Self-sterilizing polymers

Addition of approximately 1% paraformaldehyde to room-temperature-vulcanizing potting polymer results in effective, controllable germicide. When heated above ambient temperatures, paraformaldehyde releases dry formaldehyde, which can penetrate enclosed areas and packages, will not damage material, and leaves no permanent residue.

Tulis, J. J.↗

Motorized Cyrogenic Valve

Remotely-controlled cryogenic valve operates over temperature range from room temperature to 2 K. Valve used in helium dilution refrigerators, cryostats and adiabatic-demagnetization refrigerators.

Salerno, L.↗

Space Operations for a New Era of Exploration Launch Vehicles

NASA's Constellation Program is depending on the Ares Projects to deliver the crew and cargo launch capabilities needed to send human explorers to the Moon and beyond. Ares I and V will provide the core space launch capabilities needed to continue providing crew and cargo access to the International Space Station (ISS), and to build upon the U.S. history of human space exploration. Since 2005, Ares has made substantial progress on designing, developing, and testing the Ares I crew launch vehicle and has continued its in-depth studies of the Ares V cargo launch vehicles. The combined Ares I/Ares V architecture has been designed to reduce the complexity and labor intensity of ground operations for America's next journeys beyond low-Earth orbit (LEO). A deliberate effort is being made to ensure a high level of system operability to significantly increase safety and system availability as well as reduce recurring costs for this new launch vehicle. The Ares Projects goal is to instill operability as part of the vehicles requirements development, design, and operations. This simplicity will come from using simpler, proven engine designs, as in the case of the J-2X upper stage engine and RS-68 engine; improving existing hardware, as in the case of the Shuttle-heritage 5-segment solid rocket motor; and using common propulsion and instrument unit elements between Ares I and Ares V. Furthermore, lessons learned while developing Ares I will be applied directly to Ares V operations. In 2009, the Ares Projects plan to conduct the first flight test of Ares I, designated Ares I-X. Ares I-X preparations have already prompted changes to the vehicle stacking and launch infrastructure at Kennedy Space Center (KSC), including removing Shuttle-specific fixtures from the Vehicle Assembly Building (VAB) to accommodate Ares I-style stacking operations, new firing room computers and infrastructure in the VAB Launch Control Center, and new lightning protection system towers at Launch Complex 39B to accommodate the greater height of Ares I-X. In addition to lessons learned from the stacking of Ares I-X, the flight test itself promises to yield important data and operations lessons for assembling, launching, and flying Ares I.

Cook, Stephen A.↗

Qualification and Selection of Flight Diode Lasers for Space Applications

The reliability and lifetime of laser diodes is critical to space missions. The Nuclear Spectroscopic Telescope Array (NuSTAR) mission includes a metrology system that is based upon laser diodes. An operational test facility has been developed to qualify and select, by mission standards, laser diodes that will survive the intended space environment and mission lifetime. The facility is situated in an electrostatic discharge (ESD) certified clean-room and consist of an enclosed temperature-controlled stage that can accommodate up to 20 laser diodes. The facility is designed to characterize a single laser diode, in addition to conducting laser lifetime testing on up to 20 laser diodes simultaneously. A standard laser current driver is used to drive a single laser diode. Laser diode current, voltage, power, and wavelength are measured for each laser diode, and a method of selecting the most adequate laser diodes for space deployment is implemented. The method consists of creating histograms of laser threshold currents, powers at a designated current, and wavelengths at designated power. From these histograms, the laser diodes that illustrate a performance that is outside the normal are rejected and the remaining lasers are considered spaceborne candidates. To perform laser lifetime testing, the facility is equipped with 20 custom laser drivers that were designed and built by California Institute of Technology specifically to drive NuSTAR metrology lasers. The laser drivers can be operated in constant-current mode or alternating-current mode. Situated inside the enclosure, in front of the laser diodes, are 20 power-meter heads to record laser power throughout the duration of lifetime testing. Prior to connecting a laser diode to the current source for characterization and lifetime testing, a background program is initiated to collect current, voltage, and resistance. This backstage data collection enables the operational test facility to have full laser diode traceablity.

