Search NASA⌕ Search

SEARCH · Search NASA

Results for “Discriminant Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Relative effectiveness of kinetic analysis vs single point readings for classifying environmental samples based on community-level physiological profiles (CLPP)

The relative effectiveness of average-well-color-development-normalized single-point absorbance readings (AWCD) vs the kinetic parameters mu(m), lambda, A, and integral (AREA) of the modified Gompertz equation fit to the color development curve resulting from reduction of a redox sensitive dye from microbial respiration of 95 separate sole carbon sources in microplate wells was compared for a dilution series of rhizosphere samples from hydroponically grown wheat and potato ranging in inoculum densities of 1 x 10(4)-4 x 10(6) cells ml-1. Patterns generated with each parameter were analyzed using principal component analysis (PCA) and discriminant function analysis (DFA) to test relative resolving power. Samples of equivalent cell density (undiluted samples) were correctly classified by rhizosphere type for all parameters based on DFA analysis of the first five PC scores. Analysis of undiluted and 1:4 diluted samples resulted in misclassification of at least two of the wheat samples for all parameters except the AWCD normalized (0.50 abs. units) data, and analysis of undiluted, 1:4, and 1:16 diluted samples resulted in misclassification for all parameter types. Ordination of samples along the first principal component (PC) was correlated to inoculum density in analyses performed on all of the kinetic parameters, but no such influence was seen for AWCD-derived results. The carbon sources responsible for classification differed among the variable types with the exception of AREA and A, which were strongly correlated. These results indicate that the use of kinetic parameters for pattern analysis in CLPP may provide some additional information, but only if the influence of inoculum density is carefully considered. c2001 Elsevier Science Ltd. All rights reserved.

NASA Center KSC↗

Improved neutron-gamma discrimination for a {sup 6}Li-glass neutron detector using digital signal analysis methods

A {sup 6}Li-glass scintillator (GS20) based neutron Anger camera was developed for time-of-flight single-crystal diffraction instruments at Spallation Neutron Source. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio (defined as NGD ratio) on the order of 10{sup 4}. The NGD ratios of Anger cameras need to be improved for broader applications including neutron reflectometers. For this purpose, six digital signal analysis methods of individual waveforms acquired from photomultiplier tubes were proposed using (i) charge integration, (ii) pulse-amplitude histograms, (iii) power spectrum analysis combined with the maximum pulse-amplitude, (iv) two event parameters (a{sub 1}, b{sub 0}) obtained from a Wiener filter, (v) an effective amplitude (m) obtained from an adaptive least-mean-square filter, and (vi) a cross-correlation coefficient between individual and reference waveforms. The NGD ratios are about 70 times those from the traditional PHA method. Our results indicate the NGD capabilities of neutron Anger cameras based on GS20 scintillators can be significantly improved with digital signal analysis methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural phylogeny by profile extraction and multiple superimposition using electrostatic congruence as a discriminator

Phylogenetic analysis of proteins using multiple sequence alignment (MSA) assumes an underlying evolutionary relationship in these proteins which occasionally remains undetected due to considerable sequence divergence. Structural alignment programs have been developed to unravel such fuzzy relationships. However, none of these structure based methods have used electrostatic properties to discriminate between spatially equivalent residues. We present a methodology for MSA of a set of related proteins with known structures using electrostatic properties as an additional discriminator (STEEP). STEEP first extracts a profile, then generates a multiple structural superimposition providing a consolidated spatial framework for comparing residues and finally emits the MSA. Residues that are aligned differently by including or excluding electrostatic properties can be targeted by directed evolution experiments to transform the enzymatic properties of one protein into another. We have compared STEEP results to those obtained from a MSA program (ClustalW) and a structural alignment method (MUSTANG) for chymotrypsin serine proteases. Subsequently, we used PhyML to generate phylogenetic trees for the serine and metallo-β-lactamase superfamilies from the STEEP generated MSA, and corroborated the accepted relationships in these superfamilies. We have observed that STEEP acts as a functional classifier when electrostatic congruence is used as a discriminator, and thus identifies potential targets for directed evolution experiments. In summary, STEEP is unique among phylogenetic methods for its ability to use electrostatic congruence to specify mutations that might be the source of the functional divergence in a protein family. Based on our results, we also hypothesize that the active site and its close vicinity contains enough information to infer the correct phylogeny for related proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Elemental Discrimination of Low-Energy Ions using Risetime Analysis of Silicon-Strip Detector Signals

