The arcing rate for a High Voltage Solar Array - Theory, experiment and predictions

All solar arrays have biased surfaces which can be exposed to the space environment. It has been observed that when the array bias is less than a few hundred volts negative then the exposed conductive surfaces may undergo arcing in the space plasma. A theory for arcing is developed on these high voltage solar arrays which ascribes the arcing to electric field runaway at the interface of the plasma, conductor and solar cell dielectric. Experiments were conducted in the laboratory for the High Voltage Solar Array (HVSA) experiment which will fly on the Japanese Space Flyer Unit (SFU) in 1994. The theory was compared in detail to the experiment and shown to give a reasonable explanation for the data. The combined theory and ground experiments were then used to develop predictions for the SFU flight.

Hastings, Daniel E.↗

Arcing rates for High Voltage Solar Arrays - Theory, experiment, and predictions

All solar arrays have biased surfaces that can be exposed to the space environment. It has been observed that when the array bias is less than a few hundred volts negative, then the exposed conductive surfaces may undergo arcing in the space plasma. A theory for arcing is developed on these high voltage solar arrays that ascribes the arcing to electric field runaway at the interface of the plasma, conductor, and solar cell dielectric. Experiments were conducted in the laboratory for the High Voltage Solar Array experiment that will fly on the Japanese Space Flyer Unit (SFU) in 1994. The theory was compared in detail with the experiment and shown to give a reasonable explanation for the data. The combined theory and ground experiments were then used to develop predictions for the SFU flight.

Hastings, Daniel E.↗

Electrophoretic Deposition on Porous Non-Conductors

A method of electrophoretic deposition (EPD) on substrates that are porous and electrically non-conductive has been invented. Heretofore, in order to perform an EPD, it has been necessary to either (1) use a substrate material that is inherently electrically conductive or (2) subject a non-conductive substrate to a thermal and/or chemical treatment to render it conductive. In the present method, instead of relying on the electrical conductivity of the substrate, one ensures that the substrate is porous enough that when it is immersed in an EPD bath, the solvent penetrates throughout the thickness, thereby forming quasi-conductive paths through the substrate. By making it unnecessary to use a conductive substrate, this method simplifies the overall EPD process and makes new applications possible. The method is expected to be especially beneficial in enabling deposition of layers of ceramic and/or metal for chemical and electrochemical devices, notably including solid oxide fuel cells.

Compson, Charles↗

Overvoltage protection network

Electrical equipment to be protected from overvoltage is connected with a possible source of overvoltage via an input conductor. A fuse is connected in series with the input conductor. A spark gap is connected between the input conductor and ground for conducting the overvoltage current to ground and for blowing the fuse to open the circuit to the electrical equipment. A pulse attenuator network is provided between the spark gap and the electrical equipment to be protected for attenuating the pulse of energy passing through the fuse and spark gap prior to blowing of the fuse. The pulse attenuator network includes additional shunt spark gaps, series inductance, and a series connection of a twisted shielded pair of conductors having low-voltage insulation.

Cambra, J. M.↗

Helmholtz Motor: A Novel Electric Machine That Enables High Temperature Superconducting Armatures

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Cryogenic electric machines are a promising technology for multi megawatt electric aircraft drivetrains. Second generation high temperature superconductors (HTS) are the ideal conductor for the field winding (typically the rotor) of superconducting machines, and they have attractive features for the armature winding (typically the stator) of these machines. However, their use in armature windings has been severely limited due to excessive AC losses in conventional electric machines. This presentation will present the working principle, design, and a performance trade study of a novel electric machine – termed a Helmholtz machine – that enables HTS armatures by significantly reducing AC losses. The working principle of the patent pending Helmholtz motor is to optimize the rotor-produced magnetic field (i.e., the field winding) so that it produces a magnetic field almost purely in the plane of the HTS. This is accomplished using 2 rotors that contain a set of matched Helmholtz coil pairs (or matched permanent magnet Halbach arrays). The armature (stator) HTS coils are positioned between the rotors and oriented to minimize the out of plane magnetic field. The armature HTS coils are also designed to minimize the out of plane component of their self field. The presentation will include the lessons learned in the sizing and design of this motor, including equations for how to match the magnet arrays. A performance trade study will be presented for a partially superconducting, radial flux version of the motor. The trade study involved an optimization of a motor design code based on analytical calculations (electromagnetic, AC loss, thermofluid, mechanical, and motor sizing) that determine the motor’s total efficiency and total specific power. The design code will be described in the presentation, with an emphasis on the calculation of magnetic fields, AC loss, and temperature distribution.

