Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The reduction, verification and interpretation of Magsat magnetic data over Canada

Magnetic anomalies of lithospheric origin are weak at Magsat altitudes (20 to 30 nT at most), and are easily masked by much larger effects caused by field-aligned and other currents at high latitudes. Most of Canada lies under the influence of ionospheric currents in the auroral zone and polar cap. A more refined selection of quiet Magsat data allowed a revised scalar magnetic anomaly map of the whole region north of about 40 deg N latitude. Very preliminary vector anomaly maps and absolute vector component maps were derived. The scalar magnitudes show great promise for mapping the total force and anomaly fields. The Z vector data also appear to be good. The horizontal X and Y vector data are seriously contaminated with external fields and maybe other effects.

Coles, R. L.↗

High energy resolution observation of the Crab and AO535 plus 26 in the hard X-ray range

A number of uncertainties exist currently regarding the existence of gamma-ray lines in the Crab spectrum. An investigation was, therefore, conducted, and the Crab was observed for eight hours during a balloon flight from Palestine, TX, on September 26, 1980. It appeared that the binary source AO535 plus 26 contaminated the Crab data. It was, however, possible to separate the two sources. The obtained results are discussed and evaluated. It is found that the possibility of a line at 73 keV with the intensity reported by Ling et al. (1979) can be excluded for the obtained data. The 400 keV line cannot be ruled out. The results concerning AO535 plus 26 are very different from those previously obtained.

Hameury, J. M.↗

OSS-1/STS-3 Shuttle induced atmosphere experiment

Direct light form the Sun and the sunlit Earth, and indirect light from these same sources reflected off parts of the orbiter and its payload were the two major sources of light seen in the bay during spacecraft day. Brightness arising from sunlight reflected off particulates originating from the spacecraft (corona or induced atmosphere) were tentatively identified. Sources of light observed during spacecraft night include large scale diffuse glows associated with Vernier thruster firings, surface glows on the orbiter in the direction of orbiter n motion, and periodic sky brightness structures observed primarily at 4200 A and 6300 A. Some information was obtained on the size and trajectories of individual contaminant particulates. Astronomical data were obtained from large regions of the Milky Way and zodiacal light, including large regions to within 35 deg of the Sun and possibly closer. Coordinated and sometimes simultaneous observations were successfully made from Hawaii and from STS-3 to provide unique information on atmospheric sources and sinks of radiation.

Weinberg, J. L.↗

Environmental Degradation of Solar Reflectors

Report presents results of study of atmospheric degradation of large solar reflectors for power generators. Three general types of reflective surfaces investigated. Report also describes computer buildup and removal (by rain and dew) of contamination from reflectors. Data used to determine effects of soil buildup and best method and frequency of washing at various geographic locations.

Bouquet, F. L.↗

A study of gravity-wave spectra in the troposphere and stratosphere at 5-min to 5-day periods with the Poker Flat MST radar

An analysis of frequency spectra at periods of about 5 days to 5 min from two 20-day sets of velocity measurements in the stratosphere and troposphere region obtained with the Poker Flat mesosphere-stratosphere-troposphere (MST) radar during January and June, 1984 is presented. A technique based on median filtering and averaged order statistics for automatic editing, smoothing and spectral analysis of velocity time series contaminated with spurious data points or outliers is outlined. The validity of this technique and its effects on the inferred spectral index was tested through simulation. Spectra obtained with this technique are discussed. The measured spectral indices show variability with season and height, especially across the tropopause. The discussion briefly outlines the need for obtaining better climatologies of velocity spectra and for the refinements of the existing theories to explain their behavior.

Bemra, R. S.↗

Size-velocity distribution of large ejecta fragments

The characteristics of three primary extraterrestrial craters and the associated craters were examined to generate a size-velocity distribution for large ejecta fragments. The lunar craters Copernicus and Aristillus and the Martian crater Dv on Olympus Mons were used. Attention was focused on the radial distances between the primary and secondary crater centers and the diameters of the secondaries. The primary craters selected are all relatively young, which avoided contamination of the data from secondaries from other primaries. Attempts were made to account for the speed of the hypervelocity impacts and the elemental compositions of the impactors. An apparent velocity cutoff of about 1 km/sec was observed for the secondaries, which implies that no meteoroid impacts can accelerate ejecta to escape velocities from the moon or Mars.

