Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

2D imaging of absolute methyl concentrations in nanosecond pulsed plasma by photo-fragmentation laser-induced fluorescence

The methyl radical plays a central role in plasma-assisted hydrocarbon chemistry but is challenging to detect due to its high reactivity and strongly pre-dissociative electronically excited states. In this work, we report the development of a photo-fragmentation laser-induced fluorescence (PF-LIF) diagnostic for quantitative 2D imaging of methyl profiles in a plasma. This technique provides temporally and spatially resolved measurements of local methyl distributions, including in near-surface regions that are important for plasma-surface interactions such as plasma-assisted catalysis. The technique relies on photo-dissociation of methyl by the fifth harmonic of a Nd:YAG laser at 212.8 nm to produce CH fragments. These photofragments are then detected with LIF imaging by exciting a transition in the B-X(0, 0) band of CH with a second laser at 390 nm. Fluorescence from the overlapping A-X(0, 0), A-X(1, 1), and B-X(0, 1) bands of CH is detected near 430 nm with the A-state populated by collisional B-A electronic energy transfer. This non-resonant detection scheme enables interrogation close to a surface. The PF-LIF diagnostic is calibrated by producing a known amount of methyl through photo-dissociation of acetone vapor in a calibration gas mixture. We demonstrate PF-LIF imaging of methyl production in methane-containing nanosecond pulsed plasmas impinging on dielectric surfaces. Absolute calibration of the diagnostic is demonstrated in a diffuse, plane-to-plane discharge. Measured profiles show a relatively uniform distribution of up to 30 ppm of methyl. Relative methyl measurements in a filamentary plane-to-plane discharge and a plasma jet reveal highly localized intense production of methyl. The utility of the PF-LIF technique is further demonstrated by combining methyl measurements with formaldehyde LIF imaging to capture spatiotemporal correlations between methyl and formaldehyde, which is an important intermediate species in plasma-assisted oxidative coupling of methane.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Experimental Proof of the Principal Role of Reduced High-Mode Hydrodynamic Mix in Recent Ignition Success on NIF

This Letter details the role of reduced hydrodynamic mix in achieving the first fusion plasma to satisfy the Lawson criterion for ignition. Using novel 3D measurements of the temperature and density of the burning deuterium-tritium plasma across a series of experiments, we demonstrate that hydrodynamic mixing from small-scale capsule defects was a key degradation mechanism inhibiting ignition. A series of five layered deuterium-tritium experiments using 1.9 MJ of laser energy demonstrates a 2 × reduction of the thermonuclear yield when a lower quality capsule, typical of preignition experiments, is used. Radiation hydrodynamic calculations consistent with the observed mix profile show that the mixed fuel’s reduced compression and increased radiative loss explain the yield reduction. Furthermore, a hydroscaling argument suggests that a ∼ 3 MJ laser would be needed to reach ignition with such a capsule, well beyond the current capabilities of high energy laser systems. As such, this Letter gives critical insight into the physics of mix in self-heated fusion plasmas and establishes a foundation to evaluate capsule quality needs of future inertial fusion designs that aim at ignition and high gain.

High-energy-density plasmas↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Knock-on deuteron imaging for diagnosing the morphology of an ICF implosion at OMEGA

Knock-on deuteron imaging is a new diagnostic technique that is being implemented at the OMEGA laser facility to diagnose the morphology of an inertial confinement fusion (ICF) implosion. It utilizes the fact that some of the neutrons from deuterium–tritium (DT)-fusion reactions generated in the central hot-spot of an ICF implosion elastically scatter deuterons as they traverse the surrounding shell layer. The energy of these “knock-on” deuterons depends on the scattering angle, where the most energetic deuterons are forward-scattered and probe the shape of the central hot-spot, while lower-energy deuterons are made by side-scattering or slowing down in the fuel and carry information about the distribution of the dense DT-fuel layer surrounding the hot-spot. The first proof-of-concept tests have been conducted successfully. In these tests, three penumbral imagers with different views on an implosion recorded deuterons scattered from the dense shell of DT-gas-filled deuterated plastic shell implosions with prescribed offsets. Data from these experiments are presented here, along with novel analysis techniques that iteratively reconstruct the deuteron source from the data. Reconstructed hot-spot and shell radii agree with 1D hydro simulations and indicate a P1 asymmetry in the direction of the offset. A comparison of coaxial deuteron and x-ray images suggests the presence of a mix between the hot-spot and shell on the order of 15 μm. This new diagnostic capability will allow us to study asymmetries in unprecedented detail at OMEGA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Neural networks: Application to medical imaging

