Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Longitudinal Impedance of Inductive Inserts

In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.

43 PARTICLE ACCELERATORS↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

PMU-Based Decoupled State Estimation for Unsymmetrical Power Systems

Modal decomposition of measurement equations has already been shown to simplify the formulation and resulting computational complexity of three-phase state estimation of systems where all the transmission lines are three-phase and fully transposed. When there are non-transposed and/or mixed-phase lines, modal decomposition can no longer fully decouple the threephase measurement equations. Here, this paper addresses the above shortcoming by proposing a simple yet practical solution based on the commonly used numerical compensation techniques. Thus, it enables application of the powerful decoupling approach to any type of three-phase networks which may contain non-transposed or mixed-phase lines and are fully observable by PMUs. The proposed procedure modifies the measurement set by deriving additive terms that compensate for the neglected unsymmetrical effects. It will be shown that unbalanced systems including nontransposed and mixed-phase elements, can still be transformed into three decoupled subsystems and solved in parallel by the proposed approach. Performance of the proposed algorithm is validated against several IEEE test cases.

42 ENGINEERING↗

Log-N/Period Sensitivity Analysis

The Log-N/Period system utilizes a compensated ion chamber to measure neutron radiation in the reactor core. This analysis focuses on determining a more accurate value for the sensitivity of the installed compensated ion chambers for the Log-N/Period system at the ATR. Using calibration procedures a formula for indirectly calculating the sensitivity of the chambers was derived. Using historical data from approximately ten reactor cycles a new average sensitivity for both channels of the Log-N/Period system was determined.

42 ENGINEERING↗

Research Progress and Perspectives on Pre‐Sodiation Strategies for Sodium‐Ion Batteries

Sodium‐ion batteries (SIBs) with abundant elements have garnered significant attention from researches as a promise compensation to lithium‐ion batteries (LIBs). However, the large‐scale commercial application of SIBs is partially hindered by the limited initial coulombic efficiency (ICE) due to the irreversible formation of solid electrolyte interphase (SEI) and intercalation into the defects in the anode. Similar to pre‐lithiation techniques, pre‐sodiation approaches are considered to be one of the most direct and effective way to compensate for the loss of active sodium at the anode side of SIBs during the initial cycle. In this context, additional sodium ions are pre‐injected to the cathode/anode material by chemical/electrochemical methods, aiming to improve battery span life and energy density. Here, this review delves into the necessity and impact of pre‐sodiation techniques, compiling the latest research progress, for instance, self‐sacrificing cathode additives, over‐sodiated cathode materials, direct contact and solution chemical pre‐sodiation. Notably, the research mechanisms underlying solution chemical pre‐sodiation are highlighted. This comprehensive overview aims to foster a deeper understanding of the pre‐sodiation techniques and expects to provide guidance for realizing the commercial application of high energy density sodium‐ion batteries.

25 ENERGY STORAGE↗

Electrochemical Doping of Halide Perovskites by Noble Metal Interstitial Cations

Abstract Metal halide perovskites are an attractive class of semiconductors, but it has proven difficult to control their electronic doping by conventional strategies due to screening and compensation by mobile ions or ionic defects. Noble‐metal interstitials represent an under‐studied class of extrinsic defects that plausibly influence many perovskite‐based devices. In this work, doping of metal halide perovskites is studied by electrochemically formed Au + interstitial ions, combining experimental data on devices with a computational analysis of Au + interstitial defects based on density functional theory (DFT). Analysis suggests that Au + cations can be easily formed and migrate through the perovskite bulk via the same sites as iodine interstitials (I i + ). However, whereas I i + compensates n‐type doping by electron capture, the noble‐metal interstitials act as quasi‐stable n‐dopants. Experimentally, voltage‐dependent, dynamic doping by current density–time ( J–t ), electrochemical impedance, and photoluminescence measurements are characterized. These results provide deeper insight into the potential beneficial and detrimental impacts of metal electrode reactions on long‐term performance of perovskite photovoltaic and light‐emitting diodes, as well as offer an alternative doping explanation for the valence switching mechanism of halide‐perovskite‐based neuromorphic and memristive devices.

