At least 289 records · Page 16

H Diffusion in Olivine and Pyroxene from Peridotite Xenoliths and a Hawaiian Magma Speedometer

Hydrogen is present as a trace element in olivine and pyroxene and its content distribution in the mantle results from melting and metasomatic processes. Here we examine how these H contents can be disturbed during decompression. Hydrogen was analyzed by FTIR in olivine and pyroxene of spinel peridotite xenoliths from Salt Lake Crater (SLC) nephelinites which are part of the rejuvenated volcanism at Oahu (Hawaii) [1,2]. H mobility in pyroxene resulting from spinel exsolution during mantle upwelling Most pyroxenes in SLC peridotites exhibit exsolutions, characterized by spinel inclusions. Pyroxene edges where no exsolution are present have less H then their core near the spinel. Given that H does not enter spinel [3], subsolidus requilibration may have concentrated H in the pyroxene adjacent to the spinel exsolution during mantle upwelling. H diffusion in olivine during xenolith transport by its host magma and host magma ascent rates Olivines have lower water contents at the edge and near fractures compared to at their core, while the concentrations of all other chemical elements appear homogeneous. This suggests that some of the initial water has diffused out of the olivine. Water loss from the olivine is thought to occur during host-magma ascent and xenolith transport to the surface [4-6]. Diffusion modeling matches best the data when the initial water content used is that measured at the core of the olivines, implying that mantle water contents are preserved at the core of the olivines. The 3225 cm(sup -1) OH band at times varies independantly of other OH bands, suggesting uneven H distribution in olivine defects likely acquired during mantle metasomatism just prior to eruption and unequilibrated. Diffusion times (1-48 hrs) combined with depths of peridotite equilibration or of magma start of degassing allow to calculate ascent rates for the host nephelinite of 0.1 to 27 m/s.

Peslier, A. H.↗

Sims Analysis of Water Abundance and Hydrogen Isotope in Lunar Highland Plagioclase

The detection of indigenous water in mare basaltic glass beads has challenged the view established since the Apollo era of a "dry" Moon. Since this discovery, measurements of water in lunar apatite, olivine-hosted melt inclusions, agglutinates, and nominally anhydrous minerals have confirmed that lunar igneous materials contain water, implying that some parts of lunar mantle may have as much water as Earth's upper mantle. The interpretation of hydrogen (H) isotopes in lunar samples, however, is controversial. The large variation of H isotope ratios in lunar apatite (delta Deuterium = -202 to +1010 per mille) has been taken as evidence that water in the lunar interior comes from the lunar mantle, solar wind protons, and/or comets. The very low deuterium/H ratios in lunar agglutinates indicate that solar wind protons have contributed to their hydrogen content. Conversely, H isotopes in lunar volcanic glass beads and olivine-hosted melt inclusions being similar to those of common terrestrial igneous rocks, suggest a common origin for water in both Earth and Moon. Lunar water could be inherited from carbonaceous chondrites, consistent with the model of late accretion of chondrite-type materials to the Moon as proposed by. One complication about the sources of lunar water, is that geologic processes (e.g., late accretion and magmatic degassing) may have modified the H isotope signatures of lunar materials. Recent FTIR analyses have shown that plagioclases in lunar ferroan anorthosite contain approximately 6 ppm H2O. So far, ferroan anorthosite is the only available lithology that is believed to be a primary product of the lunar magma ocean (LMO). A possible consequence is that the LMO could have contained up to approximately 320 ppm H2O. Here we examine the possible sources of water in the LMO through measurements of water abundances and H isotopes in plagioclase of two ferroan anorthosites and one troctolite from lunar highlands.

Hui, Hejiu↗

Failure Analysis Results and Corrective Actions Implemented for the Extravehicular Mobility Unit 3011 Water in the Helmet Mishap

Water entered the Extravehicular Mobility Unit (EMU) helmet during extravehicular activity (EVA) no. 23 aboard the International Space Station on July 16, 2013, resulting in the termination of the EVA approximately 1 hour after it began. It was estimated that 1.5 liters of water had migrated up the ventilation loop into the helmet, adversely impacting the astronaut's hearing, vision, and verbal communication. Subsequent on-board testing and ground-based test, tear-down, and evaluation of the affected EMU hardware components determined that the proximate cause of the mishap was blockage of all water separator drum holes with a mixture of silica and silicates. The blockages caused a failure of the water separator degassing function, which resulted in EMU cooling water spilling into the ventilation loop, migrating around the circulating fan, and ultimately pushing into the helmet. The root cause of the failure was determined to be ground-processing shortcomings of the Airlock Cooling Loop Recovery (ALCLR) Ion Filter Beds, which led to various levels of contaminants being introduced into the filters before they left the ground. Those contaminants were thereafter introduced into the EMU hardware on-orbit during ALCLR scrubbing operations. This paper summarizes the failure analysis results along with identified process, hardware, and operational corrective actions that were implemented as a result of findings from this investigation.

