An Overview of the Enhanced Modified Faraday Cup (EMFC) Electron Beam Power Density Distribution Diagnostic
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided.
Explore the source record for details and available documents.
In an investigation of a beam-plasma discharge (BPD), the electron energy distribution of an electron beam moving through a partially ionized gas is analyzed. Among other results, it is found that the occurrence of BPD heats the initially cold electron beam from the accelerator. The directional intensity of electrons measured outside the beam core indicates that most particles suffer a single scattering in energy and pitch angle. At low currents this result is expected as beam particles collide with the neutral atmosphere, while in BPD the majority of particles is determined to still undergo a single scattering near the original beam core. The extended energy spectra at various beam currents show two rather distinct plasma populations, one centered at the initial beam energy (approximately 1500 eV) and the other at approximately 150 eV.
In the present contribution the temperature distribution in the selective beam melting process for polymer materials is simulated to better understand the influence of process parameters on the properties of the produced part. The basis for the developed simulation tool is the nonlinear heat equation including temperature dependent functions for the heat capacity and the heat conduction which were obtained by experimental measurements. The effect of latent heat occurring in the process is also taken into account. The heat equation is discretized in time and space where a Runge-Kutta method of Radau IIA type is used for time integration. An adaptive finite element method is applied for the discretization in space and the model is implemented into the finite element library deal.II. The heat and cooling rate as important process parameters are simulated for different beam velocities. The ability for computing these process parameters makes the simulation tool suited for optimizing the process management of selective beam melting plants.
Systems and methods for detecting an image of an object using a multi-beam imaging system from an x-ray beam having a polychromatic energy distribution are disclosed. According to one aspect, a method can include generating a first X-ray beam having a polychromatic energy distribution. Further, the method can include positioning a plurality of monochromator crystals in a predetermined position to directly intercept the first X-ray beam such that a plurality of second X-ray beams having predetermined energy levels are produced. Further, an object can be positioned in the path of the second X-ray beams for transmission of the second X-ray beams through the object and emission from the object as transmitted X-ray beams. The transmitted X-ray beams can each be directed at an angle of incidence upon one or more crystal analyzers. Further, an image of the object can be detected from the beams diffracted from the analyzer crystals.
Bounds for natural frequency eigenvalues of simply supported uniform beam with constant end load and uniformly distributed axial load
Systems and methods for detecting an image of an object using an X-ray beam having a polychromatic energy distribution are disclosed. According to one aspect, a method can include detecting an image of an object. The method can include generating a first X-ray beam having a polychromatic energy distribution. Further, the method can include positioning a single monochromator crystal in a predetermined position to directly intercept the first X-ray beam such that a second X-ray beam having a predetermined energy level is produced. Further, an object can be positioned in the path of the second X-ray beam for transmission of the second X-ray beam through the object and emission from the object as a transmitted X-ray beam. The transmitted X-ray beam can be directed at an angle of incidence upon a crystal analyzer. Further, an image of the object can be detected from a beam diffracted from the analyzer crystal.
The distribution of stress in the cover sheets of thin-wall box beams is analyzed, with regard to the effect of shear deformation in the cover sheets, by the method of least work. Explicit results are obtained for a number of representative cases that show the influence of the following factors on the stress patterns. (1) Variation of stress in spanwise direction as given by elementary beam theory. (2) Value of a parameter called shear-lag aspect ratio which designates the product of span-width ratio of the beam and of the square root of the ratio of effective shear modulus and tensing modulus of the cover sheets. (3) Value of ratio of cover-sheet stiffness to side-web stiffness. (4) Variation of beam height in span direction. (5) Variation of beam width in span direction. (6) Variation of cover-sheet thickness in span direction. General conclusions are drawn from the results obtained. Among them the most important one appears to be the fact that the shear-lag effect depends primarily on the following tow quantities: (1) the value of the shear-lag aspect ratio. (2) the shape of the curve representing the product of the stress of elementary beam theory and of the cover-sheet thickness.
Strong turbulence and transit-time scattering theory are applied here to calculate the statistical distribution of intense Langmuir fields and the consequent beam scattering in plasma turbulence driven by an electron beam. The experimentally observed electric-field distributions are compared with predictions of strong-turbulence theory, concentrating on the wave levels, the Gaussian tail of the high-field distribution observed in one experiment, the arrest scale of collapse, and the fractional volume occupied by the highest fields. The Guassian form of the tail is confirmed, and the results imply that the collapse is arrested at a scale where the peak electrostatic energy density is of the same order as the thermal energy density. The theory of transit-time interactions is generalized to include relativistic particle dynamics and is applied to predict the scattering of the beam electrons in energy and angle as they pass through strong Langmuir turbulence. The results support the validity of the recently developed scaling theory of strong turbulence.