The research mission is the development of computer assisted diagnostic (CAD) methods for improved diagnosis of medical images including digital x-ray sensors and tomographic imaging modalities. The CAD algorithms include advanced methods for adaptive nonlinear filters for image noise suppression, hybrid wavelet methods for feature segmentation and enhancement, and high convergence neural networks for feature detection and VLSI implementation of neural networks for real time analysis. Other missions include (1) implementation of CAD methods on hospital based picture archiving computer systems (PACS) and information networks for central and remote diagnosis and (2) collaboration with defense and medical industry, NASA, and federal laboratories in the area of dual use technology conversion from defense or aerospace to medicine.

Clarke, Laurence P.↗

Statistical uncertainties in temperature diagnostics for hot coronal plasma using the ASCA SIS

Statistical uncertainties in determining the temperatures of hot (0.5-10 keV) coronal plasmas are investigated. The statistical presicion of various spectral temperature diagnostics is established by analyzing synthetic ASCA solid-state imaging spectrometer (SIS) CCD spectra. The diagnostics considered are the ratio of hydrogen-like to helium-like line complexes of Z greater than or = 14 elements, line-free portions of the continuum, and the entire spectrum. While fits to the entire spectrum yield the highest statistical precision, it is argued that fits to the line-free continuum are less susceptible to atomic data uncertainties but lead to a modest increase in statistical uncertainty over full spectral fits. Temperatures deduced from line ratios can have similar accuracy, but only over a narrow range of temperatures. Convenient estimates of statistical accuracies for the various temperature diagnostics are provided which may be used in planning ASCA SIS observations.

Swartz, Douglas A.↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of ultrafast laser pulse repetition rate on filament acoustic and emission signatures

Femtosecond filaments formed at standoff distances can be used for interrogating various types of matter, making them of potential interest for remote sensing. However, the physical aspects of the filaments generated at standoff distances are influenced by various environmental and laser properties, including the repetition rate of the laser. In this study, we evaluate the role of the predecessor pulse on the properties of filaments by varying the repetition rate of the laser in the range of 10–1000 Hz and using acoustic and emission signatures to diagnose filament properties. Our results show that filaments are brighter at high repetition rates while they are elongated at low repetition rates. The repetition rate has minimal influence on the downstream edge of the filament generation, while the upstream edge becomes elongated. The shadowgram images showed that the turbulence generated by the predecessor pulse may influence the next pulse when the laser is operating at high repetition rates.

47 OTHER INSTRUMENTATION↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging Spectrometers Using Concave Holographic Gratings

Imaging spectroscopy combines the spatial attributes of imaging with the compositionally diagnostic attributes of spectroscopy. For spacebased remote sensing applications, mass, size, power, data rate, and application constrain the scanning approach. For the first three approaches, substantial savings in mass and size of the spectrometer can be achieved in some cases with a concave holographic grating and careful placement of an order-sorting filter. A hologram etched on the single concave surface contains the equivalent of the collimating, dispersing, and camera optics of a conventional grating spectrometer and provides substantial wavelength dependent corrections for spherical aberrations and a flat focal field. These gratings can be blazed to improve efficiency when used over a small wavelength range or left unblazed for broadband uniform efficiency when used over a wavelength range of up to 2 orders. More than 1 order can be imaged along the dispersion axis by placing an appropriately designed step order-sorting filter in front of the one- or two-dimensional detector. This filter can be shaped for additional aberration corrections. The VIRIS imaging spectrometer based on the broadband design provides simultaneous imaging of the entrance slit from lambda = 0.9 to 2.6 microns (1.5 orders) onto a 128 x 128 HgCdTe detector (at 77 K). The VIRIS spectrometer was used for lunar mapping with the UH 24.in telescope at Mauna Kea Observatory. The design is adaptable for small, low mass, space based imaging spectrometers.

