Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of high-order harmonic focusing system based on ellipsoidal mirror

We have developed a focusing system for extreme ultraviolet light produced by high-order harmonic generation. An ellipsoidal mirror with a precise surface shape was fabricated and installed into the focusing system. A rigid mirror manipulator and a beam profiler were employed to perform precise and stable mirror alignment. As a demonstration of the focusing performance, high-order harmonics in the wavelength range of 13.5–19.5 nm were successfully focused into a 2.4 × 2.3 μm{sup 2} spot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAXEBIS at GSI as a test ion source for charge breeding and for HITRAP

The electron beam ion source MAXEBIS, developed and built at the University of Frankfurt, has been installed at GSI to serve as an offline test ion source for the HITRAP project and for use as a test setup for charge breeding explorations. The setup has been equipped with new diagnostics and beam optics devices. Two ion sources dedicated to the production of singly charged ions for external ion injection into the MAXEBIS have been included. First time of flight (TOF) spectra with external injected, charge-bred argon ions were taken. However, these spectra indicated beam losses in the beam transport from the multipassage spectrometer (MPS) to the MAXEBIS. In order to understand the losses, the beam transport has been simulated with the SIMION code and the beam line has been modified accordingly. Measurements of the MAXEBIS' beam emittance, using the ''nondestructive'' beam profile method, have been performed as well as measurements of the electron current density via charge state analysis of the TOF spectra. The injection and breeding efficiency of the MAXEBIS have been determined for the first time. The results of the measurements and the planned experiments will be discussed.

43 PARTICLE ACCELERATORS↗

Electron beam quality control using an amorphous silicon EPID

An amorphous silicon EPID has been investigated to determine whether it is capable of quality control constancy measurements for linear accelerator electron beams. The EPID grayscale response was found to be extremely linear with dose over a wide dose range and, more specifically, for exposures of 95-100 MU. Small discrepancies of up to 0.8% in linearity were found at 6 MeV (8-15 MeV showed better agreement). The shape of the beam profile was found to be significantly altered by scatter in air over the approximately 60 cm gap between the end of the applicator and the EPID. Nevertheless, relative changes in EPID-measured profile flatness and symmetry were linearly related to changes in these parameters at 95 cm focus to surface distance (FSD) measured using a 2D diode array. Similar results were obtained at 90 deg. and 270 deg. gantry angles. Six months of daily images were acquired and analyzed to determine whether the device is suitable as a constancy checker. EPID output measurements agreed well with daily ion chamber measurements, with a 0.8% standard deviation in the difference between the two measurement sets. When compared to weekly parallel plate chamber measurements, this figure dropped to 0.5%. A Monte Carlo (MC) model of the EPID was created and demonstrated excellent agreement between MC-calculated profiles in water and the EPID at 95 and 157 cm FSD. Good agreement was also found with measured EPID profiles, demonstrating that the EPID provides an accurate measurement of electron profiles. The EPID was thus shown to be an effective method for performing electron beam daily constancy checks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-technique analysis of deuterium trapping and near-surface precipitate growth in plasma-exposed tungsten

In this work, we examine how deuterium becomes trapped in plasma-exposed tungsten and forms near-surface platelet-shaped precipitates. How these bubbles nucleate and grow, as well as the amount of deuterium trapped within, is crucial for interpreting the experimental database. Here, we use a combined experimental/theoretical approach to provide further insight into the underlying physics. With the Tritium Plasma Experiment, we exposed a series of ITER-grade tungsten samples to high flux D plasmas (up to 1.5 × 10{sup 22 }m{sup −2} s{sup −1}) at temperatures ranging between 103 and 554 °C. Retention of deuterium trapped in the bulk, assessed through thermal desorption spectrometry, reached a maximum at 230 °C and diminished rapidly thereafter for T > 300 °C. Post-mortem examination of the surfaces revealed non-uniform growth of bubbles ranging in diameter between 1 and 10 μm over the surface with a clear correlation with grain boundaries. Electron back-scattering diffraction maps over a large area of the surface confirmed this dependence; grains containing bubbles were aligned with a preferred slip vector along the <111> directions. Focused ion beam profiles suggest that these bubbles nucleated as platelets at depths of 200 nm–1 μm beneath the surface and grew as a result of expansion of sub-surface cracks. To estimate the amount of deuterium trapped in these defects relative to other sites within the material, we applied a continuum-scale treatment of hydrogen isotope precipitation. In addition, we propose a straightforward model of near-surface platelet expansion that reproduces bubble sizes consistent with our measurements. For the tungsten microstructure considered here, we find that bubbles would only weakly affect migration of D into the material, perhaps explaining why deep trapping was observed in prior studies with plasma-exposed neutron-irradiated specimens. We foresee no insurmountable issues that would prevent the theoretical framework developed here from being extended to a broader range of systems where precipitation of insoluble gases in ion beam or plasma-exposed metals is of interest.

