Use of a Heat Flow Meter to Determine Active PCM Content in an Insulation

Residential and commercial roofs and walls are currently designed and tested using steady-state criteria. The resulting R-values, based on the apparent thermal conductivity, are used by building standards as an important measure of energy performance. Building envelope components, however, are subject to dynamic environmental conditions. This mismatch between the steady-state principles used in design and code requirements and their dynamic operation results in relatively low thermal efficiencies. Although several research centers have developed experimental methods for transient analysis of building envelopes, there are no standardized testing procedures available for screening materials and systems for which performance depends on dynamic response. For example, a full-scale dynamic evaluation of phase change materials (PCMs) is needed to assess their energy saving benefits. A nationally accepted small-scale (one to two foot size specimens) testing procedure is not available for the analysis of dynamic thermal characteristics of conventional thermal mass systems or PCM-enhanced materials. At the same time, data on these characteristics are necessary for whole-building simulations, energy analysis, and energy code work. The transient characteristics of PCM-enhanced products depend on the PCM content and quality. The only readily available method of thermal evaluation uses the differential scanning calorimeter. Unfortunately, this method requires small, relatively uniform test specimens. This requirement is unrealistic in the case of PCM-enhanced building envelope products such as PCM-cellulose, PCM-glass fiber, or PCM-gypsum blends. Small specimens are not representative of PCM-based blends, since these materials are not homogeneous. Jan Kosny and David Yarbrough, Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN 37831-6070. Elizabeth Kossecka, Polish Academy of Sciences, Institute of Fundamental Technological Research, Pawinskiego 5 B, 02-106, Warsaw, Poland. A procedure for making dynamic heat-flow measurements using existing instrumentation has been developed to analyze the benefits of thermal storage. This small-scale testing method is useful for thermal analysis and as a potential quality control method for producers of PCM-enhanced building materials. The research may provide the basis for consensus standard development. This paper uses as an example a dynamic testing process for PCM-enhanced cellulose insulation.

25 ENERGY STORAGE↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Increasing Flexibility in Energy Code Compliance: Performance Packages

Energy codes and standards have provided significant increases in building efficiency over the last 38 years, since the first national energy code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. As the code matures, the prescriptive path becomes more complicated, and also more restrictive. It is likely that an approach that considers the building as an integrated system will be necessary to achieve the next real gains in building efficiency. Performance code paths are increasing in popularity; however, there remains a significant design team overhead in following the performance path, especially for smaller buildings. This paper focuses on development of one alternative format, prescriptive packages. A method to develop building-specific prescriptive packages is reviewed based on a multiple runs of prototypical building models that are used to develop parametric decision analysis to determines a set of packages with equivalent energy performance. The approach is designed to be cost-effective and flexible for the design team while achieving a desired level of energy efficiency performance. A demonstration of the approach based on mid-sized office buildings with two HVAC system types is shown along with a discussion of potential applicability in the energy code process.

Hart, Philip R.↗

Increasing Flexibility in Energy Code Compliance: Performance Packages

Energy codes and standards have provided significant increases in building efficiency over the last 38 years, since the first national energy code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. As the code matures, the prescriptive path becomes more complicated, and also more restrictive. It is likely that an approach that considers the building as an integrated system will be necessary to achieve the next real gains in building efficiency. Performance code paths are increasing in popularity; however, there remains a significant design team overhead in following the performance path, especially for smaller buildings. This paper focuses on development of one alternative format, prescriptive packages. A method to develop building-specific prescriptive packages is reviewed based on a multiple runs of prototypical building models that are used to develop parametric decision analysis to determines a set of packages with equivalent energy performance. The approach is designed to be cost-effective and flexible for the design team while achieving a desired level of energy efficiency performance. A demonstration of the approach based on mid-sized office buildings with two HVAC system types is shown along with a discussion of potential applicability in the energy code process.

