Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Definitive Chemoradiation Therapy Following Surgical Resection or Radiosurgery Plus Whole-Brain Radiation Therapy in Non-Small Cell Lung Cancer Patients With Synchronous Solitary Brain Metastasis: A Curative Approach

Purpose/Objectives: The aim of this study was to evaluate the impact of definitive thoracic chemoradiation therapy following surgery or stereotactic radiosurgery (SRS) and whole-brain radiation therapy (WBRT) on the outcomes of patients with non-small cell lung cancer (NSCLC) with synchronous solitary brain metastasis (SSBM). Methods and Materials: A total of 63 NSCLC patients with SSBM were retrospectively evaluated. Patients were staged using positron emission tomography-computed tomography in addition to conventional staging tools. Thoracic radiation therapy (TRT) with a total dose of 66 Gy in 2 Gy fractions was delivered along with 2 cycles of cisplatin-based chemotherapy following either surgery plus 30 Gy of WBRT (n=33) or SRS plus 30 Gy of WBRT (n=30) for BM. Results: Overall, the treatment was well tolerated. All patients received planned TRT, and 57 patients (90.5%) were also able to receive 2 cycles of chemotherapy. At a median follow-up of 25.3 months (7.1-52.1 months), the median months of overall, locoregional progression-free, neurological progression-free, and progression-free survival were 28.6, 17.7, 26.4, and 14.6, respectively. Both univariate and multivariate analyses revealed that patients with a T1-T2 thoracic disease burden (P=.001), a nodal stage of N0-N1 (P=.003), and no weight loss (P=.008) exhibited superior survival. Conclusions: In the present series, surgical and radiosurgical treatments directed toward SSBM in NSCLC patients were equally effective. The similarities between the present survival outcomes and those reported in other studies for locally advanced NSCLC patients indicate the potentially curative role of definitive chemoradiation therapy for highly selected patients with SSBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A feasibility study: Selection of a personalized radiotherapy fractionation schedule using spatiotemporal optimization

Purpose: To investigate the impact of using spatiotemporal optimization, i.e., intensity-modulated spatial optimization followed by fractionation schedule optimization, to select the patient-specific fractionation schedule that maximizes the tumor biologically equivalent dose (BED) under dose constraints for multiple organs-at-risk (OARs). Methods: Spatiotemporal optimization was applied to a variety of lung tumors in a phantom geometry using a range of tumor sizes and locations. The optimal fractionation schedule for a patient using the linear-quadratic cell survival model depends on the tumor and OAR sensitivity to fraction size (α/β), the effective tumor doubling time (T{sub d}), and the size and location of tumor target relative to one or more OARs (dose distribution). The authors used a spatiotemporal optimization method to identify the optimal number of fractions N that maximizes the 3D tumor BED distribution for 16 lung phantom cases. The selection of the optimal fractionation schedule used equivalent (30-fraction) OAR constraints for the heart (D{sub mean} ≤ 45 Gy), lungs (D{sub mean} ≤ 20 Gy), cord (D{sub max} ≤ 45 Gy), esophagus (D{sub max} ≤ 63 Gy), and unspecified tissues (D{sub 05} ≤ 60 Gy). To assess plan quality, the authors compared the minimum, mean, maximum, and D{sub 95} of tumor BED, as well as the equivalent uniform dose (EUD) for optimized plans to conventional intensity-modulated radiation therapy plans prescribing 60 Gy in 30 fractions. A sensitivity analysis was performed to assess the effects of T{sub d} (3–100 days), tumor lag-time (T{sub k} = 0–10 days), and the size of tumors on optimal fractionation schedule. Results: Using an α/β ratio of 10 Gy, the average values of tumor max, min, mean BED, and D{sub 95} were up to 19%, 21%, 20%, and 19% larger than those from conventional prescription, depending on T{sub d} and T{sub k} used. Tumor EUD was up to 17% larger than the conventional prescription. For fast proliferating tumors with T{sub d} less than 10 days, there was no significant increase in tumor BED but the treatment course could be shortened without a loss in tumor BED. The improvement in the tumor mean BED was more pronounced with smaller tumors (p-value = 0.08). Conclusions: Spatiotemporal optimization of patient plans has the potential to significantly improve local tumor control (larger BED/EUD) of patients with a favorable geometry, such as smaller tumors with larger distances between the tumor target and nearby OAR. In patients with a less favorable geometry and for fast growing tumors, plans optimized using spatiotemporal optimization and conventional (spatial-only) optimization are equivalent (negligible differences in tumor BED/EUD). However, spatiotemporal optimization yields shorter treatment courses than conventional spatial-only optimization. Personalized, spatiotemporal optimization of treatment schedules can increase patient convenience and help with the efficient allocation of clinical resources. Spatiotemporal optimization can also help identify a subset of patients that might benefit from nonconventional (large dose per fraction) treatments that are ineligible for the current practice of stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

