Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

ElectroMon Geometry Considerations: Simulations of Electron Transport to a Diamond-Based Detector

Particle-in-Cell simulations were performed to investigate the effects of electrode bias and pitch on the expected number of electrons arriving at a diamond-based detector at a set of relevant incident electron energies for electron cloud monitoring. Results of these simulations indicate that the pitch of the electrodes directly impacts the number of incident electrons based on complete opacity of the electrodes to the electrons; image charge does not play a role at any relevant electron energy. Positive bias on the incident electrodes directly increases the energy of the incident electrons, while negative bias reduces the energy and completely repels incoming electrons of energies lower than the applied bias. These results are intended to be used as input parameters for a solid-state simulation which will determine the collection efficiency of the electron-hole pairs produced within the diamond as a function of position and energy.

43 PARTICLE ACCELERATORS↗

Proof of Concept Simulations of the Multi-Isotope Process Monitor: An Online, Nondestructive, Near-Real-Time Safeguards Monitor for Nuclear Fuel Reprocessing Facilities

The International Atomic Energy Agency (IAEA) will require the development of advanced technologies to effectively safeguard nuclear material at increasingly large-scale nuclear recycling facilities. Ideally, the envisioned technologies would be capable of nondestructive, near-real-time, autonomous process monitoring. This paper describes recent results from model simulations designed to test the Multi-Isotope Process (MIP) monitor, a novel approach to safeguarding reprocessing plants. The MIP monitor combines the detection of intrinsic gamma ray signatures emitted from process solutions with multivariate analysis to detect off-normal conditions in process streams nondestructively and in near-real-time. Three computer models including ORIGEN-ARP, AMUSE, and SYNTH were used in series to predict spent nuclear fuel composition, estimate element partitioning during separation, and simulate spectra from product and raffinate streams using a variety of gamma detectors, respectively. Simulations were generated for fuel with various irradiation histories and under a variety of plant operating conditions. Principal component analysis (PCA) was applied to the simulated gamma spectra to investigate pattern variations as a function of acid concentration, burnup, and cooling time. Hierarchical cluster analysis (HCA) and partial least squares (PLS) were also used in the analysis. The MIP monitor was found to be sensitive to induced variations of several operating parameters including distinguishing ±2.5% variation from normal process acid concentrations. The ability of PLS to predict burnup levels from simulated spectra was also demonstrated to be within 3.5% of measured values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Minimizing Backgrounds for the SuperCDMS SNOLAB Dark-Matter Experiment

Astronomical and cosmological observations indicate that large amounts of some slowly moving, unseen Dark Matter pervades the universe and outweighs normal matter by a factor of five. The Standard Model of Physics has no contender with the properties of this as-yet-undetected particle, so experimentalists build state-of-the-art radiation detectors to attempt to directly measure this Dark Matter. The Super Cryogenic Dark Matter Search (SuperCDMS) at Snolab is one such experiment, currently being constructed. This experiment uses ultra-cold, superconducting, high-purity silicon and germanium detectors to measure low-energy nuclear recoils from the elastic scattering of Dark Matter. I contributed to the calibration of the energy scale of low-energy nuclear recoils in CDMS II silicon detectors by computing an improved livetime correction for calibration data to verify the Monte Carlo rate normalization. Results indicate that the phonon collection efficiency of nuclear recoils relative to electron recoils is 95.2$^{+0.9}_{-0.7\%}$, and the ionization collection efficiency of low-energy nuclear recoils in silicon is lower than Lindhard prediction, consistent with other recent measurements. Backgrounds from the progeny decay of the abundant, naturally-occurring radioactive isotope radon-222 obstruct the sensitivity of essentially every dark-matter search. Radon concentrations in the Snolab cavern would contribute prohibitively large backgrounds if the volume surrounding the detectors were not purged with a low-flow low-radon gas. By measuring the radon diffusion and emanation, we identified acceptable gasket materials for sealing this radon purge, ensuring that the radon-induced backgrounds will be significantly lower than the other experimental backgrounds. A radon emanation system with a gas handling system and low-background radon detector was commissioned and used to measure the radon emanation of the proposed gaskets. A low-cost apparatus was constructed to measure the radon diffusion of gaskets with a commercial radon detector. The sensitivity of future generations of dark-matter detectors are expected to be dominated by long-lived low-energy beta- and alpha-emitting radon daughters such as 210 Pb on detector surfaces. I describe simulations indicating the detector could also be used to reduce background from material impurities plaguing rare-event searches, the commissioning of a prototype demonstration detector, and a gas handling system necessary to operate the detector. I demonstrated that the gas handling system reduces the otherwise dominant backgrounds by a factor of 62. This detector will therefore be able to detect 32 Si and 210 Pb 100 times better than currently available screeners.

