Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

2D grating simulation for X-ray phase-contrast and dark-field imaging with a Talbot interferometer

Talbot interferometry is a recently developed and an extremely powerful X-ray phase-contrast imaging technique. Besides giving access to ultra-high sensitivity differential phase contrast images, it also provides the dark field image, which is a map of the scattering power of the sample. In this paper we investigate the potentialities of an improved version of the interferometer, in which two dimensional gratings are used instead of standard line grids. This approach allows to overcome the difficulties that might be encountered in the images produced by a one dimensional interferometer. Among these limitations there are the phase wrapping and quantitative phase retrieval problems and the directionality of the differential phase and dark-field signals. The feasibility of the 2D Talbot interferometer has been studied with a numerical simulation on the performances of its optical components under different circumstances. The gratings can be obtained either by an ad hoc fabrication of the 2D structures or by a superposition of two perpendicular linear grids. Through this simulation it has been possible to find the best parameters for a practical implementation of the 2D Talbot interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visible Light Diagnostics at SPEAR3

The visible light diagnostic beam line at SPEAR3 utilizes dipole radiation extracted through an ID exit port to evaluate electron beam properties at a variety of diagnostic end-stations. The unfocused SR light is collected 17 m from the source point by a 150 mm diameter, f = 2 m lens and optically relayed to the appropriate station. For transverse imaging, an image-intensified PiMax camera with 2 ns gate allows measurement of fast beam dynamics for either the stored beam or the injected beam. For these applications the visible light is switched into either a standard symmetric-lens transport line or a beam-shaping transport line equipped with cylindrical lenses and a rotating mirror to sweep the beam image across the camera photocathode. A separate two slit stellar-interferometer branch line can resolve the diffraction-limited vertical beam height down to about 10 {mu}m. For longitudinal charge profile measurements, the light is switched to a Hamamatsu C5680 streak camera with net system resolution of {approx}2.5 ps rms. In this paper we outline the main photon beam transport line, review the SR beam properties and describe measurement capabilities at each diagnostic station.

43 PARTICLE ACCELERATORS↗

Synchrotron Radiation Therapy from a Medical Physics point of view

Synchrotron radiation (SR) therapy is a promising alternative to treat brain tumors, whose management is limited due to the high morbidity of the surrounding healthy tissues. Several approaches are being explored by using SR at the European Synchrotron Radiation Facility (ESRF), where three techniques are under development Synchrotron Stereotactic Radiation Therapy (SSRT), Microbeam Radiation Therapy (MRT) and Minibeam Radiation Therapy (MBRT).The sucess of the preclinical studies on SSRT and MRT has paved the way to clinical trials currently in preparation at the ESRF. With this aim, different dosimetric aspects from both theoretical and experimental points of view have been assessed. In particular, the definition of safe irradiation protocols, the beam energy providing the best balance between tumor treatment and healthy tissue sparing in MRT and MBRT, the special dosimetric considerations for small field dosimetry, etc will be described. In addition, for the clinical trials, the definition of appropiate dosimetry protocols for patients according to the well established European Medical Physics recommendations will be discussed. Finally, the state of the art of the MBRT technical developments at the ESRF will be presented. In 2006 A. Dilmanian and collaborators proposed the use of thicker microbeams (0.36-0.68 mm). This new type of radiotherapy is the most recently implemented technique at the ESRF and it has been called MBRT. The main advantage of MBRT with respect to MRT is that it does not require high dose rates. Therefore it can be more easily applied and extended outside synchrotron sources in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Power Laser-Metal Interaction for Space Propulsion Applications

The micro-Newton thrust generation was observed through low-power continuous-wave laser and aluminum foil interaction without any remarkable ablation of the target surface. To evaluate the thrust characteristics, a torsion-balance thrust stand capable for the measurement of the thrust level down to micro-Newton ranges was developed. In the case of an aluminum foil target with 12.5 micrometer thickness, the maximum thrust level was 15 micro-Newtons when the laser power was 20 W. It was also found that the laser intensity, or laser power per unit area, irradiated on the target was significantly important on the control of the thrust even under the low-intensity level.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RPL Dosimetry: Principles and Applications

The principle of radio-photoluminescence (RPL) is applied to the glass dosimeter, which is one of the most excellent solid state dosimeters. The silver activated phosphate glass irradiated with ionizing radiations emits luminescence when exposed to UV light. This phenomenon is called RPL. The most characteristic features of the glass dosimeters are data accumulation and no fading. The basic principle of RPL is described and then how it is applied to the glass dosimeter is explained. Finally some applications of RPL will be introduced.

