SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Radiation Dose Modeling for Niowave’s Accelerator Driven Uranium Target Assembly 3

Molybdenum-99 is a high-value radionuclide commonly used for medical purposes within the United States. The National Nuclear Security Administration (NNSA) seeks to reliably produce the radioisotope 99 Mo without the use of highly enriched uranium. NNSA’s Office of Material Management and Minimization (M3) provides funding and government laboratory expertise to private companies to expedite the production process domestically and currently funds designs that use low-enriched uranium or other 99 Mo production pathways. Several production designs are being explored across the industry, including uranium fission and photonuclear conversion of 100 Mo targets. Niowave Inc. seeks to produce 99 Mo via a high-energy electron accelerator that strikes a lead-bismuth eutectic target that ultimately produces a consistent neutron flux. The neutron flux then interacts in a subcritical reactor core configuration to produce fission in low-enriched or natural uranium targets. These fissionable targets are then processed to extract 99 Mo. The purpose of this work is to estimate the neutron and photon dose response across Niowave’s proposed facility for worker safety during operation. Owing to the size of the proposed Niowave facility and necessary shielding, unbiased Monte Carlo radiation transport is impractical, and variance reduction methods are required. This work focuses on the weight window variance reduction method to produce high confidence dose response results within a Monte Carlo radiation transport code. Specifically, an adjoint-informed weight window methodology was created to improve the dose response estimates for accelerator-driven subcritical reactor designs. This adjoint-informed methodology was implemented for Niowave’s proposed design and improved dose results at far-field locations across the facility. Acceptable dose rate contours for the proposed facility were generated across the facility and are presented in this work.

07 ISOTOPE AND RADIATION SOURCES↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

SU-G-TeP3-13: The Role of Nanoscale Energy Deposition in the Development of Gold Nanoparticle-Enhanced Radiotherapy

Purpose: Gold nanoparticles (GNPs) can enhance radiotherapy effects. The high photoelectric cross section of gold relative to tissue, particularly at lower energies, leads to localized dose enhancement. However in a clinical context, photon energies must also be sufficient to reach a target volume at a given depth. These properties must be balanced to optimize such a therapy. Given that nanoscale energy deposition patterns around GNPs play a role in determining biological outcomes, in this work we seek to establish their role in this optimization process. Methods: The PENELOPE Monte Carlo code was used to generate spherical dose deposition kernels in 1000 nm diameter spheres around 50 nm diameter GNPs in response to monoenergetic photons incident on the GNP. Induced “lesions” were estimated by either a local effect model (LEM) or a mean dose model (MDM). The ratio of these estimates was examined for a range of photon energies (10 keV to 2 MeV), for three sets of linear-quadratic parameters. Results: The models produce distinct differences in expected lesion values, the lower the alpha-beta ratio, the greater the difference. The ratio of expected lesion values remained constant within 5% for energies of 40 keV and above across all parameter sets and rose to a difference of 35% for lower energies only for the lowest alpha-beta ratio. Conclusion: Consistent with other work, these calculations suggest nanoscale energy deposition patterns matter in predicting biological response to GNP-enhanced radiotherapy. However the ratio of expected lesions between the different models is largely independent of energy, indicating that GNP-enhanced radiotherapy scenarios can be optimized in photon energy without consideration of the nanoscale patterns. Special attention may be warranted for energies of 20 keV or below and low alpha-beta ratios.

60 APPLIED LIFE SCIENCES↗

Comparison of residual dose rates from MARS and DORIAN simulations with experimental data from the SINBAD database

This benchmarking study aims to compare residual dose rate predictions from the MARS and DORIAN codes with experimental measurements taken from samples irradiated at CERN's CERF facility. The research evaluates the residual dose rates of these samples over varied cooling intervals. Additionally, it delves into the influence of parameter choices, such as specific physics processes and energy thresholds, on the production and transport of particles and their effects on simulation outcomes. While both MARS and DORIAN largely align with experimental findings, discrepancies were observed in the copper sample. This prompted an in-depth examination of the elevated dose rates from MARS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing uncertainty in personnel dosimetry calculations in the VHTR plant using MAVRIC

