Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress.

60 APPLIED LIFE SCIENCES↗

The innate and adaptive immune response induced by alveolar macrophages exposed to ambient particulate matter

Emerging epidemiological evidence suggests that exposure to particulate matter (PM) air pollution increases the risk of cardiovascular events but the exact mechanism by which PM has adverse effects is still unclear. Alveolar macrophages (AM) play a major role in clearing and processing inhaled PM. This comprehensive review of research findings on immunological interactions between AM and PM provides potential pathophysiological pathways that interconnect PM exposure with adverse cardiovascular effects. Coarse particles (10 {mu}m or less, PM{sub 10}) induce innate immune responses via endotoxin-toll-like receptor (TLR) 4 pathway while fine (2.5 {mu}m or less, PM{sub 2.5}) and ultrafine particles (0.1 {mu}m or less, UFP) induce via reactive oxygen species generation by transition metals and/or polyaromatic hydrocarbons. The innate immune responses are characterized by activation of transcription factors [nuclear factor (NF)-{kappa}B and activator protein-1] and the downstream proinflammatory cytokine [interleukin (IL)-1{beta}, IL-6, and tumor necrosis factor-{alpha}] production. In addition to the conventional opsonin-dependent phagocytosis by AM, PM can also be endocytosed by an opsonin-independent pathway via scavenger receptors. Activation of scavenger receptors negatively regulates the TLR4-NF-{kappa}B pathway. Internalized particles are subsequently subjected to adaptive immunity involving major histocompatibility complex class II (MHC II) expression, recruitment of costimulatory molecules, and the modulation of the T helper (Th) responses. AM show atypical antigen presenting cell maturation in which phagocytic activity decreases while both MHC II and costimulatory molecules remain unaltered. PM drives AM towards a Th1 profile but secondary responses in a Th1- or Th-2 up-regulated milieu drive the response in favor of a Th2 profile.

60 APPLIED LIFE SCIENCES↗

Polycyclic aromatic hydrocarbons as skin carcinogens: Comparison of benzo[a]pyrene, dibenzo[def,p]chrysene and three environmental mixtures in the FVB/N mouse

The polycyclic aromatic hydrocarbon (PAH), benzo[a]pyrene (BaP), was compared to dibenzo[def,p]chrysene (DBC) and combinations of three environmental PAH mixtures (coal tar, diesel particulate and cigarette smoke condensate) using a two stage, FVB/N mouse skin tumor model. DBC (4 nmol) was most potent, reaching 100% tumor incidence with a shorter latency to tumor formation, less than 20 weeks of 12-O-tetradecanoylphorbol-13-acetate (TPA) promotion compared to all other treatments. Multiplicity was 4 times greater than BaP (400 nmol). Both PAHs produced primarily papillomas followed by squamous cell carcinoma and carcinoma in situ. Diesel particulate extract (1 mg SRM 1650b; mix 1) did not differ from toluene controls and failed to elicit a carcinogenic response. Addition of coal tar extract (1 mg SRM 1597a; mix 2) produced a response similar to BaP. Further addition of 2 mg of cigarette smoke condensate (mix 3) did not alter the response with mix 2. PAH-DNA adducts measured in epidermis 12 h post initiation and analyzed by {sup 32}P post‐labeling, did not correlate with tumor incidence. PAH‐dependent alteration in transcriptome of skin 12 h post initiation was assessed by microarray. Principal component analysis (sum of all treatments) of the 922 significantly altered genes (p < 0.05), showed DBC and BaP to cluster distinct from PAH mixtures and each other. BaP and mixtures up-regulated phase 1 and phase 2 metabolizing enzymes while DBC did not. The carcinogenicity with DBC and two of the mixtures was much greater than would be predicted based on published Relative Potency Factors (RPFs). -- Highlights: ► Dibenzo[def,p]chrysene (DBC), 3 PAH mixtures, benzo[a]pyrene (BaP) were compared. ► DBC and 2 PAH mixtures were more potent than Relative Potency Factor estimates. ► Transcriptome profiles 12 hours post initiation were analyzed by microarray. ► Principle components analysis of alterations revealed treatment-based clustering. ► DBC gave a unique pattern of gene alterations compared to BaP and PAH mixtures.

