Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2013–October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Permit required groundwater monitoring data; Status of compliance activities; Noncompliance issues; and Discussion of the facility’s environmental impacts. During the 2014 permit year, approximately 238 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the downgradient monitoring wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Performance Cold Climate Heat Pump (CCHP) – Final Report

In the U. S., there are approximately 2.6 million dwellings that use electricity for heating in very cold and cold regions with an annual energy consumption of 0.16 quads. A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (> 70% compared to strip heating). It can result in an annual primary energy savings of 0.1 Quads when fully deployed, which is equivalent to 5.9 million tons of annual CO2 emissions reduction. The outcome of this project is the development of a split system, cold climate heat pump (CCHP) providing 36,000 Btu/hr (10.6 kW) heating capacity with a COP > 4.0 (at the 47°F (8.3°C) AHRI rating condition) and maximum efficiency degradation of 50% and capacity loss of 25% at -13°F (-25°C) ambient conditions. Between 2012 and 2015, Oak Ridge National Laboratory (ORNL) and Emerson Climate Technologies engaged in a Cooperative Research and Development Agreement (CRADA) to develop a high efficiency, cold climate heat pump for the US residential market. We went through an exhaustive technologies survey to select energy efficient and cost-effective components. We conducted in-depth engineering design and building energy modeling, based on the ORNL Heat Pump Design Model (HPDM) and EnergyPlus, by which we made the final choices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Membrane lipid and expression responses of Saccharolobus islandicus REY15A to acid and cold stress

Archaea adjust the number of cyclopentane rings in their glycerol dibiphytanyl glycerol tetraether (GDGT) membrane lipids as a homeostatic response to environmental stressors such as temperature, pH, and energy availability shifts. However, archaeal expression patterns that correspond with changes in GDGT composition are less understood. Here we characterize the acid and cold stress responses of the thermoacidophilic crenarchaeon Saccharolobus islandicus REY15A using growth rates, core GDGT lipid profiles, transcriptomics and proteomics. We show that both stressors result in impaired growth, lower average GDGT cyclization, and differences in gene and protein expression. Transcription data revealed differential expression of the GDGT ring synthase grsB in response to both acid stress and cold stress. Although the GDGT ring synthase encoded by grsB forms highly cyclized GDGTs with ≥5 ring moieties, S. islandicus grsB upregulation under acidic pH conditions did not correspond with increased abundances of highly cyclized GDGTs. Our observations highlight the inability to predict GDGT changes from transcription data alone. Broader analysis of transcriptomic data revealed that S. islandicus differentially expresses many of the same transcripts in response to both acid and cold stress. These included upregulation of several biosynthetic pathways and downregulation of oxidative phosphorylation and motility. Transcript responses specific to either of the two stressors tested here included upregulation of genes related to proton pumping and molecular turnover in acid stress conditions and upregulation of transposases in cold stress conditions. Overall, our study provides a comprehensive understanding of the GDGT modifications and differential expression characteristic of the acid stress and cold stress responses in S. islandicus.

59 BASIC BIOLOGICAL SCIENCES↗

Utilizing Earth Observations of Soil Freeze/Thaw Data and Atmospheric Concentrations to Estimate Cold Season Methane Emissions in the Northern High Latitudes

The northern wetland methane emission estimates have large uncertainties. Inversion models are a qualified method to estimate the methane fluxes and emissions in northern latitudes but when atmospheric observations are sparse, the models are only as good as their a priori estimates. Thus, improving a priori estimates is a competent way to reduce uncertainties and enhance emission estimates in the sparsely sampled regions. Here, we use a novel way to integrate remote sensing soil freeze/thaw (F/T) status from SMOS satellite to better capture the seasonality of methane emissions in the northern high latitude. The SMOS F/T data provide daily information of soil freezing state in the northern latitudes, and in this study, the data is used to define the cold season in the high latitudes and, thus, improve our knowledge of the seasonal cycle of biospheric methane fluxes. The SMOS F/T data is implemented to LPX-Bern DYPTOP model estimates and the modified fluxes are used as a biospheric a priori in the inversion model CarbonTracker Europe-CH 4 . The implementation of the SMOS F/T soil state is shown to be beneficial in improving the inversion model’s cold season biospheric flux estimates. Our results show that cold season biospheric CH4 emissions in northern high latitudes are approximately 0.60 Tg lower than previously estimated, which corresponds to 17% reduction in the cold season biospheric emissions. This reduction is partly compensated by increased anthropogenic emissions in the same area (0.23 Tg), and the results also indicates that the anthropogenic emissions could have even larger contribution in cold season than estimated here.

