Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SNPP VIIRS Day Night Band: Ten Years of On-Orbit Calibration and Performance

Aboard the polar-orbiting SNPP satellite, the VIIRS instrument has been in operation since launch in October 2011. It is a visible and infrared radiometer with a unique panchromatic channel capability designated as a day-night band (DNB). This channel covers wavelengths from 0.5 to 0.9 µm and is designed with a near-constant spatial resolution for Earth observations 24 h a day. The DNB operates at 3 gain stages (low, middle, and high) to cover a large dynamic range. An onboard solar diffuser (SD) is used for calibration in the low gain stage, and to enable the derivation of gain ratios between the different stages. In this paper, we present the SNPP VIIRS DNB calibration performed by the NASA VIIRS characterization support team (VCST). The DNB calibration algorithms are described to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. We provide an evaluation of DNB on-orbit calibration performance. This activity supports the NASA Earth science community by delivering consistent VIIRS sensor data products via the Land Science Investigator-led Processing Systems, including the SD degradation applied for DNB calibrations in detector gain and gain ratio trending. The DNB stray light contamination and its correction are highlighted. Performance validations are presented using comparisons to the calibration methods employed by NOAA’s operational Interface Data Processing Segment. Further work on stray light corrections is also discussed.

VIIRS↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Requirements on the gain calibration for LiteBIRD polarisation data with blind component separation

The detection of primordial B modes of the cosmic microwave background (CMB) could provide information about the early stages of the Universe's evolution. The faintness of this signal requires exquisite calibration accuracy and control of instrumental systematic effects which otherwise could bias the measurements. In this work, we study the impact of an imperfect relative polarisation gain calibration on the recovered value of the tensor-to-scalar ratio r for the LiteBIRD experiment, through the application of the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. We derive requirements on the relative calibration accuracy of the overall polarisation gain (Δg ν ) for each LiteBIRD frequency channel. Our results show that minimum variance techniques, as NILC, are less sensitive to systematic gain calibration uncertainties compared to a parametric approach, if the latter is not equipped with a proper modelling of these instrumental effects. In this study, the most stringent requirements are found in the channels where the CMB signal is relatively brighter, with the tightest constraints at 166 GHz (Δg ν ≈ 0.16%). This differs from the outcome of an analogous analysis performed with a parametric method, where the tightest requirements are obtained for the foreground-dominated channels. Gain calibration uncertainties, corresponding to the derived requirements, are then simultaneously propagated into all frequency channels. By doing so, we find that the overall impact on estimated r is lower than the total gain systematic budget for LiteBIRD approximately by a factor 5, due to the correlations of the impacts of gain calibration uncertainties in different frequency channels. In order to decouple the systematic effect from the specific choice of the model, we derive the requirements assuming constant spectral parameters for the foreground emission. To assess the robustness of the obtained results against more realistic scenarios, we repeat the analysis assuming sky models of intermediate and high complexity. In these further cases, we adopt an optimised NILC pipeline, called the Multi-Clustering NILC (MC-NILC). We find that the impact of gain calibration uncertainties on r is lower than the LiteBIRD gain systematics budget for the intermediate-complexity sky model. For the high-complexity case, instead, it would be necessary to tighten the requirements by a factor 1.8.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Precision calibration of calorimeter signals in the ATLAS experiment using an uncertainty-aware neural network

The ATLAS experiment at the Large Hadron Collider explores the use of modern neural networks for a multi-dimensional calibration of its calorimeter signal defined by clusters of topologically connected cells (topo-clusters). The Bayesian neural network (BNN) approach not only yields a continuous and smooth calibration function that improves performance relative to the standard calibration but also provides uncertainties on the calibrated energies for each topo-cluster. The results obtained by using a trained BNN are compared to the standard local hadronic calibration and to a calibration provided by training a deep neural network. The uncertainties predicted by the BNN are interpreted in the context of a fractional contribution to the systematic uncertainties of the trained calibration. They are also compared to uncertainty predictions obtained from an alternative estimator employing repulsive ensembles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and Validation of the SAIL Radar

Calibration of a weather radar is not a simple process, as is well described and documented in several articles (Chandrasekar, V, L Baldini, N Bharadwaj, and PL Smith. 2015. "Calibration procedures for global precipitation-measurement ground-validation radars." URSI Radio Science Bulletin 2015(355): 45–73, https://10.23919/URSIRSB.2015.7909473.). Direct hardware-based characterization is called calibration whereas indirect check with other sources such as disdrometer, or comparison with other radars or indirect means, is called validation. The validation process has its own measurement error and the comparison should fall within its limit. In the following we describe calibration and validation processes for the SAIL radar. Based on the comparison of calibration and validation, an addition of 2 dB is suggested for the SAIL radar observations, with a nuanced Z dr calibration correction, as presented. If a fixed Z dr calibration is preferred, a bias addition of 0.5 dB is suggested.