Bowles, Michael A.↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling External Radiation Transport Code Results to the GADRAS Detector Response Function

Simulating gamma spectra is useful for analyzing special nuclear materials. Gamma spectra are influenced not only by the source and the detector, but also by the external, and potentially complex, scattering environment. The scattering environment can make accurate representations of gamma spectra difficult to obtain. By coupling the Monte Carlo Nuclear Particle (MCNP) code with the Gamma Detector Response and Analysis Software (GADRAS) detector response function, gamma spectrum simulations can be computed with a high degree of fidelity even in the presence of a complex scattering environment. Traditionally, GADRAS represents the external scattering environment with empirically derived scattering parameters. By modeling the external scattering environment in MCNP and using the results as input for the GADRAS detector response function, gamma spectra can be obtained with a high degree of fidelity. This method was verified with experimental data obtained in an environment with a significant amount of scattering material. The experiment used both gamma-emitting sources and moderated and bare neutron-emitting sources. The sources were modeled using GADRAS and MCNP in the presence of the external scattering environment, producing accurate representations of the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuSD: A Geant4 based simulation framework for segmented anti-neutrino detectors

NuSD: Neutrino Segmented Detector is a Geant4-based user application that simulates inverse beta decay event in a variety of segmented scintillation detectors developed by different international collaborations. This simulation framework uses a combination of cross-programs and libraries including Geant4, ROOT and CLHEP developed and used by high energy physics community. It will enable the neutrino physics community to simulate and study neutrino interactions within different detector concepts using a single program. In addition to neutrino simulations in segmented detectors, this program can also be used for various research projects that use of scintillation detectors for different physics purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal ''image-based'' weighting for energy-resolved CT

This paper investigates a method of reconstructing images from energy-resolved CT data with negligible beam-hardening artifacts and improved contrast-to-nosie ratio (CNR) compared to conventional energy-weighting methods. Conceptually, the investigated method first reconstructs separate images from each energy bin. The final image is a linear combination of the energy-bin images, with the weights chosen to maximize the CNR in the final image. The optimal weight of a particular energy-bin image is derived to be proportional to the contrast-to-noise-variance ratio in that image. The investigated weighting method is referred to as ''image-based'' weighting, although, as will be described, the weights can be calculated and the energy-bin data combined prior to reconstruction. The performance of optimal image-based energy weighting with respect to CNR and beam-hardening artifacts was investigated through simulations and compared to that of energy integrating, photon counting, and previously studied optimal ''projection-based'' energy weighting. Two acquisitions were simulated: dedicated breast CT and a conventional thorax scan. The energy-resolving detector was simulated with five energy bins. Four methods of estimating the optimal weights were investigated, including task-specific and task-independent methods and methods that require a single reconstruction versus multiple reconstructions. Results demonstrated that optimal image-based weighting improved the CNR compared to energy-integrating weighting by factors of 1.15-1.6 depending on the task. Compared to photon-counting weighting, the CNR improvement ranged from 1.0 to 1.3. The CNR improvement factors were comparable to those of projection-based optimal energy weighting. The beam-hardening cupping artifact increased from 5.2% for energy-integrating weighting to 12.8% for optimal projection-based weighting, while optimal image-based weighting reduced the cupping to 0.6%. Overall, optimal image-based energy weighting provides images with negligible beam-hardening artifacts and improved CNR compared to energy-integrating and photon-counting methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The GlueX Start Counter Detector

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

Final Report of the Simulation Optimization Task Force

This is the final report of the ATLAS Simulation Optimization Task Force, establishedin June of 2007. This note justifies the selected Geant4 version, physics list, and range cuts to be used by the default ATLAS simulation for initial data taking and beyond. The current status of several projects, including detector description, simulation validation, studies of additional Geant4 parameters, and cavern background, are reported.

