Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Discovery-Class Lunette Mission Concept for a Lunar Geophysical Network

The Lunette mission concept for a network of small, inexpensive lunar landers has evolved over the last three years as the focus of space exploration activities in the US has changed. Originating in a concept for multiple landers launched as a secondary payload capable of regional science and site survey activities, Lunette has recently been developed into a Discovery-class mission concept that offers global lunar coverage enabling network science on a much broader scale. A particular mission concept has been refined by the Lunette team that would result in a low-cost global lunar geophysical network, comprised of two landers widely spaced on the near side of the moon. Each of the two identical landers would carry a suite of instruments that would make continuous measurements of seismic activity, heat flow, and the electromagnetic environment during the full lunar day/night cycle. Each lander would also deploy a next-generation laser retroreflector capable of improving on distance measurement accuracy by an order of magnitude over those emplaced by the previous Apollo and Lunokhod missions. This paper presents a comprehensive overview of the Lunette geophysical network mission concept, including mission and flight system design, as well as the key requirements and constraints that guided them.

Elliott, John↗

Parametric Cost Model for Ground and Space Telescopes

Parametric cost models can be used by designers and project managers to compare cost between major architectural cost drivers and allow high-level design trades; enable cost-benefit analysis for technology development investment; and, provide a basis for estimating total project cost between related concepts. The NASA Marshall Space Flight Center has developed a 5-parameter first-article optical telescope assembly cost model OTA$ (FY17) = $20M x 30(S/G)x D(1.7)x λ(-0.5)x T(-0.25)x e(-0.028) (Y-1960)Where S/G = 1 for space and 0 for ground telescopes, D = diameter, λ= diffraction limited wavelength, T = operating temperature and Y = year of development. The model explains 92% (Adjusted R2) of the cost variation in a database of 47 total ground and space telescope assemblies (OTA). The MSFC model estimates the most likely cost for only the OTA. Where an OTA is defined as the subsystem which collects electromagnetic radiation and focuses it (focal) or concentrates it (afocal) into the science instruments. An OTA consists of the primary mirror, secondary mirror, auxiliary optics and support structure (such as optical bench or truss structure, primary support structure, secondary support structure or spiders, straylight baffles, mechanisms for adjusting the optical components, electronics or power systems for operating these mechanisms, etc.). Finally, duplication only reduces cost for the manufacture of identical systems(i.e. multiple aperture sparse arrays or interferometers). And, while duplication does reduce the cost of manufacturing the mirrors of segmented primary mirror, this cost savings does not appear to manifest itself in the final primary mirror assembly(presumably because the structure for a segmented mirror is more complicated than for a monolithic mirror).

Space Telescope Cost Model, Parametric Cost Model↗

Development of an interpretive simulation tool for the proton radiography technique

Proton radiography is a useful diagnostic of high energy density (HED) plasmas under active theoretical and experimental development. In this paper, we describe a new simulation tool that interacts realistic laser-driven point-like proton sources with three dimensional electromagnetic fields of arbitrary strength and structure and synthesizes the associated high resolution proton radiograph. The present tool’s numerical approach captures all relevant physics effects, including effects related to the formation of caustics. Electromagnetic fields can be imported from particle-in-cell or hydrodynamic codes in a streamlined fashion, and a library of electromagnetic field “primitives” is also provided. This latter capability allows users to add a primitive, modify the field strength, rotate a primitive, and so on, while quickly generating a high resolution radiograph at each step. In this way, our tool enables the user to deconstruct features in a radiograph and interpret them in connection to specific underlying electromagnetic field elements. We show an example application of the tool in connection to experimental observations of the Weibel instability in counterstreaming plasmas, using ∼10{sup 8} particles generated from a realistic laser-driven point-like proton source, imaging fields which cover volumes of ∼10 mm{sup 3}. Insights derived from this application show that the tool can support understanding of HED plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct tests of a pixelated microchannel plate as the active element of a shower maximum detector