54 ENVIRONMENTAL SCIENCES↗

Residual Gas Analyzer Calibration

A technique which employs known gas mixtures to calibrate the residual gas analyzer (RGA) is described. The mass spectra from the RGA are recorded for each gas mixture. This mass spectra data and the mixture composition data each form a matrix. From the two matrices the calibration matrix may be computed. The matrix mathematics requires the number of calibration gas mixtures be equal to or greater than the number of gases included in the calibration. This technique was evaluated using a mathematical model of an RGA to generate the mass spectra. This model included shot noise errors in the mass spectra. Errors in the gas concentrations were also included in the valuation. The effects of these errors was studied by varying their magnitudes and comparing the resulting calibrations. Several methods of evaluating an actual calibration are presented. The effects of the number of gases in then, the composition of the calibration mixture, and the number of mixtures used are discussed.

R H Lilienkamp↗

Apollo experience report: Flight instrumentation calibration

Three types of instrumentation-calibration data were used in the Apollo Program to provide the correct engineering data for tests and mission support. The command and service module instrumentation-component procurement specifications required individual-component calibration, and calibration data for these individual components (conventional-calibration data) were always used for mission data support. A mean standard type of calibration data derived from a statistical sampling of conventional-calibration data was used for test and checkout during the latter part of the Apollo Program. The lunar module instrumentation procurement specification permitted the use of standard-calibration data. These data were applicable to similarly instrumented measurements. The definition, merit, and application of each type of data are discussed.

Demoss, J. F.↗

The calibration and flight test performance of the space shuttle orbiter air data system

The Space Shuttle air data system (ADS) is used by the guidance, navigation and control system (GN&C) to guide the vehicle to a safe landing. In addition, postflight aerodynamic analysis requires a precise knowledge of flight conditions. Since the orbiter is essentially an unpowered vehicle, the conventional methods of obtaining the ADS calibration were not available; therefore, the calibration was derived using a unique and extensive wind tunnel test program. This test program included subsonic tests with a 0.36-scale orbiter model, transonic and supersonic tests with a smaller 0.2-scale model, and numerous ADS probe-alone tests. The wind tunnel calibration was further refined with subsonic results from the approach and landing test (ALT) program, thus producing the ADS calibration for the orbital flight test (OFT) program. The calibration of the Space Shuttle ADS and its performance during flight are discussed in this paper. A brief description of the system is followed by a discussion of the calibration methodology, and then by a review of the wind tunnel and flight test programs. Finally, the flight results are presented, including an evaluation of the system performance for on-board systems use and a description of the calibration refinements developed to provide the best possible air data for postflight analysis work.

Dean, A. S.↗

Prelaunch absolute radiometric calibration of the reflective bands on the LANDSAT-4 protoflight Thematic Mapper

The results of the absolute radiometric calibration of the LANDSAT 4 thematic mapper, as determined during pre-launch tests with a 122 cm integrating sphere, are presented. Detailed results for the best calibration of the protoflight TM are given, as well as summaries of other tests performed on the sensor. The dynamic range of the TM is within a few per cent of that required in all bands, except bands 1 and 3. Three detectors failed to pass the minimum SNR specified for their respective bands: band 5, channel 3 (dead), band 2, and channels 2 and 4 (noisy or slow response). Estimates of the absolute calibration accuracy for the TM show that the detectors are typically calibrated to 5% absolute error for the reflective bands; 10% full-scale accuracy was specified. Ten tests performed to transfer the detector absolute calibration to the internal calibrator show a 5% range at full scale in the transfer calibration; however, in two cases band 5 showed a 10% and a 7% difference.