14 SOLAR ENERGY↗

Beryllium disease among construction trade workers at Department of Energy nuclear sites: A follow‐up

Abstract Background Construction workers at U.S. Department of Energy (DOE) nuclear weapons facilities are screened to identify DOE‐related occupational illnesses, including beryllium sensitization (BeS) and chronic beryllium disease (CBD). The study objectives were to estimate beryllium disease risks and the CBD claims acceptance rate in the energy workers' benefits program. Methods Workers diagnosed with BeS via beryllium lymphocyte proliferation test (BeLPT) included in screening examinations were interviewed about subsequent diagnosis of CBD. We estimated the proportion who developed CBD based on the ratio of CBD cases, based on self‐reported compensation claim status, to all workers with BeS interviewed. We used stratified analyses to explore trends in disease frequency by age, race, sex, DOE employment duration, site, trade group, and cigarette smoking history. Results Between 1998 and 2020, 21,854 workers received a BeLPT; 262 (1.20%) had BeS (two abnormals or one abnormal plus one borderline test); 212 (0.97%) had a single abnormal BeLPT. Of 177 BeS workers interviewed, 35 (19.8%) reported an accepted CBD compensation claim. The claims acceptance rate among BeS workers increased with years of DOE employment, from 8.4% with <5 years to 33.3% for >25 or more years. Five of 68 interviewed workers with a single positive BeLPT reported CBD claim acceptance; an additional CBD case was confirmed by chart review (8.8%). Conclusions Years of DOE work predict the risk of developing CBD among those sensitized and getting a claim for CBD accepted. Ongoing surveillance and increased awareness of the risk of beryllium exposure and CBD as an occupational disease among construction workers are needed.

Cloeren, Marianne↗

Suppressing Carbon Incorporation in Metal–Organic Chemical Vapor Deposition GaN Using High‐Offcut‐Angled Substrates

Carbon (C) is a common impurity that acts as a compensator within GaN grown via metal–organic chemical vapor deposition (MOCVD). Reducing C in GaN will help reduce the compensation level and provide a route to achieve GaN with reliably low effective doping for high-power device applications. GaN grown with fast growth rates on bulk GaN with various offcut angles via conventional-MOCVD (C-MOCVD) and laser-assisted MOCVD (LA-MOCVD) is compared and analyzed. C-incorporation effects are compared through quantitative secondary-ion mass spectroscopy analysis in GaN grown on GaN substrate with offcut angles of 4° and 0.3° toward m-plane over a wide range of growth rates by C-MOCVD and LA-MOCVD. For both growth techniques investigated, a significant reduction in C-incorporation is observed when a high-offcut-angle (4°) substrate is used as compared to a lower-offcut-angle (0.3°) substrate. Furthermore, with C-MOCVD, at the fastest growth condition investigated (17.26 μm h −1 at 0.3°-offcut, 15.25 μm h −1 at 4°-offcut), a reduction in [C] by 21.2X is observed with an increase in the offcut angle from 0.3° to 4°. A 82.6X reduction in [C] is observed with the similar fast growth condition via LA-MOCVD on GaN with 4° offcut angle (9.78 μm h −1 ) as compared to C-MOCVD at 0.3° offcut angle (17.26 μm h −1 ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An independent analysis of bias sources and variability in wind plant pre-construction energy yield estimation methods

The wind resource assessment community has long had the goal of reducing the bias between wind plant pre-construction energy yield assessment (EYA) and the observed annual energy production (AEP). This comparison is typically made between the 50% probability of exceedance (P50) value of the EYA and the long-term corrected operational AEP (hereafter OA P50), and is known as the P50 bias. The industry has critically lacked an independent analysis of bias reduction investigated across multiple consultants to identify the greatest sources of uncertainty and variance in the EYA process and the best opportunities for uncertainty reduction. The present study addresses this gap by benchmarking consultant methodologies against each other and against operational data at a scale not seen before in industry collaborations. We consider data from 10 wind plants and evaluate discrepancies between eight consultancies in the steps taken from estimates of gross to net energy. Consultants tend to overestimate the gross energy produced at the turbines and then compensate by further overestimating downstream losses, leading to a mean P50 bias near zero, still with significant variability among the individual wind plants. Within our data sample, we find that consultant estimates of all loss categories, except environmental losses, tend to reduce the project-to-project variability of the P50 bias. The disagreement between consultants, however, remains flat throughout the addition of losses. Finally, we find that differences in consultants’ estimates of project performance can lead to differences up to $10/MWh in the levelized cost of energy for a wind plant.

