Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIGESTIVE SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Nuclear Factor {kappa}-Light Chain-Enhancer of Activated B Cells is Activated by Radiotherapy and is Prognostic for Overall Survival in Patients With Rectal Cancer Treated With Preoperative Fluorouracil-Based Chemoradiotheraphy

Purpose: Rectal cancer is often clinically resistant to radiotherapy (RT) and identifying molecular markers to define the biologic basis for this phenomenon would be valuable. The nuclear factor {kappa}-light chain-enhancer of activated B cells (NF-{kappa}B) is a potential anti-apoptotic transcription factor that has been associated with resistance to RT in model systems. The present study was designed to evaluate NF-{kappa}B activation in patients with rectal cancer undergoing chemoradiotherapy to determine whether NF-{kappa}B activity correlates with the outcome in rectal cancer patients. Methods and Materials: A total of 22 patients underwent biopsy at multiple points in a prospective study and the data from another 50 were analyzed retrospectively. The pretreatment tumor tissue was analyzed for multiple NF-{kappa}B subunits by immunohistochemistry. Serial tumor biopsy cores were analyzed for NF-{kappa}B-regulated gene expression using reverse transcriptase polymerase chain reaction and for NF-{kappa}B subunit nuclear localization using immunohistochemistry. Results: Several NF-{kappa}B target genes (Bcl-2, cellular inhibitor of apoptosis protein [cIAP]2, interleukin-8, and tumor necrosis factor receptor-associated-1) were significantly upregulated by a single fraction of RT at 24 h, demonstrating for the first time that NF-{kappa}B is activated by RT in human rectal tumors. The baseline NF-{kappa}B p50 nuclear expression did not correlate with the pathologic response to RT. However, an increasing baseline p50 level was prognostic for overall survival (hazard ratio, 2.15; p = .040). Conclusion: NF-{kappa}B nuclear expression at baseline in rectal cancer was prognostic for overall survival but not predictive of the response to RT. Larger patient numbers are needed to assess the effect of NF-{kappa}B target gene upregulation on the response to RT. Our results suggest that NF-{kappa}B might play an important role in tumor metastasis but not to the resistance to chemoradiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Hepatic Yttrium-90 Radioembolization in Patients with Unresectable Intrahepatic Cholangiocarcinoma: Factors Associated with Prolonged Survival

Introduction: In unresectable intrahepatic cholangiocarcinoma (ICC), systemic chemotherapy often is viewed as the only option, although efficacy is limited. Radioembolization (RE) using yttrium-90 ({sup 90}Y) microspheres is an accepted therapy for patients with hepatocellular-carcinoma or metastatic liver tumors. However, there are limited data on the value of RE in patients with ICC and few data on factors influencing prognosis. The purpose of our retrospective analysis was to establish which factors influenced time-to-progression (TTP) and overall survival (OS). Methods: Patients with unresectable ICC were treated with {sup 90}Y resin-microspheres and assessed at 3-monthly intervals. Radiologic response was evaluated by using Response Criteria in Solid Tumors (RECIST). Baseline characteristics, biochemical/clinical toxicities, and response were examined for impact on TTP and OS. Results: Thirty-four treatments were administered to 33 patients without major complications. By RECIST, 12 patients had a partial response, 17 had stable disease, and 5 had progressive disease after 3 months. The median OS was 22 months posttreatment and 43.7 months postdiagnosis. Median TTP was 9.8 months. Survival and TTP were significantly prolonged in patients with ECOG 0 (vs. ECOG 1 or 2; median OS: 29.4, 10, and 5.1 months; TTP: 17.5, 6.9, and 2.4 months), tumor burden {<=}25% (OS: 26.7 vs. 6 months; TTP: 17.5 vs. 2.3 months), or tumor response (PR or SD vs. PD; OS: 35.5, 17.7 vs. 5.7 months; TTP: 31.9, 9.8 vs. 2.5 months), respectively (P < 0.001). Conclusions: Radioembolization is an effective and safe option for patients with unresectable ICC. Predictors for prolonged survival are performance status, tumor burden, and RECIST response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison Between Electronic Portal Imaging Device and Cone Beam CT in Radiotherapy Verification of Nasopharyngeal Carcinoma

