Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Investigation of resistive magnetic field generation by intense proton beams in dense plasmas

Current and future applications of intense proton sources abound, including radiography, cancer therapy, warm dense matter generation, and inertial confinement fusion. With increasingly efficient acceleration and focusing mechanisms, proton current densities may soon approach and exceed 10 10 A/cm 2 , e.g., via intense laser drivers. Simulations have previously shown that in this current density regime, beam-induced field generation plays a significant role in beam transport through dense plasmas. Here, we present a theoretical model for the generation of resistive magnetic fields by intense proton beam transport through solid density plasmas. The theoretical evolution of the magnetic field profile is calculated using an analytic model for aluminum resistivity, heat capacity, and stopping power, applicable from cold matter to hot plasma. The effects of various beam and material parameters on the field are investigated and explained for both monoenergetic and Maxwellian proton beams. For a proton beam with Maxwellian temperature 5 MeV and total energy 10 J, the model calculates resistive magnetic fields up to 150 T in aluminum. In conclusion, the calculated field profiles from several beam cases are compared with 2D hybrid particle-in-cell simulations, with good agreement found in magnitude and time scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Measurement Results of the LCLS Undulator Quadrupoles

This note details the magnetic measurements and the magnetic center fiducializations that were performed on all of the thirty-six LCLS undulator quadrupoles. Temperature rise, standardization reproducibility, vacuum chamber effects and magnetic center reproducibility measurements are also presented. The Linac Coherent Light Source (LCLS) undulator beam line has 33 girders, each with a LCLS undulator quadrupole which focuses and steers the beam through the beam line. Each quadrupole has main quadrupole coils, as well as separate horizontal and vertical trim coils. Thirty-six quadrupoles, thirty-three installed and three spares were, manufactured for the LCLS undulator system and all were measured to confirm that they met requirement specifications for integrated gradient, harmonics and for magnetic center shifts after current changes. The horizontal and vertical dipole trims of each quadrupole were similarly characterized. Each quadrupole was also fiducialized to its magnetic center. All characterizing measurements on the undulator quads were performed with their mirror plates on and after a standardization of three cycles from -6 to +6 to -6 amps. Since the undulator quadrupoles could be used as a focusing or defocusing magnet depending on their location, all quadrupoles were characterized as focusing and as defocusing quadrupoles. A subset of the undulator quadrupoles were used to verify that the undulator quadrupole design met specifications for temperature rise, standardization reproducibility and magnetic center reproducibility after splitting. The effects of the mirror plates on the undulator quadrupoles were also measured.

43 PARTICLE ACCELERATORS↗

Approaching isotropy in the vortex system of SmFeAs(O,F) at extreme magnetic fields

The role of anisotropy in the iron-pnictides is one of the key questions in understanding their high-temperature superconductivity. The inherent layeredness of these systems, consisting of FeAs layers separated by various layers, gives rise to an upper critical field anisotropy γ(T c ) ~ 3 in the “122” system (i.e. (Ba,K)Fe 2 As 2 ) and up to 6-8 in the “1111” system (i.e. SmFeAs(O,F)). In the “122” compounds, this anisotropy is known to decrease upon cooling, converging to almost isotropic superconductivity at lowest temperatures[1]. This can be understood through a particular temperature dependence of the inter- and intra-band scattering. The “1111” class is naturally more anisotropic due to the thicker SmO blocking layer, and the much higher upper critical fields (H c2 , HIIab(0)>>100T) cannot be reached at low temperature. Despite this challenging field requirement, the aim of this project is to discern whether this emergent isotropy in the “122” materials is a property of all FeAs classes. Focused Ion Beam (FIB) micromachined samples have in the past proven to be particularly well suited for pulsed magnetic fields[2]. Employing the micrometer precision of the FIB, we fabricated three individual samples on a 2x2 mm chip and thus maximized the acquired transport data per pulse.

36 MATERIALS SCIENCE↗

A Review of Advanced Characterization Methods and Techniques for Amorphous and Poorly Crystalline Materials Applicable to Cementitious Waste Forms

