Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Redox Mediated Control of Electrochemical Potential in Liquid Cell Electron Microscopy

Liquid cell electron microscopy enables the study of nanoscale transformations in solvents with high spatial and temporal resolution, but for the technique to achieve its potential requires a new level of control over the reactivity caused by radical generation under electron beam irradiation. An understanding of how to control electron-solvent interactions is needed to further advance the study of structural dynamics for complex materials at the nanoscale. Additionally, we developed an approach that scavenges radicals with redox species that form well-defined redox couples and control the electrochemical potential in situ . This approach enables the observation of electrochemical structural dynamics at near-atomic resolution with precise control of the liquid environment. Analysis of nanocrystal etching trajectories indicates that this approach can be generalized to several chemical systems. The ability to simultaneously observe heterogeneous reactions at near-atomic resolution and precisely control the electrochemical potential enables the fundamental study of complex nanoscale dynamics with unprecedented detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atom-resolved imaging with a silicon tip integrated into an on-chip scanning tunneling microscope

Limited throughput is a shortcoming of the Scanning Tunneling Microscope (STM), particularly when used for atomically precise lithography. To address this issue, we have developed an on-chip STM based on Microelectromechanical-Systems (MEMS) technology. The device reported here has one degree of freedom, replacing the Z axis in a conventional STM. The small footprint of the on-chip STM provides a great opportunity to increase STM throughput by incorporating a number of on-chip STMs in an array to realize parallel STM. The tip methodology adopted for the on-chip STM presented here, which is a batch-fabricated Si tip, makes our design conducive to this goal. In this work, we investigate the capability of this on-chip STM with an integrated Si tip for STM imaging. We integrate the on-chip STM into a commercial ultrahigh-vacuum STM system and perform imaging with atomic resolution on par with conventional STMs but at higher scan speeds due to the higher sensitivity of the MEMS actuator relative to a piezotube. The results attest that it is possible to achieve a parallel and high-throughput STM platform, which is a fully batch-fabricated MEMS STM nanopositioner capable of performing atomic-resolution STM imaging.

Instruments & Instrumentation↗

Acoustic emission and magnification of atomic lines resolution for laser breakdown of salt water in ultrasound field

Researches of the acoustic effects accompanying optical breakdown in a water, generated by the focused laser radiation with power ultrasound have been carried out. Experiments were performed by using 532 nm pulses from Brilliant B Nd:YAG laser. Acoustic radiation was produced by acoustic focusing systems in the form hemisphere and ring by various resonance frequencies of 10.7 kHz and 60 kHz. The experimental results are obtained, that show the sharply strengthens effects of acoustic emission from a breakdown zone by the joint influence of a laser and ultrasonic irradiation. Essentially various thresholds of breakdown and character of acoustic emission in fresh and sea water are found out. The experimental result is established, testifying that acoustic emission of optical breakdown of sea water at presence and at absence of ultrasound essentially exceeds acoustic emission in fresh water. Atomic lines of some chemical elements like a Sodium, Magnesium and so on were investigated for laser breakdown of water with ultrasound field. The effect of magnification of this lines resolution for salt water in ultrasound field was obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Temperature Superconductivity in a Single Copper-Oxygen Plane

The question of how thin cuprate layers can be while still retaining high-temperature superconductivity (HTS) has been challenging to address, in part because experimental studies require the synthesis of near-perfect ultrathin HTS layers and ways to profile the superconducting properties such as the critical temperature and the superfluid density across interfaces with atomic resolution. We used atomic-layer molecular beam epitaxy to synthesize bilayers of a cuprate metal (La{sub 1.65}Sr{sub 0.45}CuO{sub 4}) and a cuprate insulator (La{sub 2}CuO{sub 4}) in which each layer is just three unit cells thick. We selectively doped layers with isovalent Zn atoms, which suppress superconductivity and act as markers, to show that this interface HTS occurs within a single CuO{sub 2} plane. This approach may also be useful in fabricating HTS devices.

36 MATERIALS SCIENCE↗

Dynamic scan control in STEM: spiral scans

Abstract Scanning transmission electron microscopy (STEM) has emerged as one of the foremost techniques to analyze materials at atomic resolution. However, two practical difficulties inherent to STEM imaging are: radiation damage imparted by the electron beam, which can potentially damage or otherwise modify the specimen and slow-scan image acquisition, which limits the ability to capture dynamic changes at high temporal resolution. Furthermore, due in part to scan flyback corrections, typical raster scan methods result in an uneven distribution of dose across the scanned area. A method to allow extremely fast scanning with a uniform residence time would enable imaging at low electron doses, ameliorating radiation damage and at the same time permitting image acquisition at higher frame-rates while maintaining atomic resolution. The practical complication is that rastering the STEM probe at higher speeds causes significant image distortions. Non-square scan patterns provide a solution to this dilemma and can be tailored for low dose imaging conditions. Here, we develop a method for imaging with alternative scan patterns and investigate their performance at very high scan speeds. A general analysis for spiral scanning is presented here for the following spiral scan functions: Archimedean, Fermat, and constant linear velocity spirals, which were tested for STEM imaging. The quality of spiral scan STEM images is generally comparable with STEM images from conventional raster scans, and the dose uniformity can be improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-scale Mechanisms of Enhanced Electrochemical Properties of Mo-doped Co-free Layered Oxide Cathodes for Lithium-Ion Batteries