Hart, Reid↗

Envelope Air Tightness for Sleeping and Dwelling Units

This technical brief investigates the potential benefits of air leakage testing in residential buildings covered by the commercial energy code and outlines an approach that could be applied based on building type, use, size and climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of the 2009 IECC for Residential Buildings at State Level

This report examines the requirements of the 2009 International Energy Conservation Code® (IECC) on residential buildings on a state-by-state basis with a separate, stand-alone chapter for each state. A summary of the requirements of the code is given for each state. The 2009 IECC is then compared to the current state code for most states or typical current construction practice for the states that do not have a residential energy efficiency code. This is the final version of a draft report by the same name that was previously cleared for release (ERICA # PNNL-18545).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of future weather data for assessing climate change impacts on buildings and energy systems

The effectiveness of climate change impact assessments and the development of adaptation strategies depend on the availability of high-quality future weather data. However, significant gaps exist between the needs of the energy research community and the focus of the climate modeling community, primarily due to a historical lack of communication and collaboration between the two groups. Here, to address this issue, this work provides a comprehensive overview of the critical aspects involved in creating future weather data for building and energy system modeling, including emissions scenarios, general circulation models, downscaling methods, categories of future weather data, and uncertainties in climate simulations. Moreover, it critically evaluates the applicability and suitability of various types of future weather data in five key application scenarios: energy use analysis, resilience analysis, HVAC design, utility-scale analysis, and renewable energy analysis. Finally, this work presents recommendations for high-level actions and research directions to foster collaboration between the energy research and climate modeling communities and to promote the integration of future weather data into energy codes and the design practices of buildings and energy systems.

Climate change↗

Results and Lessons Learned From the DOE Commercial Building Partnerships: Preprint

Over the course of 5 years, NREL worked with commercial building owners and their design teams in the DOE Commercial Building Partnerships (CBP) to cut energy consumption by 50% in new construction (versus code) and by 30% in existing building pilot projects (versus code or pre-retrofit operational energy use depending on the preference of the Partner) using strategies that could be replicated across their building portfolios. A number of different building types were addressed, including supermarket, retail merchandise, combination big box (general merchandise and food sales), high rise office space, and warehouse. The projects began in pre-design and included a year of measurement data to evaluate performance against design expectations. Focused attention was required throughout the entire process to achieve a design with the potential to hit the energy performance target and to operate the resulting building to reach this potential. This paper will report quantitative results and cover both the technical and the human sides of CBP, including the elements that were required to succeed and where stumbling blocks were encountered. It will also address the impact of energy performance goals and intensive energy modeling on the design process innovations and best practices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Control Ventilation - Code Notes

A demand control ventilation system is an integral part of a building’s ventilation design. It adjusts outside ventilation air based on the number of occupants and the ventilation demands that those occupants create.

HVAC, sensors and controls, building energy effici↗

National Energy Codes and Standards What they mean to the electrical inspector now and in the future.

Most electrical inspectors never evaluate completed residential and commercial buildings with respect to energy efficiency provisions adopted and enforced by a state or jurisdiction. Why? Electrical-plan review and inspection do not typically involve energy provisions and, more significantly, most electrical inspections occur before energy-saving measures are even installed. These final inspections are typically the responsibility of the building inspector. However, while the roles of building and electrical inspectors are different, they are complementary. Understanding these roles and the code requirements they involve furthers the primary goal of both electric and energy codes—the construction of safe and energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2022

The purpose of this analysis is to examine the cost-effectiveness of the 2022 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1 and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2022, compared to the previous 90.1-2019 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated energy codes. This information also informs the development of future editions of Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

On the Need for a Unified and Collaboratively Developed Residential Building Simulation Platform: Preprint

