Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computer controlled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

Improved Circuit For Hot-Film Anemometer

Circuit suitable for automation or computer control of setup and operation. Hot-film or hot-wire anemometer circuit features individual current drives for two arms of wheatstone bridge, plus other features that provide improved calibration and automated or computer-controlled operation.

Gray, David L.↗

Differential Measurement Periodontal Structures Mapping System

This invention relates to a periodontal structure mapping system employing a dental handpiece containing first and second acoustic sensors for locating the Cemento-Enamel Junction (CEJ) and measuring the differential depth between the CEJ and the bottom of the periodontal pocket. Measurements are taken at multiple locations on each tooth of a patient, observed, analyzed by an optical analysis subsystem, and archived by a data storage system for subsequent study and comparison with previous and subsequent measurements. Ultrasonic transducers for the first and second acoustic sensors are contained within the handpiece and in connection with a control computer. Pressurized water is provided for the depth measurement sensor and a linearly movable probe sensor serves as the sensor for the CEJ finder. The linear movement of the CEJ sensor is obtained by a control computer actuated by the prober. In an alternate embodiment, the CEJ probe is an optical fiber sensor with appropriate analysis structure provided therefor.

Companion, John A.↗

Roughness Based Crossflow Transition Control: A Computational Assessment

A combination of parabolized stability equations and secondary instability theory has been applied to a low-speed swept airfoil model with a chord Reynolds number of 7.15 million, with the goals of (i) evaluating this methodology in the context of transition prediction for a known configuration for which roughness based crossflow transition control has been demonstrated under flight conditions and (ii) of analyzing the mechanism of transition delay via the introduction of discrete roughness elements (DRE). Roughness based transition control involves controlled seeding of suitable, subdominant crossflow modes, so as to weaken the growth of naturally occurring, linearly more unstable crossflow modes. Therefore, a synthesis of receptivity, linear and nonlinear growth of stationary crossflow disturbances, and the ensuing development of high frequency secondary instabilities is desirable to understand the experimentally observed transition behavior. With further validation, such higher fidelity prediction methodology could be utilized to assess the potential for crossflow transition control at even higher Reynolds numbers, where experimental data is currently unavailable.

Li, Fei↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Multimodality instrument for tissue characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

Mah, Robert W.↗

The Process of Developing a Multi-Cell KEMS Instrument

Multi-cell KEMS offers many advantages over single cell instruments in regard to in-situ temperature calibration and studies on high temperature alloys and oxides of interest to NASA. The instrument at NASA Glenn is a 90 deg magnetic sector instrument originally designed for single cell operation. The conversion of this instrument to a multi-cell instrument with restricted collimation is discussed. For restricted collimation, the 'field aperture' is in the copper plate separating the Knudsen Cell region and the ionizer and the 'source aperture' is adjacent to the ionizer box. A computer controlled x-y table allows positioning of one of the three cells into the sampling region. Heating is accomplished via a Ta sheet element and temperature is measured via an automatic pyrometer from the bottom of the cells. The computer control and data system have been custom developed for this instrument and are discussed. Future improvements are also discussed.

Copland, E. H.↗

Variable-Compliance Couplings For Heavy Lifting

New coupling devices contain manual or electronically controlled, motorized drives that vary stiffnesses. Short, clamped lengths of cable provide compliance. Using threaded rods, cables stretched, relaxed, or folded to make coupling more or less stiff. In more-advanced device, brackets holding cables moved by stepping motor via gearbox and ball screw. Motor operates under computer control with position feedback. Control computer commands greater stiffness during operations requiring precise positioning, and greater compliance to accommodate manufacturing tolerances. Intended for use in wrist joints of robotic manipulators and other industrial equipment that must lift heavy objects.