This work analyzes the efficacy of the MAVRIC sequence of the Scale 6.1 code package with respect to the accuracy of results and the ability to utilize large-memory, parallel machines. MAVRIC implements the hybrid FW-CADIS methodology to solve neutron and photon transport for shielding applications. Using the discrete ordinates method to solve the Boltzmann transport equation, an importance map is generated which MAVRIC then uses to bias a stochastic Monte Carlo simulation. The MAVRIC sequence is applied to generate neutron and photon dose rate distributions of improved accuracy in a model of a proposed VHTR power plant. Problems like this one, with a size on the order of magnitude of a nuclear power plant, require a prohibitive amount of memory to store complete importance maps. The issue is addressed by refining the mesh in areas around the source through the detector regions, while leaving a coarse mesh elsewhere. Additionally through the use of parallel computing, the angular flux can be expanded in higher quadrature sets, which leads to a better importance map while requiring no extra memory requirements during the Monte Carlo portion of the sequence. The final Monte Carlo simulations can be run concurrently on several machines with results combined after the fact, emulating parallelism that is not yet available in MAVRIC sequence. Using a combination of strategies, the MAVRIC sequence is shown to be able to scale across available computational resources, allowing the user to more quickly obtain Monte Carlo results with lower relative uncertainties in large, deep-penetration shielding problems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-122: Dosimetric Comparison Between Cone, HDMLC and MicroMLC for the Treatment of Trigeminal Neuralgia

Purpose: The purpose of this work was to evaluate the dosimetric characteristics of three collimation systems, 5mm circular cone (Brainlab) and square fields of 5mm with HDMLC (Varian) and microMLC Moduleaf, Siemens) for trigeminal neuralgia treatment. Methods: A TPS Iplan v4.5 BrainLAB was used to do treatment plans for each collimations system in a square solid water phantom with isocenter at 5cm depth. Single field and treatment plan including 11 arcs with fix field and 100° gantry range was made for each collimation systems. EBT3 films were positioned at isocenter in a coronal plane to measured dose distribution for all geometries. Films were digitized with a Vidar DosimetryPro Red scanner with a resolution of 89dpi and RIT113v6.1 software was used for analysis. Penumbra region (80%–20%), FWHM and dose percentage at 5mm and 10mm from CAX were determined. All profiles were normalized at CAX. Results: For single beam the penumbra (FWHM) was 1.5mm (5.3mm) for the cone, 1.9mm (5.5mm) for HDMLC and 1.8mm (5.4mm) for the microMLC. Dose percentage at 5mm was 6.9% for cone, 12.5% for HDMLC and 8.7% for the microMLC. For treatment plan the penumbra (FWHM) was 2.58mm (5.47mm) for the cone, 2.8mm (5.84mm) for HDMLC and 2.58mm (6.09mm) for the microMLC. Dose perecentage at 5mm was 13.1% for cone, 16.1% for HDMLC, 15.2% for the microMLC. Conclusion: The cone has a dose falloff larger than the microMLC and HDMLC, by its reduced penumbra, this translates into better protection of surrounding healthy tissue, however, the microMLC and HDMLC have similar accuracy to cone.

60 APPLIED LIFE SCIENCES↗

SU-E-T-102: Determination of Dose Distributions and Water-Equivalence of MAGIC-F Polymer Gel for 60Co and 192Ir Brachytherapy Sources

Purpose: Analyse the water-equivalence of MAGIC-f polymer gel for {sup 60}Co and {sup 192}Ir clinical brachytherapy sources, through dose distributions simulated with PENELOPE Monte Carlo code. Methods: The real geometry of {sup 60} (BEBIG, modelo Co0.A86) and {sup 192}192Ir (Varian, model GammaMed Plus) clinical brachytherapy sources were modelled on PENELOPE Monte Carlo simulation code. The most probable emission lines of photons were used for both sources: 17 emission lines for {sup 192}Ir and 12 lines for {sup 60}. The dose distributions were obtained in a cubic water or gel homogeneous phantom (30 × 30 × 30 cm{sup 3}), with the source positioned in the middle of the phantom. In all cases the number of simulation showers remained constant at 10{sup 9} particles. A specific material for gel was constructed in PENELOPE using weight fraction components of MAGIC-f: wH = 0,1062, wC = 0,0751, wN = 0,0139, wO = 0,8021, wS = 2,58×10{sup −6} e wCu = 5,08 × 10{sup −6}. The voxel size in the dose distributions was 0.6 mm. Dose distribution maps on the longitudinal and radial direction through the centre of the source were used to analyse the water-equivalence of MAGIC-f. Results: For the {sup 60} source, the maximum diferences in relative doses obtained in the gel and water were 0,65% and 1,90%, for radial and longitudinal direction, respectively. For {sup 192}Ir, the maximum difereces in relative doses were 0,30% and 1,05%, for radial and longitudinal direction, respectively. The materials equivalence can also be verified through the effective atomic number and density of each material: Zef-MAGIC-f = 7,07 e .MAGIC-f = 1,060 g/cm{sup 3} and Zef-water = 7,22. Conclusion: The results showed that MAGIC-f is water equivalent, consequently being suitable to simulate soft tissue, for Cobalt and Iridium energies. Hence, gel can be used as a dosimeter in clinical applications. Further investigation to its use in a clinical protocol is needed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-253: Development of a GDPM Monte Carlo Based Quality Assurance Tool for Cyberknife