This review covers advanced characterization methods of cementitious materials. The particular focus is to understand cementitious compositions with amorphous content because conventional techniques such as X-ray diffraction are more applicable to materials with long range order. Also of interest is advanced characterization that provides deeper insights into properties such as porosity. There are five groups of characterization methods discussed in this review which are: electron beam/microscopy, X-ray, neutron diffraction and scattering, nuclear magnetic resonance, and optical techniques. The techniques can be further grouped by the categories of nanoscale structural understanding (transmission electron microscopy and pair distribution function), microscale structural understanding (focused ion beam and x-ray tomography), microscopic elemental distributions (energy dispersive spectroscopy and X-ray fluorescence), and chemical binding information (electron energy loss spectroscopy, x-ray absorption spectroscopy, nuclear magnetic resonance, Raman spectroscopy, and infrared spectroscopy), with advantages and disadvantages of each method discussed. The recommendation for further research is to begin with techniques that are easier to prepare samples for, measure, and analyze, such as the optical techniques of Raman and infrared spectroscopy. If more information is needed, pursue collaborations, other techniques, or proposals for beam time at the synchrotron sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Nonlinear Dynamics of Intense Charged Particle Beams in the Paul Trap Simulator Experiment

The Paul Trap Simulator Experiment (PTSX) is a compact laboratory device that simulates the nonlinear dynamics of intense charged particle beams propagating over a large distance in an alternating-gradient magnetic transport system. The radial quadrupole electric eld forces on the charged particles in the Paul Trap are analogous to the radial forces on the charged particles in the quadrupole magnetic transport system. The amplitude of oscillating voltage applied to the cylindrical electrodes in PTSX is equivalent to the quadrupole magnetic eld gradient in accelerators. The temporal periodicity in PTSX corresponds to the spatial periodicity in magnetic transport system. This thesis focuses on investigations of envelope instabilities and collective mode excitations, properties of high-intensity beams with significant space-charge effects, random noise-induced beam degradation and a laser-induced-fluorescence diagnostic. To better understand the nonlinear dynamics of the charged particle beams, it is critical to understand the collective processes of the charged particles. Charged particle beams support a variety of collective modes, among which the quadrupole mode and the dipole mode are of the greatest interest. We used quadrupole and dipole perturbations to excite the quadrupole and dipole mode respectively and study the effects of those collective modes on the charge bunch. The experimental and particle-in-cell (PIC) simulation results both show that when the frequency and the spatial structure of the external perturbation are matched with the corresponding collective mode, that mode will be excited to a large amplitude and resonates strongly with the external perturbation, usually causing expansion of the charge bunch and loss of particles. Machine imperfections are inevitable for accelerator systems, and we use random noise to simulate the effects of machine imperfection on the charged particle beams. The random noise can be Fourier decomposed into various frequency components and experimental results show that when the random noise has a large frequency component that matches a certain collective mode, the mode will also be excited and cause heating of the charge bunch. It is also noted that by rearranging the order of the random noise, the adverse effects of the random noise may be eliminated. As a non-destructive diagnostic method, a laser-induced- fluorescence (LIF) diagnostic is developed to study the transverse dynamics of the charged particle beams. The accompanying barium ion source and dye laser system are developed and tested.

LIF↗

Modulating Oxide‐Based Quantum Materials by Ion Implantation

Ion implantation has emerged as a powerful tool for manipulating and investigating oxide quantum materials, where strong electron correlations give rise to exotic phases and functionalities. This Review examines how controlled ion bombardment enables targeted modulation of structural, electronic, and magnetic properties in complex oxides. Recent advances in ion beam techniques is analyzed that provide unprecedented control over defect profiles, from point defects to extended damage cascades. In application, ion irradiation has demonstrated the ability to tune quantum phenomena including metal‐insulator transitions, magnetism, and superconductivity through selective doping, defect creation, and lattice strain. The ability to write quantum states with nanoscale precision using focused ion beams is opening new paths for quantum device fabrication. Challenges in understanding radiation damage mechanisms in strongly correlated systems is discussed, and identify opportunities for designing quantum functionality through defect‐engineering approaches. The technique's demonstrated capability to write quantum states with nanoscale precision, combined with its compatibility with existing semiconductor processing infrastructure, suggests a clear pathway for translating fundamental discoveries in quantum materials into practical technological applications.

defect engineering↗

Initial experimental evidence of self-collimation of target-normal-sheath-accelerated proton beam in a stack of conducting foils

