Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPARATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Application of Aura OMI L2G Products Compared with NASA MERRA-2 Assimilation

The Ozone Monitoring Instrument (OMI) is one of the instruments aboard NASA's Aura satellite. It measures ozone total column and vertical profile, aerosols, clouds, and trace gases including NO2, SO2, HCHO, BrO, and OClO using absorption in the ultraviolet electromagnetic spectrum (280 - 400 nm). OMI Level-2G (L2G) products are based on the pixel-level OMI granule satellite measurements stored within global 0.25 deg. X 0.25 deg. grids, therefore they conserve all the Level 2 (L2) spatial and temporal details for 24 hours of scientific data in one file. The second Modern-Era Retrospective analysis for Research and Applications (MERRA-2) is NASA's atmospheric reanalysis, using an upgraded version of Goddard Earth Observing System Model, version 5 (GEOS-5) data assimilation system. MERRA-2 includes aerosol data reanalysis and improved representations of stratospheric ozone, compared with its predecessor MERRA, in both instantaneous and time-averaged collections. It is found that simply comparing satellite Level-3 products might cause biases, due to lack of detailed temporal and original retrieval information. It is therefore preferable to inter-compare or implement satellite derived physical quantities directly with/to model assimilation with as high temporal and spatial resolutions as possible. This study will demonstrate utilization of OMI L2G daily aerosol and ozone products by comparing them with MERRA-2 hourly aerosol/ozone simulations, matched in both space and time aspects. Both OMI and MERRA-2 products are accessible online through NASA Goddard Earth Sciences Data Information Services Center (GES DISC, https://disc.gsfc.nasa.gov/).

OMI L2G products↗

A Comparative Assessment of Evolvable Martian ISRU Propellant Production for Future Human Missions

In 2022, NASA released its “Moon to Mars Strategy and Objectives Development” document, containing top-level goals and objectives designed to create a blueprint for sustained human presence and exploration throughout the solar system. One objective in this “blueprint” calls for the demonstration of “…Mars ISRU capabilities to support an initial human Mars exploration campaign.” NASA is looking at both the benefits and liens of this concept, as one of several trade space aspects under consideration, for inclusion in the overall architecture of the human exploration of Mars. This paper summarizes results from a series of Martian ISRU-focused trade studies from 2023 and 2024. These studies cover five different approaches to providing propellants for returning crew and equipment from the surface of Mars, using several different combinations of propellants delivered (from Earth) and produced from Martian feedstock material. For comparison purposes, the same ISRU infrastructure elements were used across all options wherever possible. The equipment mass, power, operational complexity, and time needed to produce some or all of these propellants have been quantified and compared when used in a common mission scenario. Analysis results for each option are discussed. Performance parameters for these options are compared side-by-side and observations made, including the positive and negative aspects of each case. The possibility of evolving from a simpler ISRU case to more complex cases that would potentially lead to more sustainable operations are also discussed. While no single case emerged as “better” in all aspects when compared to the others, there are distinct advantages and disadvantages that did emerge when comparing the results generated from a common set of assumptions for all cases. Consequently, specific mission objectives may determine which of these advantages or disadvantages are important for choosing among the cases that could benefit any particular mission or campaign.

Mars↗

A Comparative Assessment of Evolvable Martian ISRU Propellant Production for Future Human Missions

In 2022, NASA released its “Moon to Mars Strategy and Objectives Development” document, containing top-level goals and objectives designed to create a blueprint for sustained human presence and exploration throughout the solar system. One objective in this “blueprint” calls for the demonstration of “…Mars ISRU capabilities to support an initial human Mars exploration campaign.” NASA is looking at both the benefits and liens of this concept, as one of several trade space aspects under consideration, for inclusion in the overall architecture of the human exploration of Mars. This paper summarizes results from a series of Martian ISRU-focused trade studies from 2023 and 2024. These studies cover five different approaches to providing propellants for returning crew and equipment from the surface of Mars, using several different combinations of propellants delivered (from Earth) and produced from Martian feedstock material. For comparison purposes, the same ISRU infrastructure elements were used across all options wherever possible. The equipment mass, power, operational complexity, and time needed to produce some or all of these propellants have been quantified and compared when used in a common mission scenario. Analysis results for each option are discussed. Performance parameters for these options are compared side-by-side and observations made, including the positive and negative aspects of each case. The possibility of evolving from a simpler ISRU case to more complex cases that would potentially lead to more sustainable operations are also discussed. While no single case emerged as “better” in all aspects when compared to the others, there are distinct advantages and disadvantages that did emerge when comparing the results generated from a common set of assumptions for all cases. Consequently, specific mission objectives may determine which of these advantages or disadvantages are important for choosing among the cases that could benefit any particular mission or campaign.

