Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ti/Zr isomorphism in wadeite: The crystal structure of the titanium-dominant K{sub 2}(Ti{sub 0.55}Zr{sub 0.45})Si{sub 3}O{sub 9} member of the series

The crystal structure of the titanium-rich mineral wadeite K{sub 2}(Ti{sub 0.55}Zr{sub 0.45})Si{sub 3}O{sub 9} from rischorrites of the Khibiny Alkaline Massif (Kola Peninsula, Russia) is studied by X-ray diffraction (XCalibur-S diffractometer, R = 0.0459): a = 6.8611(6) Å and c = 10.0611(9) Å; space group P6{sub 3}/m, Z = 6, D{sub x} = 3.03 g/cm{sup 3}. It is shown that the unit-cell parameters and volume of the mineral of mixed (Ti/Zr) composition are naturally intermediate between those of the terminal members of the isomorphous wadeite-based K{sub 2}ZrSi{sub 3}O{sub 9}–K{sub 2}(Ti{sub 0.55}Zr{sub 0.45})Si{sub 3}O{sub 9}–K{sub 2}TiSi{sub 3}O{sub 9} series. The expected correlation is due to the ionic radii of Zr{sup 4+} and Ti{sup 4+} which determine the lengths of Zr/Ti–O bonds in octahedra. The data of field observations and microscopic studies show that the Ti-dominant wadeite is formed on the basis of primary zirconium mineral in the course of a late imposed process under unique geochemical conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Algorithm and program for precise determination of unit-cell parameters of single crystal taking into account the sample eccentricity

A technique has been developed to refine the unit-cell parameters of single crystals with minimization of the influence of instrumental errors on the result. The corresponding computational procedure HuberUB is added to the software package of Huber-5042 diffractometer with a point detector and closedcycle helium cryostat Displex DE-202. The parameters of unit cell, its orientation, the goniometer zero angles, the sample eccentricity, the distances in the goniometer, and the radiation wavelength were refined by the nonlinear least-squares method, which allows imposition of constraints on the unit-cell parameters, depending on the crystal symmetry. The technique is approved on a LuB{sub 12} single crystal. The unit-cell parameters are determined in a temperature range of 20–295 K, with an absolute error not larger than 0.0004 Å (the relative error is of ~5 × 10{sup –5}). The estimates of the unit-cell parameters obtained by the proposed method are evidenced to be unbiased. Some specific features of the behavior of parameters in the ranges of 120–140 and 20–50 K are revealed, which correlate with the anomalies of the physical properties of the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural Analysis of Sr{sub 3}NbFe{sub 3}Si{sub 2}O{sub 14} Single Crystal from the Langasite Family and Finding of Negative Thermal Expansion in the Range of 83–110 K

Iron-containing Sr{sub 3}NbFe{sub 3}Si{sub 2}O{sub 14} single crystals from the langasite family, which are interesting for researchers due to their magnetic ordering at T{sub N} = 26 K, have been grown by the floating zone melting method. Accurate X-ray diffraction analysis is performed at 293 and 90.5 K using the data collected on a CCD diffractometer. To compensate for systematic errors, two data sets are collected at each temperature. The structure is refined based on averaged data set: sp. gr. P321, Z = 1, sin θ/λ ≤ 1.35 Å{sup –1}; a = 8.2609(4) Å, c = 5.1313(3) Å at 293 K and a = 8.2344(6) Å, c = 5.1243(6) Å at 90.5 K; the agreement factors are R/wR = 1.18/1.03% and Δρ{sub min}/Δρ{sub max} =–0.57/0.25 e/Å3 for 3583 independent reflections at 293 K and R/wR = 1.18/1.13% and Δρ{sub min}/Δρ{sub max} =–0.54/0.23 e/Å3 for 3638 reflections at 90.5 K. Negative thermal expansion in the direction of the cell c axis is revealed in the range of 83–110 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate Refinement of the Crystal Structure of Ba{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} from Langasite Family and Analysis of Structural Transformations Due to Isomorphous Cation Substitutions