Liebe, Carl C.↗

Amorphous Insulator Films With Controllable Properties

In experiments described in report, amorphous hydrogenated carbon films grown at room temperature by low-frequency plasma deposition, using methane or butane gas. Films have unique array of useful properties; (a) adhere to wide variety of materials; (b) contain only carbon and hydrogen; (c) smooth and free of pinholes; (d) resistant to attack by moisture and chemicals; and (e) have high electric-breakdown strength and electrical resistivity. Two of optical properties and hardness of this film controlled by deposition conditions. Amorphous a-C:H and BN films used for hermetic sealing and protection of optical, electronic, magnetic, or delicate mechanical systems, and for semiconductor field dielectrics.

Alterovitz, Samuel A.↗

Temperature-Controlling Circuit

Simple circuit switches current to electrical heater on and off to maintain temperature of room at 25 plus or minus 0.5 degree C. Lightweight, compact, reliable, insensitive to electrical noise, and uses single 5-Vdc power supply. Handles ac loads of 10 A. Designed to operate outside temperature controlled environment over range of -55 to +85 degree C. Thermistor provides input signal for simple temperature controller. Output of controller applied to solid-state relay, which in turn switches current to resistance heater.

Temple, Gerald↗

High temperature, low-cycle fatigue of copper-base alloys for rocket nozzles. Part 2: Strainrange partitioning and low-cycle fatigue results at 538 deg C

Low-cycle fatigue tests of 1/2 Hard AMZIRC Copper and NARloy Z were performed in argon at 538 C to determine partitioned strain range versus life relationships. Strain-controlled low-cycle fatigue tests of a Zr-Cr-Mg copper-base alloy were also performed. Strain ranges, lower than those employed in previous tests, were imposed in order to extend the fatigue life curve out to approximately 400,000 cycles. An experimental copper alloy and an experimental silver alloy were also studied. Tensile tests were performed in air at room temperature and in argon at 538 C. Strain-controlled low-cycle fatigue tests were performed at 538 C in argon to define the fatigue life over the regime from 300 to 3,000 cycles. For the silver alloy, three additional heat treatments were introduced, and a limited evaluation of the short-term tensile and low-cycle fatigue behavior at 538 C was performed.

Conway, J. B.↗

Effects of thermal cycling on residual mechanical properties of C6000/PMR-15 graphite polyimide

An experimental study to determine the effects of thermal cycling on residual mechanical properties of a graphite/polyimide composite has been conducted. Interlaminar shear, flexure and compression strengths were measured at room temperature and 316 C on unidirectional and quasi-isotropic laminates subjected to 150 and 500 thermal cycles between -156 C and 316 C. Thermal cycling produced transverse microcracks and delaminations in the laminates. The linear density of the microcracks (35/cm) was about the same after 150 and 500 cycles. Although the crack density did not change from 150 to 500 cycles, crack growth did occur with intralamina cracks growing into adjacent lamina. The matrix controlled properties of the quasi-isotropic laminate at both room temperature and 316 C were significantly reduced by thermal cycling. However, the properties of the unidirectional laminate were significantly reduced only at 316 C.

Tompkins, S. S.↗

Control of dielectric film deposition

Airgap capacitor in deposition chamber is used to monitor deposition. Coating process is completely uniform over edges, points, and internal areas. Areas not requiring coating can be marked. Since deposition process is accomplished at or near room temperature, there is no risk of thermal damage to coated components. With control method, deposition material is fully utilized and no excess coating is necessary to insure protection of coated parts.

Graebner, E. C.↗

Microstructure, strength, and oxidation of a 10 wt pct zyttrite-Si3N4 ceramic

Hot pressed Si3N4 doped with 10 wt pct zyttrite as a sintering aid was studied. An equiaxed, fine grained microstructure was predominant, with no apparent porosity. Bend strengths were determined at room temperature and high temperatures (up to 1370 C). Oxidation was measured by weight gain at 1370 C in air. The resulting material exhibited very good room temperature strength (755 MPa). The work showed that room temperature strength can be improved significantly by using controlled Si3N4 powder with 10 wt pct zyttrite. High temperature strength (514 MPa) at 1370 C was nearly double that of hot-pressed Si3N4 (NC-132). The oxidation resistance at 1370 C was also higher than that of NC-132.