Propellant↗

MicrobesOnline: an integrated portal for comparative and functional genomics

Since 2003, MicrobesOnline (http://www.microbesonline.org) has been providing a community resource for comparative and functional genome analysis. The portal includes over 1000 complete genomes of bacteria, archaea and fungi and thousands of expression microarrays from diverse organisms ranging from model organisms such as Escherichia coli and Saccharomyces cerevisiae to environmental microbes such as Desulfovibrio vulgaris and Shewanella oneidensis. To assist in annotating genes and in reconstructing their evolutionary history, MicrobesOnline includes a comparative genome browser based on phylogenetic trees for every gene family as well as a species tree. To identify co-regulated genes, MicrobesOnline can search for genes based on their expression profile, and provides tools for identifying regulatory motifs and seeing if they are conserved. MicrobesOnline also includes fast phylogenetic profile searches, comparative views of metabolic pathways, operon predictions, a workbench for sequence analysis and integration with RegTransBase and other microbial genome resources. The next update of MicrobesOnline will contain significant new functionality, including comparative analysis of metagenomic sequence data. Programmatic access to the database, along with source code and documentation, is available at http://microbesonline.org/programmers.html.

59 BASIC BIOLOGICAL SCIENCES↗

Comparator circuits with local ramp buffering for a column-parallel single slope ADC

A comparator circuit suitable for use in a column-parallel single-slope analog-to-digital converter comprises a comparator, an input voltage sampling switch, a sampling capacitor arranged to store a voltage which varies with an input voltage when the sampling switch is closed, and a local ramp buffer arranged to buffer a global voltage ramp applied at an input. The comparator circuit is arranged such that its output toggles when the buffered global voltage ramp exceeds the stored voltage. Both DC- and AC-coupled comparator embodiments are disclosed.

42 ENGINEERING↗

Mitigating the effects of kickback noise on a comparator

Embodiments herein describe placing a filter network at one of the inputs of the comparator to avoid injecting unequal amounts of kickback noise into the inputs of the comparator. In one embodiment, the filter network matches the impedance seen at the inputs of the comparator. As a result, the amount of kickback noise is essentially equal at the inputs even though the input signals may be at different frequencies. Thus, the kickback noise is essentially cancelled out so that this noise has little to no impact on the output of the comparator.

Hsieh, Kai-An↗

Comparative Study of Enhanced Geothermal System Supply Curves Across CONUS from Two Temperature Models Using the Renewable Energy Potential Model (reV)

Enhanced geothermal systems (EGS) have had recent breakthroughs within the geothermal sector. These breakthroughs are reflected in the National Renewable Energy Laboratory (NREL) 2024 Annual Technology Baseline and will result in updated EGS supply curves (i.e., the available resource capacity relative to cost). Our research uses NREL's Renewable Energy Potential (reV) model to compare EGS supply curves across the conterminous United States (CONUS) for two different temperature models: the Stanford temperature model (STM) and the Southern Methodist University temperature model (SMU). The reV model provides the levelized cost of energy (LCOE) at a consistent resolution across CONUS, taking into consideration transmission costs and constraints as well as technical exclusions pertaining to sensitive cultural, ecological, or infrastructure locations. In addition to a countrywide analysis of both models, we also conducted a regional analysis of Texas. We observed the STM had, on average, lower temperatures across different depths, resulting in slightly higher mean and median LCOEs as compared to the SMU temperature model at the same depths. In the regional analysis for Texas, however, when we compared only the common points between the two temperature models, the STM had lower median and mean LCOEs compared to SMU due to higher temperatures at depths greater than 5 km.

enhanced geothermal systems↗

Comparative study of plutonium burning in heavy and light water reactors.