Barker, J. L.↗

Verification of L-band SAR calibration

Absolute calibration of a digital L-band SAR system to an accuracy of better than 3 dB has been verified. This was accomplished with a calibration signal generator that produces the phase history of a point target. This signal relates calibration values to various SAR data sets. Values of radar cross-section (RCS) of reference reflectors were obtained using a derived calibration relationship for the L-band channel on the ERIM/CCRS X-C-L SAR system. Calibrated RCS values were compared to known RCS values of each reference reflector for verification and to obtain an error estimate. The calibration was based on the radar response to 21 calibrated reference reflectors.

Larson, R. W.↗

A miniature remote deadweight calibrator

A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

Supplee, Frank H., Jr.↗

Effects of switch leakages upon Nimbus-7 SMMR calibration

A calibration model for the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) is studied. This model not only removes major drawbacks of the current calibration model but also helps us understand the performance degradation of the aging instrument. The current Nimbus-7 SMMR calibration algorithm was derived without considering the interference effect between the two orthogonally polarized signals merging at a ferrite polarization selector switch. The resulting calibrated brightness temperatures, considered as a function of scan angle phi, are not symmetric around phi=0. However, neither the origin of the asymmetry nor the manner in which the two orthogonal components are mixed is fully understood. The proposed calibration model incorporates all the leakage factors associated with the ferrite switches along the signal paths. The resulting calibration equations clarify how the orthogonal components of surface brightness are coupled at radiometers. As a consequence, the origin of the asymmetry is clearly identified and explained. In addition, the feasibility of absolute calibration using in-orbit data is discussed.

Han, Daesoo↗

The absolute radiometric calibration of the advanced very high resolution radiometer

An increasing number of remote sensing investigations require radiometrically calibrated imagery from NOAA Advanced Very High Resolution Radiation (AVHRR) sensors. Although a prelaunch calibration is done for these sensors, there is no capability for monitoring any changes in the in-flight absolute calibration for the visible and near infrared spectral channels. Hence, the possibility of using the reflectance-based method developed at White Sands for in-orbit calibration of LANDSAT Thematic Mapper (TM) and SPOT Haute Resolution Visible (HVR) data to calibrate the AVHRR sensor was investigated. Three diffrent approaches were considered: Method 1 - ground and atmospheric measurements and reference to another calibrated satellite sensor; Method 2 - ground and atmospheric measurements with no reference to another sensor; and Method 3 - no ground and atmospheric measurements but reference to another satellite sensor. The purpose is to describe an investigation on the use of Method 2 to calibrate NOAA-9 AVHRR channels 1 and 2 with the help of ground and atmospheric measurements at Rogers (dry) Lake, Edwards Air Force Base (EAFB) in the Mojave desert of California.

Slater, P. N.↗

NASA Aircraft-Satellite Instrument Calibration Project

Ground based prelaunch calibration of satellite instruments usually is not adequate to provide an accurate characterization of the in-orbit performance of a satellite instrument. This is because the ground calibrations may not simulate the in-orbit environment observations of the satellite sensor, or because the sensor characteristics have changed during launch and in-orbit operations. One technique to obtain a meaningful in-orbit calibration of satellite sensors is to acquire simultaneous observations of an Earth scene with the satellite and a well calibrated aircraft or shuttle sensor which has similar characteristics to the satellite sensor. This is a direct in-orbit calibration technique and is usually called vicarious calibration. The experiment with the control instrument must occur above the sensible atmosphere as measured by the satellite sensor to provide a useful improvement to the calibration of the satellite sensor. Some observations on the experiments are made.

Guenther, B. W.↗

On-orbit Metrology and Calibration Requirements for Space Station Activities Definition Study

The Space Station is the focal point for the commercial development of space. The long term routine operation of the Space Station and the conduct of future commercial activities suggests the need for in-space metrology capabilities analogous when possible to those on-Earth. The ability to perform periodic calibrations and measurements with proper traceability is imperative for the routine operation of the Space Station. An initial review, however, indicated a paucity of data related to metrology and calibration requirements for in-space operations. This condition probably exists because of the highly developmental aspect of space activities to date, their short duration, and nonroutine nature. The on-orbit metrology and calibration needs of the Space Station were examined and assessed. In order to achieve this goal, the following tasks were performed: an up-to-date literature review; identification of on-orbit calibration techniques; identification of sensor calibration requirements; identification of calibration equipment requirements; definition of traceability requirements; preparation of technology development plans; and preparation of the final report. Significant information and major highlights pertaining to each task is presented. In addition, some general (generic) conclusions/observations and recommendations that are pertinent to the overall in-space metrology and calibration activities are presented.

Cotty, G. M.↗