Residential building energy simulations are becoming ever more pervasive; they form the basis of energy efficient building design, zero energy goals, codes and standards, home certification and ratings industries, utility programs, regional/state planning, and technology assessments. And yet the residential building simulation community is highly fragmented with a patchwork of simulation engines with varying models, inputs, assumptions, and results. This inconsistency degrades confidence in these tools, increases industry-wide development and maintenance costs, and slows the availability of new efficiency technology models. The need for collaboration on an impartial, transparent, and capable residential building simulation platform has never been greater. But to develop and maintain a state-of-the-art simulation platform requires a dedicated and sustained investment. By leveraging existing resources and expertise from multiple entities/regions, a unified and collaboratively developed simulation platform can provide increased levels of energy efficiency at an accelerated pace. This paper presents the advantages and disadvantages of a unified residential building simulation platform in relationship to four real-world examples (RESNET HERS ratings, utility programs, California's Title 24, and DOE). The paper covers recent developments and improved capabilities that may move us closer to an ideal simulation platform and what challenges remain. The hope is to spur a frank and honest dialogue about how to work together towards the vision of achieving deeper and more reliable energy savings in the residential buildings industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Need for a Unified and Collaboratively Developed Residential Building Simulation Platform

Residential building energy simulations are becoming ever more pervasive; they form the basis of energy efficient building design, zero energy goals, codes and standards, home certification and ratings industries, utility programs, regional/state planning, and technology assessments. And yet the residential building simulation community is highly fragmented with a patchwork of simulation engines with varying models, inputs, assumptions, and results. This inconsistency degrades confidence in these tools, increases industry-wide development and maintenance costs, and slows the availability of new efficiency technology models. The need for collaboration on an impartial, transparent, and capable residential building simulation platform has never been greater. But to develop and maintain a state-of-the-art simulation platform requires a dedicated and sustained investment. By leveraging existing resources and expertise from multiple entities/regions, a unified and collaboratively developed simulation platform can provide increased levels of energy efficiency at an accelerated pace. This paper presents the advantages and disadvantages of a unified residential building simulation platform in relationship to four real-world examples (RESNET HERS ratings, utility programs, California's Title 24, and DOE). The paper covers recent developments and improved capabilities that may move us closer to an ideal simulation platform and what challenges remain. The hope is to spur a frank and honest dialogue about how to work together towards the vision of achieving deeper and more reliable energy savings in the residential buildings industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of the Residential Provisions of the 2024 IECC

This analysis focuses on single-family and low-rise multifamily residential buildings based on the International Energy Conservation Code (IECC). The IECC is developed by the International Code Council (ICC) on a 3-year cycle through a public development and consensus process. While proponents of code changes often include the energy and cost-effectiveness criteria for their respective code change, the IECC process does not include an energy or cost-effectiveness analysis of the entire edition of the code. PNNL evaluated the cost effectiveness of the changes in the prescriptive and mandatory residential provisions of the 2024 edition of the IECC, hereafter referred as the 2024 IECC, compared to those in the prior edition, the 2021 IECC. The simulated performance path and the Energy Rating Index (ERI) path (introduced in the 2015 IECC) are not considered in this analysis due to the wide variation in building construction characteristics that are allowed.

2024 IECC↗

Methodological Framework for Analysis of Buildings-Related Programs with BEAMS, 2008

The U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) develops official “benefits estimates” for each of its major programs using its Planning, Analysis, and Evaluation (PAE) Team. PAE conducts an annual integrated modeling and analysis effort to produce estimates of the energy, environmental, and financial benefits expected from EERE’s budget request. These estimates are part of EERE’s budget request and are also used in the formulation of EERE’s performance measures. Two of EERE’s major programs are the Building Technologies Program (BT) and the Weatherization and Intergovernmental Program (WIP). Pacific Northwest National Laboratory (PNNL) supports PAE by developing the program characterizations and other market information necessary to provide input to the EERE integrated modeling analysis as part of PAE’s Portfolio Decision Support (PDS) effort. Additionally, PNNL also supports BT by providing line-item estimates for the Program’s internal use. PNNL uses three modeling approaches to perform these analyses. This report documents the approach and methodology used to estimate future energy, environmental, and financial benefits using one of those methods: the Building Energy Analysis and Modeling System (BEAMS). BEAMS is a PC-based accounting model that was built in Visual Basic by PNNL specifically for estimating the benefits of buildings-related projects. It allows various types of projects to be characterized including whole-building, envelope, lighting, and equipment projects. This document contains an overview section that describes the estimation process and the models used to estimate energy savings. The body of the document describes the algorithms used within the BEAMS software. This document serves both as stand-alone documentation for BEAMS, and also as a supplemental update of a previous document, Methodological Framework for Analysis of Buildings-Related Programs: The GPRA Metrics Effort, (Elliott et al. 2004b). The areas most changed since the publication of that previous document are those discussing the calculation of lighting and HVAC interactive effects (for both lighting and envelope/whole-building projects). This report does not attempt to convey inputs to BEAMS or the methodology of their derivation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Colorado Better Buildings Project. Final Report