Phenomena consistent with self-collimation (or weak self-focusing) of laser target-normal-sheath-accelerated protons was experimentally observed for the first time, in a specially engineered structure (“lens”) consisting of a stack of 300 thin aluminum foils separated by 50 μm vacuum gaps. The experiments were carried out in a “passive environment,” i.e., no external fields applied, neutralization plasma or injection of secondary charged particles was imposed. Experiments were performed at the petawatt “PHELIX” laser user facility (E = 100 J, Δt = 400 fs, λ = 1062 nm) at the “Helmholtzzentrum für Schwerionenforschung–GSI” in Darmstadt, Germany. The observed rms beam spot reduction depends inversely on energy, with a focusing degree decreasing monotonically from 2 at 5.4 MeV to 1.5 at 18.7 MeV. The physics inside the lens is complex, resulting in a number of different mechanisms that can potentially affect the particle dynamics within the structure. We present a plausible simple interpretation of the experiment in which the combination of magnetic self-pinch forces generated by the beam current together with the simultaneous reduction of the repulsive electrostatic forces due to the foils are the dominant mechanisms responsible for the observed focusing/collimation. This focusing technique could be applied to a wide variety of space-charge dominated proton and heavy ion beams and impact fields and applications, such as HEDP science, inertial confinement fusion in both fast ignition and heavy ion fusion approaches, compact laser-driven injectors for a Linear Accelerator (LINAC) or synchrotron, medical therapy, materials processing, etc.

43 PARTICLE ACCELERATORS↗

MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Specifications of the octupole magnets required for the ATF2 ultra-low ß* lattice

The Accelerator Test Facility 2 (ATF2) aims to test the novel chromaticity correction for higher chromaticity lattices as the one of CLIC. To this end the ATF2 ultra-low ß* lattice is designed to vertically focus the beam at the focal point or usually referred to as interaction point (IP), down to 23 nm. However when the measured multipole components of the ATF2 magnets are considered in the simulations, the evaluated spot sizes at the IP are well above the design value. The designed spot size is effectively recovered by inserting a pair of octupole magnets. In this note we address the technical specifications required for these octupole magnets.

43 PARTICLE ACCELERATORS↗

SU-E-T-745: The Use of Electron Dense Materials for Quality Assurance Testing in a Magnetic Field

Purpose: Due to the effect of the magnetic field on the dose deposition (skewing the beam), machine quality assurance (QA) tests for the MR-linac (MRI combined with a linear accelerator) need to be redesigned. In this work we focus on the redesign of QA tests that address geometrical accuracy of the system. Methods: Using electron dense materials (e.g. copper in our experiment) the dose kernel is minimized and thereby the effect of the magnetic field on the dose distribution. This approach is supported by Monte-Carlo simulations and can be used in practice with film measurements. Two examples of QA tests are presented: beam profile and star-shot measurements. Results: The novel method was verified by performing both measurements on a conventional linac and the MR-linac with a film that was sandwiched between copper layers. Measurements were compared with a reference setup which was similar to setup used in clinical practice. On a conventional linac the experimental outcome showed good agreement between the reference and the new setup for both QA tests. The results from the MR-linac showed that the symmetry of the beam profile was restored in presence of the copper layers in the setup and that the isocenter size can be determined accurately with the introduced star-shot setup (see supporting material). Conclusion: The use of electron dense materials for QA tests was shown to be a simple and effective method to remove the effects on the dose distribution enabling assessment of geometrical accuracy of a MR-linac system. The use of high dense materials is not limited to the presented QA tests only, but has a broad applicability for beam specific QA tests in presence of a magnetic field.

43 PARTICLE ACCELERATORS↗

Achromat Design for Multi-Pulse Test Line

This note describes the design of a 90° achromatic bend on DARHT Axis 2 to support multi-pulse target studies. The achromatic bend consists of two 45° dipole magnets with a focusing quadrupole centered between the dipoles. The optical design of the achromat is described followed by a discussion of the sensitivity to space charge and variations in the beam energy. The preliminary design of the magnets is then described with a description of the electro-mechanical parameters.

42 ENGINEERING↗

NUMI Flux Systematic Uncertainties

The Imaging Cosmic And Rare Underground Signals (ICARUS) detector is a 476 t active liquid argon time projection chamber neutrino detector at Fermilab. ICARUS lies 795 m downstream and 5.75◦ off-axis from the Neutrinos at the Main Injector (NuMI) beam. To create a neutrino beam NuMI directs pulsed beam of 120 GeV protons onto a graphite target to create hadrons, which are then focused by magnetic horns and allowed to decay into neutrinos. At the ICARUS off-axis angle the neutrino flux originates from the decays of unfocused/antifocused pions decays and from high-transverse momentum kaon decays. These contributions allow ICARUS to observe a significant flux of (anti-)electron and (anti-)muon neutrinos in a kinematic region relevant to the upcoming DUNE experiment. These factors also introduce various model uncertainties that have not been studied in detail by existing on-axis experiments. This poster will explore the systematic uncertainties in the NuMI flux at ICARUS that arise from uncertainties on hadron interaction cross sections and beamline operation conditions.

