Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma modification through boron particulate injection in the full tungsten environment of WEST

Recent experiments have confirmed the compatibility of extended boron particulate injections with high performance plasma discharges in the full tungsten (W) environment of WEST. Utilizing an impurity powder dropper (IPD) equipped with boron (B) powders a series of extended experimental programs providing controlled injections have quantified plasma response to varying levels of injection rate and total injection quantity. Calibration of injection quantities confirmed through post-situ testing of the IPD and cross-correlated with both high-speed camera illumination and spectroscopic measurement have allowed for the first time a fine scale determination of the effects of powder introduction on plasma performance. Plasma enhancement, consistent with turbulence reduction through profile modification, has been observed with sustained increases in the stored energy (WMHD), by 18%, electron temperature (T e ) by 35%, and neutron rate (N n ) by up to 200%, all of which scale positively with increasing powder injection rates. These injections have also resulted in both prompt and extended reductions in native impurity content, decreases in post injection radiated power, and strong decreases in divertor deuterium signatures signifying a reduction in recycling suggesting enhanced boron layer formation which provides a reduction of source terms and leads to enhanced gettering of main ion and impurity sources.

Lunsford, R. [Princeton Plasma Physics Laboratory ↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings - Part 1

We are pleased to present starting with this volume of ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC), a series of peer-reviewed papers related to some of ongoing research projects and applications of Grid-interactive Efficient Buildings (GEBs). As part of a new program initiated by the Building Technology Office (BTO) with the US Department of Energy (DOE), GEBs are characterized as highly energy-efficient buildings that are equipped with smart technologies and distributed energy resources that can be dynamically controlled to meet grid needs and minimize electricity system costs, while meeting occupants’ comfort and productivity requirements. In simple terms,DOE defines GEBs as efficient, connected, smart, and flexible buildings. The GEB technologies touch on the main topical areas of JESBC aimed at fostering sustainable buildings and cities by providing results of evaluation studies and demonstration projects. Indeed, one of the main goals for JESBC is to disseminate solutions to enhance the built environment energy efficiencies, low carbon services, inter-connectivity services, resilient multi-services, and healthy and comfortable living spaces.

buildings↗

Cooled Spray Technology for Particulate Reduction in a Heavy-Duty Engine

Cooled spray (CS) technology passively reduces particulate matter (PM) emissions from diesel engines compared to non-CS-equipped diesel engines. CS inserts are mounted near the injector nozzle and control mixing so that the fuel and air can premix while limiting combustion near fuel-rich zones, thereby reducing the formation of particulate matter. CS components contain no moving parts and could be installed as a retrofit or built into new engines. However, CS technology is early in its development, and further investigations are needed to understand the overall performance implications and practicality of the technology. In this paper, we investigate several important aspects of CS, providing a clearer picture of some challenges and potential benefits of CS. Two alignment techniques are used to characterize measurement ease and bias, namely, an optical alignment and spray-plug impact alignment. While the optical technique facilitates alignment more easily, a bias was measured between the optical and spray-plug techniques, suggesting the optical technique may have insufficient accuracy without additional corrections. We also evaluate the engine performance of a well-aligned and poorly aligned CS insert, compared to the baseline configuration. The poorly aligned insert shows slower combustion than the baseline and mixed overall performance. However, the well-aligned insert shows faster combustion than the baseline and PM emission reduction at most operating conditions, with some conditions showing PM reduction up to 80%. Furthermore, the results of this paper highlight the alignment challenges of CS technology as well as the potential PM reduction benefit of the technology.

33 ADVANCED PROPULSION SYSTEMS↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Optimal Operation of a Hybrid Hydraulic Electric Architecture (HHEA) for Off-Road Vehicles Over Discrete Operating Decisions

Many off-highway machines including construction and agriculture equipment use hydraulics for power transmission and throttling as a means for control. Trends towards better efficiency and electrification have led to the creation of a novel Hybrid Hydraulic-Electric Architecture (HHEA) which could significantly reduce energy consumption and maintain control performance, even in machines that are too large to be directly electrified. This is achieved by using a set of common pressure rails to transmit the majority of power via power dense hydraulics and modulating the power with small electric motor-drives to achieve precise control. This paper proposes a computationally efficient method for computing the optimal sequence of pressure rail selections for the HHEA over finite drive cycles. This is useful for fairly comparing the novel architecture’s energy performance to existing architectures and for use in iterative optimal design of the architecture. The optimal control technique makes use of a static model of the architecture and losses. Constraints are enforced such that the drive cycle is repeatable. The constrained optimal operation is solved using a Lagrange multiplier technique that transforms the optimization into a small set of sub-problems by considering combinations of active constraints. Each of these sub-problems can be solved efficiently because loss calculations for all time steps can be computed in parallel. A case study of an off-road construction machine demon-strates that the HHEA reduces energy consumption by 2/3 compared to the baseline load sensing architecture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 8: Agricultural Use