The Colorado Better Buildings project intended to bring new and existing energy efficiency model programs to market with regional collaboration and funding partnerships. The goals for Boulder County and its program partners were to advance energy efficiency investments, stimulate economic growth in Colorado and advance the state’s energy independence. Collectively, three counties set out to complete 9,025 energy efficiency upgrades in 2.5 years and they succeeded in doing so. Energy efficiency upgrades have been completed in more than 11,000 homes and businesses in these communities. Boulder County and its partners received a $25 million BetterBuildings grant from the U.S. Department of Energy under the American Recovery and Reinvestment Act in the summer of 2010. This was also known as the Energy Efficiency and Conservation Block Grants program. With this funding, Boulder County, the City and County of Denver, and Garfield County set out to design programs for the residential and commercial sectors to overcome key barriers in the energy upgrade process. Since January 2011, these communities have paired homeowners and business owners with an Energy Advisor – an expert to help move from assessment to upgrade with minimal hassle. Pairing this step-by-step assistance with financing incentives has effectively addressed many key barriers, resulting in energy efficiency improvements and happy customers. An expert energy advisor guides the building owner through every step of the process, coordinating the energy assessment, interpreting results for a customized action plan, providing a list of contractors, and finding and applying for all available rebates and low-interest loans. In addition to the expert advising and financial incentives, the programs also included elements of social marketing, technical assistance, workforce development and contractor trainings, project monitoring and verification, and a cloud-based customer data system to coordinate among field advisors and across local governments and local service vendors. A portion of the BetterBuildings grant went to the Metro Mayors Caucus (MMC) who worked in partnership with the Denver Regional Council of Governments (DRCOG) to conduct a series of 10 energy efficiency workshops for local government officials and other interested parties. The workshops helped showcase lessons learned on energy efficiency and helped guide other local governments in the establishment of similar programs. The workshops covered a wide range of energy efficiency and renewable energy topics such as clean energy finance, social mobilization and communications, specific case studies of Colorado towns, energy efficiency codes, net zero buildings and solar power. Since the programs launched in January 2011, these communities have collectively spurred economic investments in energy efficiency, achieved greater than 5:1 leveraging of grant funds, saved energy and reduced greenhouse gas emissions, provided trainings for a robust local energy contractor network, and proved out viable and replicable program models that local utilities and other communities are adopting, with long lasting market transformation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large Hospital 50% Energy Savings: Technical Support Document

This Technical Support Document documents the technical analysis and design guidance for large hospitals to achieve whole-building energy savings of at least 50% over ANSI/ASHRAE/IESNA Standard 90.1-2004 and represents a step toward determining how to provide design guidance for aggressive energy savings targets. This report documents the modeling methods used to demonstrate that the designrecommendations meet or exceed the 50% goal. EnergyPlus was used to model the predicted energy performance of the baseline and low-energy buildings to verify that 50% energy savings are achievable. Percent energy savings are based on a nominal minimally code-compliant building and whole-building, net site energy use intensity. The report defines architectural-program characteristics for typicallarge hospitals, thereby defining a prototype model; creates baseline energy models for each climate zone that are elaborations of the prototype models and are minimally compliant with Standard 90.1-2004; creates a list of energy design measures that can be applied to the prototype model to create low-energy models; uses industry feedback to strengthen inputs for baseline energy models andenergy design measures; and simulates low-energy models for each climate zone to show that when the energy design measures are applied to the prototype model, 50% energy savings (or more) are achieved.