60 APPLIED LIFE SCIENCES↗

Determination of heavy metals and halogens in plastics from electric and electronic waste

The presence of hazardous substances and preparations in small waste electrical and electronic equipment (sWEEE) found in the residual household waste stream of the city of Dresden, Germany has been investigated. The content of sWEEE plastics in heavy metals and halogens is determined using handheld X-ray fluorescence analysis (HXRF), elemental analysis by means of atomic absorption spectrometry (AAS) and ion exchange chromatography (IEC). Mean value of results for heavy metals in samples (n = 51) by AAS are 17.4 mg/kg for Pb, 5.7 mg/kg for Cd, 8.4 mg/kg for Cr. The mass fraction of an additive as shown by HXRF (n = 161) can vary over a wide range. Precise deductions as regards sWEEE plastics content in hazardous substances and preparations cannot be made. Additional research would be expedient regarding the influence of hazardous substances to recycling processes, in particular regarding the contamination of clean fractions in the exit streams of a WEEE treatment plant. Suitable standards for calibrating HXRF for use on EEE plastics or complex electr(on)ic components do not exist and should be developed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparation and Use of Polish Mushroom Proficiency Testing Materials

Mushroom reference materials have been prepared and characterized for the use in proficiency tests according to a procedure established within the frame of an IAEA Interregional Technical Cooperation Project. The materials were used for conducting the proficiency tests in Poland in 2005-2007. The results obtained by participating laboratories are presented and discussed.

54 ENVIRONMENTAL SCIENCES↗

Implementation of IAEA /1/INT/054 Project in Nuclear Analytical Techniques Group of Argentina: Current State

This paper presents the implementation of the training received through the IAEA Project 'Preparation of Reference Materials and Organization of Proficiency Tests Rounds' in the Nuclear Analytical (NAT) Group of CNEA. Special emphasis is done on those activities related to the first Proficiency Test being carried out by the NAT Group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents--in short--the steps of the experimental tests carried out for INAA method validation and for establishing the 'ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

European Measurement Comparisons of Environmental Radioactivity

The scheme of European measurement comparisons to verify radioactivity monitoring in the European Union is briefly explained. After a review of comparisons conducted during the years 1990, the approach of IRMM organising these comparisons since 2003 is presented. IRMM is providing comparison samples with a reference value traceable to the SI units and which is fully documented to all participants and national authorities after completion of the comparison. The sample preparation and determination of traceable reference values at IRMM, the sample treatment and measurement in the participating laboratories, as well as the evaluation of comparison results are described in some detail using the example of an air filter comparison. The results of a comparison to determine metabolised {sup 40}K, {sup 90}Sr and {sup 137}Cs in milk powder are presented as well. The necessary improvements in the estimation of measurement uncertainty by the participating laboratories are discussed. The performance of individual laboratories which have participated in at least four comparison exercises over the years is studied in terms of observable trends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-shear-rate capillary viscometer for inkjet inks

A capillary viscometer developed to measure the apparent shear viscosity of inkjet inks at high apparent shear rates encountered during inkjet printing is described. By using the Weissenberg-Rabinowitsch equation, true shear viscosity versus true shear rate is obtained. The device is comprised of a constant-flow generator, a static pressure monitoring device, a high precision submillimeter capillary die, and a high stiffness flow path. The system, which is calibrated using standard Newtonian low-viscosity silicone oil, can be easily operated and maintained. Results for measurement of the shear-rate-dependent viscosity of carbon-black pigmented water-based inkjet inks at shear rates up to 2x10{sup 5} s{sup -1} are discussed. The Cross model was found to closely fit the experimental data. Inkjet ink samples with similar low-shear-rate viscosities exhibited significantly different shear viscosities at high shear rates depending on particle loading.

42 ENGINEERING↗

Using Photon Activation Analysis To Determine Concentrations Of Unknown Components In Reference Materials

Using certified multi-element reference materials for instrumental analyses one frequently is confronted with the embarrassing fact that the concentration of some desired elements are not given in the respective certificate, nonetheless are detectable, e.g. by photon activation analysis (PAA). However, these elements might be determinable with sufficient quality of the results using scaling parameters and the well-known quantities of a reference element within the reference material itself. Scaling parameters include: activation threshold energy, Giant Dipole Resonance (GDR) peak and endpoint energy of the bremsstrahlung continuum; integrated photo-nuclear cross sections for the isotopes of the reference element; bremsstrahlung continuum integral; target thickness; photon flux density. Photo-nuclear cross sections from the unreferenced elements must be known, too. With these quantities, the integral was obtained for both the known and unknown elements resulting in an inference of the concentration of the unreported element based upon the reported value, thus also the concentration of the unreferenced element in the reference material. A similar method to determine elements using the basic nuclear and experimental data has been developed for thermal neutron activation analysis some time ago (k{sub 0} Method).