The high-efficiency jets magnetically accelerated from a thin disk in powerful lobe-dominated FRII radio galaxies

A maximum jet efficiency line R ∼ 25 (R = L {sub jet}/L {sub bol}), found in FRII radio galaxies by Fernandes et al., was extended to cover the full range of jet power by Punsly. Recent general relativistic magnetohydrodynamic simulations of jet formation have mainly focused on the enhancement of jet power. In this work, we suggest that the jet efficiency could be very high even for conventional jet power if the radiative efficiency of disks was much smaller. We adopt the model of a thin disk with magnetically driven winds to investigate the observational high-efficiency jets in FRII radio galaxies. It is found that the structure of a thin disk can be significantly altered by the feedback of winds. The temperature of a disk gradually decreases with increasing magnetic field; the disk density, surface density, and pressure also change enormously. The lower temperature and higher surface density in the inner disk result in the rapid decrease of radiative efficiency. Thus, the jet efficiency is greatly improved even if the jet power is conventional. Our results can explain the observations quite well. The theoretical maximum jet efficiency of R ∼ 1000 suggested by our calculations is large enough to explain all of the high jet efficiency in observations, even considering the episodic activity of jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

A portable X-pinch design for x-ray diagnostics of warm dense matter

We describe the design and x-ray emission properties (temporal, spatial, and spectral) of Dry Pinch I, a portable X-pinch driver developed at Imperial College London. Dry Pinch I is a direct capacitor discharge device, 300 × 300 × 700 mm3 in size and ∼50 kg in mass, that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments. Among key findings, the device is shown to reliably produce 1.1 ± 0.3 ns long x-ray bursts that couple ∼50 mJ of energy into photon energies from 1 to 10 keV. The average shot-to-shot jitter of these bursts is found to be 10 ± 4.6 ns using a combination of x-ray and current diagnostics. The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches—suggesting a spot size of 10 ± 6 µm in the soft energy region (1–10 keV) and 190 ± 100 µm in the hard energy region (>10 keV). These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available. At the same time, this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.

47 OTHER INSTRUMENTATION↗

The effect of neutron irradiation on conventional and nanocrystalline nickel: NSUF Work Package UA-22PN080501 Milestone M3UA-22PN0805012 (Final Report)

