Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Coherent lidar design and performance verification

The verification of LAWS beam alignment in space can be achieved by a measurement of heterodyne efficiency using the surface return. The crucial element is a direct detection signal that can be identified for each surface return. This should be satisfied for LAWS but will not be satisfied for descoped LAWS. The performance of algorithms for velocity estimation can be described with two basic parameters: the number of coherently detected photo-electrons per estimate and the number of independent signal samples per estimate. The average error of spectral domain velocity estimation algorithms are bounded by a new periodogram Cramer-Rao Bound. Comparison of the periodogram CRB with the exact CRB indicates a factor of two improvement in velocity accuracy is possible using non-spectral domain estimators. This improvement has been demonstrated with a maximum-likelihood estimator. The comparison of velocity estimation algorithms for 2 and 10 micron coherent lidar was performed by assuming all the system design parameters are fixed and the signal statistics are dominated by a 1 m/s rms wind fluctuation over the range gate. The beam alignment requirements for 2 micron are much more severe than for a 10 micron lidar. The effects of the random backscattered field on estimating the alignment error is a major problem for space based lidar operation, especially if the heterodyne efficiency cannot be estimated. For LAWS, the biggest science payoff would result from a short transmitted pulse, on the order of 0.5 microseconds instead of 3 microseconds. The numerically errors for simulation of laser propagation in the atmosphere have been determined as a joint project with the University of California, San Diego. Useful scaling laws were obtained for Kolmogorov atmospheric refractive turbulence and an atmospheric refractive turbulence characterized with an inner scale. This permits verification of the simulation procedure which is essential for the evaluation of the effects of refractive turbulence on coherent Doppler lidar systems. The analysis of 2 micron Doppler lidar data from Coherent Technologies, Inc. (CTI) has demonstrated many of the advantages of doppler lidar measurements of boundary layer winds. The effects of wind shear and wind turbulence over the pulse volume are probably the dominant source of the reduced performance. The effects of wind shear and wind turbulence on the statistical description of doppler lidar data has been derived and calculated.

Frehlich, Rod↗

The effect of clock, media, and station location errors on Doppler measurement accuracy

Doppler tracking by the Deep Space Network (DSN) is the primary radio metric data type used by navigation to determine the orbit of a spacecraft. The accuracy normally attributed to orbits determined exclusively with Doppler data is about 0.5 microradians in geocentric angle. Recently, the Doppler measurement system has evolved to a high degree of precision primarily because of tracking at X-band frequencies (7.2 to 8.5 GHz). However, the orbit determination system has not been able to fully utilize this improved measurement accuracy because of calibration errors associated with transmission media, the location of tracking stations on the Earth's surface, the orientation of the Earth as an observing platform, and timekeeping. With the introduction of Global Positioning System (GPS) data, it may be possible to remove a significant error associated with the troposphere. In this article, the effect of various calibration errors associated with transmission media, Earth platform parameters, and clocks are examined. With the introduction of GPS calibrations, it is predicted that a Doppler tracking accuracy of 0.05 microradians is achievable.

Miller, J. K.↗

Mass loss in the 96 day binary UU Cancri

A series of 16 high-dispersion spectra at H-alpha have been obtained for the tidally distorted K giant-containing long-period binary UU Cnc, in order to both study the K giant's Doppler profiles and search for the effects of accretion onto the second component. While Doppler profiles of the system for a semidetached configuration fit the observations very well, those for existing overcontact light-curve solutions all yield poorer fits. Although the H-alpha line is always stronger than those of the common giants, its equivalent width is consistent with a K4 II classification reflective of the star's 50 solar radius size. Emission wings in H-alpha are possible evidence for an accretion disk.

Eaton, Joel A.↗

Stark effect at the Si I series limit

Small redshifts and weakenings of high n lines in members of the Si series observed over a sunspot are interpreted as due to the Stark effect. Other origins, including Doppler motions, appear to be excluded. The spectra were obtained with high spatial resolution using the NRL high-resolution telescope and spectrograph. The origin of the Stark effect is not yet certain. An interpretation in terms of a quasi-static quadratic effect would require rather high perturber densities. An alternative interpretation would be a motional Stark effect, arising perhaps through the presence of magnetohydrodynamic waves.

Jordan, C.↗

Prospects for detection of gravitational radiation by simultaneous Doppler tracking of several spacecraft

This paper reports a calculation of the effect of gravitational radiation on the observed Doppler shift of a sinusoidal electromagnetic signal transmitted to, and coherently transponded from, distant spacecraft. It is found that the effect of plane gravitational waves on such observations is not intuitively immediate, and in fact depends sensitively on the spacecraft direction, which suggests the possibility of detecting such plane waves by simultaneous Doppler tracking of several spacecraft. The need for broad band gravitational wave observations, the required stabilities of time keeping standards, and astrophysical sources expected in the Very Low Frequency band are briefly discussed.

Estabrook, F. B.↗

Response of Doppler spacecraft tracking to gravitational radiation

A calculation is made of the effect of gravity waves on the observed Doppler shift of a sinusoidal electromagnetic signal transmitted to, and transponded from, a distant spacecraft. We find that the effect of plane gravity waves on such observations is not intuitively immediate and in fact can have surprisingly different spectral signatures for different spacecraft directions and distances. We suggest the possibility of detecting such plane waves by simultaneous coherent Doppler tracking of several spacecraft.