Alrahman, Fatima Abd [Houston U.]↗

A new method of out-of-focus millimeter wave imaging in fusion plasma diagnostics using Bessel beams

Electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry diagnostics have been employed on a number of magnetic fusion plasma confinement devices. The common approach is based on a Gaussian beam assumption, which generates good spatial resolution (centimeter level). However, the radial focal depth is limited by the poloidal resolution, which is comparable with the Rayleigh length (~150 mm). By contrast, a new Bessel beam approach has been developed and demonstrated to generate much longer focal depth with the property of propagation stability. To test the new approach, the DIII-D tokamak LCP ECEI optics have been re-designed to support a Bessel beam approach based on an axicon lens. The achievable radial coverage can exceed that of the current Gaussian approach by 3×. Finally, the imaging result is discussed in this paper based on the simulation analysis and laboratory testing result.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of 3D Code IBSimu for Designing an H{sup -}/D{sup -} Extraction System for the Texas A and M Facility Upgrade

A three dimensional ion optical code IBSimu is being developed at the University of Jyvaeskylae. So far the plasma modelling of the code has been restricted to positive ion extraction systems, but now a negative ion plasma extraction model has been added. The plasma model has been successfully validated with simulations of the Spallation Neutron Source (SNS) ion source extraction both in cylindrical symmetry and in full 3D, also modelling electron beam dumping and ion beam tilt. A filament-driven multicusp ion source has been installed at the Texas A and M University Cyclotron Institute for production of H{sup -} and D{sup -} beams as a part of the facility upgrade. The light ion beams, produced by the ion source, are accelerated with the K150 cyclotron for production and reacceleration of rare isotopes. The extraction system for the ion source was designed with IBSimu. The extraction features a water-cooled puller electrode with a permanent magnet dipole field for dumping the co-extracted electrons and a decelerating Einzel lens for adjusting the beam focusing for further beam transport. The ion source and the puller electrode are tilted at 4 degree angle with respect to the beam line. The extraction system can handle H{sup -} and D{sup -} beams with final beam energies from 5 keV to 15 keV using the same geometry, only adjusting the electrode voltages. So far, 24 {mu}A of H{sup -} and 15 {mu}A of D{sup -} have been extracted from the cyclotron.

43 PARTICLE ACCELERATORS↗

Septum Dump Quadrupole Measurements and Analysis

The purpose of the septum dump quadrupole (SDQ) magnet is to expand the beam size on the septum dump of the DARHT Axis 2 downstream transport. This is necessary in order to minimize the heating of the carbon beam dump and suppress desorption of ions. Initially, ions are generated through stimulated desorption and ionization of the monolayers of water vapor stuck to the beam dump surface. These ions propagate upstream at high speeds and act as an electrostatic focusing lens by reducing the beam space charge. As the beam size on the dump decreases, the dump is sufficiently heated so that a surface plasma is formed and much greater quantities of ions are generated through space charge limited emission. The interaction of these ions with the beam causes significant disruption of the beam. Because the SDQ focuses the beam in one plane and defocuses the beam in the orthogonal plane, it is critical that the beam in the focusing plane be over-focused so that the beam size in this plane is large on the beam stop. Thissets a minimum field at which the SDQ must operate. Recent magnetic measurements of the SDQ show that the actual field is about 15% lower than the design field. This note investigates the possible causes for this discrepancy and a path forward.

43 PARTICLE ACCELERATORS↗

Retuning the DARHT Axis-II Linear Induction Accelerator

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. The Axis-II 1.7-kA, 1600-ns beam pulse is transported through the LIA by the magnetic field from 91 solenoids as it is accelerated to ~16.5 MeV. The magnetic field produced by the solenoids and 80 steering dipole pairs for a given set of magnet currents is known as the “tune” of the accelerator [1]. From June, 2013 through September, 2014 a single tune was used. This tune was based on measurements of LIA element positions made over several years [2], and models of solenoidal fields derived from actual field measurements [3] [4]. Based on the focus scan technique, changing the tune of the accelerator and downstream transport had no effect on the beam emittance, to within the uncertainties of the measurement. Beam sizes appear to have been overestimated in all prior measurements because of the low magnification of the imaging system. This has resulted in overestimates of emittance by ~50%. The high magnification imaging should be repeated with the old tune for direct comparison with the new tune. High magnification imaging with the new accelerator tune should be repeated after retuning the downstream to produce a much more symmetric beam to reduce the uncertainty of this measurement. Thus, these results should be considered preliminary until we can effect a new tune to produce symmetric spots at our imaging station, for high magnification images.

43 PARTICLE ACCELERATORS↗