Vickery, A. M.↗

WF/PC internal molecular contamination during system thermal-vacuum test

During the recent system thermal vacuum test of the Wide-Field/Planetary Camera (WF/PC), instrumentation was added to the WF/PC to characterize the internal molecular contamination and verify the instrument throughput down to 1470 angstroms. Analysis of data elements revealed two contaminants affecting the far-ultraviolet (FUV) performance of the WF/PC. The one contaminant (heavy volatile) is correlated with the electronic and housing temperature, and the contamination is significantly reduced when the electronics are operated below plus 8 degrees to plus 10 degrees C. The other contaminant (light volatile) is controlled by the heat pipe temperature, and the contamination is significantly reduced when the Thermal Electric Cooler (TEC) hot-junction temperature is below minus 40 degrees to minus 50 degrees C. The utility of contamination sensors located behind instruments during system tests was demonstrated.

Taylor, Daniel M.↗

Toward decimeter Topex orbit determination using GPS

Several practical aspects of precision GPS-based Topex orbit determination are investigated. Multipath signals contaminating Topex pseudorange data are greatly reduced by placing the GPS antenna on a conducting backplate consisting of concentric choke rings to attenuate signals coming in from the Topex horizon and below, and by elevating it on a boom to keep it well above all reflecting surfaces. A proper GPS antenna cutoff view angle is chosen so that a sufficient number of GPS satellites with good geometry are in view while reception of reflected signals is minimized. The geometrical strength of the tracking data is optimized by properly selecting GPS satellites to be observed so as to provide data with moderate continuity, low PDOP, and common visibility with ground tracking sites. The tracking performance is greatly enhanced when three complementary sites are added to the minimum ground tracking network consisting of the three NASA DSN sites.

Wu, Sien-Chong↗

Observations of the anisotropy in the cosmic microwave background by the FIRS, SK93, and MSAM-I experiments

The observations and results from the FIRS, SK93, and MSAM-1, experiments are discussed. These experiments search for anisotropy in the cosmic microwave background over a range in angular scale from 180 deg to 0.5 deg and a range in frequency from 26 to 680 GHz. Emphasis is placed on the observing strategy and potential systematic errors. Contamination of the data by galactic sources is addressed. Future directions are indicated. The results for all three experiments, as found by us and others, are given in the context of the standard CDM model, Q(sub CDM), and the model-independent band-power estimates.

Kowitt, Matt↗

Visible and Ultraviolet Detectors for High Earth Orbit and Lunar Observatories

The current status of detectors for the visible and UV for future large observatories in earth orbit and the moon is briefly reviewed. For the visible, CCDs have the highest quantum efficiency, but are subject to contamination of the data by cosmic ray hits. For the moon, the level of hits can be brought down to that at the earth's surface by shielding below about 20 meters of rock. For high earth orbits above the geomagnetic shield, CCDs might be able to be used by combining many short exposures and vetoing the cosmic ray hits, otherwise photoemissive detectors will be necessary. For the UV, photoemissive detectors will be necessary to reject the visible; to use CCDs would require the development of UV-efficient filters which reject the visible by many orders of magnitude. Development of higher count rate capability would be desirable for photoemissive detectors.

Woodgate, Bruce E.↗

Discovery and Identification of Dimethylsilanediol as a Contaminant in ISS Potable Water

In September of 2010, analysis of ISS potable water samples was undertaken to determine the contaminant responsible for a rise in total organic carbon (TOC). As analysis of the routine target list of organic compounds did not reveal the contaminant, efforts to look for unknown compounds was initiated, resulting in an unknown peak being discovered in the gas chromatography/mass spectrometry (GC/MS) analysis for glycols. A mass spectrum of the contaminant was then generated by concentrating one of the samples by evaporation and analyzing by GC/MS in full-scan mode. Although a computer match of the compound s identity could not be obtained with the instrument s database, a search with a more up to date mass spectral library yielded a good match with dimethylsilanediol (DMSD). Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) analyses showed abnormally high silicon levels in the samples, confirming that the unknown contained silicon. DMSD was then synthesized to confirm the identification and provide a standard to develop a calibration curve. Further confirmation was provided by external Direct Analysis in Real Time (DART) GC/MS analysis. A preliminary GC/MS method was then developed and archived samples from various locations on ISS were analyzed to determine the extent of the contamination and provide data for troubleshooting. This paper describes these events in more detail as well as problems encountered in routine GC/MS analyses and the subsequent development of high performance liquid chromatography and LC/MS/MS methods for quantitation of DMSD.