An accurate structure analysis of a Ba{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} single crystal from langasite family was performed using four X-ray diffraction data sets collected on a diffractometer equipped with a CCD area detector (sp. gr. P321, Z = 1, sinθ/λ ≤ 1.35 Å{sup –1}; at 295 K a = 8.516(1) Å, c = 5.1910(6) Å, R/wR = 0.58/0.56%, Δρ{sub min}/Δρ{sub max} =–0.73/0.42 e/Å{sup 3}, 4414 independent reflections; at 106 K a = 8.5109(9) Å, c = 5.1861(9) Å, R/wR = 0.75/0.86%, Δρ{sub min}/Δρ{sub max} =–0.81/1.06 e/Å{sup 3}, 4382 reflections). The distinguishing feature of the Ba{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14} structure is a strong disorder of the Ga atom at the 3f site. Structural transformations in the series of Сa{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14}–Sr{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14}–Ba{sub 3}TaGa{sub 3}Si{sub 2}O{sub 14}–Ba{sub 3}TaFe{sub 3}Si{sub 2}O{sub 14} crystals were analyzed.

36 MATERIALS SCIENCE↗

X-Ray Structure Investigation of Sr{sub 3}NbGa{sub 3}Si{sub 2}O{sub 14} Langasite Family Crystal

An accurate structure analysis of Sr{sub 3}NbGa{sub 3}Si{sub 2}O{sub 14} single crystals, belonging to the langasite family, has been performed. Two datasets are obtained on an Xcalibur S diffractometer equipped with a CCD detector. The structure is been refined using an averaged dataset: sp. gr. P 321, Z = 1, 295 K, sin θ/λ ≤ 1.35 Å{sup –1}, a = 8.2797(3) Å, c = 5.0774(5) Å; the agreement factors between the model and experiment are found to be R/wR = 0.76/0.64% and Δρ{sub min}/Δρ{sub max} =–0.21/0.17 e/Å{sup 3} for 3820 independent ref lections. The Sr{sub 3}NbGa{sub 3}Si{sub 2}O{sub 14} and Sr{sub 3}NbFe{sub 3}Si{sub 2}O{sub 14} structures are compared, and the role of magnetic ions in the predicted P321 → P3 phase transition is analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Double-Crystal Rocking Curve Simulation Using 2D Spectral Angular Diagrams of X-Ray Radiation

A new approach to numerical simulation of double-crystal rocking curves is proposed. This approach is based on the use of experimental spectral angular diagrams of X-ray intensity distribution. Special calculation algorithms, which take into account the instrumental function of X-ray diffractometer and possible effects of dispersion and Bragg reflection asymmetry, have been developed and applied. A specific feature of the proposed approach is the possibility of visualizing the 2D spectral angular diagram of X-ray beam after its interaction with each element of the scheme. The approach makes it possible to perform calculations for a wide range of radiation sources (from an X-ray tube with any anode to a synchrotron radiation source) and X-ray optical elements (slits and monochromators). A comparison of simulation results and experimental data for a Si(110) crystal sample has confirmed adequacy of the proposed approach and its applicability for simulating diffraction patterns recorded in real experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microfluidic Cell for Studying the Precrystallization Stage Structure of Protein Solutions by Small-Angle X-Ray Scattering

A microfluidic cell has been developed for studying the structure of protein solutions using small-angle X-ray scattering. The use of prefabricated elements, which provide a small sample volume, allows one to adjust the microfluidic cell parameters to specific problems. Tests of lysozyme solutions were performed on a laboratory diffractometer AMUR-K (Institute of Crystallography, Russian Academy of Sciences), BM29 beamline (ESRF, Grenoble), and “DICSY” beamline of the Kurchatov synchrotron radiation source (National Research Centre “Kurchatov Institute”). Experiments showed that, when a 60-μm-thick quartz glass of special purity grade is applied as an X-ray-transparent window, the intrinsic level of cell background scattering in the range of measured angles is lower than that for quartz capillaries, due to which the measurement accuracy can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectometry of X-ray Whispering Gallery Waves Propagating along Liquid Meniscuses

X-ray reflectometry of whispering galleries (WGs), which propagate along meniscuses of deionized water or silica hydrosols (Ludox{sup ®} SM) enriched by Cs{sup +} ions, was analyzed for the first time. The measurements were performed using the diffractometer with a moving tube-detector system. The X-ray beam rotation angle reached a maximum value of 4° on a silica hydrosol sample at CuK{sub α} radiation, while for H{sub 2}O it is only 1°. The intensities of WG modes propagating near the surface of a concave meniscus were found from the rigorous solution of the respective Helmholtz equation and applying the Monte Carlo technique for the random surface. For analysis of intensities of the X-ray scattering we used a hybrid model of the liquid surface with the upper transition layer having sinusoidal ripples in which the concentration of levitating Cs{sup +} ions has a maximum near the surface, derived from the experiment, while the concentration maximum for SiO{sub 2} particles with sizes of ~6–15 nm is positioned at the depth of ~15 nm from the hydrosol’s surface. Our numerical results for reflectances are in a good agreement with the experimental data.