To make measurements with the intense (but often contaminated) radioactive beams available today, one often needs to identify the reaction products to determine the events of interest. The low energies required for many astrophysics measurements make impossible the use of traditional energy loss techniques, and additional constraints are required. We demonstrate a simple technique to measure the risetimes of silicon strip-detector signals and show partial discrimination can be obtained even at energies below 1 MeV/u.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High dimensional binary classification under label shift: phase transition and regularization

Label Shift has been widely believed to be harmful to the generalization performance of machine learning models. Researchers have proposed many approaches to mitigate the impact of the label shift, e.g., balancing the training data. However, these methods often consider the underparametrized regime, where the sample size is much larger than the data dimension. The research under the overparametrized regime is very limited. Here, to bridge this gap, we propose a new asymptotic analysis of the Fisher Linear Discriminant classifier for binary classification with label shift. Specifically, we prove that there exists a phase transition phenomenon: Under certain overparametrized regime, the classifier trained using imbalanced data outperforms the counterpart with reduced balanced data. Moreover, we investigate the impact of regularization to the label shift: The aforementioned phase transition vanishes as the regularization becomes strong.

binary classification↗

Analysis of Spacecraft Materials Discrimination Using Color Indices for Remote Sensing for Space Situational Awareness

The increasing number of space missions have resulted in an augmented density of artificial objects positioned in orbital domains near Earth. Knowing the material composition of the resident space object can be of value in object identification and risk assessment using remote sensing techniques. To perform this task, it is increasingly imperative to optically characterize spacecraft materials to identify unique material-specific spectroscopic markers. In this work, a variety of materials frequently utilized by the aerospace industry in spacecraft design and construction were analyzed using reflectance spectroscopy. The collected data provide a spectral characterization baseline for modern-day and historical spacecraft materials. The color index was computed for standard astronomical and suggested theoretical filter passbands and compared to each other in their capability to discriminate materials belonging to different classes. The color index was calculated from reflectance spectra of common spacecraft materials in their pristine, as-received conditions that fell under different family groupings. Different color-index combinations were studied using color-color diagrams. Visual and quantitative analysis of the color-color diagrams were used to evaluate the possibility of discriminating materials from one another by means of optical measurements. Results of the analysis show that polyimide and photovoltaic materials are most easy to discriminate from all other materials via color indices using different filter passbands evaluated in this study.

spectral reflectance↗

Discrimination of bacillus anthracis and closely related microorganisms by analysis of 16S and 23S rRNA with oligonucleotide microarray.