Superconducting electric machines↗

NASA Electric Aircraft Testbed (NEAT) Single-Aisle Transport Air Vehicle Hybrid Electric Tail-Cone Thruster Powertrain Configuration and Test Results

A key technical challenge is to establish a viable concept for a MW-class hybrid gas-electric propulsion system for a commercial transport aircraft. This includes developing aircraft propulsion system conceptual designs, integrating sub-systems, high efficiency/power density electric machines, flight-weight power system and electronics, and enabling materials in high voltage insulation, high frequency soft magnetics, and conductors. The primary benefit of this research is to diversify the current turbofan propulsion options to include hybrid electric propulsion elements that reduce energy usage, emissions, and noise. A reconfigurable powertrain testbed at NASA Glenn Research Center is described including test results from the initial 500 kW powertrain configuration.

Dyson, Rodger W.↗

NASA Electric Aircraft Testbed Single-Aisle Transport Air Vehicle Hybrid Electric Tail-Cone Thruster Powertrain Configuration and Test Results

A key technical challenge is to establish a viable concept for a MW-class hybrid gas-electric propulsion system for a commercial transport aircraft. This includes developing aircraft propulsion system conceptual designs, integrating sub-systems, high efficiency/power density electric machines, flight-weight power system and electronics, and enabling materials in high voltage insulation, high frequency soft magnetics, and conductors. The primary benefit of this research is to diversify the current turbofan propulsion options to include hybrid electric propulsion elements that reduce energy usage, emissions, and noise.

Dyson, Rodger↗

An active magnetic bearing with high T(sub c) superconducting coils and ferromagnetic cores

A proof-of-feasibility demonstration showed that high-T(sub c) superconductor (HTS) coils can be used in a high-load, active magnetic bearing in LN2. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 890 N (200 lb) radial load capacity (measured non-rotatings) and supported a shaft to 14,000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that for Cu in LN2. The bias coil, wound with non-twisted, multifilament HTS conductor, dissipated negligible power for its direct current. The control coils, wound with monofilament HTS sheathed in Ag, dissipated negligible power for direct current. AC losses increased rapidly with frequency and quadratically with AC amplitude. Above about 2 Hz, the effective resistance of the control coils exceeds that of the silver which is in electrical parallel with the oxide superconductor. These results show that twisted multifilament conductor is not needed for stable levitation but may be desired to reduce control power for sizable dynamic loads.

Brown, G. V.↗

High-temperature electric stator

Thermal vacuum tests are conducted on high-temperature stator without a rotor. Electrical characteristics remained satisfactory during tests, insulation improved slightly, and conductor resistance remained constant. The assembly included a bore seal for hermetically sealing the stator from the rotor cavity.

Kueser, P.↗

Low partial discharge vacuum feedthrough

Relatively discharge free vacuum feedthrough uses silver-plated copper conductor jacketed by carbon filled silicon semiconductor to reduce concentrated electric fields and minimize occurrence of partial discharge.

Benham, J. W.↗

Electro-Optic Lightning Detector

Electric field measurements are fundamental to the study of thunderstorm electrification, thundercloud charge structure, and the determination of the locations and magnitudes of charges deposited by lightning. Continuous field observations can also be used to warn of impending electrical hazards. For example, the USAF Eastern Range (ER) and NASA Kennedy Space Center (KSC) in Florida currently operate a ground-based network of electric field mill sensors to warn against lightning hazards to space vehicle operations/launches. The sensors provide continuous recordings of the ambient field. Others investigators have employed flat-plate electric field antennas to detect changes In the ambient field due to lightning. In each approach, electronic circuitry is used to directly detect and amplify the effects of the ambient field on an exposed metal conductor (antenna plate); in the case of continuous field recordings, the antenna plate is alternately shielded and unshielded by a grounded conductor. In this work effort, an alternate optical method for detecting lightning-caused electric field changes is Introduced. The primary component in the detector is an anisotropic electro-optic crystal of potassium di-hydrogen phosphate (chemically written as KH2PO4 (KDP)). When a voltage Is placed across the electro-optic crystal, the refractive Indices of the crystal change. This change alters the polarization state of a laser light beam that is passed down the crystal optic axis. With suitable application of vertical and horizontal polarizers, a light transmission measurement is related to the applied crystal voltage (which in turn Is related to the lightning caused electric field change). During the past two years, all critical optical components were procured, assembled, and aligned. An optical housing, calibration set-up, and data acquisition system was integrated for breadboard testing. The sensor was deployed at NASA Marshall Space Flight Center (MSFC) in the summer of 1998 to collect storm data. Because solid-state technology is used, future designs of the sensor will be significantly scaled down In physical dimension and weight compared to the present optical breadboard prototype. The use of fiber optics would also provide significant practical improvements.