36 MATERIALS SCIENCE↗

Short-Range Order in α-FeAl Soft Magnetic Alloy

The atomic structure of iron–aluminum alloy samples containing about 7 at % of aluminum (α region of the phase diagram) was investigated by X-ray diffraction. The samples were annealed in the paramagnetic (T > {sup T}{sub C}) and ferromagnetic (T < T{sub C}) states. In the first case, the structural state was fixed by quenching from the annealing temperature in water, and, in the second case, by slow cooling. Diffraction patterns of single-crystal samples were taken on an X-ray four-circle diffractometer. It is shown that local ordering, regardless of the prehistory of a sample, is a combination of B2-phase clusters (the CsCl type structure), which were previously found in iron–silicon alloys with Si content up to 10%, and small regions with D0{sub 3} short-range order. The former consist of two B2-cells having a common face, while the latter consist predominantly of one unit cell of the D0{sub 3}-phase. Within the accuracy of the experiment, no significant difference in the structural states in the paramagnetic and ferromagnetic phases was observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mössbauer Studies and the Microwave Properties of Al{sup 3+}- and In{sup 3+}-Substituted Barium Hexaferrites

The correlation of the chemical composition, the structure, and the microwave characteristic of solid solutions of the BaFe{sub 12–x}D{sub x}O{sub 19} (0.1 ≤ x ≤ 1.2) barium hexaferrite substituted with diamagnetic Al{sup 3+} and In{sup 3+} ions has been studied. The precise data on the crystal structure have been obtained by powder neutron diffraction using a high-resolution Fourier diffractometer (Dubna, JINR). The data on the distribution of the diamagnetic substituting ions in the hexaferrite structure have been obtained by Mössbauer spectroscopy. The microwave properties (the transmittance and the reflectance) have been studied in the frequency range 20–65 GHz and in external magnetic fields to 8 kOe. It is found that the transmission spectra are characterized by a peak that corresponds to the resonant frequency of the electromagnetic energy absorption, which is due to the ferromagnetic resonance phenomenon. The correlation of the chemical composition, the features of the ion distribution in the structure, and the electromagnetic properties has been revealed. It is shown that external magnetic fields shift the absorption peak of electromagnetic radiation to higher frequencies due to an increase in the magnetocrystal anisotropy. The results enable the conclusion that the features of the intrasublattice interactions and the electromagnetic properties should be explained using the phenomenological Goodenough–Kanamori model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Annealing in a Ferromagnetic State on the Structure of an Fe–18 at % Ga Alloy

The atomic structure of the iron–gallium alloy containing 18 at % Ga has been studied by X-ray diffraction. The samples were annealed in the paramagnetic (T > T{sub C}) and ferromagnetic (T < T{sub C}) state. In the first case, the structural state was fixed by quenching from the annealing temperature into water; in the second case, the structural state was obtained by slow cooling. The structural studies of the single-crystal samples were conducted on a four-circle X-ray diffractometer at room temperature. From the X-ray diffraction data, it follows that the alloy, independently on the heat treatment, contains B2 clusters, i.e., locally ordered regions with the CsCl-type structure observed in alloys of iron with silicon (to 10 at % Si) and aluminum (7 at % Al) before. In addition to the B2‑clusters, regions with the D0{sub 3} short-range order are observed in the quenched sample; the sizes of these regions significantly increases after annealing in the ferromagnetic state, i.e., a long-range order forms. The relation of the fine structural changes in the alloy due to various heat treatments with its magnetoelastic and magnetostriction properties is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Finding a New B1-Type Phase in Single Crystals of Fe–Al and Fe–Ga Soft Magnetic Alloys