Analysis of 16S rRNA sequences is a commonly used method for the identification and discrimination of microorganisms. However, the high similarity of 16S and 23S rRNA sequences of Bacillus cereus group organisms (up to 99-100%) and repeatedly failed attempts to develop molecular typing systems that would use DNA sequences to discriminate between species within this group have resulted in several suggestions to consider B. cereus and B. thuringiensis, or these two species together with B. anthracis, as one species. Recently, we divided the B. cereus group into seven subgroups, Anthracis, Cereus A and B, Thuringiensis A and B, and Mycoides A and B, based on 16S rRNA, 23S rRNA and gyrB gene sequences and identified subgroup-specific makers in each of these three genes. Here we for the first time demonstrated discrimination of these seven subgroups, including subgroup Anthracis, with a 3D gel element microarray of oligonucleotide probes targeting 16S and 23S rRNA markers. This is the first microarray enabled identification of B. anthracis and discrimination of these seven subgroups in pure cell cultures and in environmental samples using rRNA sequences. The microarray bearing perfect match/mismatch (p/mm) probe pairs was specific enough to discriminate single nucleotide polymorphisms (SNPs) and was able to identify targeted organisms in 5 min. We also demonstrated the ability of the microarray to determine subgroup affiliations for B. cereus group isolates without rRNA sequencing. Correlation of these seven subgroups with groupings based on multilocus sequence typing (MLST), fluorescent amplified fragment length polymorphism analysis (AFLP) and multilocus enzyme electrophoresis (MME) analysis of a wide spectrum of different genes, and the demonstration of subgroup-specific differences in toxin profiles, psychrotolerance, and the ability to harbor some plasmids, suggest that these seven subgroups are not based solely on neutral genomic polymorphisms, but instead reflect differences in both the genotypes and phenotypes of the B. cereus group organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Background Characterization and Discrimination in the Final Analysis of the CDMS II Phase of the Cryogenic Dark Matter Search

The Cryogenic Dark Matter Search (CDMS) is designed to detectWeakly-Interacting Massive Particles (WIMPs) in the Milky Way halo. The phase known as CDMS II was performed in the Soudan Underground Laboratory. The final set of CDMS II data, collected in 2007-8 and referred to as Runs 125-8, represents the largest exposure to date for the experiment. We seek collisions between WIMPs and atomic nuclei in disk-shaped germanium and silicon detectors. A key design feature is to keep the rate of collisions from known particles producing WIMP-like signals very small. The largest category of such background is interactions with electrons in the detectors that occur very close to one of the faces of the detector. The next largest category is collisions between energetic neutrons that bypass the experimental shielding and nuclei in the detectors. Analytical efforts to discriminate these backgrounds and to estimate the rate at which such discrimination fails have been refined and improved throughout each phase of CDMS. Next-generation detectors for future phases of CDMS require testing at cryogenic test facilities. One such facility was developed at the University of Minnesota in 2007 and has been used continuously since then to test detectors for the next phase of the experiment, known as SuperCDMS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Selecting indicators of soil, microbial, and plant conditions to understand ecological changes in Georgia pine forests

Characterizing how resource use and management activities affect ecological conditions is necessary to document and understand anthropogenic changes in ecological systems. Resource managers on military installations have the delicate task of balancing the training needs of soldiers effectively with the need to maintain a high quality of ecological conditions. This study considers ways that ecological indicators can provide information on impacts that training has on environmental characteristics that occur at different scales and in different sectors of the environment. The characteristics examined include soil chemistry, soil microbes, and vegetation. A discriminant function analysis was conducted to determine whether ecological indicators could differentiate among different levels of military use. A combination of 10 indicators explained 90% of the variation among plots from five different military use levels. Results indicated that an appropriate suite of ecological indicators for military resource managers includes soil, microbial, and vegetation characteristics. Since many of these indicators are related, managers at this location potentially have freedom to choose indicators that are relatively easy to measure, without sacrificing information.

54 ENVIRONMENTAL SCIENCES↗

Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples

The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical analysis of Thematic Mapper Simulator data for the geobotanical discrimination of rock types in southwest Oregon

An evaluation of Thematic Mapper Simulator (TMS) data for the geobotanical discrimination of rock types based on vegetative cover characteristics is addressed in this research. A methodology for accomplishing this evaluation utilizing univariate and multivariate techniques is presented. TMS data acquired with a Daedalus DEI-1260 multispectral scanner were integrated with vegetation and geologic information for subsequent statistical analyses, which included a chi-square test, an analysis of variance, stepwise discriminant analysis, and Duncan's multiple range test. Results indicate that ultramafic rock types are spectrally separable from nonultramafics based on vegetative cover through the use of statistical analyses.

