Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Modeling rarefied gas chemistry with QuiPS, a novel quasi-particle method

The goal of this work is to build up the capability of quasi-particle simulation (QuiPS), a novel flow solver, such that it can adequately model the rarefied portion of an atmospheric reentry trajectory. Direct simulation Monte Carlo (DSMC) is the conventional solver for such conditions, but struggles to resolve transient flows, trace species, and high-level internal energy states due to stochastic noise. Quasi-particle simulation (QuiPS) is a novel Boltzmann solver that describes a system with a discretized, truncated velocity distribution function. The resulting fixed-velocity, variable weight quasi-particles enable smooth variation of macroscopic properties. The distribution function description enables the use of a variance-reduced collision model, greatly minimizing expense near equilibrium. This work presents the addition of a neutral air chemistry model to QuiPS and some demonstrative 0D simulations. The explicit representation of internal distributions in QuiPS reveals some of the flaws in existing physics models. Overall, variance reduction, a key feature of QuiPS, can greatly reduce expense of multi-dimensional calculations, but is only cheaper when the gas composition is near chemical equilibrium.

42 ENGINEERING↗

A Partial Coupling Method to Isolate the Roles of the Atmosphere and Ocean in Coupled Climate Simulations

This study describes the formulation and application of a partial coupling method that disentangles the coupling between the atmosphere and ocean and isolates the atmosphere- and ocean-driven components of the coupled climate interactions. In contrast to strategies using stand-alone simulations with prescribed atmosphere or ocean states, the climate components in the partially coupled method remain coupled, but the impact of ocean circulation changes is removed from the air-sea interaction using temperature-like tracers. The partially coupled simulation thereby suppresses the ocean-driven interaction and isolates an atmosphere-driven interaction only. The ocean-driven component can be inferred by comparing climate response in the partially coupled simulation with that of a standard fully coupled one. The partial coupling approach is applied to decompose the fully coupled climate response to CO 2 quadrupling into atmosphere- and ocean-driven components. The linearity of the decomposition is validated by simulating the ocean-driven response using another complimentary partially coupled simulation forced only with the atmosphere-driven anomalous surface fluxes. A comparison of the two partially coupled simulations with the fully coupled simulation indicates that the sum of the atmosphere- and ocean-driven components accurately describes the fully coupled response. The decomposition identifies several robust atmosphere- and ocean-driven features of the global warming and provides new insights into the impacts of atmospheric feedbacks on the Atlantic overturning circulation and sea ice response to CO 2 increase.

54 ENVIRONMENTAL SCIENCES↗

Degradation Mechanism of Phosphate‐Based Li‐NASICON Conductors in Alkaline Environment

NASICON-type Li conductors (Li-NASICON) have traditionally been regarded as promising candidates for solid-state Li-air battery applications because of their stability in water and ambient air. However, the presence of water in the cathode of a Li-air battery can induce a highly alkaline environment by modifying the discharge product from Li 2 O 2 to LiOH which can potentially degrade cathode and separator materials. This study investigates the alkaline stability of common Li-NASICON chemistries through a systematic experimental study of LiTi x Ge 2-x (PO 4 ) 3 (LTGP) with varying x = 0–2.0. Density functional theory calculations are combined to gain a mechanistic understanding of the alkaline instability. It is demonstrated that the instability of LTGP in an alkaline environment is mainly driven by the dissolution of PO 4 3– groups, which subsequently precipitate as Li 3 PO 4 . The introduction of Ti facilitates the formation of a Ti-rich compound on the surface that eventually passivates the material, but only after significant bulk degradation. Consequently, phosphate-based Li-NASICON materials exhibit limited alkaline stability, raising concerns about their viability in humid Li-air batteries.

25 ENERGY STORAGE↗

Numerical investigation of mass flow rate effects on multiplicity of detonation waves within a H 2 /Air rotating detonation combustor

This paper presents results from numerical simulations of a non-premixed hydrogen-air rotating detonation combustor with radial injection. The fuel and air mass flow rate are varied in order to hold a unity global equivalence ratio. The calculations show that multiple detonation waves co-exist when the mass flow rate is increased. Conditional statistics of the detonation structure and combustion processes suggest similarities across co-existing waves. Quantification of the injection response to the rotation of a detonation indicates that at higher flow rate the refill time is short enough to allow for a quick and well mixed composition prior to the new front passage. Details of the combustion characteristics are analyzed. Finally, the results elucidate the correlation between initial injection conditions and detonation multiplicity on the overall physics within the combustor.