The atomic structure of Fe–Al (7 and 9 at % Al) and Fe–Ga (18 at % Ga) alloys is studied by X‑ray diffraction using a laboratory four-circle diffractometer. After refining annealing, single-crystal alloy samples were annealed in the ferromagnetic state (T < T{sub C}). One sample of the Fe–18 at % Ga alloy, after short holding in the paramagnetic state (T > T{sub C}), was quenched in room temperature water. Earlier, the authors reported on the peculiarities of the ordering of alloying atoms in B2 and D0{sub 3} phase structures in quenched and annealed samples of these alloys. Here, we present and discuss the results of our observations in these alloys of a new phase with a face-centered cubic (fcc) lattice (B1-type structure with NaCl prototype and unit cell parameter ~5.2 nm). The fcc phase appears in the Fe–Al alloy as the aluminum concentration increases from 7 to 9 at %; it is observed in the Fe–18 at % Ga alloy, and its volume fraction increases after annealing in the ferromagnetic state in comparison with a quenched alloy sample. In these alloys (9 at % Al) and (18 at % Ga), different ways of embedding fcc crystals in the bcc phase of single crystals are realized; i.e., the axes of the fcc lattice are directed in four different ways relative to the axes of the bcc lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of silver metallization and electron irradiation on the mechanical deformation of polyimide films

The impact of silver metallization and electron irradiation on the physical and mechanical properties of polyimide films has been studied. The metal that impregnated the structure of the polyimide substrate was 1–5 μm. The surface coatings contained 80–97% of the relative silver mirror in the visible and infrared regions. Irradiation was performed at the ELU-6 linear accelerator with an average beam electron energy of 2 MeV, an integral current of up to 1000 μA, a pulse repetition rate of 200 Hz, and a pulse duration of 5 μs. The absorbed dose in the samples was 10, 20, 30, and 40 MGy. The samples were deformed at room temperature under uniaxial tension on an Instron 5982 universal testing system. The structural changes in the composite materials that result from the impact of the physical factors were studied using an X-ray diffractometer DRON-2M in air at 293 K using CuK{sub α} radiation (λ{sub αCu} = 1.5418 Å). A substantial growth of mechanical characteristics resulting from the film metallization, as compared to the pure film, was observed. The growth of the ultimate strength by Δσ = 105 MPa and the plasticity by Δε = 75% is connected with the characteristics of the change of structure of the metallized films and the chemical etching conditions. The electron irradiation of the metallized polyimide film worsens its elastic and strength characteristics due to the formation of new phases in the form of silver oxide in the coating. The concentration of these phases increased with increasing dose, which was also the result of the violation of the ordered material structure, namely, the rupture of polyimide macromolecule bonds and the formation of new phases of silver in the coating. A mathematical model was obtained that predicts the elastic properties of silver metallized polyimide films. This model agrees with the experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying irradiation defects in zirconium alloys: a comparison between transmission electron microscopy and whole-pattern diffraction line-profile analysis - 2016-0089

Irradiation-induced dislocations significantly affect the mechanical properties of zirconium alloys, altering slip and influencing creep and growth. Thus, the quantitative characterization of irradiation defects as a function of fluence, cold work, and/or thermal treatments is important for models that attempt to predict their impact on properties. Whole-pattern diffraction line-profile analysis (DLPA) is a well-established modern tool for microstructure characterization based on first-principle physical models for dislocation density measurements in plastically deformed materials. However, applying these DLPA methods directly to irradiated materials yields higher than expected dislocation density values compared with historical transmission electron microscopy (TEM) measurements and past line-broadening analysis studies calibrated to TEM observations. In an effort to understand these differences, a new microstructural model was developed for DLPA to specifically address dislocation structures consisting of elliptical - and -component loops. To compare the refined DLPA method with TEM measurements, high-resolution neutron diffraction patterns on nonirradiated and irradiated Zr-2.5Nb samples were collected with the Neutron Powder Diffractometer instrument at the Los Alamos Neutron Science Center and were evaluated. High-resolution TEM measurements were performed at the Reactor Materials Testing Laboratory, Queen's University, for comparison with the DLPA results. The capabilities and inherent uncertainties of both the refined DLPA and TEM methods are compared and discussed in detail. We show that the differences between the density values provided by DLPA and TEM are inherent to the methods and can be reconciled with the interpretation of the data. (authors)

36 MATERIALS SCIENCE↗

POWGEN: a third-generation high resolution high-throughput powder diffraction instrument at the Spallation Neutron Source