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and magnetic characterization of Sr-based Ni{sub 2}X-type hexaferrite

We have investigated the synthesis conditions, and the magnetic properties of the Sr{sub 2}Ni{sub 2}X-type hexagonal ferrite, Sr{sub 2}Ni{sub 2}Fe{sub 28}O{sub 46}. The Sr{sub 2}Ni{sub 2}X-type hexaferrite was synthesized at 1240{sup ∘}C. The spontaneous magnetization at 5 K was 44.2 μ{sub B}/f.u., suggesting that most of the Ni{sup 2+} ions are at the up-spin octahedral sites in the spinel-structure blocks within the model of a Néel-type collinear ferrimagnetic structure. The Curie temperature of the Sr{sub 2}Ni{sub 2}X-type hexaferrite was estimated to be T{sub C}[Sr{sub 2}Ni{sub 2}X] = 472{sup ∘}C. This is consistent with the difference of the block stacking structures of SrM-type, Sr{sub 2}Ni{sub 2}X-type, SrNi{sub 2}W-type, and nickel spinel ferrites.

36 MATERIALS SCIENCE↗

Use of the Hugoniot Elastic Limit in Laser Shockwave Experiments to Relate Velocity Measurements

---The Idaho National Laboratory (INL) has been developing a Laser Shock system to characterize interface strength in plate fuel for research reactors around the world [1]. This work is in support of the Unites states High Performance Research Reactor program whose goal is to reduce the risk of proliferation of weapons grade fuel while maintaining reactor performance. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. ---One of the concerns of the project is the difficulty of calibrating and standardizing the laser shock technique. The generation of the stress wave by the laser impinging on the plate surface is complex, with amplitude and shape dependence on numerous factors relating to the temporal and spatial distribution of power in the laser spot, surface treatment, and material properties of the plate. Thus the resulting back-face surface velocity, which is used to measure the time-varying stress field within the plate, is difficult to reproduce across different measurement systems. A technique that can generate or indicate a known shock intensity independent of the generating conditions would be valuable and allow us to directly compare results from different systems. ---A Laser Shock round robin test between the system at NRC and the INL was conducted. The goal of the round robin was to determine if there was any bias between the two systems. During the analysis of the data, it was noted that the Hugoniot Elastic Limit (HEL) was consistent within both system data sets independent of the laser power used. An analytical study under development supports that the HEL in metals could be a robust and simple benchmark to compare stresses generated by different laser shock systems. The HEL is a material property that should be insensitive to differences in the shock laser and surface preparation which enhances the reliability of the resulting HEL velocity measurement. 1. J. M. Lacy, J. A. Smith and B. H. Rabin, "Developing a Laser Shockwave Model for Characterizing Diffusion Bonded Interfaces," The 41st Annual Review of Progress in Quantitative Nondestructive Evaluation," Boise, ID, U.S.A., July 2014.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Further Investigation of Surface Velocity Measurements for Material Characterization in Laser Shockwave Experiments

Further investigation of surface velocity measurements for material characterization in laser shockwave experiments James A. Smith, Jeffrey M. Lacy, Clark L. Scott, Bradley C. Benefiel Idaho National Laboratory, Idaho Falls ID Daniel Levesque, Jean-Pierre Monchalin and Martin Lord, National Research Council Canada, Boucherville, QC, Canada ---As part of the US High Performance Research Reactor program, a laser shockwave system is being developed by the Idaho National Laboratory (INL) to characterize interface strength in innovative plate fuel for research reactors around the world. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. One of the concerns is the difficulty of calibrating and standardizing the laser shock technique. The generation of a stress wave by the laser impinging on the plate surface is dependent on the surface preparation, temporal and spatial power distribution of the laser spot, and material properties of the plate. Thus the resulting back surface velocity used to measure the time-varying stress field within the plate is difficult to reproduce across different measurement systems. ---A recent analytical study and testing support the use of the Hugoniot Elastic Limit (HEL) in materials as a robust and simple benchmark to compare stresses generated by different laser shock systems [1]. Using a non-contact laser velocimeter based on a solid Fabry-Perot etalon, the systems at NRC and INL showed that the velocity reached at the HEL is consistent, independent of the laser power used. In this work, the laser velocimeter of the NRC system is tested against a fast rotating wheel to verify accuracy and determine best operating conditions. A round robin test between the two laser shock systems on plates of different Al alloys is presented that shows the correct classification of the Al alloys based on the HEL as well as determining the bias between the systems. Also the effects of some setup parameters on other characteristics of the surface velocity and corresponding stress wave are discussed. 1. J.A. Smith, J.M. Lacy, D. Levesque, J.-P. Monchalin and M. Lord, "Use of the Hugoniot elastic limit in laser shockwave experiments to relate velocity measurements, 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation, AIP Conf. Proc. 1706, pp. 080005-1-080005-10, 2016.