Even though nanocrystalline materials (20-100 nm) present an unprecedented potential, scientific knowledge related to the effect of neutron irradiation on the mechanical properties and microstructure is still scarce. Most of the past studies were conducted using ion irradiation which may not have the same effect as neutron irradiation because of the smaller irradiation volume and the higher dose rate. To reach a firm conclusion on the potential of nanocrystalline materials for nuclear reactor applications, extensive study of model metals with different stacking fault energy (SFE) is required to elucidate their behavior in radiation environments. Nanocrystalline copper and nickel are typically chosen because they are commonly used as model FCC metals in studies of radiation effects. Nickel is an FCC metal with a high stacking-fault energy (~125 mJ/m 2 ) compared to copper (~45 mJ/m 2 ). Hence, microcrystalline and nanocrystalline nickel samples were irradiated in the INL’s Advanced Test Reactor (ATR), as a part of FY08 North Carolina State University NSUF Irradiation Experiment# 96 to evaluate the irradiation behavior of these materials. The objective of this FY20 NSUF project# 19122 is to perform PIE (at PNNL NSUF facility) on previously ATR-neutron irradiated (1.2 and 2.6 dpa; 80-89°C) nanocrystalline and microcrystalline nickel samples to investigate the changes in mechanical properties and microstructures and evaluate whether nanocrystalline nickel is relatively more radiation resistant compared to conventional microcrystalline nickel. To perform PIE at PNNL, sixteen neutron irradiated specimens (microcrystalline and nanocrystalline) were transferred from the NSUF Nuclear Fuels and Materials Library at INL. Experimental techniques such as SEM/EBSD, XRD, TEM, Vickers microhardness and tensile testing were employed to characterize the effect of neutron irradiation on the microstructure and mechanical properties of nanocrystalline nickel and compared them with corresponding characteristics of microcrystalline nickel.

36 MATERIALS SCIENCE↗

Radiation dosimetry and biophysical models of space radiation effects

Estimating the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons, and the absence of epidemiology data for these radiation types. Developing useful biophysical parameters or models that relate energy deposition by space particles to the probabilities of biological outcomes is a complex problem. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra. In contrast to conventional dosimetric methods, models of radiation track structure provide descriptions of energy deposition events in biomolecules, cells, or tissues, which can be used to develop biophysical models of radiation risks. In this paper, we address the biophysical description of heavy particle tracks in the context of the interpretation of both space radiation dosimetry and radiobiology data, which may provide insights into new approaches to these problems.

Review↗

Multi-MGy Radiation Hardened Camera for Nuclear Facilities

There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera electronics will be exposed. Another important element of the camera is the optical system that transports the image from the scene to the image sensor. This arrangement of glass-based lenses is affected by radiations through two mechanisms: the radiation induced absorption and the radiation induced refractive index changes. The first one will limit the signal to noise ratio of the image whereas the second one will directly affect the resolution of the camera. We'll present at the conference a coupled simulation/experiment study of these effects for various commercial glasses and present vulnerability study of typical optical systems to radiations at MGy doses. The last very important part of the camera is the illumination system that can be based on various technologies of emitting devices like LED, SLED or lasers. The most promising solutions for high radiation doses will be presented at the conference. In addition to this hardening-by-component approach, the global radiation tolerance of the camera can be drastically improve by working at the system level, combining innovative approaches eg. for the optical and illumination systems. We'll present at the conference the developed approach allowing to extend the camera lifetime up to the MGy dose range. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Postoperative Stereotactic Body Radiation Therapy (SBRT) for Spine Metastases: A Critical Review to Guide Practice

Postoperative stereotactic body radiation therapy (SBRT) for metastatic spinal tumors is increasingly being performed in clinical practice. Whereas the fundamentals of SBRT practice for intact spinal metastases are established, there are as yet no comprehensive practice guidelines for the postoperative indications. In particular, there are unique considerations for patient selection and treatment planning specific to postoperative spine SBRT that are critical for safe and effective management. The purpose of this critical review is to discuss the rationale for treatment, describe those factors affecting surgical decision making, introduce modern surgical trends, and summarize treatment outcomes for both conventional postoperative external beam radiation therapy and postoperative spine SBRT. Lastly, an in-depth practical discussion with respect to treatment planning and delivery considerations is provided to help guide optimal practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural stability and mechanical behavior of FeNiMnCr high entropy alloy under ion irradiation