The demand of greater accuracy in intensity-modulated radiotherapy (IMRT) has driven the development of more advanced verification systems. The purpose of this study is to investigate the differences in verification accuracy in terms of the position error detected between cone-beam computed tomography (CBCT) and electronic portal imaging device (EPID) in the IMRT of nasopharyngeal carcinoma (NPC). Two groups of NPC patients (n = 22 and n = 28) verified by CBCT (G1-CB), EPID (G1-EP), and EPID (G2-EP) only, respectively, were recruited. The positional errors between the G1-CB group and the G2-EP group were compared. In addition, the magnitudes of the position errors of EPID taken in the same session of the CBCT, but after necessary corrections (G1-EP), were analyzed. In the CBCT group, 455 CBCT images (G1-CB) and 206 EPID images (G1-EP) were collected, whereas 319 EPID images (G2-EP) for the EPID group, were recorded. The median position errors detected in CBCT were between 0.80 and 0.90 mm in the antero-posterior (A-P), left-right (L-R), and supero-inferior (S-I) directions, whereas those of the EPID were all 0.50 mm. The magnitude of position deviation detected by the CBCT was higher than that of the EPID and their differences were extremely significant (p < 0.001). The frequencies in the G2-EP group with position errors greater than the tolerance (2 mm) were 32, 42, and 27 in the A-P, L-R, and S-I directions, respectively, which accounted for 16.5%, 21.6%, and 13.9% of the total number of EPID. There was difference in verification capability between the CBCT and EPID when applied to IMRT of NPC patients. Because an average of 1 of 6 verifications in EPID was inferior to that of the CBCT, verification by CBCT is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of perfusion CT in differentiating of pancreatic ductal adenocarcinoma from mass-forming chronic pancreatitis and characterization of isoattenuating pancreatic lesions

Purpose: Multidetector computed tomography (MDCT) is routinely used in the diagnosis of pancreatic ductal adenocarcinoma (PDAC), but it may be inadequate in some cases, especially mass-forming chronic pancreatitis (MFCP) and isoattenuating pancreatic lesions. Perfusion CT (pCT) may help resolve this problem. The aim of this study was to evaluate whether pCT could help differentiating PDAC from MFCP and in characterization of isoattenuating pancreatic lesions. Materials and methods: This prospective study included 89 cases of pancreatic lesions detected by MDCT and further analyzed with pCT. Sixty-one cases with final pathological diagnosis PDAC and 12 cases with MFCP were included from the study. Blood volume (BV), blood flow (BF), mean transit time (MTT), and permeability surface area product (PS) maps were obtained. Perfusion values obtained from the lesions and normal parenchyma were compared. Results: Compared with normal parenchyma, BV, BF, PS were lower and MTT was longer in PDAC and MFCP (p < 0.05). Compared with MFCP, BV, BF, PS were lower and MTT was longer in PDAC (p < 0.001). Compared with normal parenchyma, BV, BF, PS were lower and MTT was longer in isoattenuating lesions, (p < 0.001). Cutoff values of 7.60 mL/100 mL, 64.43 mL/100 mL/min, 28.08 mL/100 mL/min for BV, BF, PS, respectively, provided 100% sensitivity and specificity and 7.47 s for MTT provided 98.3% sensitivity, 80% specificity for distinguishing PDAC from MFCP. Conclusion: pCT is a useful technology that can be helpful in overcoming the limitations of routine MDCT in diagnosing PDAC and characterization of isoattenuating lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The LACSEMS: what radiologists need to know

Endoscopic drainage is increasingly used in lieu of percutaneous or surgical drainage of pancreatitis-related fluid collections. The lumen-apposing, covered, self-expanding, metallic stent (LACSEMS) is a newly produced stent for the transmural drainage of such fluid collections. The use of LACSEMS devices requires close coordination between knowledgeable radiologic and gastrointestinal providers. We review pancreatitis-related fluid collections and show examples from our experience with LACSEMS and the appropriate case selection, planning, deployment, and follow-up for this novel device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis

Aim: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP). Subjects and methods: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP. Results: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75–0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56–0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61–0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53–0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51–0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68–0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84–0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75–0.99, P = 0.001). Conclusion: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of the 'Rendezvous' Technique in Living Related Right Liver Donors with Postoperative Biliary Leakage from Bile Duct Anastomosis

This is a report on two cases of large bile leak following right hepatectomy performed for living related liver transplantation, originating from the stump of the ligated right bile duct, and treated with the placement of large percutaneous biliary catheters through a combined percutaneous transhepatic and endoscopic approach (rendezvous technique).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microcatheter Use for Difficult Percutaneous Biliary Procedures