54 ENVIRONMENTAL SCIENCES↗

Corrosion of Zinc Cold Spray Coatings in a Wet Sweet and Sour Gas Environment

Internal corrosion is a problem for steel pipelines transporting natural gas or CO 2 containing water and partial pressures of H 2 S higher than 0.3 kPa (0.05 psi). This work aims to mitigate internal corrosion in steel pipelines transporting natural gas containing H 2 S using cold spray coatings. Two types of the cold spray binary metallic coatings (zinc chromium [ZnCr]. zinc niobium [ZnNb]) were studied using electrochemical techniques: potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy. The corrosion resistance of cold spray coatings (ZnCr, ZnNb) was evaluated in an environment containing 4 bar CO 2 pressure, simulating the partial pressures found in gas transmission lines over a solution of 3.5 wt% NaCl heated to 40°C. A concentration of 0.003 M Na 2 S 2 O 3 ·5H 2 O, corresponding to H 2 S partial pressures around 0.079 bar (1.146 psi), was used to simulate sour conditions. Postcorrosion surface characterization was performed using a scanning electron microscope (SEM) equipped with an energy-dispersive x-ray spectroscope (EDS) and x-ray diffraction analysis. The data showed that the presence of 0.003 M Na 2 S 2 O 3 ·5H 2 O shifted the corrosion potential to more anodic values and decreased the corrosion current density. Both coatings showed similar behavior after 1 h of exposure in the CO 2 /H 2 S environment, indicating that similar electrochemical reactions were occurring on ZnNb and ZnCr. SEM images and EDS surface analyses for specimens showed a significant change in the surface chemical composition of carbon steel coated with ZnNb and ZnCr after 24 h of immersion. In the presence of thiosulfate (under sour conditions), the formation of corrosion product layers (ZnCO 3 and ZnS) on top of ZnNb and ZnCr coatings increased their corrosion resistance, which helped to reduce their corrosion by a factor of 2. Under a sweet environment, the corrosion rates for steel coated with cold spray coatings after 14 d of exposure are lower than that for galvanized steel by a factor of 5 due to the ZnCO 3 layer formed on top of the coatings. The ZnCO 3 layer formed on the steel surface acts as a physical barrier against corrosion by blocking the diffusion of corrosive species to the surface. No localized attack was observed. ZnCr Cold spray coating with defect showed promising corrosion protection against CO 2 corrosion (sweet corrosion) after 14 d of exposure to a CO 2 environment. Here, the scratch on the coating simulated damage created in service, and it was deep enough to expose the substrate material (steel). The formation of zinc oxide (ZnO) and zinc carbonate (ZnCO 3 ) on the scratch confirmed the cathodic protection of the steel by ZnCr and ZnNb coatings.

36 MATERIALS SCIENCE↗

Baroreflex modulation of muscle sympathetic nerve activity during cold pressor test in humans

The purpose of this project was to test the hypothesis that baroreceptor modulation of muscle sympathetic nerve activity (MSNA) and heart rate is altered during the cold pressor test. Ten subjects were exposed to a cold pressor test by immersing a hand in ice water for 3 min while arterial blood pressure, heart rate, and MSNA were recorded. During the second and third minute of the cold pressor test, blood pressure was lowered and then raised by intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure was more negative (P < 0.005) during the cold pressor test (-244.9 +/- 26.3 units x beat(-1) x mmHg(-1)) when compared with control conditions (-138.8 +/- 18.6 units x beat(-1) x mmHg(-1)), whereas no significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. These data suggest that baroreceptors remain capable of modulating MSNA and heart rate during a cold pressor test; however, the sensitivity of baroreflex modulation of MSNA is elevated without altering the sensitivity of baroreflex control of heart rate.