36 MATERIALS SCIENCE↗

Comparing the shock sensitivity of insensitive energetic materials

We present a tabletop method to study the shock sensitivity of plastic-bonded explosives that are considered shock insensitive using high dynamic range optical emission spectroscopy with laser-launched km/s flyer plate impacts (2, 3, and 4 km/s), which measures the spectral radiance (the emission spectrum vs a calibrated intensity standard) every 0.8 ns in the nanosecond and microsecond regimes. The explosives were TATB (1,3,5 trinitro, 2,4,6 triamino benzene), FOX-7 (1,1-diamino-2,2-dinitroethylene), LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide), and NTO (nitrotriazolone), all with 20% Sylgard 182 binder. Time resolving emission from shocked explosives produces a unique fingerprint at each shock pressure, and the emission temporal profile can be used to understand each material's shock response and the underlying mechanisms within the framework of the well-known shock ignition and growth models. Ignition was characterized by the emission intensity during nanosecond hot spot ignition. The growth process, which occurs after the shock has unloaded, was characterized by the time derivative of microsecond emission intensity. Singular-value decomposition was used to determine a characteristic spectral radiance over the entire time range, and this radiance was fit to a graybody model to determine a characteristic temperature Tc. Even though these insensitive explosives have similar shock sensitivities, our method can clearly distinguish their shock response. FOX-7 and NTO were the most sensitive, with FOX-7 having the greatest shock ignition sensitivity, growth rate, and Tc. LLM-105 was much less sensitive than FOX-7 and NTO, and TATB consistently showed the lowest sensitivity by any measure.

Akhtar, Meysam (ORCID:0000000243897837)↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Bayesian Treed Calibration: An Application to Carbon Capture With AX Sorbent

In cases where field or experimental measurements are not available, computer models can model real physical or engineering systems to reproduce their outcomes. They are usually calibrated in light of experimental data to create a better representation of the real system. Statistical methods, based on Gaussian processes, for calibration and prediction have been especially important when the computer models are expensive and experimental data limited. In this paper, we develop the Bayesian treed calibration (BTC) as an extension of standard Gaussian process calibration methods to deal with non-stationarity computer models and/or their discrepancy from the field (or experimental) data. Our proposed method partitions both the calibration and observable input space, based on a binary tree partitioning, into sub-regions where existing model calibration methods can be applied to connect a computer model with the real system. The estimation of the parameters in the proposed model is carried out using Markov chain Monte Carlo (MCMC) computational techniques. Different strategies have been applied to improve mixing. We illustrate our method in two artificial examples and a real application that concerns the capture of carbon dioxide with AX amine based sorbents. The source code and the examples analyzed in this paper are available as part of the supplementary materials.

Bayesian tree↗

Cubic boron nitride as a primary calibrant for a high temperature pressure scale

We present results establishing a new high pressure scale at high temperature based on the thermal equation of state and elastic properties of cubic boron nitride (cBN). This scale is derived from simultaneous measurements of density and sound velocities at high pressure and temperature independent of any previous pressure scale. The present results obtained at room temperature to 27 GPa suggest the validity of the current ruby scale (within {+-}4% at 100 GPa). At high temperature, data obtained at 16 GPa to 723 K are in fair agreement with the thermal equation of state of cBN reported in our previous work. We have also shown that cBN can serve as a convenient pressure gauge in X-ray and optical studies using the laser heated diamond anvil cell.

36 MATERIALS SCIENCE↗