There is interest in the U.S. and world-wide in reducing the burden on geological nuclear fuel disposal sites. In some disposal scenarios, the decay heat loading of the surrounding rock limits the commercial spent fuel capacity of the sites. In the long term (100 to 1,500 years), this decay heat is generated primarily by actinides, particularly {sup 241}Am and {sup 241}Pu. One possible approach to reducing this decay-heat burden would be to reprocess commercial spent nuclear fuel and use intermediate-tier thermal reactors to 'burn' these actinides and other transuranics (plutonium and higher actinides). The viability of this approach is dependent on the detailed changes in chemical and isotopic compositions of actinide-bearing fuels after irradiation in thermal reactor spectra. The intermediate-tier thermal burners could bridge the commercial water-cooled reactors and fast reactors required for ultimate consumption of the transuranics generated in the commercial reactors. This would reduce the number of such fast reactors required to complete the mission of burning transuranics. If thermal systems are to be used for the transmutation mission, it is likely that they would be similar to or are advanced versions of the systems currently used for power generation. In both the U.S. and Canada, light- and heavy-water-cooled thermal reactors are used for power generation in the commercial nuclear sector. About 103 pressurized- and boiling- light water reactors (PWRs and BRWs) are deployed in the U.S. nuclear industry while about 18 CANDU (heavy-water-cooled) reactors are used in the Canadian industry. There are substantial differences between light and heavy water-cooled reactors that might affect transmutation potential. These arise from differences in neutron balance of the reactors, in neutron energy spectra, in operational approaches (e.g., continuous refueling enhancing fuel burnup), and so on. A systematic study has been conducted to compare the transmutation potentials of CANDU and PWR systems using (U,Pu)O{sub 2} mixed oxide fuels. First, we examine and compare the isotopic evolution of plutonium-containing fuel under irradiation in these reactor types to understand the physics processes involved. The core-physics parameters to be compared for these systems are generated using two-dimensional lattice physics models for a single fuel assembly that is representative of the whole-core (e.g., using the linear reactivity model). Results from a parametric study of the discharge burnup as a function of the Pu fraction in the initial heavy metal are presented for each system. The Pu consumption level, minor actinides buildup level, and the masses destroyed per unit energy generation are summarized and compared. In addition, assessment results for a simple plutonium recycling concept in realistic CANDU and PWR cores are presented. In these cases, plutonium from commercial spent PWR fuel will be separated and burned in realistic intermediate thermal burner reactors using (U,Pu)O{sub 2} mixed oxide fuel. The spent fuel from this thermal burner will be separated and the resulting Pu will be burned in a second pass through the thermal burner reactor. The resulting transuranics are assumed to then be burned in a fast burner reactor. The impact of using the spent fuels of these systems on the core performance of the fast burner reactor and the required numbers of the various reactor types will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MicrobesOnline: an integrated portal for comparative and functional genomics

Since 2003, MicrobesOnline (http://www.microbesonline.org) has been providing a community resource for comparative and functional genome analysis. The portal includes over 1000 complete genomes of bacteria, archaea and fungi and thousands of expression microarrays from diverse organisms ranging from model organisms such as Escherichia coli and Saccharomyces cerevisiae to environmental microbes such as Desulfovibrio vulgaris and Shewanella oneidensis. To assist in annotating genes and in reconstructing their evolutionary history, MicrobesOnline includes a comparative genome browser based on phylogenetic trees for every gene family as well as a species tree. To identify co-regulated genes, MicrobesOnline can search for genes based on their expression profile, and provides tools for identifying regulatory motifs and seeing if they are conserved. MicrobesOnline also includes fast phylogenetic profile searches, comparative views of metabolic pathways, operon predictions, a workbench for sequence analysis and integration with RegTransBase and other microbial genome resources. The next update of MicrobesOnline will contain significant new functionality, including comparative analysis of metagenomic sequence data. Programmatic access to the database, along with source code and documentation, is available at http://microbesonline.org/programmers.html.

