Reducing/Eliminating ESD Hazards During Pyro Operations
Several safety concerns have occurred during pyro operations at 30% or lower RH in the OPF area based on the increase of electrostatic discharge (ESD). These concerns targeted the safety of personnel, flight hardware, and ground support equipment (GSE). Two proposed methods considered to control ESDs during pyro operations at 30% or lower RH are the use of an ionizer blower and to increase the moisture content. In order to demonstrate that the ionizer is effective in neutralizing static charge, a series of experimental runs were conducted in the Electrostatics Laboratory located in the Operations & Checkout (O&C) Building at NASA Kennedy Space Center (KSC). The effectiveness of the ionizer blower was evaluated based upon the time lapse of a charged metal plate from initial 1000 to 400 volts. Distance, RH, and angle of attack were studied. A full factorial experiment (2(exp 3) = 8) was conducted. Since we did not have a statistical analysis program, such as SAS, available, calculations were done manually based on the method of ANOVA (Analysis of Variances), but R(exp 2) (fitness of curve) was not obtained. As conjectured, distance was found to be the major influencial variable. Therefore, we concluded that the best possible combination of situations would be to position the ionizer blower as close as possible and facing directly into the charged plate. This scenario resulted in the quickest discharge rate, which would be the most beneficial during pyro operations below 30% RH. The second method of increasing the moisture content in the work environment through a modification of the OPF ECS current configuration appeared to be dependent on budget constraints and currently not planned to be modified. Finally, some recommendations are discussed such as to test the ionizer in an actual field experiment with a mockup pyro connector and a technician with all the NASA KSC Safety-compliant PPE to assess the realistic effectiveness of the ionizer blower.