Dutta, S.↗

Results of inphase axial-torsional fatigue experiments on 304 stainless steel

A series of axial-torsional, inphase, strain-controlled, low-cycle fatigue tests were performed at room temperature on tubular specimens of 304 stainless steel. The program was conducted in cooperation with the task group on multiaxial fatigue research of ASTM committee E-09. The objective was to quantify the variability in multiaxial test results among several laboratories. Only included is data which was generated at the NASA Lewis Research Center's High Temperature Fatigue and Structures Laboratory. The experimental equipment and procedures used are described. The tubular specimens were polished on the outer surface to aid in the use of a cellulose film surface replication technique for crack detection. However, cracking initiated predominantly on the internal surface for all specimens. Honing of the bore of the tubular specimens lessened but did not entirely eliminate this problem. The observed fatigue lives are compared with lives calculated from three multiaxial life models. Constants for the life prediction models were obtained from uniaxial and torsional tests performed on the same heat of material. The observed fatigue lives agreed with calculated lives to within a factor of two for all but one of the life prediction models.

Bonacuse, Peter J.↗

Hindlimb unloading rodent model: technical aspects

Since its inception at the National Aeronautics and Space Administration (NASA) Ames Research Center in the mid-1970s, many laboratories around the world have used the rat hindlimb unloading model to simulate weightlessness and to study various aspects of musculoskeletal loading. In this model, the hindlimbs of rodents are elevated to produce a 30 degrees head-down tilt, which results in a cephalad fluid shift and avoids weightbearing by the hindquarters. Although several reviews have described scientific results obtained with this model, this is the first review to focus on the technical aspects of hindlimb unloading. This review includes a history of the technique, a brief comparison with spaceflight data, technical details, extension of the model to mice, and other important technical considerations (e.g., housing, room temperature, unloading angle, the potential need for multiple control groups, age, body weight, the use of the forelimb tissues as internal controls, and when to remove animals from experiments). This paper is intended as a reference for researchers, reviewers of manuscripts, and institutional animal care and use committees. Over 800 references, related to the hindlimb unloading model, can be accessed via the electronic version of this article.

NASA Discipline Musculoskeletal↗

Acoustic Calibration of the Exterior Effects Room at the NASA Langley Research Center

The Exterior Effects Room (EER) at the NASA Langley Research Center is a 39-seat auditorium built for psychoacoustic studies of aircraft community noise. The original reproduction system employed monaural playback and hence lacked sound localization capability. In an effort to more closely recreate field test conditions, a significant upgrade was undertaken to allow simulation of a three-dimensional audio and visual environment. The 3D audio system consists of 27 mid and high frequency satellite speakers and 4 subwoofers, driven by a real-time audio server running an implementation of Vector Base Amplitude Panning. The audio server is part of a larger simulation system, which controls the audio and visual presentation of recorded and synthesized aircraft flyovers. The focus of this work is on the calibration of the 3D audio system, including gains used in the amplitude panning algorithm, speaker equalization, and absolute gain control. Because the speakers are installed in an irregularly shaped room, the speaker equalization includes time delay and gain compensation due to different mounting distances from the focal point, filtering for color compensation due to different installations (half space, corner, baffled/unbaffled), and cross-over filtering.

Faller, Kenneth J., II↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

History and applications in controlled environments

The widespread application of electric (often called artificial) light in greenhouses, growing rooms, and plant growth chambers would presuppose that the role of phytochrome would be considered in the selection and use of such lighting systems. Unfortunately this is not usually the case. Part of the problem is that many students, and indeed an unfortunate number of senior scientists, seem to regard phytochrome as a laboratory phenomenon without much application in the real world. They simply have not grasped the concept that phytochrome is functioning through all stages of plant development, wherever plants are grown. It is certainly true, as Meijer (1971) stated, that one cannot compare experimental results obtained under very strict laboratory conditions with plant irradiation in glasshouses and in growth rooms. When Karl Norris developed the first practical portable spectroradiometer about 1962, some of the first measurements were to determine the red/far-red ratios under tree canopies. These measurements showed clearly the predominance of far-red in the understory and suggested that far-red was contributing to the elongation exhibited by many species growing in the shade, and possibly was a factor in the induction of light requirements in seeds. Subsequently we used Catalpa leaves as far-red filters to make light-insensitive lettuce seed light requiring. Much more detailed work has since been done on phytochrome effects in the natural environment, and it is encouraging to note that efforts are bring made to apply phytochrome research to horticulture.

Downs, R. J.↗