Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Increasing Access to Grid-Tied Distributed Photovoltaics for Low-Income Populations: Considerations for Developing Countries

Governments around the world are under immense pressure to promote inclusive economic growth, reduce budget deficits, and promote sustainable development goals. Such goals may potentially be addressed through public policy approaches to encourage the use of distributed photovoltaic (DPV) systems in developing countries, particularly among low-income electricity customers. At the same time, low-income customers face numerous barriers to DPV deployment including a lack of access to capital and financing, a lack of awareness about the technology, lack of homeownership, and distorted price signals via lower retail tariffs. As a result of these factors, among others, they are often the least likely customers in developed and developing countries alike to deploy solar. However, under the right set of conditions, low-income grid tied DPV programs can offer beneficial outcomes for governments, customers, utilities, and the environment. This brief informs decision makers in developing countries as they explore ways to promote equitable access to solar energy in their communities.

14 SOLAR ENERGY↗

A Framework to Design Consumer-Centric Operational Strategies for Resilience Enhancement

Extreme temperature-related events like heat waves or cold snaps can significantly stress the power distribution grid as electricity demand spikes leading to brownouts or blackouts if not managed properly. In addition, such extreme events can exacerbate inequity, with vulnerable populations (for example, houses with poor insulation, located in non-critical zones, and lack of local resources) at greater risk. There is a growing deployment of distribution systems automation technologies such as advanced metering infrastructure, sensors, and automated control systems to enhance the visibility of the entire distribution grid while meeting resilience objectives. Here, this paper proposes a framework for investigating how automation can improve the distribution system's resilience and ensure customers' health and safety during such extremes. The proposed framework's efficacy will be demonstrated for the Electricity Reliability Council of Texas (ERCOT) during winter storm Uri with varying levels of distribution automation technologies such as feeder isolation using smart switches, remote outage signals using advanced meters, and comfort-aware outage using advanced analytics and communication. Simulation results show that an outage strategy involving advanced grid technology and communication can reduce the occupant exposure to severe cold by 93% and, simultaneously, reduce expected energy not served by 73.2% when compared against feeder isolation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential PV-Energy Storage Testing Collaboration with SunPower: Cooperative Research and Development Final Report, CRADA Number CRD-14-569

Residential scale energy storage devices have shown great promise to add value and improve the ability to integrate distributed and variable generation into the distribution grid. Battery energy storage systems combined with PV and advanced inverters can provide many services. These include extended backup power in case of grid failure, reductions in feeder and system level peak load, system level net load ramp reduction, grid management services both locally (e.g., voltage management) and bulk system (e.g., reserves) level, and improved grid reliability through grid voltage and frequency support. Even though the cost of the energy storage systems are decreasing, one of the main challenges related to the widespread deployment of energy storage, as found by the U.S. Department of Energy (DOE), is utility acceptance of storage technologies. Various interconnection challenges exist when connecting distributed PV-energy storage into the electrical distribution grid in terms of safety, reliability and stability of the electric power systems. Some of the urgent challenges, as seen by the manufacturers and installers are: safety of the battery cells and the packs, performance of the power conversion systems, effect of bidirectional power flow on existing utility equipment and qualification of solutions such as volt-ampere reactive (VAR) support and frequency regulation. Under this project, National Renewable Energy Laboratory (NREL) researchers will work with SunPower to address these challenges by research, testing and analysis at Energy System Integration Facility (ESIF) and energy storage testing laboratory at NREL. NREL's unique power hardware-in-the-loop (PHIL) capability will be utilized to evaluate system-level issues such as reverse power flow and VAR support (if available) for these PV-energy storage systems. Through the analysis of test results, the proposed project will demonstrate use of ESIF capabilities in a way that advances both the DOE and SunPower's goals of moving clean, renewable energy technologies onto the electrical grid.