79 ASTRONOMY AND ASTROPHYSICS↗

MCNPX Simulation Study of STRAW Neutron Detectors

A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating (only 1 micron thick) of {sup 10}B as a neutron converter inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2 mils thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90%/10% of Ar/CO{sub 2}). The tubes operate in proportional counter mode and attract mobile charged particles ({alpha}'s) created in the nuclear interaction {sup 10}B(n, {sup 4}He){sup 7}Li. However, a single tube has about 1/7th the sensitivity of a {sup 3}He tube. Modeling is required to determine if enough such tubes could be placed in a neutron detection assembly of the current size to give comparable sensitivity to {sup 3}He. Detectors lined with {sup 10}B lie between {sup 3}He and {sup 10}BF{sub 3} proportional counters and fission chambers in terms of neutron detection efficiency and gamma ray insensitivity. The mean free path of thermal neutrons in {sup 10}B is about 18 {micro}m. It takes about 60 {micro}m of {sup 10}B layer to completely stop thermal neutrons, but the energetic {alpha}-particles generated in the reaction have a range of only 3.3 {micro}m in {sup 10}B environment - hence the thin layer of boron coating on the copper tube. The prototype design is shown in Figure 1. It consists of two panels of three staggered rows of 500-mm-long, 4-mm-diameter straws, with 20 in each row, embedded in 30-mm-thick high density polyethylene (HDPE). The project demonstrates a new application of thin neutron and gamma converter technique (1 micron thin {sup 10}B coated copper tube). It exploits fast timing from multiple straw detectors to count multiplicity of both gamma and neutrons from fissioning materials. The objective is to find a near-term replacement of {sup 3}He gas in neutron detection and measurement (with a very large neutron detection area). All the solid-state detectors developed thus far are small and inefficient. The thin size of the straws provides imaging capability with high enough resolution for radiation emitting sources. The prototype will provide the first aerial neutron detection system with directional sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Electric Field in Semi Insulating Au/CdTe/Au Detector under Flux

We report our simulations on the profile of the electric field in semi insulating CdTe and CdZnTe with Au contacts under radiation flux. The type of the space charge and electric field distribution in the Au/CdTe/Au structure is at high fluxes result of a combined influence of charge formed due to band bending at the electrodes and from photo generated carriers, which are trapped at deep levels. Simultaneous solution of drift-diffusion and Poisson equations is used for the calculation. We show, that the space charge originating from trapped photo-carriers starts to dominate at fluxes 10{sup 15}-10{sup 16}cm{sup -2}s{sup -1}, when the influence of contacts starts to be negligible.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Examination of simulated behavior of ND-LAr and TMS detectors using CAFAna for DUNE analysis framework

Simulations are run using the new DUNE CAFAna framework to generate pseudo-data modeling the interactions of neutrinos in the DUNE near detector at truth-level and detector-level. Truth-level analysis of neutrino kinematics reveals strong agreement with expected behavior, validating the kinematic portion of the simulation. Examination of the detector-level reconstructions of coordinates of interaction vertex appear consistent with an interaction density independent of detector position. Track lengths of particles resultant from neutrino interactions are aligned with varied particle identities, but are misaligned with prediction of uniform position density.

Fein, Jarrett [Fermilab]↗

Development of two-band infrared radiometer for irradiance calibration of target simulators

A detector-based spectral radiometer has been developed for the calibration of target simulator. Unlike the conventional spectral irradiance calibration method based on radiance and irradiance, the new radiometer is calibrated using image-space temperature based method. The image-space temperature based method improves the reproducibility in the calibration of radiometer and reduces the uncertainties existing in the conventional calibration methods. The calibrated radiometer is then used to establish the irradiance transfer standard for the target simulator. With the designed radiometer in this paper, a highly accurate irradiance calibration for target simulators of wavelength from 2.05 to 2.55 μm and from 3.7 to 4.8 μm can be performed with an expanded uncertainty (k = 2) of calibration of 2.18%. Last but not least, the infrared radiation of the target simulator was measured by the infrared radiometer, the effectiveness and capability of which are verified through measurement of temperature and irradiance and a comparison with the thermal imaging camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Magnetic Fields on LArTPCs, ArCS

ArCS is implementing magnetic fields to LarTPC detectors in order to develope their ability to do charge separation. This poster shows two algorithms that take simulated LarTPC detectors with magnetic fields, and compares their performance as a function of magnetic field and momentum in order to establish what field is needed for charge separation to work well.