Percutaneous biliary drainage procedures in patients with nondilated ducts are demanding, resulting in lower success rates than in patients with bile duct dilatation. Pertinent clinical settings include patients with iatrogenic bile leaks, diffuse cholangiocarcinomas, and sclerosing cholangitis. We describe a method to facilitate these procedures with the combined use of a 2.7-Fr microcatheter and a 0.018-in. hydrophilic wire.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Therapeutic Decision-Making in Endoscopically Unmanageable Nonvariceal Upper Gastrointestinal Hemorrhage

The purpose of this study was to identify endoscopic and clinical parameters influencing the decision-making in salvage of endoscopically unmanageable, nonvariceal upper gastrointestinal hemorrhage (UGIH) and to report the outcome of selected therapy. We retrospectively retrieved all cases of surgery and arteriography for arrest of endoscopically unmanageable UGIH. Only patients with overt bleeding on endoscopy within the previous 24 h were included. Patients with preceding nonendoscopic hemostatic interventions, portal hypertension, malignancy, and transpapillar bleeding were excluded. Potential clinical and endoscopic predictors of allocation to either surgery or arteriography were tested using statistical models. Outcome and survival were regressed on the choice of rescue and clinical variables. Forty-six arteriographed and 51 operated patients met the inclusion criteria. Univariate analysis revealed a higher number of patients with a coagulation disorder in the catheterization group (41.4%, versus 20.4% in the laparotomy group; p = 0.044). With multivariate analysis, the identification of a bleeding peptic ulcer at endoscopy significantly steered decision-making toward surgical rescue (OR = 5.2; p = 0.021). Taking into account reinterventions, hemostasis was achieved in nearly 90% of cases in both groups. Overall therapy failure (no survivors), rebleeding within 3 days (OR = 3.7; p = 0.042), and corticosteroid use (OR = 5.2; p = 0.017) had a significant negative impact on survival. The odds of dying were not different for embolotherapy or surgery. In conclusion, decision-making was endoscopy-based, with bleeding peptic ulcer significantly directing the choice of rescue toward surgery. Unsuccessful hemostasis and corticosteroid use, but not the choice of rescue, negatively affected outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palliation of Obstructing Malignant Colonic Lesions Using Self-Expanding Metal Stents: A Single-Center Experience

To evaluate the efficacy, risks, and survival after palliative colorectal stenting at a single center, we conducted a retrospective review of consecutive patients who had colorectal self-expanding metal stents (SEMSs) inserted over an 8-year period (September 1998 to September 2006) to relieve an obstructing colorectal tumor. All patients either had proven distant metastases or were unfit for surgical decompression. A single interventional radiologist (R.M.) inserted the stents, which were either Memotherm or WallFlex. Ninety-one patients with a median age of 73 years had a colorectal stent inserted for palliation of an obstructing colorectal malignancy. Technical success was achieved in 81 of 91 (89%) patients, and clinical success in 80 of 81 (99%). At the time of analysis (December 2006), 13 of 91 (14.2%) patients were alive. The patients who died had a median survival of 59 days, IQR 17-181 days. Seven (7/81) patients suffered stent migration, which occurred 10.3 days (IQR, 5-14 days) after the procedure. Three patients (3/81) re-presented with intestinal obstruction secondary to tumor ingrowth and 10 (10.9%) patients suffered bowel perforation. Ten patients (10.9%) had two stents inserted coaxially and overlapping in one procedure. This was performed in cases where the stricture was too long to be easily crossed by a single stent. We conclude that colorectal SEMS is a safe and effective mode of treatment for the palliation of obstructing colorectal cancers, which avoids high-risk surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluoroscopy-Guided Removal of Pull-Type Gastrostomy Tubes

These case reports demonstrate a radiologic interventional technique for removal of pull-type gastrostomy tubes. This approach proved to be a safe and efficient procedure in two patients. The procedure may be applicable in situations where endoscopic attempts fail.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoembolization (TACE) of Unresectable Intrahepatic Cholangiocarcinoma with Slow-Release Doxorubicin-Eluting Beads: Preliminary Results