Biochar has potential to reduce the environmental footprint in nearly every aspect of agricultural production. The use of biochar has been proposed to manage agricultural biomass (reference), to process animal manure and poultry litter (reference), to improve the nutritive value of feed (reference), and to mitigate the offsite movement of pesticides (reference) and soil nutrients (reference). The coproducts of biochar production hold similar potential. For example, on farm production of biochar can provide bioenergy to heat greenhouses and barns and to power farm equipment (reference). Pyroligneous acid, a coproduct of pyrolysis, has the ability to control fungal pathogens and deter pathogenic insects (reference). Although these environmental benefits are potentially substantial, their on-farm use has not been widely studied. Furthermore, the on-farm installation of biochar production facilities presents challenges that reduce the feasibility of co-production scenarios (Phillips 2018). As such, this section primarily addresses the application of biochar to agricultural soils.

agriculture↗

Moving from Information Assurance to Functional Assurance with Engineered Controls

Cyber threats to operational technology demand more than traditional IT defenses—they require full-spectrum mission assurance. Cyber-Informed Engineering (CIE) is an approach that embeds engineered controls into system design to ensure critical functions remain safe and reliable, even under attack. Unlike conventional cybersecurity tools, engineered controls act directly on physical processes to prevent unacceptable outcomes such as equipment damage or mission failure. This session will outline the CIE framework and share examples of consequence-based design that deliver true resilience, not just fail-safe behaviors. Attendees will learn how to integrate these principles into the engineering lifecycle to support resilient-by-design architectures and inform emerging standards. This talk sets the stage for the panel discussion on advancing CIE across sectors as digital and physical systems converge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Data Science and Machine Learning Platform Supporting Large Particle Accelerator Control and Diagnostics Applications Final Report: SBIR Initial Phase II DE-SC0022583

The Machine Learning Data Platform (MLDP) is a product providing full-stack support for data science, Machine Learning, and Artificial Intelligence (ML/AI) applications at particle accelerator and large experimental physics facilities. It supports ML/AI applications from front-end, high-speed acquisition of heterogeneous, time-series data, through data archiving and management, to back-end analysis. The MLDP embodies a “data-science ready” platform for data analysis and ML/AI applications in diagnosis, modelling, control, and optimization of these facilities. It provides data scientists and applications a consistent, datacentric interface to archive data standardizing implementation and deployment of ML/AI algorithms to different operations configurations within the same facility, or between facilities. Being an open-source, public-domain project, the MLDP is intended for broadest possible impact by increasing accessibility and minimizing the required expertise for installation and operation. The MLDP can also be deployed at user facilities for experimental data collection, archiving, and analysis. It is capable of acquisition and archiving of heterogeneous data from experimental equipment (e.g., images, arrays, structures, etc.) along with system hardware configurations (e.g., scalars, tables), control system process variables, and any metadata required for provenance. Thus, the MLDP can manage experimental data through its entire lifecycle, from acquisition and archiving, through analysis and investigation, to release and final publication.

43 PARTICLE ACCELERATORS↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

Are low-cost sensors good enough for IAQ controls?

This study used laboratory testing to evaluate low-cost (about $\$ 200$ US) IAQ monitors that measured PM2.5 to determine if they are suitable for controlling IAQ for ventilation or air cleaning systems. Current Indoor Air Quality (IAQ) standards and approaches to minimizing pollutants depend almost exclusively on using dilution with outdoor air for some generic, continuously generated contaminant (e.g., ASHRAE Standard 62.2-2016). Some standards include measurement of CO 2 (e.g., EN 13779 standard (CEN, 2007) and NEN 8088 (NEN, 2011)) – however this is not because CO 2 itself is a pollutant of concern, but rather because it can be used as an occupancy indicator or as something that correlates with bioeffluents. Ideally, we would like to measure contaminant concentrations directly and ventilate to control their concentration within acceptable limits. This would ensure that concentrations do not got too high (as they can if emission rates exceed our assumptions) and also allow for ventilation reductions, and resulting energy savings, if concentrations are low. Until recently, it was impractical to consider direct contaminant control in residential (and many commercial) spaces due to the high cost and maintenance requirements for monitoring equipment. In the past couple of years low-cost sensors have been developed for some contaminants of concern – the greatest example of which is for particles. These sensors have been incorporated into low-cost (<$250 US) IAQ monitors. Finally, this has opened up the possibility of direct control of ventilation (and filtration systems) by sensing particles. However, it is important to evaluate these monitors to determine if their results are sufficiently good to control a ventilation system.