Lopez, Alex [U. Chicago (main)]↗

Artificial Intelligence for Event Reconstruction and Higgs Physics at CMS and Future Colliders

This dissertation charts a trajectory in which advances in artificial intelligence (AI) play a central role in pushing the high-energy physics frontier, complementing progress driven by higher collision energies and larger colliders. The discovery potential of the LHC and future colliders relies on accurate reconstruction of increasingly complex particle collision events. In the CMS experiment, this task is performed by the particle-flow (PF) algorithm. This dissertation presents the first implementation of a machine-learning-based particle-flow (MLPF) reconstruction in the CMS detector based on transformer architectures. In simulated top quark--antiquark pair (ttbar) events under LHC Run~3 (2023--2024) conditions, MLPF improves jet energy resolution by 10--20\% compared to standard PF for jets with transverse momentum between 30--100\GeV. Runtime performance is evaluated using simulated multijet events, with a median inference time of 20\unit{ms} per event on an NVIDIA L4 GPU, compa red to approximately 110\unit{ms} for standard PF. The MLPF algorithm is also validated on Run~3 collision data, representing the first data-validated ML-based reconstruction pipeline at any LHC experiment. We then extend MLPF toward future electron--positron colliders and introduce the first full-simulation cross-detector transfer learning workflow for PF reconstruction. The model is pre-trained on simulated events from the Compact Linear Collider detector (CLICdet) and fine-tuned on the CLIC-like detector (CLD) proposed for the Future Circular Collider (FCC). This approach achieves up to a 40\% improvement in jet energy resolution over rule-based reconstruction while reducing the required training dataset size by an order of magnitude, demonstrating the potential of AI to accelerate detector development and optimization. This dissertation also demonstrates how modern AI techniques enhance the sensitivity of LHC physics analyses. A CMS search for highly Lorentz-boosted Higgs bosons decaying to \textrm{W} boson pairs is presented, focusing on the single-lepton final state. A dedicated fine-tuning strategy for \ParT yields an approximately 70\% increase in expected sensitivity relative to the baseline model. The analysis uses proton--proton collision data at a center-of-mass energy of \ensuremath{\sqrt{s}=13\TeV} collected by CMS between 2016 and 2018, corresponding to an integrated luminosity of 138\ensuremath{\ \mathrm{fb}^{-1}}. The expected significance of the search is $1.86\sigma$, with an observed signal strength of $-0.19^{+0.48}_{-0.46}$. Finally, explainable AI techniques are applied to the MLPF and \ParticleNet algorithms using layerwise relevance propagation, showing that both models base their predictions on physically meaningful features consistent with our physics intuition. Together, these results demonstrate how advanced AI methods can enhance reconstruction, analysis sensitivity, and interpretability, shaping the next era of experimental parti cle physics.

Mokhtar, Farouk [UC, San Diego]↗

J/{psi} Production with NRQCD: HERA, Tevatron, RHIC and LHC

We report on our recent calculation of the inclusive direct photo- and hadroproduction of the J/{psi} meson at next-to-leading order within the factorization formalism of nonrelativistic QCD. We fit the color-octet (CO) long-distance matrix elements <O{sup J}/{psi}(1S{sub 0}{sup [8]})>, <O{sup J}/{psi}(3S{sub 1}{sup [8]})> and <O{sup J}/{psi}(3P{sub 0}{sup [8]})> to the transverse momentum (p{sub T}) distributions measured by CDF at Fermilab Tevatron and by H1 at DESY HERA and show that they also successfully describe the p{sub T} distributions from PHENIX at BNL RHIC and CMS at the CERN LHC as well as the photon-proton c.m. energy and (with worse agreement) the inelasticity distributions from H1. In all experiments, the CO processes are shown to be indispensable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