Purpose: To develop a 3D quality assurance (QA) tool for Cyberknife plans using a GPU-based Monte Carlo dose calculation package, gDPM. The developed QA tool will be used as a secondary check for Cyberknife treatment planning software (TPS) reported dose distributions. Methods: Phase space files of the 5, 7.5, 10, 15, and 60 mm iris cones were downloaded from IAEA phase-space database. From the 60mm iris cone phase space file, we were able to generate raw phase space files for all other cones using a particle rejection method. The particles in the raw phase space files were binned with respect to the radial position and energy for commissioning. During the commissioning process, gDPM calculated percent depth dose and off-center ratios which were compared to those measured in the Blue Phantom. The off-axis data was measured with an SAD setup at depths of 15, 50, 100, 200, and 300 mm. At the commissioning stage, an optimization problem was solved to adjust the binned particles weights to minimize the difference between the calculated and measured ones. Commissioning validations will be performed by measuring point dose data of patient specific plans delivered to water phantoms. With commissioned phase space files, 3D patient-specific dose distributions will be calculated and compared against TPS reported dose. Results: Beyond the initial buildup region, the root mean square difference between the calculated and measured percent depth dose differences was less than 0.5%. The full-width half-max data from the off-axis ratio calculations was found to be within 0.1 mm of the measured data. Conclusion: Our current work showed excellent agreement between the gDPM calculated dose and the measured data for all cone sizes and types for the Cyberknife system. Implementation of a fast and accurate QA tool for patient specific plans will be feasible with this tool.

60 APPLIED LIFE SCIENCES↗

Update of the Nuclear Criticality Slide Rule Calculations: Plutonium systems – Delayed Fission Gamma

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents results from the fourth phase of the current update of the Slide Rule project, in which delayed fission-product gamma (DFG) dose rates of unreflected plutonium critical systems were compared by several modern 3D radiation transport codes (MCNP, COG, SCALE), using updated flux-to-dose conversion factors. Dose rates are calculated for fissile material at five moderation ratios (H/Pu), at 1 m above the ground as a function of distance (between 30 cm and 1,200 m) from the external surface of the source to the center of the detector, and for periods between 1 s and 1,000 min after the critical instantaneous event. Further efforts have been devoted to the determination of the delayed gamma source, by comparing the time-dependent energy spectra obtained from several methods. Overall, DFG dose rates calculated by each participant led to consistent results. Extra effort is under way to identify the cause of the remaining differences, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Sensitivity of α/β Prediction to Dose Calculation Methodology in Prostate Brachytherapy

Purpose: To study the relationship between the accuracy of the dose calculation in brachytherapy and the estimations of the radiosensitivity parameter, α/β, for prostate cancer. Methods and Materials: In this study, Monte Carlo methods and more specifically the code ALGEBRA was used to produce accurate dose calculations in the case of prostate brachytherapy. Equivalent uniform biologically effective dose was calculated for these dose distributions and was used in an iso-effectiveness relationship with external beam radiation therapy. Results: By considering different levels of detail in the calculations, the estimation for the α/β parameter varied from 1.9 to 6.3 Gy, compared with a value of 3.0 Gy suggested by the American Association of Physicists in Medicine Task Group 137. Conclusions: Large variations of the α/β show the sensitivity of this parameter to dose calculation modality. The use of accurate dose calculation engines is critical for better evaluating the biological outcomes of treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-92: Clinical Benefit for Breast and Chest Wall Setup in Using a Breast Board

Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co-registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Which were brought back to the planning CT data set though the initial rigid co-registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real-time patient position monitoring is clinically desired.