In recent years, high entropy alloys (HEAs) have attracted significant attention due to their excellent mechanical properties and good corrosion resistance, making them potential candidates for high temperature fission and fusion structural applications. However there is very little known about their radiation resistance, particularly at elevated temperatures relevant for energy applications. In the present study, a single phase (face centered cubic) concentrated solid solution alloy of composition 27%Fe-28%Ni-27%Mn-18%Cr was irradiated with 3 or 5.8 MeV Ni ions at temperatures ranging from room temperature to 700 °C and midrange doses from 0.03 to 10 displacements per atom (dpa). Transmission electron microscopy (TEM), scanning transmission electron microscopy with energy dispersive x-ray spectrometry (STEM/EDS) and X-ray diffraction (XRD) were used to characterize the radiation defects and microstructural changes. Irradiation at higher temperatures showed evidence of relatively sluggish solute diffusion with limited solute depletion or enrichment at grain boundaries. The main microstructural feature at all temperatures was high-density small dislocation loops. Voids were not observed at any irradiation condition. Nano-indentation tests on specimens irradiated at room temperature showed a rapid increase in hardness ~35% and ~80% higher than the unirradiated value at 0.03 and 0.3 dpa midrange doses, respectively. The irradiation-induced hardening was less pronounced for 500 °C irradiations (<20% increase after 3 dpa). Overall, the examined HEA material exhibits superior radiation resistance compared to conventional single phase Fe-Cr-Ni austenitic alloys such as stainless steels. Furthermore, the present study provides insight on the fundamental irradiation behavior of a single phase HEA material over a broad range of irradiation temperatures.

36 MATERIALS SCIENCE↗

Effects of turbulence-radiation coupling in pressurized oxy-combustion

Concerns over climate change have led to numerous efforts in developing low-carbon energy technologies. Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emission in power generation. Due to the strong impact of pressure on thermal radiation, heat transfer in POC differs significantly from the situation of conventional atmospheric pressure combustion. Thus thermal radiation in POC needs to be investigated to aid new combustor development. The present computational work is a step in this direction, initiating a systematic analysis of thermal radiation and heat transfer in a pilot-scale POC combustor, which has been developed at Washington University in St. Louis (WUSTL). In a POC process, pulverized coal is burned under elevated pressure and O2-CO2 environment. While most previous computational works on flame radiation focused on atmospheric pressure condition, this work considered a pressurized flame. Specifically, a 15-bar POC combustor of power 50 kW is modeled employing the Ansys FLUENT commercial platform, using both Reynolds-averaged Navier-Stokes (RANS) modeling and large-eddy simulation (LES). A recently published and validated global radiation model is used to predict the radiative property of the flue gas. The discrete ordinates (DO) radiation model is chosen to solve the radiative transport equation. Incident radiation on the walls of the combustor is identified and investigated. It is revealed that for this pilot-scale, pressurized combustor, thermal radiation exhibits similar patterns in the RANS and LES models. However, the magnitudes of radiation are different in both models, presumably because interactions between radiation and turbulence are embedded in the LES model but not in the RANS model. This difference thereby underlines the major goal of this research: investigating the impact of such turbulence-to-radiation coupling on thermal radiation in a pilot-scale POC setting. Most previous studies on turbulence-to-radiation interactions focused on bench-scale, atmospheric pressure flames. This work is the first effort to extend this study to a pilot-scale, pressurized flame.

Li, Lei↗

13 C Radiofrequency Amplification by Stimulated Emission of Radiation Threshold Sensing of Chemical Reactions

Conventional nuclear magnetic resonance (NMR) enables detection of chemicals and their transformations by exciting nuclear spin ensembles with a radio-frequency pulse followed by detection of the precessing spins at their characteristic frequencies. The detected frequencies report on chemical reactions in real time and the signal amplitudes scale with concentrations of products and reactants. Here, we employ Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), a quantum phenomenon producing coherent emission of 13 C signals, to detect chemical transformations. The 13 C signals are emitted by the negatively hyperpolarized biomolecules without external radio frequency pulses and without any background signal from other, nonhyperpolarized spins in the ensemble. Here, we studied the hydrolysis of hyperpolarized ethyl-[1- 13 C]acetate to hyperpolarized [1- 13 C]acetate, which was analyzed as a model system by conventional NMR and 13 C RASER. The chemical transformation of 13 C RASER-active species leads to complete and abrupt disappearance of reactant signals and delayed, abrupt reappearance of a frequency-shifted RASER signal without destroying 13 C polarization. Further, the experimentally observed “quantum” RASER threshold is supported by simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidation of the chemical environment for zinc species in an electron-rich zinc-incorporated zeolite