Gradie, J.↗

An image classification deep-learning algorithm for shrapnel detection from ultrasound images

Ultrasound imaging is essential for non-invasively diagnosing injuries where advanced diagnostics may not be possible. However, image interpretation remains a challenge as proper expertise may not be available. In response, artificial intelligence algorithms are being investigated to automate image analysis and diagnosis. Here, we highlight an image classification convolutional neural network for detecting shrapnel in ultrasound images. As an initial application, different shrapnel types and sizes were embedded first in a tissue mimicking phantom and then in swine thigh tissue. The algorithm architecture was optimized stepwise by minimizing validation loss and maximizing F1 score. The final algorithm design trained on tissue phantom image sets had an F1 score of 0.95 and an area under the ROC curve of 0.95. It maintained higher than a 90% accuracy for each of 8 shrapnel types. When trained only on swine image sets, the optimized algorithm format had even higher metrics: F1 and area under the ROC curve of 0.99. Overall, the algorithm developed resulted in strong classification accuracy for both the tissue phantom and animal tissue. This framework can be applied to other trauma relevant imaging applications such as internal bleeding to further simplify trauma medicine when resources and image interpretation are scarce.

59 BASIC BIOLOGICAL SCIENCES↗

NASA Tech Briefs, November 2004

Topics include: Multifunction Imaging and Spectroscopic Instrument; Position-Finding Instrument Built Around a Magnetometer; Improved Measurement of Dispersion in an Optical Fiber; Probe for Sampling of Interstitial Fluid From Bone; Neuropsychological Testing of Astronauts; Method of Calibration for a Large Cathetometer System; Four-Channel PC/104 MIL-STD-1553 Circuit Board; Improved Method of Locating Defects in Wiring Insulation; Strobe Traffic Lights Warn of Approaching Emergency Vehicles; Improved Timing Scheme for Spaceborne Precipitation Radar; Concept for Multiple-Access Free-Space Laser Communications; Variable Shadow Screens for Imaging Optical Devices; Verifying Diagnostic Software; Initial Processing of Infrared Spectral Data; Activity-Centric Approach to Distributed Programming; Controlling Distributed Planning; New Material for Surface-Enhanced Raman Spectroscopy; Treated Carbon Nanofibers for Storing Energy in Aqueous KOH; Advanced Infant Car Seat Would Increase Highway Safety; Development of Biomorphic Flyers; Second-Generation Six-Limbed Experimental Robot; Miniature Linear Actuator for Small Spacecraft; Process for Making Single-Domain Magnetite Crystals; A New Process for Fabricating Random Silicon Nanotips; Resin-Transfer-Molding of a Tool Face; Improved Phase-Mask Fabrication of Fiber Bragg Gratings; Tool for Insertion of a Fiber-Optic Terminus in a Connector; Nanofluidic Size-Exclusion Chromatograph; Lightweight, Low-CTE Tubes Made From Biaxially Oriented LCPs; Using Redundancy To Reduce Errors in Magnetometer Readings; Compact Instrument for Measuring Profile of a Light Beam; Multilayer Dielectric Transmissive Optical Phase Modulator; Second-Generation Multi-Angle Imaging Spectroradiometer; Real-Time Adaptive Color Segmentation by Neural Networks; Research and Development in Optical Communications; Tests of Multibeam Scintillation Mitigation on Laser Uplinks; and Spaceborne Infrared Atmospheric Sounder.

Source record↗

Computational modeling and neutron imaging to understand interface shape and solute segregation during the vertical gradient freeze growth of BaBrCl:Eu

In this work we apply continuum models to analyze phase change, heat transfer, fluid flow, solute transport, and segregation in order to understand prior neutron imaging observations of the vertical gradient freeze growth of Eu-doped BaBrCl. The models provide a rigorous framework in which to understand the mechanisms that are responsible for the complicated evolution of interface shape and dopant distribution in the growth experiment. We explain how a transition in the solid/liquid interface shape from concave to convex is driven by changes in radial heat transfer caused by furnace design. We also provide a mechanistic explanation of how dynamic growth conditions and changes of the flow structure in the melt result in complicated segregation patterns in this system. A growth pause caused by controller lock-up is shown to result in a band of solute depletion in accordance with classical theory. However, changing flow patterns during growth result in a non-monotonic axial distribution of solute that cannot be explained by simple application of classical segregation models. We assert that the approach presented here, namely the use of rigorous models in conjunction advanced diagnostics, such as neutron imaging, provides an exciting path forward for process optimization and control, accelerating the incremental advances that have, in the past, typically relied on empiricism, experience, and intuition.

36 MATERIALS SCIENCE↗