Todd, Austin C.↗

Preliminary design of control rods in the single-fluid double-zone thorium molten salt reactor (SD-TMSR)

Recent studies on Molten Salt Reactors (MSRs) showed that the excess reactivity at the beginning of the operation is large for many fueling strategies and must be compensated by a reactivity control system. The current work introduces a reliable safety system based on control rods in addition to the online feed system reactivity control in the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR). Three different initial fissile loadings are considered: 233 U, reactor-grade Pu, and transuranic (TRU) elements as a startup fuel. We applied six different absorbing materials to investigate the main operational and safety parameters in the SD-TMSR: natural B 4 C, enriched B 4 C with 90% 10 B, HfB 2 , HfH 1.62 , Eu 2 O 3 , and Gd 2 O 3 . The present work focuses on control rod design, integral and differential control rod worth, shutdown margin, and shadowing effects at steady-state. We employed the SERPENT-2 Monte-Carlo code to calculate the reactivity worth and analyze the performance of the reactivity control system. We showed that 233 U and reactor-grade Pu startup cores maintain adequate shutdown margin with all considered absorbers. Finally, this report proposes a design of control rod clusters that compensate the excess reactivity of the SD-TMSR loaded with different initial fissile material.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ab initio molecular dynamics simulation of Nd3+ incorporation in calcite

Trivalent rare-earth elements (REEs) readily incorporate in Ca-bearing minerals such as calcite (CaCO3), a phenomenon with important implications for the use of REEs as biogeochemical tracers as well as for environmental remediation. Despite substantial efforts, determining the incorporation modes of trivalent REEs in calcite has remained challenging due to their presence in multiple coordination environments. This is particularly problematic for the interpretation of extended X-ray absorption fine structure (EXAFS) spectroscopy. In this work, ab initio molecular dynamics (AIMD) simulations of Nd3+ incorporated in calcite were performed to resolve its incorporation modes. Nd3+ and Ca2+ have very similar ionic radii but the additional positive charge requires a charge compensation scheme (CCS). Five CCSs were considered in AIMD simulations, and the resulting atomic trajectories were then used to compute EXAFS spectra for direct fitting to a published experimental spectrum. The results of the fits indicated that Nd3+ incorporates at the Ca2+ site in calcite in a mixture of six- and seven-fold coordination environments and through three main incorporation modes: associated with a protonated nearest-neighbor Ca2+ vacancy, incorporated as NdOH2+, and charge compensated by a remote species (on the spatial scale probed by EXAFS). The incorporation of Nd3+ in calcite via multiple modes was consistent with previous work, but the AIMD-EXAFS approach allowed for resolving the nature, proportion, and structure of the different coordination environments.

Kerisit, Sebastien N.↗

Leveraging concentrating solar power plant dispatchability: A review of the impacts of global market structures and policy

Concentrating solar power (CSP) integrated with thermal energy storage delivers flexible and dispatchable power, which is an increasingly valuable quality as electricity systems integrate growing penetrations of variable renewable energy. Valuing and compensating CSP's dispatchability and flexibility requires electricity market structures and policies that appropriately remunerate generation during high-value portions of the day. In this paper, we review previous analyses of CSP economics and deployment, and we find that continued CSP growth will require valuation mechanisms that appropriately compensate for CSP's flexibility during both plant design and plant operation. We then review market structures that drive CSP operations and dispatch in jurisdictions where CSP is being developed, with perspectives from Spain, Chile, Australia, Morocco, South Africa, the United States, China, and the United Arab Emirates (Dubai). Despite broad agreement that CSP's dispatchability provides value to electricity grids, countries' policies for remunerating and leveraging such dispatchability varies widely. As deployment of CSP and variable renewable energy grows, it will be increasingly important to redesign current integration policies to signal the delivery of CSP's grid services more appropriately.