Steele, John↗

Development and Capabilities of ISS Flow Boiling and Condensation Experiment

An experimental facility to perform flow boiling and condensation experiments in long duration microgravity environment is being designed for operation on the International Space Station (ISS). This work describes the design of the subsystems of the FBCE including the Fluid subsystem modules, data acquisition, controls, and diagnostics. Subsystems and components are designed within the constraints of the ISS Fluid Integrated Rack in terms of power availability, cooling capability, mass and volume, and most importantly the safety requirements. In this work we present the results of ground-based performance testing of the FBCE subsystem modules and test module which consist of the two condensation modules and the flow boiling module. During this testing, we evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, heat loss from different modules and components, and performance of the test modules. These results will be used in the refinement of the flight system design and build-up of the FBCE which is manifested for flight in late 2017-early 2018.

microgravity↗

Fractal Loop Heat Pipe Performance Comparisons of a Soda Lime Glass and Compressed Carbon Foam Wick

This study compares heat flux performance of a Loop Heat Pipe (LHP) wick structure fabricated from compressed carbon foam with that of a wick structure fabricated from sintered soda lime glass. Each wick was used in an LHP containing a fractal based evaporator. The Fractal Loop Heat Pipe (FLHP) was designed and manufactured by Mikros Manufacturing Inc. The compressed carbon foam wick structure was manufactured by ERG Aerospace Inc., and machined to specifications comparable to that of the initial soda lime glass wick structure. Machining of the compressed foam as well as performance testing was conducted at the United States Naval Academy. Performance testing with the sintered soda lime glass wick structures was conducted at NASA Goddard Space Flight Center. Heat input for both wick structures was supplied via cartridge heaters mounted in a copper block. The copper heater block was placed in contact with the FLHP evaporator which had a circular cross-sectional area of 0.88 cm(sup 2). Twice distilled, deionized water was used as the working fluid in both sets of experiments. Thermal performance data was obtained for three different Condenser/Subcooler temperatures under degassed conditions. Both wicks demonstrated comparable heat flux performance with a maximum of 75 W/cm observed for the soda lime glass wick and 70 W /cm(sup 2) for the compressed carbon foam wick.

Myre, David↗

FTIR Analysis of Water in Pyroxene and Plagioclase in ALH 84001 and Nakhlites

Determining the volatile budget of the interior of Mars is crucial for our understanding of that planet's formation, geodynamics, cooling history and the origin of its volcanism and atmosphere as well as its potential for life. Surficial water is evident from spacecraft and rover data in polar caps and the atmosphere, in the presence of river channels, and in the detection of water-bearing minerals. Meteorites, however, are our best candidates for estimating the amount of water present at depth, even if all are crustal samples. The last 10 years have seen a blooming of studies measuring water and halogens in Martian meteorites. The bulk of these studies target phosphate, a typically late-stage phase in the igneous Martian meteorites that potentially would concentrate incompatible element hydrogen (H quantified traditionally as "water", i.e., H2O concentrations in weight) near the end of the crystallization sequence. However, determining the amount of water, F, and Cl in the magma from which a phosphate crystallized from is not straightforward and in most instances not possible. On the other hand, phosphates have turned out to be very useful in identifying hydrothermal processes that could have added water while or after the magma flowed and crystallized. Another caveat of analyzing Martian meteorite phases for water is that shocked phases such as maskelynite and impact melts appear to have incorporated water from the Martian atmosphere, as evidenced by high H isotope ((delta)D) signatures, and therefore their water concentrations cannot be interpreted in terms of deep planetary processes. The best candidates for estimating the water content of the Martian interior have been melt inclusions (glass or amphibole-bearing) which the enclosing mineral (usually olivine) would have prevented from exchanging volatiles with the surroundings after crystallization. Even some of these, however, have high (delta)D, meaning they were affected by H exchange via impact events or with crustal reservoirs or hydrothermal fluids. Here, nominally anhydrous minerals (pyroxene, olivine, plagioclase, or maskelynite) in orthopyroxenite ALH 84001 and selected nakhlites are analyzed for water and major elements, in order to determine 1) whether they contain any water; 2) if they do, what controls its distribution (crystallization, degassing, hydrothermal or impact processes); and 3) if any of these measurements can be used to infer the water contents of the parent magma and their mantle sources. A shock-reverberation experiment was also performed on terrestrial orthopyroxenes (opx) to simulate the heavily shocked conditions of ALH 84001 (> 31 GPa [17]).