Kerley, James↗

Fielding An Amphibious UAV: Development, Results, and Lessons Learned

This report summarizes the work completed on the design and flight-testing of a small, unmanned, amphibious demonstrator aircraft that flies autonomously. The aircraft named ACAT (Autonomous Cargo Amphibious Transport) is intended to be a large cargo carrying unmanned aircraft that operates from water to avoid airspace and airfield conflict issues between manned and unmanned aircraft. To demonstrate the feasibility of this concept, a demonstrator ACAT was designed, built, and flown that has a six-foot wingspan and can fly autonomously from land or water airfield. The demonstrator was designed for a 1-hour duration and 1-mile telemetry range. A sizing code was used to design the smallest demonstrator UAV to achieve these goals. The final design was a six-foot wingspan, twin hull configuration that distributes the cargo weight across the span, reducing the wing structural weight. The demonstrator airframe was constructed from balsa wood, fiberglass, and plywood. A 4-stroke model airplane engine powered by methanol fuel was mounted in a pylon above the wing and powers the ACAT UAV. Initial flight tests from land and water were conducted under manual radio control and confirmed the amphibious capability of the design. Flight avionics that were developed by MLB for production UAVs were installed in the ACAT demonstrator. The flight software was also enhanced to permit autonomous takeoff and landing from water. A complete autonomous flight from ahard runway was successfully completed on July 5, 2001 and consisted of a take-off, rectangular flight pattern, and landing under complete computer control. A completely autonomous flight that featured a water takeoff and landing was completed on October 4, 2001. This report describes these activities in detail and highlights the challenges encountered and solved during the development of the ACAT demonstrator. hard runway was successfully completed on July 5, 2001 and consisted of a take-off, rectangular flight pattern, and landing under complete computer control. A completely autonomous flight that featured a water takeoff and landing was completed on October 4, 2001. This report describes these activities in detail and highlights the challenges encountered and solved during the development of the ACAT demonstrator.

Pisanich, Greg↗

Atmospheric effects on the Space Shuttle approach and landing

The present work describes piloted simulations of Space Shuttle approach and landing where the pilot either flies the aircraft or monitors a computer-controlled flight with the option to take control. The simulated runs encompassed approach to the airport, acquisition of the glide slope and localizer, and accomplishing final flare and touchdown. The degree of difficulty associated with the flight task was imposed through modeled atmospheric winds and superimposed atmospheric turbulence. The simulator models the Orbiter vehicle with the aid of an all-digital computer complex and a fixed-base crew station. Comparison between piloted and computer-controlled responses to unexpected atmospheric conditions was obtained by recording data from instrument displays available to the pilot.

Ragsdale, W. A.↗

Inertial Pointing and Positioning System

An inertial pointing and control system and method for pointing to a designated target with known coordinates from a platform to provide accurate position, steering, and command information. The system continuously receives GPS signals and corrects Inertial Navigation System (INS) dead reckoning or drift errors. An INS is mounted directly on a pointing instrument rather than in a remote location on the platform for-monitoring the terrestrial position and instrument attitude. and for pointing the instrument at designated celestial targets or ground based landmarks. As a result. the pointing instrument and die INS move independently in inertial space from the platform since the INS is decoupled from the platform. Another important characteristic of the present system is that selected INS measurements are combined with predefined coordinate transformation equations and control logic algorithms under computer control in order to generate inertial pointing commands to the pointing instrument. More specifically. the computer calculates the desired instrument angles (Phi, Theta. Psi). which are then compared to the Euler angles measured by the instrument- mounted INS. and forms the pointing command error angles as a result of the compared difference.

Yee, Robert↗

Toward the fabrication of a 5 μm resolution Wolter microscope for the National Ignition Facility

Advancements in computer-controlled polishing, metrology, and replication have led to a x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. The mirror is a nickel-cobalt replicated full-shell mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed and fabricated for a 8 m source-to-detector distance microscope, with 10× magnification. A computer controlled polishing process corrected the low-frequency mandrel figure to < 2.0 nm RMS error. The mandrel design was optimized to reduce shell distortions that occur mainly < 20 mm from the shell ends. This design, in combination with improved replication tooling design and refined bath parameters informed by a detailed COMSOL model, have led to reductions in replication errors in the mirror shell. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated < 10 μm FWHM source plane imaging resolution. Here we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving 5 μm FWHM resolution.

Grazing Incidence, Wolter Microscope, X-ray Optics↗

Virtual agents in a simulated virtual training environment

A drawback to live-action training simulations is the need to gather a large group of participants in order to train a few individuals. One solution to this difficulty is the use of computer-controlled agents in a virtual training environment. This allows a human participant to be replaced by a virtual, or simulated, agent when only limited responses are needed. Each agent possesses a specified set of behaviors and is capable of limited autonomous action in response to its environment or the direction of a human trainee. The paper describes these agents in the context of a simulated hostage rescue training session, involving two human rescuers assisted by three virtual (computer-controlled) agents and opposed by three other virtual agents.