14 SOLAR ENERGY↗

Direct regeneration of degraded LiFePO4 cathodes via a separator-enabled prelithiation strategy

A persistent challenge in lithium-ion batteries is the loss of active lithium due to the solid electrolyte interphase (SEI) formation and associated side reactions. While prelithiation employing lithium replenishment separator (LRS) has been proven effective in compensating for lithium loss, previous studies have largely been accompanied by gas evolution or solid residue formation during the prelithiation process. To surmount this challenge, we present a LRS based on 4-fluoro-1,2-dihydroxybenzene lithium salt (LiDF), capable of mitigating lithium loss while producing decomposition products that integrate directly into the electrolyte as functional additives which can assist with the stability of the SEI, free from gas or solid formation, thus establishing a sustainable and environmentally benign strategy for lithium compensation. Incorporation of the LRS enables the pristine LiFePO4||graphite (Gr) full cell to achieve 10.8% higher capacity than the cell with a polypropylene separator (PPS) after 200 cycles at 0.5C. Remarkably, the degraded LiFePO4 (D-LFP)||Gr full cell with the LRS exhibits a 135.8% capacity improvement over the PPS-based cell after 500 cycles. These findings establish the LRS as a powerful approach for both boosting high-performance lithium-ion batteries and recovering the capacity of degraded batteries.

Tao, Fujun↗

From MAST-U to STEP: Power exhaust control challenges and opportunities

This work explores the challenges and opportunities for power exhaust control in STEP, informed by dedicated MAST-U experiments. The STEP system primarily relies on hydrogenic and argon gas injection into the divertors, compensating for transients originating in the plasma core. Fast transients (>10 Hz) that evolve too quickly for actuators to compensate must be absorbed passively; the enhanced transient buffering of the foreseen long-legged divertor provides a clear advantage over conventional geometries, as demonstrated in the MAST-U Super-X divertor. Experiments further indicate that STEP’s tight divertor baffling enables near-independent control of the upper and lower divertors. The most challenging transients are expected from power-sharing fluctuations, as MAST-U experiments observed extremely fast dynamics. Fluctuations from core pellet fuelling remain relatively benign due to the small pellet size according to simulations. Exhaust control in a reactor like STEP requires an integrated approach befitting its machine-critical nature. A predictive control element, integrated with core plasma control, allows pre-emptive preparation of the divertor for incoming transients. An observer-based diagnostic approach is foreseen to monitor the divertor in the challenging reactor environment, supported by an extended diagnostic set in the non-nuclear phase to validate the required dynamic models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Effect of Dopant Concentration and Annealing Treatments on N-Type Iodine Doped CdTe

We report properties of highly conducting n-type cadmium telluride single crystals doped with iodine (CdTe:I). These crystals were grown with dopant concentrations in the range of 10^17 cm-3 to 10^19 cm-3 by Modified Vertical Bridgman (MVB) melt growth. Post-growth dopant activation, including Cd annealing, Te annealing, and rapid thermal annealing (RTA), was applied to improve free carrier density. The structural, optical, and electrical properties were analyzed by Glow Discharge Mass Spectroscopy (GDMS), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), Photoluminescence Spectroscopy (PL), optical absorption, Hall measurements, Capacitance-Voltage (CV) measurements, and time-resolved photoluminescence (TRPL). The results indicate that Cd annealing is the most effective activation method to get 100% donor activation (n is approximately 2 x 10^18 cm-3), which is close to the room temperature solubility limit of iodine. This leads to the lowest resistivity and the highest mobility. Moreover, this data suggests a potential role of Cd vacancy-related defects on electrical self-compensation.

annealing↗

Pentaerythritol structure-directing agents bias aluminum siting in MFI zeolites to increase para -xylene selectivity during toluene methylation

MFI zeolites contain ten-membered ring channels (∼0.55 nm diameter) that intersect to form larger voids (∼0.70 nm diameter). The distribution of framework Al sites dictates the void environments that confine active H + sites. MFI synthesized with pentaerythritol (PET) and Na + as structure-directing agents are interrogated using kinetically controlled toluene methylation rates and xylene isomer selectivities. High para-xylene selectivity and low toluene methylation rates indicate that MFI-PET samples contain H + sites predominantly in smaller channels. As-synthesized samples contain more framework Al than Na + , indicating that some charge compensation is provided by protonated PET-solvent complexes that bias Al siting towards these smaller channels.