Peslier, A. H.↗

Effects of Alternate Leading Edge Cutback on the Space Shuttle Main Engine Low Pressure Fuel Pump

A higher order cavitation oscillation observed in the SSME low pressure fuel pump has been eliminated in water flow testing of a modified subscale replica of the inducer. The low pressure pump was modified by removing the outboard sections of two opposing blades of the four-bladed inducer, blending the "cutback" regions into the blades at the leading edge and tip, and removing material on the suction sides to decrease the exposed leading edge thickness. The leading edge tips of the cutback blades were moved approximately 25 degrees from their previous locations, thereby increasing one blade to blade spacing, decreasing the second, while simultaneously moving the cutback tips downstream. The test was conducted in MSFC's inducer test loop at scaled operating conditions in degassed and filtered water. In addition to eliminating HOC across the entire scaled operating regime, rotating cavitation was suppressed while the range of both alternate blade and asymmetric cavitation were increased. These latter phenomena, and more significantly, the shifts between these cavitation modes also resulted in significant changes to the head coefficient at low cavitation numbers. Reverse flow was detected at a slightly larger flow coefficient with the cutback inducer and suction capability was reduced by approximately 1 velocity head at and above approximately 90% of the reference flow coefficient. These performance changes along with more intense reverse flow are consistent with poor flow area management and increased incidence in the cutback region. Although the test demonstrated that the inducer modification was successful at eliminating the higher order cavitation across the entire scaled operating regime, different, previously unobserved, cavitation oscillations were introduced and significant performance penalties were imposed.

Mulder, Andrew↗

Hydrogen in Martian Meteorites

Most volatile studies of Mars have targeted its surface via spacecraft and rover data, and have evidenced surficial water in polar caps and the atmosphere, in the presence of river channels, and in the detection of water bearing minerals. The other focus of Martian volatile studies has been on Martian meteorites which are all from its crust. Most of these studies are on hydrous phases like apatite, a late-stage phase, i.e. crystallizing near the end of the differentiation sequence of Martian basalts and cumulates. Moreover, calculating the water content of the magma a phosphate crystallized from is not always possible, and yet is an essential step to estimate how much water was present in a parent magma and its source. Water, however, is primarily dissolved in the interiors of differentiated planets as hydrogen in lattice defects of nominally anhydrous minerals (olivine, pyroxene, feldspar) of the crust and mantle. This hydrogen has tremendous influence, even in trace quantities, on a planet's formation, geodynamics, cooling history and the origin of its volcanism and atmosphere as well as its potential for life. Studies of hydrogen in nominally anhydrous phases of Martian meteorites are rare. Measuring water contents and hydrogen isotopes in well-characterized nominally anhydrous minerals of Martian meteorites is the goal of our study. Our work aims at deciphering what influences the distribution and origin of hydrogen in Martian minerals, such as source, differentiation, degassing and shock.

Peslier, A. H.↗

Volatile Concentrations and H-Isotope Composition of Unequilibrated Eucrites

Eucrites are among the oldest and best studied asteroidal basalts (1). They represent magmatism that occurred on their parent asteroid, likely 4-Vesta, starting at ~ 4563 Ma and continuing for approx. 30 Myr. Two hypotheses are debated for the genesis of eucrites, a magma ocean model (2), and a mantle partial melting model. In general, volatiles (H, C, F, Cl) have been ignored for eucrites and 4-Vesta, but solubility of wt% levels of H2O are possible at Vestan interior PT conditions. Targeted measurements on samples could aid our understanding considerably. Recent studies have found evidence of volatile elements in eucrites, but quantifying the abundance of volatiles remains problematic (6). Volatile elements have a disproportionately large effect on melt properties and phase stability, relative to their low abundance. The source of volatile elements can be elucidated by examining the hydrogen isotope ratio (D/H), as different H reservoirs have drastically different H isotope compositions. Recent studies of apatite in eucrites have shown that the D/H of 4-Vesta matches that of Earth and carbonaceous chondrites, however, the D/H of apatites may not represent the D/H of a primitive 4-Vesta melt due to the possibility of degassing prior to the crystallization of apatite. Therefore, the D/H of early crystallizing phases must be measured to determine if the D/H of 4-Vesta is equal to that of the Earth and carbonaceous chondrites.