08 HYDROGEN↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity and vulnerability to summer heat extremes in major cities of the United States

Many cities are experiencing increases in extreme heat because of global temperature rise combined with the urban heat island effect. The heterogeneity of urban morphology also leads to fine-scale variability in potential for heat exposure. Yet, how this rise in temperature and local variability together impacts urban residents differently at exposure-relevant scales is still not clear. Here we map the Universal Thermal Climate Index, a more complete indicator of human heat stress at an unprecedentedly fine spatial resolution (1 m), for 14 major cities in the United States using urban microclimate modeling. We examined the different heat exposure levels across different socioeconomic and racial/ethnic groups in these cities, finding that income level is most consistently associated with heat stress. We further conducted scenario simulations for a hypothetical 1 °C increase of air temperature in all cities. Results show that a 1 °C increase would have a substantial impact on human heat stress, with impacts that differ across cities. The results of this study can help us better evaluate the impact of extreme heat on urban residents at decision-relevant scales.

54 ENVIRONMENTAL SCIENCES↗

Thermal Design Consideration of Medium Voltage High Frequency Transformers

This paper describes a thermal design using epoxy potting for high frequency transformer (HFT) for medium voltage high power electronic applications, namely emerging solid-state transformers. To address HFT’s thermal stress problem, thermal performance of the HFT with air and epoxy potting cooling method are both simulated by magnetothermal-fluid coupling method (MTFCM). The effectiveness of the simulation analysis is verified in a 100 kW DC-DC resonant converter. Influencing factors including distance between the high frequency transformer and the metal enclosure, epoxy thermal conductivity and heat sink placements are simulated and analyzed. Finally, an optimal cooling structure is proposed for future high power HFTs.

Wang, Haoming↗

Investigating the Combustion Performance of Dual Fuel Combustion with Diesel and Port Injected Hydrogen in a Large Bore Locomotive Engine

The heavy-duty transportation sector has primarily relied on conventional diesel combustion engines given their reliability and high thermal efficiency relative to spark ignition engines, but increased focus on reducing greenhouse gas emissions has led to investigation into alternative fuels. Gaseous hydrogen fuel has garnered a great deal of recent interest in the engine community given it has zero carbon, but hydrogen is not available at the scale and cost that petroleum fuels are currently available, and this is a barrier to adoption for industries that are looking to decarbonize their operations. Because of the fuel flexibility provided, dual fuel technology offers a pathway for some industries to adopt hydrogen as a fuel source while maintaining sufficient flexibility in times and locations where the new fuel is not yet available. This computational study investigates dual fuel combustion in a large bore locomotive engine architecture using direct injected diesel and port injected gaseous hydrogen fuel. With an optimal port fuel injection configuration from previous work, simulations of varying substitution ratio, compression ratio, manifold air temperature, diesel injection timing, and diesel injection pressure were performed to understand their effect on combustion performance. Results indicated that both increased substitution ratio and higher intake air temperature accelerates hydrogen flame propagation and can result in high peak cylinder pressures. Additionally, diesel injection timing and injection pressure were demonstrated as effective methods for controlling dual fuel combustion heat release rates.

ODonnell, Patrick Christopher↗

UrbanScaping: Community Spatial Data Visualization & Analytics

Evaluating the electrification potential of buildings through retrofitting is crucial for reducing carbon emissions and the carbon footprint of built environments. This study leverages the Automatic Building Energy Modeling (AutoBEM) software, integrating the Model America database to create an urban context-based spatial analysis platform for community engagement and development. We selected Camp Hill Borough, PA, as a case study to analyze building-specific energy performance and evaluate the electrification potential of each building by switching to different Heating, Ventilation, and Air Conditioning (HVAC) systems and measurement components. The simulation results generated by the workflow provide retrofitting suggestions to help mitigate the carbon footprint as well as energy saving statistics of buildings. Additionally, the developed web-based interface serves as a community engagement platform, allowing residents to provide feedback and further develop interactive communication protocols. The outcomes of this project offer a baseline for community electrification planning and contribute to the design of low-carbon communities.

Chowdhury, Shovan [ORNL]↗

Community Geothermal: Borefield Design, Thermal Conductivity, and Subsurface Modeling Data - Chicago, IL

This dataset encompasses the development of a geothermal energy system for the West Woodlawn neighborhood in Chicago, Illinois. This project is part of a broader initiative to design and deploy geothermal heating and cooling systems at a community scale. The dataset includes thermal conductivity test results, calculations for borehole sizing based on the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) method, as well as simulated thermal loads based on actual energy usage from individual buildings. Also provided here are files used for numerical modeling via COMSOL Multiphysics to simulate borefield design and subsurface thermal behavior. Two manuscripts are attached, which outline the broad objectives of the project and a description of the numerical modeling methodology and results.

15 GEOTHERMAL ENERGY↗

Privacy-Preserving Transactive Energy System

In this paper, the privacy issue of recently proposed transactive energy systems for electric power systems is studied for the first time. It is identified that the private information of individual market participants is subject to the risk of leakage during their market-based interaction. In order to protect their privacy, a homomorphic encryption-based approach is developed to achieve the privacy preservation with the Paillier encryption scheme. The proposed privacy-perserving design is then demonstrated on a transactive energy system that coordinates and controls residential air conditioners to manage the feeder congestion. The simulation results confirm the effectiveness of the proposed design in protecting the privacy of individual market participants without affecting the overall system performance. Future work on the proposed design is also suggested.