10 SYNTHETIC FUELS↗

Comparing Server Energy Use and Efficiency Using Small Sample Sizes

This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a group is similar to all other components as a group. However, some differences were observed. The Supermicro server used 27 percent more power at idle compared to the other brands. The Intel server had a power supply control feature called cold redundancy, and the data suggest that cold redundancy can provide energy savings at low power levels. Test and evaluation methods that might be used by others having limited resources for IT equipment evaluation are explained in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing protein VEGF inhibitors: In vitro biological studies

Highlights: {yields} VEGF is a mediator of angiogenesis. {yields} VEGF inhibitors have clinical applications in cancer and eye disorders. {yields} Five protein VEGF inhibitors were compared for their ability to inhibit. {yields} VEGF-induced activities in cultured endothelial cells. -- Abstract: VEGF inhibitors are widely used as a therapy for tumors and intravascular neovascular disorders, but limited and conflicting data regarding their relative biological potencies are available. The purpose of the study is to compare different protein VEGF inhibitors for their ability to inhibit VEGF-stimulated activities. We tested ranibizumab, the full-length variant of ranibizumab (Mab Y0317), bevacizumab, the VEGF-TrapR1R2 and Flt(1-3)-IgG in bioassays measuring VEGF-stimulated proliferation of bovine retinal microvascular endothelial cells or chemotaxis of human umbilical vein endothelial cells (HUVEC). The inhibitors were also compared for their ability to inhibit MAP kinase activation in HUVECs following VEGF addition. Ranibizumab, VEGF-TrapR1R2 and Flt(1-3)-IgG had very similar potencies in the bioassays tested. Bevacizumab was over 10-fold less potent than these molecules. Mab Y0317 was over 30-fold more potent than bevacizumab. The findings reported in this manuscript describe important intrinsic characteristics of several VEGF inhibitors that may be useful to design and interpret preclinical or clinical studies.

60 APPLIED LIFE SCIENCES↗

High speed rail comparative strategic assessments in EU member states

This paper explores the role and capacity of strategic level assessments in addressing the strategic dimension of High Speed Rail (HSR) proposals and influencing decision-making processes. The overall research objective was to find out to what extent opportunities for strategic thinking are being undertaken in HSR. Three different cases of high speed rail were compared – High Speed Rail 2 (HS2) in the UK, High Speed Rail Network (RFAV) in Portugal and European Gauge Railway Line Kaunas in the Lithuanian-Latvian Border (Rail Baltica 2). Strategic environmental assessment (SEA) effectiveness literature was reviewed to draw on criteria that could establish a comparative framework to explain how environmental and sustainability assessments were undertaken in the three aforementioned European high speed rail case studies. Research results allow us to conclude that an SEA or a sustainability assessment/appraisal (SA) will be most beneficial if developed before any HSR project to first determine if HSR is really necessary and strategically justifiable to the achievement of both environmental and sustainability objectives. Results achieved suggest that even though the SEA and SA in the three cases studied can be said to have influenced the planning process mostly at project-level decisions, it also shows a missed opportunity to contribute to developing a high level strategy for HSR that addresses several strategic issues, assessing options before they are undertaken. - Highlights: •HSR network is strategically relevant for European development. •SEA and SA have been used to support HSR decision-making processes in Europe. •Three HSR SEA/SA cases in Europe (UK, Portugal and Lithuania-Latvia) were reviewed. •Cases were compared in relation to the strategic nature of the assessment. •Conclusions show a missed opportunity to address to a high level strategy for HSR.

54 ENVIRONMENTAL SCIENCES↗

A comparative genome analysis of Cercospora sojina with other members of the pathogen genus Mycosphaerella on different plant hosts

Fungi are the causal agents of many of the world's most serious plant diseases causing disastrous consequences for large-scale agricultural production. Pathogenicity genomic basis is complex in fungi as multicellular eukaryotic pathogens. Here, we report the genome sequence of C. sojina, and comparative genome analysis with plant pathogen members of the genus Mycosphaerella (Zymoseptoria. tritici (synonyms M. graminicola), M. pini, M. populorum and M. fijiensis - pathogens of wheat, pine, poplar and banana, respectively). Synteny or collinearity was limited between genomes of major Mycosphaerella pathogens. Comparative analysis with these related pathogen genomes indicated distinct genome-wide repeat organization features. It suggests repetitive elements might be responsible for considerable evolutionary genomic changes. These results reveal the background of genomic differences and similarities between Dothideomycete species. Wide diversity as well as conservation on genome features forms the potential genomic basis of the pathogen specialization, such as pathogenicity to woody vs. herbaceous hosts. Through comparative genome analysis among five Dothideomycete species, our results have shed light on the genome features of these related fungi species. It provides insight for understanding the genomic basis of fungal pathogenicity and disease resistance in the crop hosts.