Cobalt-free layered oxides with high specific capacity and low cost have emerged as promising candidates for next-generation cathodes for lithium-ion batteries. However, implementation of these materials has been hindered by their low rate capability, structural instability, and rapid capacity decay during cycling. Recent studies have shown that introducing cation dopants into layered oxides can strongly improve their electrochemical properties, but the underlying mechanisms remain elusive due to a lack of information at the atomic scale. In this work, we use a combination of atomic-resolution scanning transmission electron microscopy and first principle calculations to reveal the microscopic origin of enhanced electrochemical properties in LiNi0.5Mn0.5O2 doped with ~1 at % Mo. These results indicate that the Mo dopant hinders Li+/Ni2+ cation mixing and suppresses detrimental phase transformations near the particle surface and at grain boundaries, which enhances the cathode’s reversible capacity and cycling stability. Overall, This work provides important insights on how cation doping affects the structure and electrochemical properties of layered oxide cathodes.

Li, Linze↗

Ingrained: An Automated Framework for Fusing Atomic-Scale Image Simulations into Experiments

To fully leverage the power of image simulation to corroborate and explain patterns and structures in atomic resolution microscopy, an initial correspondence between the simulation and experimental image must be established at the outset of further high accuracy simulations or calculations. Furthermore, if simulation is to be used in context of highly automated processes or high-throughput optimization, the process of finding this correspondence itself must be automated. In this work, "ingrained," an open-source automation framework which solves for this correspondence and fuses atomic resolution image simulations into the experimental images to which they correspond, is introduced. Here, the overall "ingrained" workflow, focusing on its application to interface structure approximations, and the development of an experimentally rationalized forward model for scanning tunneling microscopy simulation are described.

36 MATERIALS SCIENCE↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

From ground to excited electronic state dynamics of electron and ion irradiated graphene nanomaterials

Microscopes utilizing convergent electron and ion beams are emerging as powerful tools for both imaging and manipulating two-dimensional materials with atomic resolution, allowing the ultimate limits of nanofabrication to be realized. In this chapter, we detail the use of time-dependent electronic structure theory to determine the excited state properties and reactivity of functionalized graphene nanostructures. A time-dependent density functional theory treatment of electronic excitations of materials is presented, with specific emphasis on predicting the position-dependent electronic response of two-dimensional nanomaterials to electron beams. The method is demonstrated in a study highlighting the important role that electronic excitation can play in opening reaction pathways relevant to atomically precise defect manipulation in graphene. Finally, we provide some perspective on future development directions for methods of simulating nonequilibrium electronic and vibrational dynamics induced by electron/ion beams.

Lingerfelt, David↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗

Quantifying the dislocation content of atomically resolved grain boundary line defects using the Nye tensor

The Nye tensor, which quantifies the density of Burgers vector for a given dislocation line direction, can be effectively used to characterize dislocation content in bulk crystals from atomic-resolution transmission electron microscopy images. The Nye tensor can be calculated from these images, in part because the reference state is simply defined by the lattice of the perfect crystal. The application of the Nye tensor to interfacial line defects, for which the natural reference state is the dichromatic pattern of the two grains in their reference orientation, poses additional challenges. In this work, we present a method that employs the Nye tensor to characterize the edge dislocation content of line defects at grain boundaries from atomic-resolution images. This approach enables us to rapidly characterize all edge dislocation content along a grain boundary. Additionally, the Nye tensor provides information about line defect core structure. Finally, we demonstrate this method on two exemplar defects: a twin boundary disconnection and a facet junction in face-centered cubic Au.

Crystallographic defects↗

The N‐terminal intrinsically disordered region of Ncb5or docks with the cytochrome b 5 core to form a helical motif that is of ancient origin

Abstract NADH cytochromeb 5 oxidoreductase (Ncb5or) is a cytosolic ferric reductase implicated in diabetes and neurological conditions. Ncb5or comprises cytochromeb 5 (b 5 ) and cytochromeb 5 reductase (b 5 R) domains separated by a CHORD‐Sgt1 (CS) linker domain. Ncb5or redox activity depends on proper inter‐domain interactions to mediate electron transfer from NADH or NADPH via FAD to heme. While full‐length human Ncb5or has proven resistant to crystallization, we have succeeded in obtaining high‐resolution atomic structures of theb 5 domain and a construct containing the CS andb 5 R domains (CS/b 5 R). Ncb5or also contains an N‐terminal intrinsically disordered region of 50 residues that has no homologs in other protein families in animals but features a distinctive, conserved L 34 MDWIRL 40 motif also present in reduced lateral root formation (RLF) protein in rice and increased recombination center 21 in baker's yeast, all attaching to ab 5 domain. After unsuccessful attempts at crystallizing a human Ncb5or construct comprising the N‐terminal region naturally fused to theb 5 domain, we were able to obtain a high‐resolution atomic structure of a recombinant rice RLF construct corresponding to residues 25–129 of human Ncb5or (52% sequence identity; 74% similarity). The structure reveals Trp 120 (corresponding to invariant Trp 37 in Ncb5or) to be part of an 11‐residue α‐helix (S 116 QMDWLKLTRT 126 ) packing against two of the four helices in theb 5 domain that surround heme (α2 and α5). The Trp 120 side chain forms a network of interactions with the side chains of four highly conserved residues corresponding to Tyr 85 and Tyr 88 (α2), Cys 124 (α5), and Leu 47 in Ncb5or. Circular dichroism measurements of human Ncb5or fragments further support a key role of Trp 37 in nucleating the formation of the N‐terminal helix, whose location in the N/b 5 module suggests a role in regulating the function of this multi‐domain redox enzyme. This study revealed for the first time an ancient origin of a helical motif in the N/b 5 module as reflected by its existence in a class of cytochromeb 5 proteins from three kingdoms among eukaryotes.