An electron-rich zinc-modified zeolite has been prepared by the incorporation of zinc vapor into the channels of a dehydrated HY (protonated zeolite Y). The chemical environment of the zinc species in the electron-rich zeolite has been elucidated on the basis of X-ray absorption spectroscopy. The formation of univalent zinc (Zn{sup +}) within the electron-rich zeolite was observed upon the irradiation of X-ray from either a synchrotron radiation source or a conventional X-ray diffractometer. The X-ray irradiation initiated the electron transfer from the electron-rich framework of zeolite Y to the nearby Zn{sup 2+} cations, generating Zn{sup +} species. The variation of the coordination environment of the zinc species upon interaction with water molecules has also been investigated. - Graphical abstract: The chemical environment of the zinc species in an electorn-rich zeolite has been elucidated on the basis of X-ray absorption spectroscopy. - Highlights: • An electron-rich zinc-incorporated zeolite has been prepared by chemical vapor reaction. • Univalent zinc is detected after the electron-rich zeolite is irradiated with X-ray. • The chemical environment of the zinc species is elucidated by X-ray absorption spectroscopy. • The coordination environment of the zinc species changes upon interaction with water molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strategies for SEE Hardness Assurance - From Buy-It-And-Fly-It to Bullet Proof

This part of the course first outlines the conventional Single Event Effect (SEE), radiation hardness assurance (RHA) approach, which emphasizes mission success. Next, Dr. Ladbury will discuss the challenges posed by new satellite platforms (e.g., cubesats, nanosats, etc.), where cost and schedule receive emphasis equal to if not greater than mission success. These additional pressures, along with growing demands to reduce size, weight and power, coupled with increased performance, drive many projects toward expanding their use of commercial-off-the-shelf (COTS) technologies. While this may reduce direct parts cost and procurement lead times, it undermines many cost-reduction strategies used for conventional SEE RHA and can make radiation testing and analysis one of the most significant risks or worse, a risk neglected altogether. That section will end with some approaches for restoring balance in the troika of mission success, cost, and schedule. This is captured in SEE RHA as risk management: identify the threat, evaluate the threat, and mitigate the threat.

commercial-off-the-shelf (COTS)↗

Strategies for SEE Hardness Assurance From Buy-It-And-Fly-It to Bullet Proof

This part of the course first outlines the conventional Single Event Effect (SEE), radiation hardness assurance (RHA) approach, which emphasizes mission success. Next, Dr. Ladbury will discuss the challenges posed by new satellite platforms (e.g., cubesats, nanosats, etc.), where cost and schedule receive emphasis equal to if not greater than mission success. These additional pressures, along with growing demands to reduce size, weight and power, coupled with increased performance, drive many projects toward expanding their use of commercial-off-the-shelf (COTS) technologies. While this may reduce direct parts cost and procurement lead times, it undermines many cost-reduction strategies used for conventional SEE RHA and can make radiation testing and analysis one of the most significant risksor worse, a risk neglected altogether. That section will end with some approaches for restoring balance in the troika of mission success, cost, and schedule. This is captured in SEE RHA as risk management: identify the threat, evaluate the threat, and mitigate the threat.

commercial-off-the-shelf (COTS)↗

SU-E-T-566: Comparison of VMAT and IMRT for Whole Abdomen Radiation Therapy (WART)