14 SOLAR ENERGY↗

Distributed Smart Grid Asset Control Strategies for Providing Ancillary Services

With large-scale plans to integrate renewable generation driven mainly by state-level renewable portfolio requirements, more resources will be needed to compensate for the uncertainty and variability associated with intermittent generation resources. Distributed assets can be used to mitigate the concerns associated with renewable energy resources and to keep costs down. Under such conditions, performing primary frequency control using only supply-side resources becomes not only prohibitively expensive but also technically difficult. It is therefore important to explore how a sufficient proportion of the loads could assume a routine role in primary frequency control to maintain the stability of the system at an acceptable cost. The main objective of this project is to develop a novel hierarchical distributed framework for frequency based load control. The framework involves two decision layers. The top decision layer determines the optimal gain for aggregated loads for each load bus. The gains are computed using decentralized robust control methods, and will be broadcast to the corresponding participating loads every control period. The second layer consists of a large number of heterogeneous devices, which switch probabilistically during contingencies so that aggregated power change matches the desired amount according to the most recently received gains. The simulation results show great potential to enable systematic design of demand-side primary frequency control with stability guarantees on the overall power system. The proposed design systematically accounts for the interactions between the total load response and bulk power system frequency dynamics. It also guarantees frequency stability under a wide range of time varying operating conditions. The local device-level load response rules fully respect the device constraints (such as temperature setpoint, compressor time delays of HVACs, or arrival and departure of the deferrable loads), which are crucial for implementing real load control programs. The promise of autonomous, Grid Friendly™ response by smart appliances in the form of under-frequency load shedding was demonstrated in the GridWise Olympic Peninsula Demonstration in 2006. Each controller monitored the power grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances responded reliably to each shallow under-frequency event, which was an average of one event per day and shed their loads for the durations of these events. Another objective of this project was to perform extensive simulation studies to investigate the impact of a population of Grid Friendly™ Appliances (GFAs) on the bulk power system frequency stability. The GFAs considered in this report are represented as demonstration units with water heaters individually modeled.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On benchmarking of simulations of particle transport in ITER

We present results of benchmarking of core particle transport simulations by a collection of codes widely used in transport modelling of tokamak plasmas. Our analysis includes formulation of transport equations, difference between electron and ion solvers, comparison of modules of the pellet and edge gas fuelling on the ITER baseline scenario. During the first phase of benchmarking we address the particle transport effects in the stationary phase. Firstly, simulations are performed with identical sources, sinks, transport coefficients, and boundary conditions prescribed in the flattop H-mode phase. The transformation of ion particle transport equations is introduced so to directly compare their results to electron transport solvers. Moreover, the pellet fuelling models are benchmarked in various conditions to evaluate the dependency of the pellet deposition on the pellet volume, injection side, pedestal and separatrix parameters. Thirdly, edge gas fuelling is benchmarked to assess sensitivities of source profile predictions to uncertainties in plasma conditions and detailed model assumptions. At the second phase, we address particle transport effects in the time-evolving plasma including the current ramp-up to the ramp-down phase. The ion and the electron solvers are benchmarked together. Differences between the simulation results of the solvers are investigated in terms of equilibrium, grid resolution, radial coordinate, radial grid distribution, and plasma volume evolution term. We found that the selection of the radial coordinate can yield prominent differences between the solvers mainly due to differences in the edge grid distribution. The simulations reveal that electron and ion solvers predict noticeably different density peaking for the same diffusion and pinch velocity while with the peaked profile of helium, expected in fusion reactors. The fuelling benchmarking demonstrates that gas puffing is not efficient for core fuelling in H-modes and density control should be done by the high field side pellet injection in contrast to present machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Impacts of Battery Energy Storage System Functionalities on Distribution Systems Using Power Hardware in-the-Loop Simulation: Preprint

In this paper, we present results from a power hardware-in-the-loop (PHIL) simulation that was performed to test and demonstrate the impact of a battery energy storage system (BESS) on a distribution feeder. The PHIL platform includes a simulated distribution grid in a real-time digital simulator (RTDS), AC and DC power amplifiers, and a battery inverter as the device under test. Guidelines of specific procedures to set up a PHIL platform are provided on how to set up a PHIL platform to evaluate the impact of grid integrated systems. Accelerated time-series PHIL simulations of peak shaving and Volt/Var functionalities were performed using a 540 kVA BESS. These experimental results illustrate how PHIL simulations can be used to evaluate the impact of BESS functionalities on the distribution grid prior to installation in the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ADMS and DER Coordinated Capability Demonstrations to Assist Utilities to Increase Resilience and Reliability

The proliferation of distributed energy resources (DERs) presents opportunities and challenges to distribution grid operators. The National Renewable Energy Laboratory (NREL) and Survalent are collaborating to demonstrate advanced distribution management system (ADMS) and DER coordinated capability to assist utilities to increase resilience and reliability. ADMS and Distributed Energy Resource Management System (DERMS) Coordination for Peak Load Management (PLM). Fault Location, Isolation, and Service Restoration (FLISR) in the Presence of DERs. Grid-Edge Intelligent Distribution Automation System for Self-Healing Distribution Grids. These laboratory demonstrations use NREL's ADMS Test Bed.