36 MATERIALS SCIENCE↗

Deviation from threshold model in ultrafast laser ablation of graphene at sub-micron scale

We investigate a method to measure ultrafast laser ablation threshold with respect to spot size. We use structured complex beams to generate a pattern of craters in CVD graphene with a single laser pulse. A direct comparison between beam profile and SEM characterization allows us to determine the dependence of ablation probability on spot-size, for crater diameters ranging between 700 nm and 2.5 μm. We report a drastic decrease of ablation probability when the crater diameter is below 1 μm which we interpret in terms of free-carrier diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Poster - 21: Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans

Purpose: To determine the source of systematic monitor unit (MU) calculation discrepancies between RadCalc and Eclipse treatment planning software for three-dimensional conformal radiotherapy field-in-field breast treatments. Methods: Data were reviewed for 28 patients treated with a field-in-field breast technique with MU calculations from RadCalc that were larger than MU calculations from Eclipse for at least one field. The distance of the calculation point from the jaws was measured in each field’s beam’s-eye-view and compared with the percentage difference in MU (%ΔMU) between RadCalc and Eclipse. 10×10, 17×13 and 20×20 cm{sup 2} beam profiles were measured using the Profiler 2 diode array for 6-MV photon beams and compared with profiles calculated with Eclipse and RadCalc using a gamma analysis (3%, 3 mm). Results: The mean %ΔMU was 1.3%±0.3%. There was a statistically-significant correlation between %ΔMU and the distance of the calculation point from the Y jaw (r=−0.43, p<0.001). RadCalc profiles differed from measured profiles, especially near the jaws. The gamma pass rate for 6-MV fields of 17×13 cm{sup 2} field size was 95%±1% for Eclipse-generated profiles and 53%±20% for RadCalc-generated profiles (p=0.01). Conclusions: Calculations using RadCalc for field-in-field breast plans resulted in MUs that were larger than expected from previous clinical experience with wedged plans with calculation points far from the jaws due to the position of the calculation point near the jaws in the beam’s-eye-view of each field.

60 APPLIED LIFE SCIENCES↗

Closed-looped in situ nano processing on a culturing cell using an inverted electron beam lithography system

Highlights: ► An electron beam lithography (EBL) was used as an in situ nano processing for a living cell. ► A synchronized optics was containing an inverted EBL and an optical microscope. ► This system visualized real-time images of the EB-induced nano processing. ► We demonstrated the nano processing for a culturing cell with 200–300 nm resolution. ► Our system would be able to provide high resolution display of virtual environments. -- Abstract: The beam profile of an electron beam (EB) can be focused onto less than a nanometer spot and scanned over a wide field with extremely high speed sweeping. Thus, EB is employed for nano scale lithography in applied physics research studies and in fabrication of semiconductors. We applied a scanning EB as a control system for a living cell membrane which is representative of large scale complex systems containing nanometer size components. First, we designed the opposed co-axial dual optics containing inverted electron beam lithography (I-EBL) system and a fluorescent optical microscope. This system could provide in situ nano processing for a culturing living cell on a 100-nm-thick SiN nanomembrane, which was placed between the I-EBL and the fluorescent optical microscope. Then we demonstrated the EB-induced chemical direct nano processing for a culturing cell with hundreds of nanometer resolution and visualized real-time images of the scanning spot of the EB-induced luminescent emission and chemical processing using a high sensitive camera mounted on the optical microscope. We concluded that our closed-loop in situ nano processing would be able to provide a nanometer resolution display of virtual molecule environments to study functional changes of bio-molecule systems.

60 APPLIED LIFE SCIENCES↗

Electrostatic beams from tailored plasmas in a Penning-Malmberg trap

In recent work, a technique was developed to extract high quality beams from single-component plasmas confined in a Penning-Malmberg trap in a 4.8 T magnetic field. In this paper, a procedure is developed to extract these beams from the confining magnetic field and then focus them to create especially tailored electrostatic beams. Electron beams are extracted from the field in two stages: they are first transported to a region of reduced field (1 mT), and then taken to zero field with a nonadiabatic, fast extraction. Once in the field-free region, the beams are focused using an Einzel lens. Experimental results and numerical simulations are presented to illustrate the extraction and focusing process. Theoretical expressions are developed to describe the modifications to the relevant beam energy and spatial distributions. Where possible, analytic expressions are presented for the case relevant here of beams with Gaussian radial profiles. Beam emittance considerations are discussed as well as prospects for further development of these techniques. Application of these techniques to provide high-quality positron beams is also discussed.