The purpose of this study was to evaluate the safety and efficacy of TACE with microspheres preloaded with doxorubicin in unresectable intrahepatic cholangiocarcinoma (UCH). Twenty patients with UCH were observed; 9 refused, preferring other palliative care or chemotherapy, and 11 agreed to be treated with one or more cycles of DC beads loaded with doxorubicin (100-150 mg) in a TACE procedure between February 2006 and September 2007. A total of 29 individual TACE procedures were performed. Follow-up imaging was performed on all patients before, immediately after, and 4 weeks after each TACE procedure to evaluate the response and need for further treatment. Each patient received i.v hydration, antibiotics, and medications against nausea and pain before TACE. Survival rate was calculated using Kaplan-Meier survival curve. A response rate of 100% followed RECIST criteria was observed. Eight of eleven patients are alive, with a median survival of 13 months. TACE was well tolerated by all patients. One patient developed hepatic abscess requiring antibiotic therapy. No evidence of marrow toxicity has been reported. Only one of nine patients treated with chemotherapy or palliative care is alive (with a median survival of 7 months in this group of patients). In conclusion, we suggest that doxorubicin-eluting beads TACE is a feasible and effective treatment in patients with UCH. Survival seems to be clearly prolonged in the treated group with respect to the palliative group. We consider that doxorubicin-eluting beads TACE of 100-150 mg may be an appropriate palliative therapy for these patients. Further studies are warranted to confirm these interesting preliminary data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiographic Response to Yttrium-90 Radioembolization in Anterior Versus Posterior Liver Segments

The purpose of our study was to determine if preferential radiographic tumor response occurs in tumors located in posterior versus anterior liver segments following radioembolization with yttrium-90 glass microspheres. One hundred thirty-seven patients with chemorefractory liver metastases of various primaries were treated with yttrium-90 glass microspheres. Of these, a subset analysis was performed on 89 patients who underwent 101 whole-right-lobe infusions to liver segments V, VI, VII, and VIII. Pre- and posttreatment imaging included either triphasic contrast material-enhanced CT or gadolinium-enhanced MRI. Responses to treatment were compared in anterior versus posterior right lobe lesions using both RECIST and WHO criteria. Statistical comparative studies were conducted in 42 patients with both anterior and posterior segment lesions using the paired-sample t-test. Pearson correlation was used to determine the relationship between pretreatment tumor size and posttreatment tumor response. Median administered activity, delivered radiation dose, and treatment volume were 2.3 GBq, 118.2 Gy, and 1,072 cm{sup 3}, respectively. Differences between the pretreatment tumor size of anterior and posterior liver segments were not statistically significant (p = 0.7981). Differences in tumor response between anterior and posterior liver segments were not statistically significant using WHO criteria (p = 0.8557). A statistically significant correlation did not exist between pretreatment tumor size and posttreatment tumor response (r = 0.0554, p = 0.4434). On imaging follow-up using WHO criteria, for anterior and posterior regions of the liver, (1) response rates were 50% (PR = 50%) and 45% (CR = 9%, PR = 36%), and (2) mean changes in tumor size were -41% and -40%. In conclusion, this study did not find evidence of preferential radiographic tumor response in posterior versus anterior liver segments treated with yttrium-90 glass microspheres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of Colorectal Liver Metastases: Small Size Favorably Predicts Technique Effectiveness and Survival

The objective of this study was to analyze long-term results of radiofrequency thermal ablation (RFA) for colorectal metastases (MTS), in order to evaluate predictors for adverse events, technique effectiveness, and survival. One hundred ninety-nine nonresectable MTS (0.5-8 cm; mean, 2.9 cm) in 122 patients underwent a total of 166 RFA sessions, percutaneously or during surgery. The technique was 'simple' or 'combined' with vascular occlusion. The mean follow-up time was 24.2 months. Complications, technique effectiveness, and survival rates were statistically analyzed. Adverse events occurred in 8.1% of lesions (major complication rate: 1.1%), 7.1% with simple and 16.7% with combined technique (p = 0.15). Early complete response was obtained in 151 lesions (81.2%), but 49 lesions (26.3%) recurred locally after a mean of 10.4 months. Sustained complete ablation was achieved in 66.7% of lesions {<=}3 cm versus 33.3% of lesions >3 cm (p < 0.0001). Survival rates at 1, 3, and 5 years were 91%, 54%, and 33%, respectively, from the diagnosis of MTS and 79%, 38%, and 22%, respectively, from RFA. Mean survival time from RFA was 31.5 months, 36.2 in patients with main MTS {<=}3 cm and 23.2 in those with at least one lesion >3 cm (p = 0.006). We conclude that 'simple' RFA is safe and successful for MTS {<=}3 cm, contributing to prolong survival when patients can be completely treated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Management of Biliary Strictures After Pediatric Liver Transplantation