Powgen represents a departure from previous designs for a time-of-flight powder diffractometer at a spallation neutron source and may be considered a third-generation design. The instrument is optimized for both parametric studies of materials under a wide range of conditions (T, P, H, flowing gases, etc) and ab-initio crystal structure determinations of complex solid-state materials with asymmetric unit-cells of the order {approx}1500 {angstrom}{sup 3}. The geometric design of the instrument allows for all detected scattered neutrons to be focused onto a single diffraction profile yielding high count rate while preserving good resolution {Delta}d/d = 0.0015 at a d = 1 {angstrom}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laboratory Guide for Residual Stress Sample Alignment and Experiment Planning-October 2011 Version

The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in a sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the scan arm creates. Once a model, fiducial, and measurement files are created, a special program, called SScanSS combines the information and by simulation of the sample on the diffractometer can help plan the experiment before using neutron time. Finally, the sample is mounted on the relevant stress measurement instrument and the fiducial points are measured again. In the HFIR beam room, a laser tracker is used in conjunction with a program called CAM2 to measure the fiducial points in the NRSF2 instrument's sample positioner coordinate system. SScanSS is then used again to perform a coordinate system transformation of the measurement file locations to the sample positioner coordinate system. A procedure file is then written with the coordinates in the sample positioner coordinate system for the desired measurement locations. This file is often called a script or command file and can be further modified using excel. It is very important to note that this process is not a linear one, but rather, it often is iterative. Many of the steps in this guide are interdependent on one another. It is very important to discuss the process as it pertains to the specific sample being measured. What works with one sample may not necessarily work for another. This guide attempts to provide a typical work flow that has been successful in most cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of Modified Direct Denitration Development (Milestone Letter Report). MDD Status Letter Report (AFCI CETE Milestone)

Current flow sheets for processing used nuclear fuels do not produce separated streams of all of the actinides. These aqueous processing streams must be converted into solid forms suitable for recycle (fuel/target fabrication), storage, or disposal, necessitating co-conversion. A process developed at ORNL in the 1980s to make UO 3 suitable as fuel feedstock was studied for preparation of mixed actinide oxides with similarly favorable ceramic properties. The process, Modified Direct Denitration (MDD), uses ammonium nitrate to alter the thermal decomposition behavior of metal nitrates and improve the ceramic properties of the resulting solid oxide. Since plutonium (IV) and neptunium(IV) form compounds similar to uranium with the ammonium ion [(NH 4 ) 2 Pu(NO 3 ) 6 , (NH 4 ) 2 Np(NO 3 ) 6 ], MDD-conversion of these metals was considered to be applicable. Co-conversion has advantages for making mixed oxides over individual element conversions that are followed by dry mixing of the oxide powders. Issues associated with preparing a mixture from individual oxides include use of additional equipment, dusting associated with feeding and milling, time requirements for milling, blending to obtain a uniform mixture, and inhomogenity at higher plutonium concentrations. These issues can be partially or wholly avoided by using MDD coconversion in which the mixing of the individual metals occurs in liquid solution; thus, adjusting relative metal concentrations is simpler and the resulting mixed oxide is more uniform than that produced by blending the individual oxides. Utilizing MDD also eliminates the need for mechanical treatment of the powder to obtain the desired ceramic properties, such as surface area and particle size distribution, since these characteristics are acceptable as-produced. The original MDD development work established that uranium oxide with good ceramic properties could be made. Following the discovery, a more fundamental understanding of the chemistry of the uranium-ammonium double nitrate salt was developed. Later pilot-scale studies produced kilogram quantities of UO 3 using engineering-scale (1 kg/hour), continuously-operated equipment, while establishing the reliability of the process and equipment. The current work was performed in support of the Advanced Fuel Cycle Initiative (AFCI), utilizing glove-box-contained equipment (100 g/hour) to produce UO 3 , PuO 2 , and mixed oxides of uranium, plutonium, neptunium, and americium from a nitrate solution of those actinides. Then the MDD glove-box system was utilized in the Coupled-End-To-End (CETE) project to convert the U-Pu-Np and uranium product solutions into oxide powders. As part of the CETE project, a powder characterization laboratory was established in gloveboxes with instruments required for the determination of: (1) surface area by the BET methodology; (2) tap density by using a Quantachrome AutoTap; (3) flow properties by using a Freeman technology powder rheometer; (4) material composition and crystalline structure by using a powder X-ray diffractometer; (5) particle size distribution by using a laser light-scattering analyzer; and (6) imaging of the powders with a stereomicroscope. These instruments can be used to characterize the products and to determine the effects of MDD operating parameters on product powder morphology. Ultimately, the powder characteristics necessary to produce high-density, sintered MOX pellets can be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