ADMS↗

Protecting Intelligent Distributed Power Grids against Cyber Attacks

Like other industrial sectors, the electrical power industry is facing challenges involved with the increasing demand for interconnected operations and control. The electrical industry has largely been restructured due to deregulation of the electrical market and the trend of the Smart Grid. This moves new automation systems from being proprietary and closed to the current state of Information Technology (IT) being highly interconnected and open. However, while gaining all of the scale and performance benefits of IT, existing IT security challenges are acquired as well. The power grid automation network has inherent security risks due to the fact that the systems and applications for the power grid were not originally designed for the general IT environment. In this paper, we propose a conceptual layered framework for protecting power grid automation systems against cyber attacks. The following factors are taken into account: (1) integration with existing, legacy systems in a non-intrusive fashion; (2) desirable performance in terms of modularity, scalability, extendibility, and manageability; (3) alignment to the 'Roadmap to Secure Control Systems in the Energy Sector' and the future smart grid. The on-site system test of the developed prototype security system is briefly presented as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a networked hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAr regulation technologies as an example to illustrate system setups, communication requirements among different HIL simulation systems, and system connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

Xie, Fuhong↗

Data Privacy for the Grid: Toward a Data Privacy Standard for Inverter-Based and Distributed Energy Resources

The traditional approach to planning the distribution grid has focused on reliability in the context of gradual and reasonably predictable load growth. Forecasts of load growth, combined with asset management practices, were used by system planners to identify upgrades to the system to maintain or improve reliability. The decisions, typically based within load flow analysis tools, included considerations about contingency scenarios and corporate forecasts (i.e., top-down predictions at a summary level of what would happen in a particular area that could impact load growth and behavior). As a result, today, this traditional approach no longer fits all purposes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AI-Based Optimal Design and Controls Can Greatly Reduce Carbon Emissions and Enhance Resilience in Residential Communities in Cold Climates

Net-zero energy residential communities are crucial for achieving decarbonization goals, but the high-penetration photovoltaic (PV) in those communities is posing challenges to the distribution grid. Traditional design and operation of net-zero communities rely on rule-of-thumb methods and may not work in complex scenarios. Artificial intelligence and machine learning methods can optimally size PV for net-zero energy, identify user preferences and usage patterns, and fully unlock the potential of distributed energy resources to address distribution grid issues.

artificial intelligence↗

Cost and Efficiency Analysis for Hybrid AC/DC Distribution System Planning with PV and Battery

Distribution system planning is one of the main tasks for the electric utilities. Cost and energy efficiency are two main concerns in the distribution planning process. In this work, cost and efficiency analyses are conducted for the hybrid AC and DC distribution grids for the planning purposes. The IEEE 34-bus feeder has been applied for the case studies. The investment cost, operation and maintenance cost, replacement cost, etc., have been considered in the life cycle cost analysis. Power losses of both the AC and DC section are calculated with an open source simulation tool, the Open Distribution Simulator Software (OpenDSS). The proposed framework can be applied to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and help comparing different planning options.

AC/DC hybrid system planning↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

Joint Matrix Completion and Compressed Sensing for State Estimation in Low-observable Distribution System

Limited measurement availability at the distribution grid presents challenges for state estimation and situational awareness. This paper combines the advantages of two sparsity-based state estimation approaches (matrix completion and compressive sensing) that have been proposed recently to address the challenge of unobservability. The proposed approach exploits both the low rank structure and a suitable transform domain representation to leverage the correlation structure of the spatio-temporal data matrix while incorporating the powerflow constraints of the distribution grid. Simulations are carried out on three phase unbalanced IEEE 37 test system to verify the effectiveness of the proposed approach. The performance results reveal - (1) the superiority over traditional matrix completion and (2) very low state estimation errors for high compression ratios representing very low observability.

Dahale, Shweta↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