We analyze our experience with the management of biliary strictures (BSs) in 27 pediatric patients who underwent liver transplantation with the diagnosis of BS. Mean recipient age was 38 months (range, 2.5-182 months). In all patients percutaneous transhepatic cholangiography, biliary catheter placement, and bilioplasty were performed. In 20 patients the stenoses were judged resolved by percutaneous balloon dilatation and the catheters removed. Mean number of balloon dilatations performed was 4.1 (range, 3-6). No major complications occurred. All 20 patients are symptom-free with respect to BS at a mean follow-up of 13 months (range, 2-46 months). In 15 of 20 patients (75%) one course of percutaneous stenting and bilioplasty was performed, with no evidence of recurrence of BS at a mean follow-up of 15 months (range, 2-46 months). In 4 of 20 patients (20%) two courses of percutaneous stenting and bilioplasty were performed; the mean time to recurrence was 9.8 months (range, 2.4-24 months). There was no evidence of recurrence of BS at a mean follow-up of 12 months (range, 2-16 months). In 1 of 20 patients (5%) three courses of percutaneous stenting and bilioplasty were performed; there was no evidence of recurrence of BS at a mean follow-up of 10 months. In conclusion, BS is a major problem following pediatric liver transplantation. Radiological percutaneous treatment is safe and effective, avoiding, in most cases, surgical revision of the anastomosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Radiofrequency Ablation in Patients with Hepatic Metastases from Breast Cancer

The purpose of this study was to evaluate technical success, technique effectiveness, and survival following radiofrequency ablation for breast cancer liver metastases and to determine prognostic factors. Forty-three patients with 111 breast cancer liver metastases underwent CT-guided percutaneous radiofrequency (RF) ablation. Technical success and technique effectiveness was evaluated by performing serial CT scans. We assessed the prognostic value of hormone receptor status, overexpression of human epidermal growth factor receptor 2 (HER2), and presence of extrahepatic tumor spread. Survival rates were calculated using the Kaplan-Meier method. Technical success was achieved in 107 metastases (96%). Primary technique effectiveness was 96%. During follow-up local tumor progression was observed in 15 metastases, representing a secondary technique effectiveness of 86.5%. The overall time to progression to the liver was 10.5 months. The estimated overall median survival was 58.6 months. There was no significant difference in terms of survival probability with respect to hormone receptor status, HER2 overexpression, and presence of isolated bone metastases. Survival was significantly lower among patients with extrahepatic disease, with the exception of skeletal metastases. We conclude that CT-guided RF ablation of liver metastases from breast cancer can be performed with a high degree of technical success and technique effectiveness, providing promising survival rates in patients with no visceral extrahepatic disease. Solitary bone metastases did not negatively affect survival probability after RF ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Thermal Ablation Using Ferrofluids: Influence of Administration Mode on Biological Effect in Different Porcine Tissues

The purpose of this study was to compare the effects of magnetic thermal ablation in different porcine tissues using either a singular injection or a continuous infusion of superparamagnetic iron oxide nanoparticles. In the first setting samples of three ferrofluids containing different amounts of iron (1:171, 2:192, and 3:214 mg/ml) were singularly interstitially injected into specimens of porcine liver, kidney, and muscle (n = 5). Then the specimens were exposed to an alternating magnetic field (2.86 kA/m, 190 kHz) generated by a circular coil for 5 min. In the second experimental setup ferrofluid samples were continuously interstitially infused into the tissue specimens during the exposure to the magnetic field. To measure the temperature increase two fiber-optic temperature probes with a fixed distance of 0.5 cm were inserted into the specimens along the puncture tract of the injection needle and the temperature was measured every 15 s. Finally, the specimens were dissected, the diameters of the created thermal lesions were measured, and the volumes were calculated and compared. Compared to continuous infusion, a single injection of ferrofluids resulted in smaller coagulation volumes in all tissues. Significant differences regarding coagulation volume were found in kidney and muscle specimens. The continuous infusion technique led to more elliptically shaped coagulation volumes due to larger diameters along the puncture tract. Our data show the feasibility of magnetic thermal ablation using either a single interstitial injection or continuous infusion for therapy of lesions in muscle, kidney, and liver. Continuous infusion of ferrofluids results in larger zones of necrosis compared to a single injection technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