NASA Discipline Cardiopulmonary↗

Use of X-Ray Tomography to Elucidate Cold Cap Structure in Waste Glass Melter

In a waste glass melter, the cold cap plays a vital role in establishing the melt rate for a particular melter feed. Data from x-ray tomography of laboratory-scale cold caps provide insight into the topology of bubble distribution within the cold cap for various feed compositions at temperatures from 600°C to 1040°C. The images were thresholded to capture features of interest, then processed by software to obtain statistics that can be used to characterize bubble topology. Statistics obtained include total pellet volume, porosity, bubble size distribution and morphology as a function of temperature. These statistics will be used to compare the melting behavior of the different glass formulations as a function of temperature. Information on bubble topology at various temperatures will be used to synthetically generate a cold cap structure that can be used to model heat transfer through the cold cap layer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Role of surface heat fluxes underneath cold pools

Abstract The role of surface heat fluxes underneath cold pools is investigated using cloud‐resolving simulations with either interactive or horizontally homogenous surface heat fluxes over an ocean and a simplified land surface. Over the ocean, there are limited changes in the distribution of the cold pool temperature, humidity, and gust front velocity, yet interactive heat fluxes induce more cold pools, which are smaller, and convection is then less organized. Correspondingly, the updraft mass flux and lateral entrainment are modified. Over the land surface, the heat fluxes underneath cold pools drastically impact the cold pool characteristics with more numerous and smaller pools, which are warmer and more humid and accompanied by smaller gust front velocities. The interactive fluxes also modify the updraft mass flux and reduce convective organization. These results emphasize the importance of interactive surface fluxes instead of prescribed flux boundary conditions, as well as the formulation of surface heat fluxes, when studying convection.

54 ENVIRONMENTAL SCIENCES↗

On the sizes and lifetimes of cold pools

Cold pools of air, which are formed by evaporating precipitation, play a critical role in the triggering of new precipitation. Despite their recognized importance, little effort has been devoted to building simple models of their dynamics. Here, analytical equations are derived for the radius, height, and buoyancy of a cylindrical cold pool as a function of time, and a scale analysis reveals that entrainment is a dominant influence. These governing equations yield simple expressions for the maximum sizes and lifetimes of cold pools. The terminal radius of a cold pool is relatively insensitive to its initial conditions, with a typical maximum radius of about 14 times the initial radius, give or take a factor of 2. The terminal time of a cold pool, on the other hand, can vary over orders of magnitude depending on its initial potential and kinetic energies. Lastly, these predictions are validated against large-eddy simulations.

54 ENVIRONMENTAL SCIENCES↗

Characterization of a cold-active bacterium isolated from the South Pole “Ice Tunnel”

Abstract Extremely cold microbial habitats on Earth (those below -30 °C) are rare and have not been surveyed for microbes as extensively as environments in the 0 to -20 °C range. Using cryoprotected growth media incubated at -5 °C, we enriched a cold-active Pseudomonas species from -50 °C ice collected from a utility tunnel for wastewater pipes under Amundsen–Scott South Pole Station, Antarctica. The isolate, strain UC-1, is related to other cold-active Pseudomonas species, most notably P. psychrophila, and grew at -5 °C to +34–37 °C; growth of UC-1 at +3 °C was significantly faster than at +34 °C. Strain UC-1 synthesized a surface exopolymer and high levels of unsaturated fatty acids under cold growth conditions. A 16S rRNA gene diversity screen of the ice sample that yielded strain UC-1 revealed over 1200 operational taxonomic units (OTUs) distributed across eight major classes of Bacteria. Many of the OTUs were Clostridia and Bacteriodia and some of these were probably of wastewater origin. However, a significant fraction of the OTUs were Proteobacteria and Actinobacteria of likely environmental origin. Our results shed light on the lower temperature limits to life and the possible existence of functional microbial communities in ultra-cold environments.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Hot- and Cold-Rolled Loads in Medium-Mn TRIP Steels