Morrissey, L. A.↗

Measurement of Nuclear Recoils in the CDMS II Dark Matter Search

The Cryogenic Dark Matter Search (CDMS) experiment is designed to directly detect elastic scatters of weakly-interacting massive dark matter particles (WIMPs), on target nuclei in semiconductor crystals composed of Si and Ge. These scatters would occur very rarely, in an overwhelming background composed primarily of electron recoils from photons and electrons, as well as a smaller but non-negligible background of WIMP-like nuclear recoils from neutrons. The CDMS II generation of detectors simultaneously measure ionization and athermal phonon signals from each scatter, allowing discrimination against virtually all electron recoils in the detector bulk. Pulse-shape timing analysis allows discrimination against nearly all remaining electron recoils taking place near detector surfaces. Along with carefully limited neutron backgrounds, this experimental program allowed for \background- free" operation of CDMS II at Soudan, with less than one background event expected in each WIMP-search analysis. As a result, exclusionary upper-limits on WIMP-nucleon interaction cross section were placed over a wide range of candidate WIMP masses, ruling out large new regions of parameter space.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning–Augmented Laser-Induced Breakdown Spectroscopy for Spectral Discrimination of Iron Oxalates

Enhanced characterization and phase identification of post-PUREX Pu Oxalates (PuOXA) are pivotal for nonproliferation and pre-detonation nuclear forensics. Despite significant advances in the characterization of PuO 2 samples, little is known about the impact of both the chemical structure and oxidation states of PuOXA (i.e., Pu(III) and Pu(IV)) have on optical emission signatures. Here, we demonstrate the analytical capabilities of laser-induced breakdown spectroscopy (LIBS) applied to Fe(II) and Fe(III) oxalate samples as surrogates for PuOXA, highlighting the discriminating features in the LIBS emission spectra arising from differences in the oxidation states within mixed FeOXA samples. We report the enhancement of spectral feature selection using Principal Component Analysis (PCA), which enables the analytical superiority of machine learning algorithms such as Linear Discriminant Analysis (LDA), Quadratic Discriminant Analysis (QDA), Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), and Random Forest Regression (RFR) over conventional univariate techniques for phase discrimination and chemometric analysis. Cluster analysis revealed how both matrix effects and laser ablation influence cluster separability by introducing spectral artifacts that misdirect the maximization of variance. PCA-selected emission lines were used in the regression models, demonstrating that both univariate and multivariate linear regression models (i.e., PLSR and SVR) can achieve acceptable performance, with machine learning models outperforming conventional calibration regressions. Furthermore, the application of non-linearly activated PCA-selected emission lines illustrates how simplifying the data while retaining captured variance enables the use of less complex and more computationally efficient models. Furthermore, this is particularly evident in the underperformance of RFR, which suffers from increased computational costs and overfitting owing to its high complexity.

Oxalates↗

ToF-SIMS evaluation of PEG-related mass peaks and applications in PEG detection in cosmetic products

Polyethylene glycols (PEGs) are used in industrial, medical, health care, and personal care applications. The cycling and disposal of synthetic polymers like PEGs pose significant environmental concerns. Detecting and monitoring PEGs in the real world calls for immediate attention. This study unveils the efficacy of time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a reliable approach for precise analysis and identification of reference PEGs and PEGs used in cosmetic products. By comparing SIMS spectra, we show remarkable sensitivity in pinpointing distinctive ion peaks inherent to various PEG compounds. Moreover, the employment of principal component analysis effectively discriminates compositions among different samples. Notably, the application of SIMS two-dimensional image analysis visually portrays the spatial distribution of various PEGs as reference materials. The same is observed in authentic cosmetic products. The application of ToF-SIMS underscores its potential in distinguishing PEGs within intricate environmental context. ToF-SIMS provides an effective solution to studying emerging environmental challenges, offering straightforward sample preparation and superior detection of synthetic organics in mass spectral analysis. These features show that SIMS can serve as a promising alternative for evaluation and assessment of PEGs in terms of the source, emission, and transport of anthropogenic organics.

36 MATERIALS SCIENCE↗