Rapid Application Development with OpenStudio: Preprint

This paper presents several case studies of rapidly implemented, audience-specific applications for whole building energy modeling and standards analysis. By tailoring each application to the audience and the task at hand, the required learning curve for new users was greatly reduced. Each case study used OpenStudio, the U.S. Department of Energy's middleware software development kit (SDK).OpenStudio provides an easy interface to the EnergyPlus whole building simulation engine, while extending its capability and providing higher-level functionality such as software interoperability, standards, analysis, and optimization. Each case study is unique in the technology employed to interface with OpenStudio as well as the methods used for user interaction and data presentation. Fourcase studies are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

This report serves as the first-year deliverable for a multiyear project that intends to produce a set of highly resolved electricity end-use load profiles (EULPs) of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control

Optimizing whole house mechanical ventilation as part of the Building America program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this report is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End Use Load Profiles for the U.S. Building Stock

End Use Load Profiles for the U.S. Building Stock is a multiyear project to produce a set of highly resolved electricity end-use load profiles (EULPs) of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs. This presentation provides an overview of the project approach, status, goals, and challenges, and discusses what the project means for the Northeast region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Forecasting Peak Electricity Demand for Los Angeles Considering Higher Air Temperatures due to Climate Change

We report that Los Angeles County (LAC) is a large urbanized region with 9.7 million residents (as of 2010) and aging infrastructure. Population forecasts indicate that LAC will become home to an additional 1.2-3.1 million residents through 2060. Additionally, climate forecasts based upon representative concentration pathway (RCP) scenarios 4.5 and 8.5 indicate that average air temperatures will increase by 1-4 degrees C (2-7 degrees F) in the region. Both of these factors are expected to result in higher summertime peak electricity demand due to growth in the number of buildings, the percentage of installed air conditioners (ACs), and the additional cooling load on those air conditioners. In order to understand potential power reliability issues, and support infrastructure planning efforts, a long-term peak demand forecast was developed using hourly residential and commercial (R&C) building energy models. Peak hour electricity demand was estimated to increase from 9.5 to 12.8 GW for R&C sectors, to 13.0-17.3 GW (2-36%) and 14.7-19.2 GW (16-51%) by 2060 for the population forecasts from the California Department of Finance and the Southern California Association of Governments respectively. While marginal increases in ambient air temperature due to climate change accounted for only 4-8% of future increases in peak demand, differences in annual maximum temperatures within the 20-year periods affected results by 40-66% indicating a high sensitivity to heat waves. Population growth of at least 1 million people is anticipated to occur mostly in the northern cities of Palmdale, Lancaster, and Santa Clarita, bringing an additional 0.4-1 GW of peak demand in those regions. Building and AC efficiency are anticipated to improve as national and state efficiency standards increase, and as older, less efficient units are replaced; this could offset some of the projected increases in peak demand. Furthermore, development of shared wall, multi-family dwelling units could enable population growth of up to 3 million people without increasing peak demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Leveraging OpenStudio's Application Programming Interfaces: Preprint

OpenStudio development efforts have been focused on providing Application Programming Interfaces (APIs) where users are able to extend OpenStudio without the need to compile the open source libraries. This paper will discuss the basic purposes and functionalities of the core libraries that have been wrapped with APIs including the Building Model, Results Processing, Advanced Analysis, UncertaintyQuantification, and Data Interoperability through Translators. Several building energy modeling applications have been produced using OpenStudio's API and Software Development Kits (SDK) including the United States Department of Energy's Asset ScoreCalculator, a mobile-based audit tool, an energy design assistance reporting protocol, and a portfolio scale incentive optimization analysismethodology. Each of these software applications will be discussed briefly and will describe how the APIs were leveraged for various uses including high-level modeling, data transformations from detailed building audits, error checking/quality assurance of models, and use of high-performance computing for mass simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Efficient Electric Vehicle Adoption With Level 2 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Efficient Electric Vehicle Adoption With Level 2 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 1 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 1 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 2 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 2 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Efficient Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Efficient Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating traffic-based building occupancy schedules in Chattanooga, Tennessee from a grid of traffic sensors

Building occupancy significantly impacts energy use, timing for demand impacts, and is a significant source of uncertainty in building energy models. There are relatively few sources that define building occupancy schedules and number of occupants per building or space type. More importantly, these sources define traditional schedules that are likely not to reflect the true occupancy of a given building. We construct traffic-based occupancy schedules which are more responsive to changes in mobility patterns, and which can realistically estimate occupant arrivals, departures, and counts in individual buildings.

Berres, Andy↗

Scalable methodology for large scale building energy improvement: Relevance of calibration in model-based retrofit analysis

The increasing interest in retrofitting of existing buildings is motivated by the need to make a major contribution to enhancing building energy efficiency and reducing energy consumption and CO2 emission by the built environment. This paper examines the relevance of calibration in model-based analysis to support decision-making for energy and carbon efficiency retrofits of individual buildings and portfolios of buildings. The authors formulate a set of real retrofit decision-making situations and evaluate the role of calibration by using a case study that compares predictions and decisions from an uncalibrated model with those of a calibrated model. The case study illustrates both the mechanics and outcomes of a practical alternative to the expert- and time-intense application of dynamic energy simulation models for large-scale retrofit decision-making under uncertainty.

Heo, Yeonsook↗

Occupancy Simulator Solver v1.0

Occupant schedules at room level are crucial information to building energy modeling which quantifies occupant-related energy efficiency technologies and controls for new building design as well as existing building retrofits to reduce energy use and GHG emissions in buildings. The Occupancy Simulator Solver is an executable software component that simulates the stochastic behavior of occupant presence and movement in a building using the Markov-chain model. Occupancy Simulator Solver is the calculation engine of the web App Occupancy Simulator, which takes high level input on occupants, spaces and events, then calls the Solver to simulate occupant movement and generate occupant schedules for each space. The generated schedules capture diversity and stochastic nature of occupant activities (e.g., in office, meetings, breaks, lunch). These schedules are stored in CSV files and can be downloaded from the App and used for building performance simulation.