Purpose: Whole Abdomen Radiation Therapy (WART) is used in the treatment of desmoplastic small round cell tumors as well as other tumors with peritoneal dissemination. Intensity modulated radiation therapy (IMRT) is conventionally used to cover the multiple planning target volumes (PTVs) while sparing nearby critical structures, but this approach often requires two isocenters and ≥20 individual treatment fields. Four-field volumetric arc therapy (VMAT) can produce clinically similar treatment plans with the potential to reduce treatment time substantially. Here we examine treatment times and plan robustness for patients undergoing WART. Methods: Twenty patients undergoing WART at our institution were included in this study. Twelve IMRT and 8 VMAT plans utilized upper and lower abdominal isocenters and met similar dose constraints. Treatment times were tabulated from start of daily kV imaging to beam delivery end. Daily treatment couch coordinates were also recorded. From these couch coordinates, difference between actual and planned separation between isocenters was computed. Plan robustness with regard to PTV coverage within the region of field overlap was analyzed for 3 VMAT and 3 IMRT plans assuming a 2σ deviation in isocenter location. Results: The average treatment time for VMAT was 15 minutes shorter than for IMRT (27 minutes vs. 42 minutes). The average deviation in isocenter separation was 0.0 – 0.1 cm in each direction, with a standard deviation of 0.2 – 0.3 cm. Compared with IMRT plans, VMAT plans showed similar loss in PTV coverage for increasing isocenter displacement and similar dose inhomogeneity with decreasing isocenter displacement. Conclusion: Use of VMAT results in substantial time-savings for 2-isocenter whole abdomen radiotherapy plans. VMAT plans show robustness similar to IMRT with respect to isocenter displacement. VMAT should be considered for these very complicated treatments to minimize risk of patient movement during therapy and maximize treatment delivery efficiency.

60 APPLIED LIFE SCIENCES↗

Axion interactions with domain and bubble walls

We show that interactions between axion-like particles (ALPs) and co-dimension one defects, such as phase-transition bubble walls and solitonic domain walls, can lead to important changes in the evolution of both walls and ALPs. The leading effect arises from the change in the ALP decay constant across the interface, which naturally follows from shift-symmetric interactions with the corresponding order parameter. Specifically, we show that for thin walls moving relativistically, an ALP background — such as e.g. axion dark matter — gives rise to a frictional force on the interface that is proportional to γ 2 , with γ the Lorentz factor of the wall, and that this effect is present in both the oscillating and frozen axion regimes. We explore the broader consequences of this effect for bubble and domain walls in the early universe, and show that this source of friction can be present even in the absent of a conventional medium such as radiation or matter. Possible implications include modifications to the dynamics of bubble and domain walls and their corresponding gravitational wave signatures, as well as the generation of a dark radiation component of ALPs in the form of ultra-relativistic ‘axion shells’ with Lorentz factor γ shell ≃ 2γ 2 ≫ 1 that may remain relativistic until the present day.

Axions and ALPs↗

Reduction in Radiation-Induced Morbidity by Use of an Intercurrent Boost in the Management of Early-Stage Breast Cancer

Purpose: Electron or photon boost immediately following whole-breast irradiation performed after conservation surgery for early-stage breast cancer is the accepted standard of care. This regimen frequently results in Grade III dermatitis, causing discomfort or treatment interruption. Herein, we compare patients treated with whole-breast irradiation followed by boost compared with a cohort with a planned intercurrent radiation boost. Methods and Materials: The records of 650 consecutive breast cancer patients treated at Allegheny General Hospital (AGH) between 2000 and 2008 were reviewed. Selected for this study were 327 patients with T1 or T2 tumors treated with external beam radiotherapy postlumpectomy. One hundred and sixty-nine patients were treated by whole-breast radiotherapy (WBRT) followed by boost at completion. One hundred fifty-eight were treated with a planned intercurrent boost (delivered following 3,600 cGy WBRT). The mean whole breast radiation dose in the conventionally treated group was 5,032 cGy (range, 4500-5400 cGy), and the mean whole breast dose was 5,097 cGy (range, 4860-5040 cGy) in the group treated with a planned intercurrent boost. Results: The occurrence of Grade III dermatitis was significantly reduced in the WBRT/intercurrent boost group compared with the WBRT/boost group (0.6% vs. 8.9%), as was the incidence of treatment interruption (1.9% vs. 14.2%). With a median follow-up of 32 months and 27 months, respectively, no significant difference in local control was identified. Conclusions: Patients treated with intercurrent boost developed less Grade III dermatitis and unplanned treatment interruptions with similar local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