Sarafian, Adam R.↗

Observational Constraints on the Identification of Shallow Lunar Magmatism: Insights from Floor-Fractured Craters

Floor-fractured craters are a class of lunar crater hypothesized to form in response to the emplacement of a shallow magmatic intrusion beneath the crater floor. The emplacement of a shallow magmatic body should result in a positive Bouguer anomaly relative to unaltered complex craters, a signal which is observed for the average Bouguer anomaly interior to the crater walls. We observe the Bouguer anomaly of floor-fractured craters on an individual basis using the unfiltered Bouguer gravity solution from GRAIL and also a degree 100-600 band-filtered Bouguer gravity solution. The low-magnitude of anomalies arising from shallow magmatic intrusions makes identification using unfiltered Bouguer gravity solutions inconclusive. The observed anomalies in the degree 100-600 Bouguer gravity solution are spatially heterogeneous, although there is spatial correlation between volcanic surface morphologies and positive Bouguer anomalies. We interpret these observations to mean that the spatial heterogeneity observed in the Bouguer signal is the result of variable degrees of magmatic degassing within the intrusions.

Jozwiak, L. M.↗

Performance Evaluation of the International Space Station Flow Boiling and Condensation Experiment (FBCE) Test Facility

A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.

microgravity↗

In Situ Measurement of Atmospheric Krypton and Xenon on Mars with Mars Science Laboratory

Mars Science Laboratorys Sample Analysis at Mars (SAM) investigation has measured all of the stable isotopes of the heavy noble gases krypton and xenon in the martian atmosphere, in situ, from the Curiosity Rover at Gale Crater, Mars. Previous knowledge of martian atmospheric krypton and xenon isotope ratios has been based upon a combination of the Viking missions krypton and xenon detections and measurements of noble gas isotope ratios in martian meteorites. However, the meteorite measurements reveal an impure mixture of atmospheric, mantle, and spallation contributions. The xenon and krypton isotopic measurements reported here include the complete set of stable isotopes, unmeasured by Viking. The new results generally agree with Mars meteorite measurements but also provide a unique opportunity to identify various non-atmospheric heavy noble gas components in the meteorites. Kr isotopic measurements define a solar-like atmospheric composition, but deviating from the solar wind pattern at 80Kr and 82Kr in a manner consistent with contributions originating from neutron capture in Br. The Xe measurements suggest an intriguing possibility that isotopes lighter than 132Xe have been enriched to varying degrees by spallation and neutron capture products degassed to the atmosphere from the regolith, and a model is constructed to explore this possibility. Such a spallation component, however, is not apparent in atmospheric Xe trapped in the glassy phases of martian meteorites.

Conrad, P. G.↗

Constraining Our Understanding of the Actions and Effects of Martian Volatiles Through the Study of Returned Samples

Volatiles have clearly played a key role in the evolution of Mars' atmosphere, hydrosphere and geosphere, with effects ranging from the geomorphological evidence for outflow channels and valley networks early in Mars' history to formation of alteration products in rocks to the current seasonal changes in the polar caps. It is clear that the absolute and relative abundances of various volatiles have changed through time via volcanic degassing, atmospheric loss, and interactions with the crust.

Source record↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Assessment of Volatile Depletion Mechanisms for the Moon - Pre-Cursors, Giant Impact, Core Formation, Post-Impact Loss

The volatile element depletions in the Moon have been recognized for decades. Multiple explanations have been debated, and arguments have become more quantitative, in large part due to new elemental partitioning and isotopic data. Depletions in pre-cursor materials and due to post-accretion degassing have been evaluated using isotopic data. Partitioning of many volatile elements into metallic cores can now be evaluated for many volatile siderophile elements (VSE). Here is presented an evaluation of the role of core formation for 12 volatile siderophile elements for which partitioning data is now available. Examination of all 12 elements at once allows recognition of general trends, without undue focus on one element. Ga, Ge, Zn, Sn, As, Sb, Cd, Ag, Bi, P, In, Cu are all moderately to highly volatile, and will be discussed in their order of volatility as gauged by their 50 percent condensation temperature.