Achorn, Brett↗

Development of an adaptive hp-version finite element method for computational optimal control

In this research effort, the usefulness of hp-version finite elements and adaptive solution-refinement techniques in generating numerical solutions to optimal control problems has been investigated. Under NAG-939, a general FORTRAN code was developed which approximated solutions to optimal control problems with control constraints and state constraints. Within that methodology, to get high-order accuracy in solutions, the finite element mesh would have to be refined repeatedly through bisection of the entire mesh in a given phase. In the current research effort, the order of the shape functions in each element has been made a variable, giving more flexibility in error reduction and smoothing. Similarly, individual elements can each be subdivided into many pieces, depending on the local error indicator, while other parts of the mesh remain coarsely discretized. The problem remains to reduce and smooth the error while still keeping computational effort reasonable enough to calculate time histories in a short enough time for on-board applications.

Hodges, Dewey H.↗

Increasing Efficiency at the NTF by Optimizing Model AoA Positioning

The National Transonic Facility (NTF) at NASA Langley Research Center (LaRC) is a national resource for aeronautical research and development. The government, military and private industries rely on the capability of this facility for realistic flight data. Reducing the operation costs and keeping the NTF affordable is essential for aeronautics research. The NTF is undertaking an effort to reduce the time between data points during a pitch polar. This reduction is being driven by the operating costs of a cryogenic facility. If the time per data point can be reduced, a substantial cost savings can be realized from a reduction in liquid nitrogen (LN2) consumption. It is known that angle-of-attack (AoA) positioning is the longest lead-time item between points. In January 2005 a test was conducted at the NTF to determine the cause of the long lead-time so that an effort could be made to improve efficiency. The AoA signal at the NTF originates from onboard instrumentation then travels through a number of different systems including the signal conditioner, digital voltmeter, and the data system where the AoA angle is calculated. It is then fed into a closed loop control system that sets the model position. Each process along this path adds to the time per data point affecting the efficiency of the data taking process. Due to the nature of the closed loop feed back AoA control and the signal path, it takes approximately 18 seconds to take one pitch pause point with a typical AoA increment. Options are being investigated to reduce the time delay between points by modifying the signal path. These options include: reduced signal filtering, using analog channels instead of a digital volt meter (DVM), re-routing the signal directly to the AoA control computer and implementing new control algorithms. Each of these has potential to reduce the positioning time and together the savings could be significant. These timesaving efforts are essential but must be weighed against possible loss of data quality. For example, a reduction in filtering can introduce noise into the signal and using analog channels could result in some loss of accuracy. Data quality assessments need to be performed concurrently with timesaving techniques since data quality parameters are essential in maintaining facility integrity. This paper will highlight time saving efforts being undertaken or studied at the NTF. It will outline the instrumentation and computer systems involved in setting of the model pitch attitude then suggest changes to the process and discuss how these system changes would effect the time between data points. It also discusses the issue of data quality and how the potential efficiency changes in the system could affect it. Lastly, it will discuss the possibility of using an open loop control system and give some pros and cons of this method.

Crawford, Bradley L.↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Numerical computer peripheral interactive device with manual controls

A computer peripheral device is disclosed which includes a joystick whose displacement from a counter position along two axes X and Y in either a plus (+) or a minus (-) direction is sensed. The displacement magnitude in either direction controls the rate of clock pulses provided by a variable frequency clock. The clock pulses from the two clocks are accumulated in two separate counters, whose contents are displayed. The contents of the counters are suppliable to a computer to update the contents of specific cells which define the position of a cursor on a display which is under computer control.

Zygielbaum, A. I.↗

The Spartan attitude control system - Ground support computer

The Spartan Attitude Control System (ACS) contains a command and control computer. This computer is optimized for the activities of the flight and contains very little human interface hardware and software. The computer system provides the technicians testing of Spartan ACS with a convenient command-oriented interface to the flight ACS computer. The system also decodes and time tags data automatically sent out by the flight computer as key events occur. The duration and magnitude of all system maneuvers is also derived and displayed by this system. The Ground Support Computer is also the primary Ground Support Equipment for the flight sequencer which controls all payload maneuvers, and long term program timing.

Schnurr, R. G., Jr.↗