Purpose: To assess the impact of the detector used to commission small photon beams on the calculated dose distribution in stereotactic radiosurgery (SRS). Methods: In this study, six types of detectors were used to characterize small photon beams: three diodes [a silicon stereotactic field diode SFD, a silicon diode SRS, and a silicon diode E], an ionization chamber CC01, and two types of radiochromic film models EBT and EBT2. These detectors were used to characterize circular collimated beams that were generated by a Novalis linear accelerator. This study was conducted in two parts. First, the following dosimetric data, which are of particular interest in SRS, were compared for the different detectors: the total scatter factor (TSF), the tissue phantom ratios (TPRs), and the off-axis ratios (OARs). Second, the commissioned data sets were incorporated into the treatment planning system (TPS) to compare the calculated dose distributions and the dose volume histograms (DVHs) that were obtained using the different detectors. Results: The TSFs data measured by all of the detectors were in good agreement with each other within the respective statistical uncertainties: two exceptions, where the data were systematically below those obtained for the other detectors, were the CC01 results for all of the circular collimators and the EBT2 film results for circular collimators with diameters below 10.0 mm. The OAR results obtained for all of the detectors were in excellent agreement for all of the circular collimators. This observation was supported by the gamma-index test. The largest difference in the TPR data was found for the 4.0 mm circular collimator, followed by the 10.0 and 20.0 mm circular collimators. The results for the calculated dose distributions showed that all of the detectors passed the gamma-index test at 100% for the 3 mm/3% criteria. The aforementioned observation was true regardless of the size of the calculation grid for all of the circular collimators. Finally, the dose volume histogram results were independent of the size of the calculation grid used. Conclusions: The results of this study showed that all of the studied detectors produced similar commissioned data sets for the TPS dose calculations. However, this result only validated the dose distribution calculation in the TPS and could not be used to assess the dose delivery to the target in which the TFS data were used to calculate the monitor units (the TFS data were not used in the TPS dose distribution calculation). Therefore, this study could not be used to determine the most accurate detector commissioning data set; however, all of the detectors exhibited superior performance for the relative dosimetry of small photon beams.
For this work, we have inferred the energy distribution of trapped ions in an electron beam ion trap (EBIT) from simulations of the spatial distribution of Fe 13+ ions and a comparison with measured visible light images of the ion cloud. We simulated the cloud of Fe 13+ ions by computing ion trajectories in the EBIT for different ion energy distributions used to initialize the trajectories. We then performed a least-squares fit to infer the ion energy distribution that best reproduced the measured ion cloud. These best-fit distributions were typically non-Maxwellian. For electron beam energies of 395–475 eV and electron beam currents of 1–9 mA, we find that the average ion energy is in the range of 10–300 eV. We also find that the average ion energy increases with increasing beam current approximately as $\langle$E$\rangle$ ≈ 25 I e eV, where I e is the electron beam current in mA. We have also compared our results to Maxwell-Boltzmann-distribution ion clouds. We find that our best-fit non-thermal distributions have an $\langle$E$\rangle$ that is less than half that of the T from the best-fit Maxwell-Boltzmann distributions ($\langle$E$\rangle$/q)/T=0.41 ± 0.05.
Purpose It has been demonstrated that the use of noncoplanar beams in radiation therapy may Result in dose distributions that are comparable or better than standard coplanar beams [Pugachev, 2001]. A radiation therapy system designed with a noncoplanar beam geometry could allow for a full ring diagnostic quality imaging system to be placed around the patient. Additionally, if the noncoplanar beams were fixed in number and in their angle with respect to the patient’s axial plane, then both treatment and imaging could be achieved concurrently without the need for moving parts, which could greatly reduce treatment times. For such a system to be designed, it is necessary to determine the appropriate number of beams and the beam angles to achieve optimal dose distributions. For simplicity, the beam angles are assumed to be equiangular in the patient’s axial plane, and only the beam angle with respect to the axial plane are varied. This study aims to investigate the dose distributions produced by equiangular noncoplanar beams for multiple beam numbers and beam angles, and to compare these dose distributions with distributions achieved in coplanar volumetric arc therapy (VMAT). Methods Dose distributions produced by noncoplanar beams were calculated using the Varian Eclipse treatment planning system by varying the gantry, collimator, and couch angles to simulate the noncoplanar delivery method. Noncoplanar intensity-modulated (NC-IMRT) beams using 8, 12, and 16 beams with angles varying from 45 degrees to 54 with respect to the patient’s axial plane were studied. Results The NC-IMRT beams produced dose distributions comparable to VMAT plans for a number of treatment sites, and were capable of meeting similar dose-volume histogram constraints. Conclusion This study has demonstrated that a noncoplanar beam delivery method with fixed beam numbers and beam angles is capable of delivering dose distributions comparable to VMAT plans currently in use.