Righter, K.↗

D/H Isotope Fractionation During H Diffusion Loss from Clinopyroxene Evidenced in Martian Nakhlites

Knowing the distribution and origin of water in terrestrial planets is crucial to understand their formation, evolution and the source of their atmospheres and surface water. Mantle D/H ratios may be used to determine what type of material contributed water to the terrestrial planets [1]. However, other processes, magmatic or surface alteration processes, can also modify D/H ratios, and for Mars, we only have samples from the crust, as meteorites. The D/H ratio of igneous phases of Martian meteorites is generally explained in terms of the mixing contributions of two reservoirs: surficial with high D/H (dD > 700 ‰) related to interaction with the martian atmosphere (dD ~ 5000‰), and mantle-derived with lower D/H (dD < 500 ‰ but the exact value is still debated)[2]. However, our present study evidences that H loss in clinopyroxene during degassing can significantly fractionate H isotopes and increase their D/H ratios. In situ analyses of H isotopes, and of water, major and trace element contents were performed on the pyroxenes of 5 nakhlites. Nakhlites are clinopyroxenites that likely originated from the same lava flow or shallow magma chamber. Water contents decrease (380 to <5 ppm H2O) with increasing dD (-268 to 4860 ‰). Significant influence from spallation, exchange with the martian atmosphere, shock, surface alteration, and hydrothermal processes is ruled out. Together with the evidence of less water at the edge of individual pyroxene grains compared to their interior, we interpret this correlation as the result of preferential diffusive loss of H relative to D from the already crystallized pyroxenes during ascent of the partially-crystallized magma. Similar H isotope fractionations have been observed in another nominally anhydrous mineral, garnet, during experimental dehydration [3]. These results emphasize that caution is warranted when interpreting H isotope analyses of igneous, nominally anhydrous minerals in terms of planetary processes.

Peslier, A. H.↗

Multiple Reservoirs of Volatiles in the Moon Revealed by the Isotopic Composition of Chlorine in Lunar Basalts

The isotopes of chlorine (37Cl and 35Cl) are highly fractionated in lunar samples compared to most other Solar System materials. Recently, the chlorine isotope signatures of lunar rocks have been attributed to large-scale degassing processes that occurred during the existence of a magma ocean. In this study we investigated how well a suite of lunar basalts, most of which have not previously been analyzed, conform to previous models. The Cl isotope compositions (δ37Cl (‰) = [(37Cl/35Clsample/37Cl/35ClSMOC) − 1] × 1000, where SMOC refers to standard mean ocean chloride) recorded range from ∼+7 to +14‰ (Apollo 15), +10 to +19‰ (Apollo 12), +9 to +15‰ (70017), +4 to +8‰ (MIL 05035), and +15 to +22‰ (Kalahari 009). The Cl isotopic data from the present study support the mixing trends previously reported by Boyce et al. (2015) and Barnes et al. (2016), as the Cl isotopic composition of apatites are positively correlated with bulk-rock incompatible trace element abundances in the low-Ti basalts, inclusive of low-Ti and KREEP basalts. This trend has been interpreted as evidence that incompatible trace elements, including Cl, were concentrated in the urKREEP residual liquid of the lunar magma ocean, rather than the mantle cumulates, and that urKREEP Cl had a highly fractionated isotopic composition. The source regions for the basalts were thus created by variable mixing between the mantle (Cl-poor and relatively unfractionated) and urKREEP. The high-Ti basalts show much more variability in measured Cl isotope ratios and scatter around the trend formed by the low-Ti basalts. Most of the data for lunar meteorites also fits the mixing of volatiles in their sources, but Kalahari 009, which is highly depleted in incompatible trace elements, contains apatites with heavily fractionated Cl isotopic compositions. Given that Kalahari 009 is one of the oldest lunar basalts and ought to have been derived from very early-formed mantle cumulates, a heavy Cl isotopic signature is likely not related to its mantle source, but more likely to magmatic or secondary alteration processes, perhaps via impact-driven vapor metasomatism of the lunar crust.

Mccubbin, Francis M.↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