Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HL-LHC Beam Dynamics with Hollow Electron Lenses

Each of the two proton beams in the High-Luminosity Large Hadron Collider (HL-LHC) will carry a total energy of 720 MJ. One concern for machine protection is the energy stored in the transverse beam tails, estimated to potentially reach up to 5% of the total stored energy. Several failure scenarios could drive these tails into the collimators, potentially causing damage and therefore severely affecting operational efficiency. Hollow Electron Lenses (HEL) were integrated in the HL-LHC baseline to mitigate this risk by depleting the tails in a controlled way. A hollow-shaped electron beam runs co-axially to the hadron beam over about 3 m, such that halo particles at large amplitudes become unstable, while core particles ideally remain undisturbed. Residual fields from e-beam asymmetries can, however, induce emittance growth of the beam core. Various options for the pulsing of the HEL are considered and are compared using two figures of merit: halo depletion efficiency and core emittance growth. This contribution presents simulations for these two effects with different HEL pulsing modes using the final HL-LHC optics, that was optimized at the location of the lenses.

43 PARTICLE ACCELERATORS↗

The development programme of cathodes and electron guns for the Hollow Electron Lenses of the High Luminosity LHC project1

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, has to deliver a current up to 5 A. This is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

Status of the laser manipulations of H- beam at J-PARC

The laser manipulations of H- ion beam by single or double neutralization is a very promising technique and highly essential to utilized in accelerator processes such as stripping, pulse chopping, collimation, extraction, and beam diagnostics for the present and future high-intensity proton accelerators. At J-PARC, we are preparing for a POP (Proof-of-Principle) demonstration 400 MeV H- stripping by using only lasers. A prototype YAG laser system and a laser cavity system to reduce the laser power are being developed through 3 MeV H- neutralization studies. Fermilab utilizes H- neutralization at 0.75 MeV by establishing a laser Notcher system for a gap in the H- pulse needed for a clean beam extraction from the ring. To minimize the laser power and maximize the interaction efficiency are common issue at both laboratories. Under the US-Japan collaboration for high-intensity neutrino beam, we are closely working to establish recycling/reusing of seed laser pulses to reduce a size of the laser system. In parallel, we have also developed non-destructive beam diagnostic systems at lower H- energy of 3 MeV, which will be implemented to the 400 MeV as well as easily applicable to the Fermilab linac including PIP-II linac. Installation of the laser system at J-PARC linac for 400 MeV H- stripping is ongoing to start the POP experimental study in 2023.

43 PARTICLE ACCELERATORS↗

Progress in the design of the future circular collider FCC-ee interaction region

In this paper we discuss the latest developments for the FCC-ee interaction region layout, which represents one of the key ingredients to establish the feasibility of the FCC-ee. The collider has to achieve extremely high luminosities over a wide range of center-of-mass energies with two or four interaction points. The complex final focus hosted in the detector region has to be carefully designed, and the impact of beam losses and of any type of synchrotron radiation generated in the interaction region, including beamstrahlung, have to be evaluated in detail with simulations. We give an overview of the progress of the whole machine-detector-interface-related studies, among which are the updated mechanical model of the interaction region, the plans for a novel R&D activity of a IR mockup which is just starting, the collimation scheme and evaluation of beam induced backgrounds in the detectors, evaluation of radiation dose in the experimental area, and MDI integration with the detector.

43 PARTICLE ACCELERATORS↗

Towards Improving luminosity using optics tuning and data-driven methods

The results of Run 24 experiments at Relativistic Heavy Ion Collider (RHIC) for improving luminosity using optics tuning are presented in this study. In the first experiment, MADx matching was used to output magnet strengths corresponding to specific s star movements around Interaction Region 8 (IR8). The corresponding Zero Degree Calorimeter (ZDC) signal was measured in place of luminosity, and Bayesian Optimization aids search of optimal movements. It was found that values retrieved from matching were inaccurate, resulting in negative feedback loops. The second experiment focused on calculating accurate s star movements. The matching method was replaced with a linear sensitivity matrix, directly relating optics to power supply, and its null space was used to fit constraints such as hysteresis effects. At the experiment, beam losses were observed at collimators around boundary of IR8, which were fixed for the third experiment. Dynamic mode decomposition was also introduced to improve quality of turn-by-turn (TBT) data as well as accuracy and consistency of optics measurements at IR8. These improvements will be tested in the experiment of next RHIC run for luminosity optimization.