60 APPLIED LIFE SCIENCES↗

SU-F-T-115: Uncertainty in the Esophagus Dose in Retrospective Epidemiological Study of Breast Cancer Radiotherapy Patients

Purpose: Epidemiological studies of second cancer risks in breast cancer radiotherapy patients often use generic patient anatomy to reconstruct normal tissue doses when CT images of patients are not available. To evaluate the uncertainty involved in the dosimetry approach, we evaluated the esophagus dose in five sample patients by simulating breast cancer treatments. Methods: We obtained the diagnostic CT images of five anonymized adult female patients in different Body Mass Index (BMI) categories (16– 36kg/m2) from National Institutes of Health Clinical Center. We contoured the esophagus on the CT images and imported them into a Treatment Planning System (TPS) to create treatment plans and calculate esophagus doses. Esophagus dose was calculated once again via experimentally-validated Monte Carlo (MC) transport code, XVMC under the same geometries. We compared the esophagus doses from TPS and the MC method. We also investigated the degree of variation in the esophagus dose across the five patients and also the relationship between the patient characteristics and the esophagus doses. Results: Eclipse TPS using Analytical Anisotropic Algorithm (AAA) significantly underestimates the esophagus dose in breast cancer radiotherapy compared to MC. In the worst case, the esophagus dose from AAA was only 40% of the MC dose. The Coefficient of Variation across the patients was 48%. We found that the maximum esophagus dose was up to 2.7 times greater than the minimum. We finally observed linear relationship (Dose = 0.0218 × BMI – 0.1, R2=0.54) between patient’s BMI and the esophagus doses. Conclusion: We quantified the degree of uncertainty in the esophagus dose in five sample breast radiotherapy patients. The results of the study underscore the importance of individualized dose reconstruction for the study cohort to avoid misclassification in the risk analysis of second cancer. We are currently extending the number of patients up to 30.

60 APPLIED LIFE SCIENCES↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Evaluation of Simplified Models for Estimating Public Dose from Spent Nuclear Fuel Shipments

This paper investigates the dose rate as a function of distance from a representative high-capacity SNF rail-type transportation cask. It uses the SCALE suite of radiation transport modeling and simulation codes to determine neutron and gamma radiation dose rates. The SCALE calculated dose rate is compared with simplified analytical methods historically used for these calculations. The SCALE dose rate calculation presented in this paper employs a very detailed transportation cask model (e.g., pin-by-pin modeling of fuel assembly) and a new hybrid computational transport method. Because it includes pin-level heterogeneity and models ample air and soil outside the cask to simulate scattering of gamma and neutron radiation, this detailed SCALE model is expected to yield more accurate results than previously used models which made more simplistic assumptions (e.g., fuel assembly treated as a point or line source, simple 1-D model of environment outside of cask). The results in this paper are preliminary and, as progress is made on developing and validating improved models, results may be subject to change as models and estimates become more refined and better information leads to more accurate assumptions.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-FG-BRA-01: 4D Monte Carlo Simulations for Verification of Dose Delivered to a Moving Anatomy

Purpose: To validate 4D Monte Carlo (MC) simulations of dose delivery by an Elekta Agility linear accelerator to a moving phantom. Methods: Monte Carlo simulations were performed using the 4DdefDOSXYZnrc/EGSnrc user code which samples a new geometry for each incident particle and calculates the dose in a continuously moving anatomy. A Quasar respiratory motion phantom with a lung insert containing a 3 cm diameter tumor was used for dose measurements on an Elekta Agility linac with the phantom in stationary and moving states. Dose to the center of tumor was measured using calibrated EBT3 film and the RADPOS 4D dosimetry system. A VMAT plan covering the tumor was created on the static CT scan of the phantom using Monaco V.5.10.02. A validated BEAMnrc model of our Elekta Agility linac was used for Monte Carlo simulations on stationary and moving anatomies. To compare the planned and delivered doses, linac log files recorded during measurements were used for the simulations. For 4D simulations, deformation vectors that modeled the rigid translation of the lung insert were generated as input to the 4DdefDOSXYZnrc code as well as the phantom motion trace recorded with RADPOS during the measurements. Results: Monte Carlo simulations and film measurements were found to agree within 2mm/2% for 97.7% of points in the film in the static phantom and 95.5% in the moving phantom. Dose values based on film and RADPOS measurements are within 2% of each other and within 2σ of experimental uncertainties with respect to simulations. Conclusion: Our 4D Monte Carlo simulation using the defDOSXYZnrc code accurately calculates dose delivered to a moving anatomy. Future work will focus on more investigation of VMAT delivery on a moving phantom to improve the agreement between simulation and measurements, as well as establishing the accuracy of our method in a deforming anatomy. This work was supported by the Ontario Consortium of Adaptive Interventions in Radiation Oncology (OCAIRO), funded by the Ontario Research Fund Research Excellence program.

60 APPLIED LIFE SCIENCES↗