Koshak, William J.↗

Re-Architecting the NASA Wire Derating Approach

• Design of wiring for aerospace vehicles relies on an understanding of “ampacity,” which refers to the current carrying capacity of wires, individually or in wire bundles. • Designers rely on standards to derate allowable current flow to prevent exceedance of wire temperature limits due to resistive heat dissipation within the wires or wire bundles. Designers select wire sizing and circuit protective device settings/sizing based on the standards. • Exceeding the wire temperature rating can result in electrical, physical, and/or chemical degradation of the wiring insulation and conductor which could lead to a catastrophic failure. • These standards can add considerable margin, in some cases underestimate the margin and are based on empirical data that is no longer available for review.

Steven L Rickman↗

Using G4FETs as a Data Router for In-Plane Crossing of Signal Paths

Theoretical analysis and some experiments have demonstrated that siliconon- insulator (SOI) 4-gate transistors the type known as G(exp 4)FETs could be efficiently used for in-plane crossing of signal paths. Much of the effort of designing very-large-scale integrated (VLSI) circuits is focused on area-efficient routing of signals. The main source of difficulty in VLSI signal routing is the requirement to prevent crossing, in the same plane, of wires that are meant to be kept electrically insulated from each other. Consequently, it often becomes necessary to design and build VLSI circuits in multiple layers with vias (connections between conductors in different layers at selected locations). Suitable devices that would prevent, or at least sufficiently suppress, undesired electrical coupling (cross-talk) between wires crossing in the same plane would enable compact, simpler implementation complex interconnection networks with in-plane crossings that, heretofore, have not been possible in VLSI circuitry. The use of G4FETs as in-plane signal-crossing devices or routers, in combination with the use of G(exp 4)FETs as universal programmable logic gates, would create opportunities for reducing complexity in VLSI design.

Fijany, Amir↗

A probabilistic analysis of electrical equipment vulnerability to carbon fibers

The statistical problems of airborne carbon fibers falling onto electrical circuits were idealized and analyzed. The probability of making contact between randomly oriented finite length fibers and sets of parallel conductors with various spacings and lengths was developed theoretically. The probability of multiple fibers joining to bridge a single gap between conductors, or forming continuous networks is included. From these theoretical considerations, practical statistical analyses to assess the likelihood of causing electrical malfunctions was produced. The statistics obtained were confirmed by comparison with results of controlled experiments.

Elber, W.↗

Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

Jeffries, K. S.↗

Packaging Technology Developed for High-Temperature Silicon Carbide Microsystems

High-temperature electronics and sensors are necessary for harsh-environment space and aeronautical applications, such as sensors and electronics for space missions to the inner solar system, sensors for in situ combustion and emission monitoring, and electronics for combustion control for aeronautical and automotive engines. However, these devices cannot be used until they can be packaged in appropriate forms for specific applications. Suitable packaging technology for operation temperatures up to 500 C and beyond is not commercially available. Thus, the development of a systematic high-temperature packaging technology for SiC-based microsystems is essential for both in situ testing and commercializing high-temperature SiC sensors and electronics. In response to these needs, researchers at Glenn innovatively designed, fabricated, and assembled a new prototype electronic package for high-temperature electronic microsystems using ceramic substrates (aluminum nitride and aluminum oxide) and gold (Au) thick-film metallization. Packaging components include a ceramic packaging frame, thick-film metallization-based interconnection system, and a low electrical resistance SiC die-attachment scheme. Both the materials and fabrication process of the basic packaging components have been tested with an in-house-fabricated SiC semiconductor test chip in an oxidizing environment at temperatures from room temperature to 500 C for more than 1000 hr. These test results set lifetime records for both high-temperature electronic packaging and high-temperature electronic device testing. As required, the thick-film-based interconnection system demonstrated low (2.5 times of the room-temperature resistance of the Au conductor) and stable (decreased 3 percent in 1500 hr of continuous testing) electrical resistance at 500 C in an oxidizing environment. Also as required, the electrical isolation impedance between printed wires that were not electrically joined by a wire bond remained high (greater than 0.4 GW) at 500 C in air. The attached SiC diode demonstrated low (less than 3.8 W/mm2) and relatively consistent dynamic resistance from room temperature to 500 C. These results indicate that the prototype package and the compatible die-attach scheme meet the initial design standards for high-temperature, low-power, and long-term operation. This technology will be further developed and evaluated, especially with more mechanical tests of each packaging element for operation at higher temperatures and longer lifetimes.

Chen, Liang-Yu↗

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY↗