One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. As a result, a method for measuring the arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Considerations for Secure Wireless Sensor Communication Systems in Harsh Electromagnetic Environments of Nuclear Reactor Facilities

Wireless sensors can potentially play a significant role in safety, efficiency, and reliability of the instrumentation and control process in current and next generation nuclear power reactors. While conventional narrowband wireless sensors have shown a certain level of success in some nuclear power plants (NPPs), the radio frequency (RF) propagation challenges posed by the heavy metallic and cluttered environment of NPPs has prevented their widespread use in such operations. Furthermore, these challenges include RF wave propagation in harsh (reflective, absorptive, cluttered) environments, data security issues, and RF interference to and from other devices in the vicinity of a nuclear reactor core. In this paper, first we address how ultrawideband (UWB) RF technology can complement the narrowband (i.e., WiFi) solutions that have been used in some NPPs by providing an alternative solution in addressing the signal propagation issues in such electromagnetically harsh environments. Second, we discuss and present the UWB software simulation results on multipath harsh environments, and then address the data security issues. In the final sections of the paper, we present the experimental results of using UWB signaling in a representative harsh environment conducted at the Massachusetts Institute of Technology research reactor site. We plan to develop the UWB communications hardware based on the results of this paper and report on its performance in the field with emphasis on the security aspects of the system in a subsequent paper.

42 ENGINEERING↗

A conceptual design of an electron spectrometer for ELI-NP

We present the geometry and field parameters of an Electron Spectrometer (ES) with two dipole magnets, considered for electron energy measurements at the High Fields QED experimental area at ELI-NP. The first magnet is a 2 meter long permanent magnet, placed inside the Interaction Chamber (IC). The second magnet is a 1.5 meters long electromagnet, placed outside IC. The pulsed electron beam will be produced by the 10 PW pulsed Laser, ‘pump-beam’, focused into one meter long capillary low density plasma cell. A second 10 PW pulsed Laser, ‘probe-beam’, will interact with the relativistic electron bunch providing the strong electromagnetic field. The ES will measure the subtle changes in the electron energy spectrum as a result of the electron beam interaction with the probe-beam field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- η experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The calorimeter system of the new muon g -2 experiment at Fermilab

The electromagnetic calorimeter for the new muon ( g −2) experiment at Fermilab will consist of arrays of PbF 2 Čerenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here the requirements for this system, the achieved solution and the results obtained from a test beam using 2.0–4.5 GeV electrons with a 28-element prototype array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetospheric Constellation and Tomography Mission Concept

We describe the basic principles, instrumentation, and feasibility of a multi-satellite mission that combines in situ observations of plasma and electromagnetic fields with radio tomography imaging. We show that a 16-satellite radio tomography experiment can produce two-dimensional images of plasma density in the earth's magnetosphere at sufficient spatial (1/2 R(sub E)) and temporal (approximately 10s) resolution to address key problems of magnetospheric physics. The same mission can incorporate electron and ion analyzers, magnetometers, and electric field instruments on the same spacecraft. We suggest that the large-scale images are more valuable when combined with in situ observations, supporting an unambiguous interpretation of the in situ data and an investigation of the interdependence of small- and large-scale plasma processes.

Ergun, R. E.↗

The Application of Beowulf-Class Computing to Computational Electromagnetics

Current computational developments at the Jet Propulsion Laboratory (JPL) are motivated by the NASA/JPL goal of reducing payload in future space missions while increasing mission capability through miniaturization of active and passive sensors, analytical instruments and communication systems.

beowulf-class↗

Status of the MeLoDIE experiment, an advanced device for the study of the irradiation creep of LWR cladding with full online capabilities