Accelerator Physics↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

HERMES 2019 Upgrade Characterization - Quick Look Report (UUR)

Characterizing the electromagnetic environment created by the recently upgraded HERMES III pulser is the primary objective addressed by this report. The pulser upgrade design was intended not only to provide higher electric field and magnetic field illumination amplitudes but also to provide a more collimated beam, focused along the center-line of the courtyard. For high-voltage pulsers to be useful as qualification systems, they must have the requisite peak values and uniform, predictable peak field spatial patterns. To assess the peak electric field values and uniformity of the spatial pattern of the electric fields for the upgraded HERMES system, a 1 6 full-power shot illumination of 9 electric and 9 magnetic field sensors in the courtyard of the HERMES III facility was conducted. The data acquired from this test showed an increase an increase in electric field amplitude, but still an asymmetry in the spatial distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

MCNP calculations concerning the UW 137 Cs release event (Final Report)

This document supersedes earlier reports (LA-UR-19-32358 and LA-UR-20-22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with duct and plenum walls. Specifically, for duct and plenum dimensions and construction details of interest to the University of Washington ¹³⁷Cs release event. This document also corrects some of the data presented in the earlier LA-UR reports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗

NDSE Static Series V & VI Test Results

The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum Algorithms for Collider Physics (Final Report)

The goal of this project was to unite powerful analysis techniques in high-energy physics (HEP) with cutting-edge advances in quantum information science (QIS). Almost every event at the Large Hadron Collider (LHC) involves jets, collimated sprays of particles that are copiously produced in proton-proton collisions. Current LHC algorithms to identify and classify jets are constrained by the limits of classical computation. Quantum algorithms could fundamentally change how collider data is analyzed, by speeding up existing classical algorithms and by enabling new quantum jet representations. By exploiting the capabilities of quantum computation, this research confronted the challenge of data analysis in collider physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First-Scatter Source Generation in GADRAS

A new scatter calculation algorithm has been implemented in the Gamma Detector Response and Analysis Software (GADRAS) package that accounts for spectral effects of scattering materials not in the line of sight of the detector and the source. Previously, GADRAS would only apply scattering effects due to materials that fall between the source and detector. This new routine will allow better modeling of various scenarios including gamma imagers, collimated detectors, or traditional gamma detectors where scattering materials are present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for dark matter decaying to two displaced muons produced in proton-proton collisions at 13 TeV with the CMS detector, and for dark photons produced in electron-positron fixed-target collisions at 500 MeV with the PADME detector

Two novel searches for dark matter using particle accelerators are presented. The first is a search for inelastically-coupled dark matter with the CMS detector at CERN, relying on 137 fb$^{-1}$ of proton-proton collision data collected at 13 TeV center-of-mass energy between 2016 and 2018. The search strategy exploits the striking signature expected of inelastic dark matter: a pair of displaced, soft, and narrow muons collimated with missing transverse momentum and recoiled off an initial-state radiation jet. This is the first search for inelastic dark matter at a hadron collider. The second experiment is PADME, a small-scale detector to search for dark photons located in Frascati, Italy. PADME seeks to detect the production of dark photons in positron-electron collisions with a stationary diamond target and a 500 MeV positron beam. The missing-mass technique employed in the experiment relies on constraining all four-momenta in the system except for the dark photon and lookin g for a bump in the resulting invariant mass distribution corresponding to the dark photon's mass. The projected sensitivity for both experiments is compared in the context of highlighting the need for a comprehensive experimental search program for dark matter. Both analyses expect first public results by the end of 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NREL's HydroGEN Photoreactor Platform Design and Characterization