61 RADIATION PROTECTION AND DOSIMETRY↗

Non-destructive testing using two-component/two-wave mixing interferometer

A new laser-based ultrasonic (LBU) receiver was recently introduced. The novel architecture is based on two-wave mixing in photorefractive materials and allows simultaneous measurement of in-plane and out-of-plane displacements (two- component). By taking advantage of recent developments in electronic processing and our knowledge on multi-channel interferometer, we achieved a compact optical system using only a single collecting aperture and a single laser probe beam. We will characterize the system performances and present experimental results demonstrating the capability for this compact two-component interferometer.

42 ENGINEERING↗

EIT Based Gas Detector Design by Using Michelson Interferometer

Electromagnetically induced transparency (EIT) is one of the interesting phenomena of light-matter interaction which modifies matter properties for propagation of light. In other words, we can change the absorption and refractive index (RI) in neighborhood of the resonant frequency using EIT. In this paper, we have doped 3-level quantum dots in one of the Michelson Interferometer's mirror and used EIT to change its RI. So, a controllable phase difference between lights in two arms of interferometer is created. Long response time is the main drawback of Michelson interferometer based sensor, which is resolved by this technique.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. X. SPECTRAL ATLAS OF A COLD FEATURE OBSERVED WITH HINODE/EUV IMAGING SPECTROMETER

In this work, we report on a cold, bright portion of an active region observed by the Hinode/EUV Imaging Spectrometer. The emitting plasma was very bright at transition region temperatures, and the intensities of lines of ions formed between 10{sup 5} and 10{sup 6} K were enhanced over normal values. The data set constitutes an excellent laboratory where the emission of transition region ions can be tested. We first determine the thermal structure of the observed plasma, and then we use it (1) to develop a spectral atlas, and (2) to assess the quality of CHIANTI atomic data by comparing predicted emissivities with observed intensities. We identify several lines never observed before in solar spectra, and find an overall very good agreement between CHIANTI-predicted emissivities and observations.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECTROSCOPIC ANALYSIS OF AN EIT WAVE/DIMMING OBSERVED BY HINODE/EIS

EUV Imaging Telescope (EIT) waves are a wavelike phenomenon propagating outward from the coronal mass ejection source region, with expanding dimmings following behind. We present a spectroscopic study of an EIT wave/dimming event observed by the Hinode/Extreme-ultraviolet Imaging Spectrometer. Although the identification of the wave front is somewhat affected by the pre-existing loop structures, the expanding dimming is well defined. We investigate the line intensity, width, and Doppler velocity for four EUV lines. In addition to the significant blueshift implying plasma outflows in the dimming region as revealed in previous studies, we find that the widths of all four spectral lines increase at the outer edge of the dimmings. We illustrate that this feature can be well explained by the field line stretching model, which claims that EIT waves are apparently moving brightenings that are generated by the successive stretching of the closed field lines.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE NATURE OF THE COMPACT OBJECT IN SS 433: OBSERVATIONAL EVIDENCE OF X-RAY PHOTON INDEX SATURATION