The compositional distribution of In atoms in InGaN/GaN multiple quantum wells is considered as one of the candidates for carrier localization center, which enhances the efficiency of the light-emitting diodes. However, two challenging issues exist in this research area. First, an inhomogeneous In distribution is initially formed by spinodal decomposition during device fabrication as revealed by transmission electron microscopy. Second, electron-beam irradiation during microscopy causes the compositional inhomogeneity of In to appear as a damage contrast. Here, a systematic approach was proposed in this study: Electron-beam with current density ranging from 0 to 20.9 A/cm{sup 2} was initially exposed to the surface regions during microscopy. Then, the electron-beam irradiated regions at the tip surface were further removed, and finally, atom probe tomography was performed to run the samples without beam-induced damage and to evaluate the existence of local inhomegenity of In atoms. We proved that after eliminating the electron-beam induced damage regions, no evidence of In clustering was observed in the blue-emitting InGaN/GaN devices. In addition, it is concluded that the electron-beam induced localization of In atoms is a surface-related phenomenon, and hence spinodal decomposition, which is typically responsible for such In clustering, is negligible for biaxially strained blue-emitting InGaN/GaN devices.
Using combined MHD/test particle simulations, we further explore characteristic ion velocity distributions in relation to magnetotail reconnection and dipolarization events, focusing on distributions at and near the plasma sheet boundary layer (PSBL). Simulated distributions right at the boundary are characterized by a single earthward beam, as discussed earlier. However, farther inside, the distributions consist of multiple beams parallel and antiparallel to the magnetic field, remarkably similar to recent Magnetospheric Multiscale observations. The simulations provide insight into the mechanisms: the lowest earthward beam results from direct acceleration at an earthward propagating dipolarization front (DF), with a return beam at somewhat higher energy. A higher-energy earthward beam results from dual acceleration, first near the reconnection site and then at the DF, again with a corresponding return beam resulting from mirroring closer to Earth. Multiple acceleration at the X line or the propagating DF with intermediate bounces may produce even higher-energy beams. Particles contributing to the lower energy beams are found to originate from the PSBL with thermal source energies, increasing with increasing beam energy. In contrast, the highest-energy beams consist mostly of particles that have entered the acceleration region via cross-tail drift with source energies in the suprathermal range.
Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K{sub air}), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses than K{sub air} and KAP, with average ratios ranging between 0.9 and 1.1 and variations for different organs and protocols below 20%. The triple phantom setup allowed us to take into account scatter dose contributions, but nonetheless, the correlation with the evaluated organ doses was not improved with this method. Conclusions: The simulation of rotational geometry and of asymmetric beam distribution by means of PCXMC 2.0 enabled us to determine patient organ doses depending on weight, height and gender. Alternatively, the measurement of an in phantom dose indicator combined with proper correction coefficients can be a useful tool for a first dose estimation of in-field organs. The data and coefficients provided in this study can be applied to any patient undergoing a scan by an Elekta XVI equipment.
A robust control system is presented for damping vibrations in a cantilevered beam. The distributed deflections of the beam are sensed using real-time holography. A hybrid processor which uses optical and digital processors is proposed to implement a distributed control algorithm. The controller is designed using the linear-quadratic-Gaussian method to add damping to a finite number of vibrational modes.
Photographs of cross sections of an electron beam scattered from thin foils have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of particles both reflected from a foil and passed through it. The spatial distribution of electrons incident on aluminum, copper, and lead foils, as well as on bimetallic foils composed of aluminum and lead layers and of aluminum and copper layers, has been measured. The effect of the material and thickness of the foil, as well as of the angle between the initial beam trajectory and the target plane, on the spatial distribution of electrons has been studied. The effect of the sequence of the metal layers in bimetallic foils on the distribution of beams has been analyzed. A 7.4-MeV microtron has been used as a source of electrons.