This technical report details the design, fabrication, and construction of a flow-through photoreactor developed at The National Renewable Energy Laboratory (NREL). The photoreactor is designed to facilitate indoor or outdoor testing on photoelectrochemical or integrated solar water splitting devices. The photoreactor design described here is based on a previous demonstration. The photoreactor version described herein contains several advanced design features that include: 1) Chassis-chuck two-part design, 2) Separable counter electrode compartments (here, the counter electrodes are anodes), 3) Reduced electrode separation to reduce electrolyte resistance, 4) Improved flow pattern for bubble removal, 5) Mounting for spectroradiometer receptor, 6) Fresnel lens and collimating tube attachments. The photoreactor presented here was designed primarily to accommodate photocathode materials in an illuminated compartment and a dark anode as the oxygen evolution catalyst. The build materials were thus chosen to for acid electrolyte compatibility. Other embodiments could accommodate a photoanode with dark hydrogen evolution catalyst and other build materials for alkaline compatibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signature Analysis Utilizing a Dynamic Molten Salt Reactor Model for MC&A

Moving from traditional fixed fuel nuclear reactor systems to a mobile, dynamic fuel system that has dissolved special nuclear material in a molten salt is a paradigm shift in several respects. One major consideration is how to develop effective nuclear material controls and accounting for these novel reactor systems. The Molten Salt Reactor Experiment is one example of a critical molten salt system and provided a significant reference library based on the documented effort. But it was low thermal power that was not intended to reflect a commercial scale electricity production design. Therefore, to facilitate and assist vendors with domestic licensing considerations, research is underway to identify methods that could be used for domestic safeguards approaches for these novel reactor systems. This research presents the results of a signature analysis of data generated from three simulated scenarios using the molten salt demonstration reactor model defined in the Transient Simulation Framework of Reconfigurable Modules. Each scenario provides 1 hour isotope inventories over a 180 day period. The scenarios investigated provide test cases to examine if direct gamma-ray spectroscopy of the fuel can be used to identify changes comparing a base case (no reactivity control and fixed fission contribution) to an insertion of reactivity (10 pcm no change in fission composition) and a change in fission composition. The analysis demonstrates that monitoring the total count rate in a highly collimated high-resolution photon energy spectrum is sensitive to perturbations imposed into the reactor model. The total photon count rate changes ≈2% for the fission composition change and ≈4.5% for the reactivity insertion compared to the base case. However, both scenarios show an increase in the total photon count rate. The total photon count rate can be used to identify changes due to power (number of fissions) but not due to a change in the material undergoing fission. To distinguish between the two cases of increased power, the photon spectrum would require an intensive analysis technique. A photon peak count rate ratio analysis could be used to identify changes in the fissile material fission generation in the core through identification of a static peak that shows little variation to the source of fission and a highly varying peak. The photon peak strength will ultimately be determined by the isotope’s fission yield. A preliminary analysis investigating the coupling of the isotope’s fission yield and its concentration in the fuel salt derived from the modeling has been performed. A ratio analysis of the photon peak count rates of 140 La to 99 Mo demonstrated that the reactivity insertion creates a distinct difference in the ratio compared to the fission composition change scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gamma spectrometry uranium isotopic analysis rodeo: Summary of GADRAS results

This report summarizes GADRAS methods and gamma spectrometry rodeo uranium isotopic analysis results for high energy resolution H3D M400 cadmium zinc telluride (CZT) and ORTEC Micro Detective high-purity germanium (HPGe) spectra of uranium isotopic standards collected at Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) over a two-year measurement campaign. During the campaign, measurements were performed with the detectors unshielded, side shielded, and collimated. In addition, measurements of the uranium isotopic standards were performed unshielded and shielded.

07 ISOTOPE AND RADIATION SOURCES↗