dielectric constant (9.7), low loss microwave laminate with an aim to have a compact structure. Ease of fabrication, modularity, small size, and low cost are the important features of this design which could be used as a template for low duty cycle medium to high pulsed power UHF amplifier system.

43 PARTICLE ACCELERATORS↗

Cryo-technical design aspects of the superconducting SIS100 quadrupole doublet modules

The FAIR project was initiated to build an international accelerator and experimental facility for basic research activities in various fields of modern physics. The core component of the project will be the SIS100 heavy ion accelerator, producing heavy ion beams of uniquely high intensities and qualities. The superconducting main quadrupoles and corrector magnets are assembled within complex quadrupole doublet modules (QDMs), combining two superconducting quadrupole (focusing and defocusing), sextupole and steering magnets in one cryostat. In addition a cryo-catcher, a beam position monitor and a cold beam pipe will be integrated. In accordance with the magnet lattice structure, the QDM series for the SIS100 consists of four main families composed of eleven different configurations. The common technical feature of all configurations is a sophisticated common girder structure, mechanically integrating all functional components in one cold mass and being suspended in a corresponding cryostat system. The requirements to position preservation during thermal cycling are to be fulfilled by a precise and stable support of the functional elements, as well as by a reliable, reproducible and stable cold mass suspension system. The main design aspects of the QDMs will be discussed as a result of these requirements.

43 PARTICLE ACCELERATORS↗

Overview of the Neutrinos from Stored Muons Facility - nuSTORM

Neutrino beams produced from the decay of muons in a racetrack-like decay ring (the so called Neutrino Factory) provide a powerful way to study neutrino oscillation physics and, in addition, provide unique beams for neutrino interaction studies. The Neutrinos from STORed Muons (nuSTORM) facility uses a neutrino factory-like design. Due to the particular nature of nuSTORM, it can also provide an intense, very pure, muon neutrino beam from pion decay. This so-called 'Neo-conventional' muon-neutrino beam from nuSTORM makes nuSTORM a hybrid neutrino factory. Here in this paper we describe the facility and give a detailed description of the neutrino beams that are available and the precision to which they can be characterized. We then show its potential for a neutrino interaction physics program and present sensitivity plots that indicate how well the facility can perform for short-baseline oscillation searches. Lastly, we comment on the performance potential of a 'Neo-conventional' muon neutrino beam optimized for long-baseline neutrino-oscillation physics.

43 PARTICLE ACCELERATORS↗

Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE): Conceptual Design Report. Volume 3: Long-Baseline Neutrino Facility for DUNE

This volume of the LBNF/DUNE Conceptual Design Report covers the Long-Baseline Neutrino Facility for DUNE and describes the LBNF Project, which includes design and construction of the beamline at Fermilab, the conventional facilities at both Fermilab and SURF, and the cryostat and cryogenics infrastructure required for the DUNE far detector.

43 PARTICLE ACCELERATORS↗

Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device

The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows. During gettering, the vacuum optics were retracted and isolated behind a gate valve permitting their removal if cleaning was necessary. The axial view incorporated a stainless-steel mirror in a protective cap assembly attached to the vacuum-side of the viewport. For each system, a custom lens-based, high-throughput optical periscope was designed to relay the plasma image about half a meter to a high-speed camera. Each instrument also contained a remote-controlled filter wheel, set between shots to isolate a particular hydrogen or impurity emission line. The design of the camera platform, imaging performance, and sample data for each view is presented.

43 PARTICLE ACCELERATORS↗

Fermilab Program and Plans

This article is a short summary of the talk presented at 2014 Instrumentation Conference in Novosibirsk about Fermilab's experimental program and future plans. It includes brief description of the P5 long term planning progressing in US as well as discussion of the future accelerators considered at Fermilab.

43 PARTICLE ACCELERATORS↗

Upgrade of High-Energy X-Ray real-time radioscopy for KROTOS experiment

As part of its R and D programs on severe accidents, in particular on understanding of corium-water interaction, CEA is commissioning an update of the KROTOS experiment at Cadarache. The Xray imaging setup (high energy real-time radioscopy) is upgraded to provide the best performances for the new experimental program. In order to fit the performance needs (faster acquisition, smaller detection limit and higher field of view), two radioscopy setups, with two linear accelerators (linacs 9 MV and 6 MV), are placed in the irradiation cell. Having discussed the expected performances in terms of frequency, detection limit and field-of-view, this article details each stage of both radioscopy chains: principles and technical characteristics. Then, linacs and cameras synchronization (at few hundred Hertz), data flows and storage setups are detailed. Finally, experimental characterizations and performance validations on phantom are presented. (authors)

43 PARTICLE ACCELERATORS↗

A low energy beam transport system for proton beam

A low energy beam transport (LEBT) system has been built for a compact pulsed hadron source (CPHS) at Tsinghua University in China. The LEBT, consisting of two solenoids and three short-drift sections, transports a pulsed proton beam of 60 mA of energy of 50 keV to the entrance of a radio frequency quadrupole (RFQ). Measurement has shown a normalized RMS beam emittance less than 0.2 {pi} mm mrad at the end of the LEBT. Beam simulations were carried out to compare with the measurement and are in good agreement. Based on the successful CPHS LEBT development, a new LEBT for a China ADS projector has been designed. The features of the new design, including a beam chopper and beam simulations of the LEBT are presented and discussed along with CPHS LEBT development in this article.

43 PARTICLE ACCELERATORS↗