47 OTHER INSTRUMENTATION↗

Cyber Secure Sensor Network for Fossil Fuel Power Generation Assets Monitoring

The energy sector is undergoing digital transformation which is to say more and more power generation assets have become automated and connected to the internet. The connected sensors can tap into plants to monitor the health of assets and manage fleets remotely. These are just some of the benefits digitalization is bringing to the power industry. Within a power plant, control systems are no longer concerned with one system or one piece of equipment, but rather whole fleet of assets inter-connected with smart sensors which have the function of continuously monitoring and transmitting real-time operational data to operators. These connected systems will form a part of the industrial internet of things (IIoT). The big data scenarios provide benefits of performing system prognostics and optimization which is a key selling point of power plant digitalization.

20 FOSSIL-FUELED POWER PLANTS↗

Development of PNNL’s Plutonium Metallography Capability

The goal of this project was to develop plutonium metallography capabilities and establish workflows for characterization at PNNL’s Radiological Processing Facility (RPL). Developing and expanding on this capability opens more opportunities for PNNL to better support science through collaborations with other labs, plants, and sites withing the Department of Energy Complex and through programs within the National Nuclear Security Administration. This project established metallography equipment in an air glovebox, polishing protocols, as well as radiological and facility controls and procedures so that gram quantities of plutonium metal could be analyzed on multiple characterization tools. Data was collected and analyzed on two different delta phase plutonium - Gallium samples and a calciothermically reduced alpha plutonium metal using a combination of optical and electron microscopy, powder X-ray diffraction, and atom probe tomography. This report highlights the metallography capabilities, some preliminary data collections, and plans at PNNL to support plutonium material science.

36 MATERIALS SCIENCE↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trepanning Graphite Samples at a Shutdown Magnox Reactor: A US-UK Joint Exercise for Nuclear Verification

In April 2022, a team sponsored by the US DOE Office of Nuclear Verification (ONV) shipped trepanning equipment to the nuclear power station at Trawsfynydd, Wales, UK to collect samples from the graphite moderator of Reactor 1. The sampling campaign to collect 48 graphite samples was completed in five weeks beginning July 11. Half the samples will be analyzed in the US to determine the total energy production of the facility. The other half will be analyzed by Magnox Ltd. to support decisions for options for the ultimate decommissioning path for the facility. This paper provides a description of the equipment and the operations required to trepan, collect, and package the samples while controlling the small amounts of radioactive graphite dust entrained on and within the tool. The most important sample parameter needed is the precise location of the sample, to within ±6 mm in a fuel channel, while the tool is deployed to between 12 and 20 meters below the operations floor; our means of achieving this precision is given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Methane Emissions Produced by Pneumatic Devices and Produced Water Tanks on Natural Gas Wellsites

In recent years, more scrutiny has been placed on the release of greenhouse gasses (GHGs) by the oil and gas industry in North America as climate concerns increase. In the coming years, stricter regulations proposed by the Environmental Protection Agency (EPA) concerning the release of GHGs will further direct attention to GHG emissions quantification, modeling, and overall reduction. Active natural gas wellsites employ production equipment that routinely emits methane during normal operation. Production equipment often includes, but is not limited to, gas production units (GPUs), pneumatic controllers (PCs) and actuators powered by produced natural gas, and produced water storage tanks. This work details direct methane emission measurements taken at active natural gas wellsites originating from intermittent pneumatic controllers and produced water storage tanks. Efforts to model methane flows originating from these sources are also detailed, and those results are compared to direct measurement. The direct methane emissions measurement campaign collected flow data from two active dry wellsites in the Marcellus shale region. These measurement campaigns captured, in total, several weeks of continuous data from these sites. Data included multiple pneumatic device vent flowrate channels, a single channel monitoring total emissions vented from the produced water storage tanks, and corresponding site weather data. Periodic composition measurements were taken from flows vented from produced water tanks. Computational modeling efforts attempted to mimic a given site’s methane emissions behavior given limited input parameters. Direct measurement data and simulation data yielded, through reduction and analysis, apparent methane emissions factors, statistics on pneumatic device actuation events, important relationships between GPU parameters and pneumatic device actuation events, produced water storage tank vent flows and flow compositions, and parameters most contributing to the magnitude and frequency of these fugitive methane emissions. Measurements, considering data from a 72hr period, produced PC emissions factors from 0.008 to 0.03 SCFH per device with an average device emitting 0.026 SCFH at the first site. The second site produced PC emissions factors spanning from 0.05 to 25.47 SCFH with an average device emitting 1.93 SCFH not including the 25.47 SCFH device, which was assumed to be malfunctioning. Two unique water tank emission measurements were made, 618 g CH4 per hour and 32.6 g CH4 per hour. On a water basis, the water tank emissions factors were 0.66 and 0.042 kg CH4 per bbl of water, respectively.

03 NATURAL GAS↗