Estabrook, F. B.↗

Indoor Ground Testing of a Small UAS Sense and Avoid Airborne Doppler Radar

The National Aeronautics and Space Administration’s Unmanned Aircraft System (UAS) Traffic Management (UTM) project is researching prototype technologies needed to ensure safe integration of UAS operations into the National Airspace System (NAS). Within the UTM Concept of Operations, UAS would be equipped with on-board Sense and Avoid (SAA) technology to continually monitor for manned and unmanned aircraft in its vicinity while operating beyond visual line of sight in uncontrolled airspace. To support this effort, a candidate commercially available 24.5 GHz Doppler radar was selected and evaluated to determine if the technology could reliably support minimum requirements for SAA applications of small UAS (sUAS). Indoor ground tests were conducted inside the NASA Langley Research Center’s Experimental Test Range (ETR) from a stationary platform to evaluate the Doppler radar performance characteristics and gain operational proficiency before the radar was authorized to transmit outdoors. A high speed linear rail system was developed for the radar evaluation and was shown to be an effective method to generate Doppler radar targets of known radar cross section. The accuracy of the range and velocity reported by the radar was shown to be dependent on the Kalman filter state variance parameter settings. Antenna measurements were collected with the radar installed both on and off a sUAS to quantify the relative antenna gain, beam width and side lobe levels of the radar’s Metamaterial Electronically Scanning Array (MESA) antennas at boresight and extreme field of view pointing vectors. The relative antenna gain measured 2.6 dB lower at extreme field view angles compared to the boresight radiation pattern.

Szatkowski, George N.↗

Effects of volume averaging on the line spectra of vertical velocity from multiple-Doppler radar observations

Calculations of the ratio of the true one-dimensional spectrum of vertical velocity and that measured with multiple-Doppler radar beams are presented. It was assumed that the effects of pulse volume averaging and objective analysis routines is replacement of a point measurement with a volume integral. A u and v estimate was assumed to be feasible when orthogonal radars are not available. Also, the target fluid was configured as having an infinite vertical dimension, zero vertical velocity at the top and bottom, and having homogeneous and isotropic turbulence with a Kolmogorov energy spectrum. The ratio obtained indicated that equal resolutions among radars yields a monotonically decreasing, wavenumber-dependent response function. A gain of 0.95 was demonstrated in an experimental situation with 40 levels. Possible errors introduced when using unequal resolution radars were discussed. Finally, it was found that, for some flows, the extent of attenuation depends on the number of vertical levels resolvable by the radars.

Gal-Chen, T.↗

Effects of non-spherical drops on a phase Doppler spray analyzer

A phase/Doppler spray analyzer (P/DSA) and a laser imaging system was used to study the response of a P/DSA to nonspherical particles. Methanol particles with an aspect ratio ranging from 0.7 to 1.4 were used in this investigation. Results indicated that the P/DSA was quite sensitive to particle shape. A Berglund-Liu generator was used to produce particles of 98 microns (volumetric diameter). The P/DSA instrument measured particle sizes ranging from 142 microns for a particle of aspect ratio 0.7, to 84 microns for an aspect ratio of 1.4. Particle diameters based on averaged x and y diameters for the laser imaging system ranged from 95 microns to 92 microns over the same range of aspect ratios.

Alexander, D. R.↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tropospheric monitoring technology for gravity wave experiments

Tropospheric refractivity fluctuations are an important error source for gravity wave detection by Doppler tracking in that they alter the phase and phase rate of electromagnetic signals. Estimates are presented of the effect of tropospheric fluctuations on the Doppler signal and some examples are suggested of methods which minimize the effect. A model of the fluctuations is utilized to achieve those goals. Four possible methods for reducing the fluctuation effect are suggested: (1) observation and analysis strategies, which separate the atmospheric and gravity wave signatures; (2) water vapor radiometry for the wet component; (3) calibration using Global Positioning System (GPS) satellites; and (4) Doppler observations from multiple antennas to average fluctuation effects. The last two techniques could be used to calibrate both wet and dry fluctuations, or could be used in conjunction with water vapor radiometry to calibrate only the dry component.

Treuhaft, R. N.↗

A measurement of the general relativistic time delay with data from Mariners 6 and 7

The technique for obtaining range measurements is discussed. It involves measuring elapsed time between the transmission of an encoded signal from the ground station and its return from the spacecraft. The theoretical background for the Mariner Mars 1969 relativity test is presented, including computation of orbits and time transformation. Interplanetary and coronal plasma effects on range and Doppler observations at S-band are also considered. The general relativistic propagation delay was measured and a value of 0.997 for the relativity parameter Gamma star was obtained.

Anderson, J. D.↗

A symmetrical laser Doppler velocity meter and its application to turbulence characterization

A symmetrical method of optical heterodyning of the Doppler shifted scattered laser radiation developed for velocity measurements with a minimal instrumental spectral broadening and a high signal-to-noise ratio. The method employs two laser beams incident on the moving scatterer and does not use any reference beam for heterodyning. The Doppler signal frequency is independent of the scattering angle and the signal possesses no receiving aperture broadening. Optical alignment is simple. Typical values of the instrumental spectral broadening were approximately 0.8 percent of the center frequency of the Doppler signal, and the signal-to-noise ratio was approximately 25 dB, obtained from an air flow system using submicron dioctylphthalate scattering aerosol. Experimental and theoretical studies were made on the characteristics of the Doppler signal and the effect of system parameters in turbulent flow measurement. The optimization process involved in the beam optics and in the use of a spatial filter is described. For localized flow measurement in any direction of the three-dimensional orthogonal coordinates, the system, using uncorrected optical components, had a sensing volume which can be described by a sensitive length of 600 microns and a diameter of 100 microns.

Mazumder, M. K.↗