Rutz, Jeffrey A.↗

Discovery and Identification of Dimethylsilanediol as a Contaminant in ISS Potable Water

In September 2010, analysis of ISS potable water samples was undertaken to determine the contaminant(s) responsible for a rise of total organic carbon (TOC) in the Water Processor Assembly (WPA) product water. As analysis of the routine target list of organic compounds did not reveal the contaminant, efforts to look for unknown compounds were initiated, resulting in discovery of an unknown peak in the gas chromatography/mass spectrometry (GC/MS) analysis for glycols. A mass spectrum of the contaminant was then generated by concentrating one of the samples and analyzing it by GC/MS in full-scan mode. Although a computer match of the compound identity could not be obtained with the instrument database, a search with a more up-to-date mass spectral library yielded a good match with dimethylsilanediol (DMSD). Inductively coupled plasma/mass spectrometry (ICP/MS) analyses showed abnormally high silicon levels in the samples, confirming that the unknown compound(s) contained silicon. DMSD was then synthesized to confirm the identification and provide a standard to develop a calibration curve. Further confirmation was provided by external direct analysis in real time time of flight (DART TOF) mass spectrometry. To routinely test for DMSD in the future, a quantitative method was needed. A preliminary GC/MS method was developed and archived samples from various locations on ISS were analyzed to determine the extent of the contamination and provide data for troubleshooting. This paper describes these events in more detail as well as problems encountered in routine GC/MS analyses and the subsequent development of high performance liquid chromatography and LC/MS/MS methods for measuring DMSD.

Rutz, Jeffrey A.↗

Neutron and Photon Background Measurements at the Spallation Neutron Source Facility - Paper 67

The Spallation Neutron Source facility is a short-pulsed spallation source for condensed matter research using slow neutron scattering. Neutron beams with useful energies ranging from 0.1 meV to 10 eV are brought from a target-moderator-reflector assembly down neutron beamlines to scatter from a variety of materials under study. As of early 2014, SNS routinely provides 1.4 MW (time-averaged) proton power at around 940 MeV to a mercury spallation target at 60 Hz in sub-microsecond pulses. In nearly all cases, the pulsed nature of the neutron source is used, via time-of-flight techniques, to precisely identify the energy of each neutron detected. These neutrons are frequently of such low energy, and consequent slow velocity, that they are not detected until several additional accelerator pulses have taken place. A time-dependent background feature, commonly called the 'prompt pulse,' can contaminate the recorded data. This prompt pulse arises in part from fast and high-energy neutrons and photons produced during the various source reactions, and appears at the same apparent time as the proton pulse striking the target (that is, with negligible time-of-flight delay), often obscuring the data of interest in the individual experiment. We describe here measurements of the fast and high-energy neutron and photon background around the SNS neutron scattering instruments appearing in time with the SNS accelerator pulse structure. Our measurements to date indicate that the liquid scintillator array we have deployed can satisfactorily function in the SNS environment and provide neutron-photon discriminated time/energy spectra of background sources contribution to observed, problematic SNS scattering instrument backgrounds. We will continue measurements and analysis to provide unfolded neutron energy spectra, and through longitudinal studies correlate observed changes in those spectra to external changes at SNS. (authors)

43 PARTICLE ACCELERATORS↗

SU-E-T-238: Deriving Electron Contamination Spectra From Pure and Clinical Photon Beams