The purpose of this work is to investigate the hot- and cold-rolling requirements to produce third-generation advanced high-strength steels (AHSS). Therefore, five medium-Mn (10 to 14 wt pct Mn) alloys that exhibit transformation-induced plasticity (TRIP) were compared to a commercially produced grade of AISI 1018 using hot- and cold-rolling experiments. Experimental data collected from a STANAT instrumented rolling mill was utilized to measure force and torque during hot- and cold-rolling. Experimental data were processed by a 1D analytical model, based on Orowan model, to determine rolling pressure. It was determined that pressures required to hot-roll TRIP alloys are 1.4 to 1.8 times greater than pressures for rolling AISI 1018 steel. Cold rolling of the medium-Mn TRIP steels was found to be 1.5 to 2.8 times greater than the AISI 1018 steel. Mechanical and microstructural characterization was also performed and the variation in rolling pressure was related to the starting microstructural constituents, and alloys containing greater starting quantities of ε-martensite in the microstructure had higher flow stresses at equivalent rolling strains during cold rolling.

36 MATERIALS SCIENCE↗

Evolution of Residual Stress and Distortion of Cold-Rolled Bearing Ring from Annealing to Quenched-Tempered Heat Treatment

This study investigates the correlation between the residual stress and distortion behavior of a cold-rolled ring from the annealing to quenching-tempering (QT) process. Due to the cold-rolled process, the external periphery of the bearing ring experiences a compressive residual stress. To relieve the residual stress, cold-rolled rings are annealed at 700 °C which is higher than the starting temperature of recrystallization. When cold-rolled rings are annealed at 700 °C for 15 min, the compressive residual stress is reduced to zero and the outer diameter of the annealed ring becomes larger than that of a non-annealed sample, which is unrelated to annealing time. Simultaneously, the roundness and taper deviation do not obviously change compared with those of non-annealed sample. The stress relaxation during the annealing process was attributed to the recovery and recrystallization of ferrite. Annealing has a genetic influence on the following QT heat treatment, wherein the lowest residual stress is in the non-annealed cold-rolled ring. From the annealing to QT process, the deviation of the outer diameter, roundness, and taper increased with annealing time, a large extend than that of non-annealed samples.

36 MATERIALS SCIENCE↗

Comparative Study of Zinc Cold-Spray Coating and Pre-treatments for Magnesium Alloys

Magnesium (Mg) alloys are appealing for automotive lightweighting owing to their high specific strength. However, their susceptibility to corrosion in harsh environments remains a major challenge. Conventional industrial pre-treatment coatings, including zinc phosphate, chromate conversion, and non-chromate conversion, often exhibit discontinuities and microcracks, leading to localized corrosion near fasteners and parting lines. Here, this study investigates cold-sprayed zinc (Zn) coatings as a novel pre-treatment alternative for high-pressure die cast (HPDC) AZ91 Mg alloys, demonstrating significant improvements in wear and corrosion performance. Cold spray produces uniform and robust coatings, reducing wear rate by over 50% and reducing corrosion rate by over 99.3%, as measured by evolved hydrogen release, compared to traditional pre-treatments. Multimodal corrosion testing reveals that Zn cold-spray coatings form a protective layer during exposure, minimizing general and filiform corrosion, and exhibiting corrosion potential (E corr ) that is nobler by ~ 400 mV than the surfaces of both pre-treated and uncoated AZ91. Scalability of cold spray for selective application around multimaterial joints further strengthens their industrial viability. This work establishes Zn cold-spray coatings as highly effective pre-treatment solutions for the advancement of corrosion resistant Mg alloy components in automotive applications.

multimodal corrosion↗

A novel cold-regulated gene from Phlox subulata, PsCor413im1, enhances low temperature tolerance in Arabidopsis