43 PARTICLE ACCELERATORS↗

Electron lenses in RHIC: status and prospects

Two electron lenses are installed in Relativistic Heavy Ion Collider (RHIC). They were used as operational head-on beam-beam compensators in proton-proton collisions, with Gaussian transverse electron beam profiles. One of the lenses was also used with a hollow transverse profile to test hadron beam halo removal under various conditions. Although presently not in the design, the lenses may find applications in the Electron-ion Collider (EIC) for either collimation or beam-beam mitigation.

43 PARTICLE ACCELERATORS↗

Design of Electrostatic Aberration Correctors for Scanning Transmission Electron Microscopy

Abstract In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and use of the spent beam for serial operation of LCLS

X-ray free-electron laser sources such as the Linac Coherent Light Source offer very exciting possibilities for unique research. However, beam time at such facilities is very limited and in high demand. This has led to significant efforts towards beam multiplexing of various forms. One such effort involves re-using the so-called spent beam that passes through the hole in an area detector after a weak interaction with a primary sample. This beam can be refocused into a secondary interaction region and used for a second, independent experiment operating in series. The beam profile of this refocused beam was characterized for a particular experimental geometry at the Coherent X-ray Imaging instrument at LCLS. A demonstration of this multiplexing capability was performed with two simultaneous serial femtosecond crystallography experiments, both yielding interpretable data of sufficient quality to produce electron density maps.

43 PARTICLE ACCELERATORS↗

“Metallic burn paper” used for in situ characterization of laser beam properties

In situ ablation of thin metal films on fused silica substrates by picosecond class lasers was investigated in this paper as a method of characterizing the beam at the sample plane. The technique involved plotting the areas enclosed by constant fluence contours identified in optical microscope images of the ablation sites versus the logs of the pulse energies. Inconel films on commercially available neutral density filters as well as magnetron sputtered gold films were used. It was also shown that this technique could be used to calibrate real-time beam profile diagnostics against the beam at the sample plane. Finally, the contours were shown to correspond to the boundary where part or all of the film was ablated.

42 ENGINEERING↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.

43 PARTICLE ACCELERATORS↗

Optimizing 4d Emittance Measurements Using the Pinhole Scan Technique

Accurate measurement of electron beam emittance is essential for optimizing high-brightness electron sources. The Pinhole Scan Technique measures the 4D phase space and hence the emittance by measuring the beam profile after clipping the beam using a pinhole followed by a drift section and then scanning the beam over the pinhole. This technique has been implemented in low energy (< 200 keV) beamlines at both Cornell University and Arizona State University. However, the technique poses several practical challenges. In this work, we analyze and address key issues affecting the 4D phase space and emittance measurements using this technique. We identify and investigate sources of inaccuracies like the pinhole aspect ratio, beam divergence, position-momentum correlations in the phase space, and the point-spread-function of the detector and suggest techniques to minimize them. Our findings offer a pathway to more accurate 4D phase space characterization in advanced electron beam systems.

42 ENGINEERING↗

Flat profile laser beam shaper

A system for shaping a beam comprises an emitter for emitting coherent electromagnetic radiation. Birefringent displacers are configured between the emitter and a target wherein the at least two birefringent displacers split the coherent electromagnetic radiation into a plurality of coherent parallel beams of electromagnetic radiation thereby producing a shaped wave front of the coherent parallel beams of electromagnetic radiation.

43 PARTICLE ACCELERATORS↗

Muon Monitor Data To Maintain The Quality Of The NuMI Neutrino Beam at Fermilab

The NuMI-AIP has been proposed to upgrade the NuMI target system for a 1-MW operation. The facility produces an intense muon neutrino beam by using a high power pion production target and a focusing magnetic horns for long baseline neutrino experiment. A muon monitor which measures muon beam profile, is a key beam element to maintain the quality of muon neutrino beam. The system will be upgraded for the high beam power operation. We studied the response of muon monitors with the proton beam power, proton beam position on the target, and focusing strength of the horn. The results were evaluated for future operations. The response function needs to be modeled by using Machine Learning algorithms which will be implemented into a muon monitor signal analyzer. The new analyzer will forecast the neutrino beam quality and control the beam position on the target if needed. Upgrading the helium gas handling system is the other key to improve the stability of the muon monitor signal. We will present the status of the upgrade plan.

43 PARTICLE ACCELERATORS↗