Biochemistry & Molecular Biology↗

A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability

We present a novel homebuilt scanning tunneling microscope (STM) with high quality atomic resolution. It is equipped with a small but powerful GeckoDrive piezoelectric motor which drives a miniature and detachable scanning part to implement coarse approach. The scanning part is a tiny piezoelectric tube scanner (industry type: PZT-8, whose d{sub 31} coefficient is one of the lowest) housed in a slightly bigger polished sapphire tube, which is riding on and spring clamped against the knife edges of a tungsten slot. The STM so constructed shows low back-lashing and drifting and high repeatability and immunity to external vibrations. These are confirmed by its low imaging voltages, low distortions in the spiral scanned images, and high atomic resolution quality even when the STM is placed on the ground of the fifth floor without any external or internal vibration isolation devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission electron microscopy study of the MgS–Tm{sub 2}S{sub 3} system

This work presents the structural–microstructural characterization of the NaCl-derivative MgS–Tm{sub 2}S{sub 3} system, which can be formulated by the expression Mg{sub (1−x)}Tm{sub (2/3)x}□{sub (1/3)x}S (□→cation vacancy). Transmission electron microscopy observations show the transition between NaCl-type and spinel-type structures when 0 ≤x≤ 0.75. The increase of Tm content in the solid solution provokes the increase of the spinel-type phase proportion, which intergrows with the NaCl-type crystals. When x≥0.75, some phases derived from NaCl-type structure through the chemical twinning at the unit cell level crystallographic operation are observed, such as CT-MgTm{sub 2}S{sub 4} and CT-MgTm{sub 4}S{sub 7}. The existence and nature of the extended defects observed along the c direction of these structures are characterized by means of Scanning-Transmission electron microscopy high-angle dark field imaging, which allows observing the presence of quasi ordered crystals with new possible complex stoichiometries at atomic resolution. - Graphical abstract: HAADF-STEM image of a disordered CT-MgYb{sub 2}S{sub 4} crystal. The disordered twin-slab sequences are marked by arrows. - Highlights: • Structural evolution of the Mg{sub (1−x)}Tm{sub (2/3)x}□{sub (1/3)x}S system was characterized by means of TEM. • The increase in Tm content provokes the transition from NaCl to spinel-type structure up to x=0.75. • Chemical twinned phases CT-MgTm{sub 2}S{sub 4} and CT-MgTm{sub 4}S{sub 7} are observed at high Tm contents. • Extended defects in CT-crystals are characterized with atomic resolution STEM-HAADF images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A hydrogen-bonding network is important for oxidation and isomerization in the reaction catalyzed by cholesterol oxidase

The importance of active-site electrostatics for oxidative and reductive half-reactions in a redox flavoenzyme (cholesterol oxidase) have been investigated by a combination of biochemistry and atomic resolution crystallography. A detailed examination of active-site dynamics demonstrates that the oxidation of substrate and the re-oxidation of the flavin cofactor by molecular oxygen are linked by a single active-site asparagine. Cholesterol oxidase is a flavoenzyme that catalyzes the oxidation and isomerization of 3β-hydroxysteroids. Structural and mutagenesis studies have shown that Asn485 plays a key role in substrate oxidation. The side chain makes an NH⋯π interaction with the reduced form of the flavin cofactor. A N485D mutant was constructed to further test the role of the amide group in catalysis. The mutation resulted in a 1800-fold drop in the overall k{sub cat}. Atomic resolution structures were determined for both the N485L and N485D mutants. The structure of the N485D mutant enzyme (at 1.0 Å resolution) reveals significant perturbations in the active site. As predicted, Asp485 is oriented away from the flavin moiety, such that any stabilizing interaction with the reduced flavin is abolished. Met122 and Glu361 form unusual hydrogen bonds to the functional group of Asp485 and are displaced from the positions they occupy in the wild-type active site. The overall effect is to disrupt the stabilization of the reduced FAD cofactor during catalysis. Furthermore, a narrow transient channel that is shown to form when the wild-type Asn485 forms the NH⋯π interaction with FAD and that has been proposed to function as an access route of molecular oxygen, is not observed in either of the mutant structures, suggesting that the dynamics of the active site are altered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