Lu, Yang↗

Development of aerosol activation in the double-moment Unified Model and evaluation with CLARIFY measurements

Representing the number and mass of cloud and aerosol particles independently in a climate, weather prediction or air quality model is important in order to simulate aerosol direct and indirect effects on radiation balance. Here we introduce the first configuration of the UK Met Office Unified Model in which both cloud and aerosol particles have “double-moment” representations with prognostic number and mass. The GLObal Model of Aerosol Processes (GLOMAP) aerosol microphysics scheme, already used in the Hadley Centre Global Environmental Model version 3 (HadGEM3) climate configuration, is coupled to the Cloud AeroSol Interacting Microphysics (CASIM) cloud microphysics scheme. We demonstrate the performance of the new configuration in high-resolution simulations of a case study defined from the CLARIFY aircraft campaign in 2017 near Ascension Island in the tropical southern Atlantic. We improve the physical basis of the activation scheme by representing the effect of existing cloud droplets on the activation of new aerosol, and we also discuss the effect of unresolved vertical velocities. We show that neglect of these two competing effects in previous studies led to compensating errors but realistic droplet concentrations. While these changes lead only to a modest improvement in model performance, they reinforce our confidence in the ability of the model microphysics code to simulate the aerosol–cloud microphysical interactions it was designed to represent. Capturing these interactions accurately is critical to simulating aerosol effects on climate.

54 ENVIRONMENTAL SCIENCES↗

Quantifying wildfire drivers and predictability in boreal peatlands using a two-step error-correcting machine learning framework in TeFire v1.0

Abstract. Wildfires are becoming an increasing challenge to the sustainability of boreal peatland (BP) ecosystems and can alter the stability of boreal carbon storage. However, predicting the occurrence of rare and extreme BP fires proves to be challenging, and gaining a quantitative understanding of the factors, both natural and anthropogenic, inducing BP fires remains elusive. Here, we quantified the predictability of BP fires and their primary controlling factors from 1997 to 2015 using a two-step correcting machine learning (ML) framework that combines multiple ML classifiers, regression models, and an error-correcting technique. We found that (1) the adopted oversampling algorithm effectively addressed the unbalanced data and improved the recall rate by 26.88 %–48.62 % when using multiple datasets, and the error-correcting technique tackled the overestimation of fire sizes during fire seasons; (2) nonparametric models outperformed parametric models in predicting fire occurrences, and the random forest machine learning model performed the best, with the area under the receiver operating characteristic curve ranging from 0.83 to 0.93 across multiple fire datasets; and (3) four sets of factor-control simulations consistently indicated the dominant role of temperature, air dryness, and climate extreme (i.e., frost) for boreal peatland fires, overriding the effects of precipitation, wind speed, and human activities. Our findings demonstrate the efficiency and accuracy of ML techniques in predicting rare and extreme fire events and disentangle the primary factors determining BP fires, which are critical for predicting future fire risks under climate change.

54 ENVIRONMENTAL SCIENCES↗

Feature Analysis, Tracking, and Data Reduction: An Application to Multiphase Reactor Simulation MFiX-Exa for In-Situ Use Case

As we enter the exascale computing regime, powerful supercomputers continue to produce much higher amounts of data than what can be stored for offline data processing. To utilize such high compute capabilities on these machines, much of the data processing needs to happen in situ, when the full high-resolution data is available at the supercomputer memory. In this article, we discuss our MFiX-Exa simulation, which models multiphase flow by tracking a very large number of particles through the simulation domain. In one of the use cases, the carbon particles interact with air to produce carbon dioxide bubbles from the reactor. These bubbles are of primary interest to the domain experts for these simulations. For this particle-based simulation, we propose a streaming technique that can be deployed in situ to efficiently identify the bubbles, track them over time, and use them to down-sample the data with minimal loss in these features.

97 MATHEMATICS AND COMPUTING↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface‐Atmosphere Decoupling Prolongs Cloud Lifetime Under Warm Advection Due To Reduced Entrainment Drying

Abstract An initially well‐mixed stratocumulus deck can remain overcast for several tens of hours under warm‐advection conditions, although moisture supply is cut off from the ocean due to surface‐atmosphere decoupling (stabilization of the surface‐atmosphere interface). In this study, a set of idealized large‐eddy simulations were performed to investigate the physical mechanism of how warm‐air advection impacts the evolution of a pre‐existing stratocumulus deck. To mimic warm‐air advection, we decrease the sea surface temperature linearly over time in a doubly periodic domain. Given the same initial conditions, the stratocumulus deck is more persistent when experiencing warm‐air advection than cold‐air advection. This persistence is caused by reduced cloud‐top entrainment drying due to decoupling, a process more influential than the decoupling‐induced cutoff of moisture supply. This mechanism is more notable when the free troposphere becomes more humid. The relevance of the mechanism to previous observations of less low‐level cloudiness under warm‐advection conditions is discussed.

54 ENVIRONMENTAL SCIENCES↗