As a prototype of future instrumented material experiments in the Jules Horowitz Reactor (JHR), the MELODIE project was launched in 2009 by the CEA in collaboration with VTT. Being designed as a biaxial creep experiment with online capability, MELODIE is able to apply an online-controlled biaxial loading on a LWR clad sample up to 120 MPa and to perform an online measurement of its biaxial deformation. An important experimental challenge was to perform reliably accurate measurements under the high nuclear heat load of in-core locations while keeping within their tight space. For that purpose, specific sensors were co-designed with and built by IFE Halden. Manufacturing of the MELODIE components was completed one year ago. The complexity of its in-pile section and of the pressurization system requested a step-by-step tuning of the setup. The toughest part of this process dealt with the Diameter gauge which required a partial redesign to take into account unexpected and unwanted electromagnetic interactions with the hosting device. Final cold performance tests of the on-board instrumentation will be presented. The MELODIE device is now ready and irradiation should start in OSIRIS reactor this spring. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optical properties and emissivities of liquid metals and alloys

This paper presents the results from our on-going program to investigate the optical properties of liquid metals and alloys at elevated temperatures. Ellipsometric and polarimetric techniques have been used to investigate the optical properties of materials in the 1000 - 3000 K temperature range and in the 0.3 - 0.1 mu m wavelength range. The ellipsometric and polarimetric techniques are described and the characteristics of the instruments are presented. The measurements are conducted by reflecting a polarized laser beam from an electromagnetically levitated liquid metal or alloy specimen. A Rotating Analyzer Ellipsometer (RAE) or a four-detector Division-of-Amplitude Photopolarimeter (DOAP) is used to determine the polarimetric properties of the light reflected at an angle of incidence of approximately 68 deg. Optical properties of the specimen which are calculated from these measurements include the index of refraction, extinction coefficient, normal spectral emissivity, and spectral hemispherical emissivity. These properties have been determined at various wavelengths and temperatures for liquid Ag, Al, Au, Cu, Nb, Ni, Pd, Pt, Si, Ti, Ti-Al alloys, U, and Zr. We also describe new experiments using pulsed-dye laser spectroscopic ellipsometry for studies of the wavelength dependence of the emissivities and optical properties of materials at high temperature. Preliminary results are given for liquid Al. The application of four-detector polarimetry for rapid determination of surface emissivity and true temperature is also described. Characteristics of these devices are presented. An example of the accuracy of this instrument in measurements of the melting point of zirconium is illustrated.

Krishnan, Shankar↗

DGFRS-2—A gas-filled recoil separator for the Dubna Super Heavy Element Factory

The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods to determine the radiated power in SPI-mitigated disruptions in JET

Here we present techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

47 OTHER INSTRUMENTATION↗

Monte Carlo N-Particle forward modeling for density reconstruction of double shell capsule radiographs

In the Double Shell Inertial Confinement Fusion concept, characterizing the shape asymmetry of imploding metal shells is vital for understanding energy-efficient compression and radiative losses of the thermonuclear fuel. The Monte Carlo N-Particle MCNP® code forward models radiography of Double Shell capsule implosions using the Advanced Radiographic Capability at the National Ignition Facility. A procedure is developed for using MCNP to reconstruct density profiles from the radiograph image intensity. For a given Double Shell imploding target geometry, MCNP radiographs predict image contrast, which can help guide experimental design. Finally, in future work, the calculated MCNP synthetic radiographs will be compared with experimental radiographs to determine the radial and azimuthal density profiles of the Double Shell capsules.

47 OTHER INSTRUMENTATION↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Radio frequency electrical resistance measurement under destructive pulsed magnetic fields

We developed a resistance measurement using radio frequency reflection to investigate the electrical transport characteristics under destructive pulsed magnetic fields above 100 T. A sample stage consisting of a homemade flexible printed circuit reduced the noise caused by the induced voltage from the pulsed magnetic fields, improving the accuracy of the measurements of the reflected waves. From the obtained reflectance data, the absolute value of the magnetoresistance was successfully determined by analyzing the phase with admittance charts. In conclusion, these developments enable more accurate and comprehensive measurements of electrical resistance in pulsed magnetic fields.

47 OTHER INSTRUMENTATION↗