Purpose: To extract the electron contamination energy spectra for an Elekta Precise Linac, based on pure photon and measured clinical beam percentage depth dose data. And to include this as an additional source in isource 4 in DOSXYZnrc. Methods: A pure photon beam was simulated for the Linac using isource 4 in the DOSXYZnrc Monte Carlo (MC) code. Percentage depth dose (PDD) data were extracted afterwards for a range of field sizes (FS). These simulated dose data were compared to actual measured dose PDD data, with the data normalized at 10 cm depth. The resulting PDD data resembled the electron contamination depth dose. Since the dose fall-off is a strictly decreasing function, a method was adopted to derive the contamination electron spectrum. Afterwards this spectrum was used in a DOSXYZnrc MC simulation run to verify that the original electron depth dose could be replicated. Results: Various square aperture FS’s for 6, 8 and 15 megavolt (MV) photon beams were modeled, simulated and compared to their respective actual measured PDD data. As FS increased, simulated pure photon depth-dose profiles shifted deeper, thus requiring electron contamination to increase the surface dose. The percentage of electron weight increased with increase in FS. For a FS of 15×15 cm{sup 2}, the percentage electron weight is 0.1%, 0.2% and 0.4% for 6, 8 and 15 MV beams respectively. Conclusion: From the PDD results obtained, an additional electron contamination source was added to the photon source model so that simulation and measured PDD data could match within 2 % / 2 mm gamma-index criteria. The improved source model could assure more accurate simulations of surface doses. This research project was funded by the South African Medical Research Council (MRC) with funds from National Treasury under its Economic Competitiveness and Support package.

60 APPLIED LIFE SCIENCES↗

Contamination from Skylab as determined from the solar coronagraph data

The white light solar coronagraph was one of the scientific telescopes flown on Skylab to study the sun. It studied the sun's atmosphere located from 0.5 to 5.0 solar radii above the sun's limb. Such a telescope is so sensitive to contamination around the spacecraft that it caused a major contamination abatement program to be initiated at the conception of Skylab. The coronagraph's data is analyzed showing the successfulness of that abatement program.

Mcguire, J. P.↗

Data and Model-Driven Decision Support for Environmental Management of a Chromium Plume at Los Alamos National Laboratory - 13264

A series of site investigations and decision-support analyses have been performed related to a chromium plume in the regional aquifer beneath the Los Alamos National Laboratory (LANL). Based on the collected data and site information, alternative conceptual and numerical models representing governing subsurface processes with different complexity and resolution have been developed. The current conceptual model is supported by multiple lines of evidence based on comprehensive analyses of the available data and modeling results. The model is applied for decision-support analyses related to estimation of contaminant- arrival locations and chromium mass flux reaching the regional aquifer, and to optimization of a site monitoring-well network. Plume characterization is a challenging and non-unique problem because multiple models and contamination scenarios are consistent with the site data and conceptual knowledge. To solve this complex problem, an advanced methodology based on model calibration and uncertainty quantification has been developed within the computational framework MADS (http://mads.lanl.gov). This work implements high-performance computing and novel, efficient and robust model analysis techniques for optimization and uncertainty quantification (ABAGUS, Squads, multi-try (multi-start) techniques), which allow for solving problems with large degrees of freedom. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sandia Hyperspectral Upper-Bound Spectrum Version 1.0

The Sandia hyperspectral upper-bound spectrum algorithm (hyper-UBS) is a cosmic ray despiking algorithm for hyperspectral data sets. When naturally-occurring, high-energy (gigaelectronvolt) cosmic rays impact the earth’s atmosphere, they create an avalanche of secondary particles which will register as a large, positive spike on any spectroscopic detector they hit. Cosmic ray spikes are therefore an unavoidable spectroscopic contaminant which can interfere with subsequent analysis. A variety of cosmic ray despiking algorithms already exist and can potentially be applied to hyperspectral data matrices, most notably the upper-bound spectrum data matrices (UBS-DM) algorithm by Dongmao Zhang and Dor Ben-Amotz which served as the basis for the hyper-UBS algorithm. However, the existing algorithms either cannot be applied to hyperspectral data, require information that is not always available, introduce undesired spectral bias, or have otherwise limited effectiveness for some experimentally relevant conditions. Hyper-UBS is more effective at removing a wider variety of cosmic ray spikes from hyperspectral data without introducing undesired spectral bias. In addition to the core algorithm the Sandia hyper-UBS software package includes additional source code useful in evaluating the effectiveness of the hyper-UBS algorithm. The accompanying source code includes code to generate simulated hyperspectral data contaminated by cosmic ray spikes, several existing despiking algorithms, and code to evaluate the performance of the despiking algorithms on simulated data.

Anthony, Stephen↗