Highlights: • PsCor413im1 expression was induced by cold and ABA. • PsCor413im1 is a chloroplast membrane protein. • Overexpression of PsCor413im1 improves chilling and freezing tolerance in Arabidopsis. Low temperature stress adversely affects plant growth, development, and crop productivity. Analysis of the function of genes in the response of plants to low temperature stress is essential for understanding the mechanism of chilling and freezing tolerance. In this study, PsCor413im1, a novel cold-regulated gene isolated from Phlox subulata, was transferred to Arabidopsis to investigate its function under low temperature stress. Real-time quantitative PCR analysis revealed that PsCor413im1 expression was induced by cold and abscisic acid. Subcellular localization revealed that PsCor413im1-GFP fusion protein was localized to the periphery of the chloroplast, consistent with the localization of chloroplast inner membrane protein AtCor413im1, indicating that PsCor413im1 is a chloroplast membrane protein. Furthermore, the N-terminal of PsCor413im1 was determined to be necessary for its localization. Compared to the wild-type plants, transgenic plants showed higher germination and survival rates under cold and freezing stress. Moreover, the expression of AtCor15 in transgenic plants was higher than that in the wild-type plants under cold stress. Taken together, our results suggest that the overexpression of PsCor413im1 enhances low temperature tolerance in Arabidopsis.

60 APPLIED LIFE SCIENCES↗

Overexpression of a repressor MdMYB15L negatively regulates anthocyanin and cold tolerance in red-fleshed callus

Highlights: • MdMYB15L inhibit the expression of MdCBF2 by binding its promoter. • MdMYB15L interact with MdbHLH33 via its bHLH binding sequence. • MdMYB15L weaken MdbHLH33-induced anthocyanin accumulation by interacting with MdbHLH33. The cold-induced metabolic pathway and anthocyanin biosynthesis play important roles in plant growth. In this study, we identified a bHLH binding motif in the MdMYB15L protein using protein sequence analyses. Yeast two-hybrid and pull-down assays showed that MdMYB15L could interact with MdbHLH33. Overexpressing MdMYB15L in red-fleshed callus inhibited the expression of MdCBF2 and resulted in reduced cold tolerance but did not affect anthocyanin levels. Chip-PCR and EMSA analysis showed that MdMYB15L could bind the type II cis-acting element found in the MdCBF2 promoter. Overexpressing MdMYB15L in red-fleshed callus overexpressing MdbHLH33 also reduced cold tolerance and reduced MdbHLH33-induced anthocyanin biosynthesis. Knocking out the bHLH binding sequence of MdMYB15L (LBSMdMYB15L) prevented LBSMdMYB15L from interacting with MdbHLH33. Overexpressing LBSMdMYB15L in red-fleshed callus overexpressing MdbHLH33 also reduced cold tolerance and reduced MdbHLH33-induced anthocyanin biosynthesis. Together, these results suggested that an apple repressor MdMYB15L might play a key role in the cold signaling and anthocyanin metabolic pathways.

60 APPLIED LIFE SCIENCES↗

A Novel Surface Restoration Method for Hydropower Steel Components: Plasma Gouging and Inconel Cold Spray Coating for Material Repair

A novel surface restoration approach combining plasma gouging with subsequent cold spray deposition is demonstrated in this study. Plasma gouging effectively removes the damaged steel surface, leaving grooves and forming a plasma gouging affected zone up to ~300?µm thick. Within this zone, a hardened martensitic layer with a peak hardness of ~370?HV—almost twice that of the base substrate (~200?HV)—is produced. Following plasma gouging, cold spray deposition is applied to rebuild the surface. Experimental results reveal that cold spray coatings deposited at low energy suffer from delamination, whereas high energy cold spray deposits yield a well-bonded coating. Microstructural analysis further shows that the martensitic layer formed by plasma gouging undergoes dynamic recrystallization during cold spray, reducing the hardness to 317?HV. These findings demonstrate the feasibility of this hybrid method for effective surface restoration of damaged steel components.

Wang, Tianhao↗