54 ENVIRONMENTAL SCIENCES↗

Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality similar to auto-IMRT plans if best effort was spent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential for Improved Intelligence Quotient Using Volumetric Modulated Arc Therapy Compared With Conventional 3-Dimensional Conformal Radiation for Whole-Ventricular Radiation in Children

Purpose: To compare volumetric modulated arc therapy (VMAT) with 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of localized intracranial germinoma. We modeled the effect of the dosimetric differences on intelligence quotient (IQ). Method and Materials: Ten children with intracranial germinomas were used for planning. The prescription doses were 23.4 Gy to the ventricles followed by 21.6 Gy to the tumor located in the pineal region. For each child, a 3D-CRT and full arc VMAT was generated. Coverage of the target was assessed by computing a conformity index and heterogeneity index. We also generated VMAT plans with explicit temporal lobe sparing and with smaller ventricular margin expansions. Mean dose to the temporal lobe was used to estimate IQ 5 years after completion of radiation, using a patient age of 10 years. Results: Compared with the 3D-CRT plan, VMAT improved conformality (conformity index 1.10 vs 1.85), with slightly higher heterogeneity (heterogeneity index 1.09 vs 1.06). The averaged mean doses for left and right temporal lobes were 31.3 and 31.7 Gy, respectively, for VMAT plans and 37.7 and 37.6 Gy for 3D-CRT plans. This difference in mean temporal lobe dose resulted in an estimated IQ difference of 3.1 points at 5 years after radiation therapy. When the temporal lobes were explicitly included in the VMAT optimization, the mean temporal lobe dose was reduced 5.6-5.7 Gy, resulting in an estimated IQ difference of an additional 3 points. Reducing the ventricular margin from 1.5 cm to 0.5 cm decreased mean temporal lobe dose 11.4-13.1 Gy, corresponding to an estimated increase in IQ of 7 points. Conclusion: For treatment of children with intracranial pure germinomas, VMAT compared with 3D-CRT provides increased conformality and reduces doses to normal tissue. This may result in improvements in IQ in these children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Effectiveness of 5 Treatment Strategies for Early-Stage Non-Small Cell Lung Cancer in the Elderly

Purpose: The incidence of early-stage non-small cell lung cancer (NSCLC) among older adults is expected to increase because of demographic trends and computed tomography-based screening; yet, optimal treatment in the elderly remains controversial. Using the Surveillance, Epidemiology, and End Results (SEER)-Medicare cohort spanning 2001-2007, we compared survival outcomes associated with 5 strategies used in contemporary practice: lobectomy, sublobar resection, conventional radiation therapy, stereotactic ablative radiation therapy (SABR), and observation. Methods and Materials: Treatment strategy and covariates were determined in 10,923 patients aged {>=}66 years with stage IA-IB NSCLC. Cox regression, adjusted for patient and tumor factors, compared overall and disease-specific survival for the 5 strategies. In a second exploratory analysis, propensity-score matching was used for comparison of SABR with other options. Results: The median age was 75 years, and 29% had moderate to severe comorbidities. Treatment distribution was lobectomy (59%), sublobar resection (11.7%), conventional radiation (14.8%), observation (12.6%), and SABR (1.1%). In Cox regression analysis with a median follow-up time of 3.2 years, SABR was associated with the lowest risk of death within 6 months of diagnosis (hazard ratio [HR] 0.48; 95% confidence interval [CI] 0.38-0.63; referent is lobectomy). After 6 months, lobectomy was associated with the best overall and disease-specific survival. In the propensity-score matched analysis, survival after SABR was similar to that after lobectomy (HR 0.71; 95% CI 0.45-1.12; referent is SABR). Conventional radiation and observation were associated with poor outcomes in all analyses. Conclusions: In this population-based experience, lobectomy was associated with the best long-term outcomes in fit elderly patients with early-stage NSCLC. Exploratory analysis of SABR early adopters suggests efficacy comparable with that of surgery in select populations. Evaluation of these therapies in randomized trials is urgently needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