We present an analysis of the X-ray spectral properties observed from the black hole candidate (BHC) binary SS 433. We have analyzed Rossi X-ray Timing Explorer data from this source, coordinated with Green Bank Interferometer/RATAN-600. We show that SS 433 undergoes an X-ray spectral transition from the low hard state to the intermediate state (IS). We show that the X-ray broadband energy spectra during all spectral states are well fitted by a sum of the so-called bulk motion Comptonization (BMC) component and by two (broad and narrow) Gaussians for the continuum and line emissions, respectively. In addition to these spectral model components, we also find a strong feature that we identify as a 'blackbody-like (BB)' component in which the color temperature is in the range of 4-5 keV in 24 IS spectra during the radio outburst decay in SS 433. Our observational results on the 'high-temperature BB' bump lead us to suggest the presence of gravitationally redshifted annihilation line emission in this source. In fact, this spectral feature has been recently reproduced in Monte Carlo simulations by Laurent and Titarchuk. We have also established the photon index saturation at about 2.3 in index versus mass accretion correlation. This index-mass accretion correlation allows us to evaluate the low limit of the black hole (BH) mass of the compact object in SS 433, M{sub bh{approx}}>2 solar masses, using the scaling method using BHC GX 339 - 4 as a reference source. Our estimate of the BH mass in SS 433 is consistent with the recent BH mass measurement using the radial velocity measurements of the binary system by Hillwig and Gies, who find that M{sub x} = (4.3 {+-} 0.8) solar masses. This is the smallest BH mass found up to now among all BH sources. Moreover, the index saturation effect versus mass accretion rate revealed in SS 433, as in a number of other BH candidates, is strong observational evidence for the presence of a BH in SS 433.

79 ASTRONOMY AND ASTROPHYSICS↗

Passive decoy-state quantum key distribution with practical light sources

Decoy states have been proven to be a very useful method for significantly enhancing the performance of quantum key distribution systems with practical light sources. Although active modulation of the intensity of the laser pulses is an effective way of preparing decoy states in principle, in practice passive preparation might be desirable in some scenarios. Typical passive schemes involve parametric down-conversion. More recently, it has been shown that phase-randomized weak coherent pulses (WCP) can also be used for the same purpose [M. Curty et al., Opt. Lett. 34, 3238 (2009).] This proposal requires only linear optics together with a simple threshold photon detector, which shows the practical feasibility of the method. Most importantly, the resulting secret key rate is comparable to the one delivered by an active decoy-state setup with an infinite number of decoy settings. In this article we extend these results, now showing specifically the analysis for other practical scenarios with different light sources and photodetectors. In particular, we consider sources emitting thermal states, phase-randomized WCP, and strong coherent light in combination with several types of photodetectors, like, for instance, threshold photon detectors, photon number resolving detectors, and classical photodetectors. Our analysis includes as well the effect that detection inefficiencies and noise in the form of dark counts shown by current threshold detectors might have on the final secret key rate. Moreover, we provide estimations on the effects that statistical fluctuations due to a finite data size can have in practical implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Illusion optics in chaotic light

The time-reversal process provides the possibility to counteract the time evolution of a physical system. Recent research has shown that such a process can occur in the first-order field correlation of chaotic light and result in the spatial interference and phase-reversal diffraction in an unbalanced interferometer. Here we report experimental investigations on the invisibility cloak and illusion phenomena in chaotic light. In an unbalanced interferometer illuminated by thermal light, we have observed the cloak effect and the optical transformation of one object into another object. The experimental results can be understood by the phase-reversal diffraction, and they demonstrate the theoretical proposal of similar effects in complementary media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetically induced transparency in paraffin-coated vapor cells

Antirelaxation coatings in atomic vapor cells allow ground-state coherent spin states to survive many collisions with the cell walls. This reduction in the ground-state decoherence rate gives rise to ultranarrow-bandwidth features in electromagnetically induced transparency (EIT) spectra, which can form the basis of, for example, long-time scale slow and stored light, sensitive magnetometers, and precise frequency standards. Here we study, both experimentally and theoretically, how Zeeman EIT contrast and width in paraffin-coated rubidium vapor cells are determined by cell and laser-beam geometry, laser intensity, and atomic density. Using a picture of Ramsey pulse sequences, where atoms alternately spend ''bright'' and ''dark'' time intervals inside and outside the laser beam, we explain the behavior of EIT features in coated cells, highlighting their unique characteristics and potential applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Forecast constraints on inflation from combined CMB and gravitational wave direct detection experiments

We study how direct detection of the inflationary gravitational wave background constrains inflationary parameters and complements CMB polarization measurements. The error ellipsoids calculated using the Fisher information matrix approach with Planck and the direct detection experiment, Big Bang Observer (BBO), show different directions of parameter degeneracy, and the degeneracy is broken when they are combined. For a slow-roll parametrization, we show that BBO could significantly improve the constraints on the tensor-to-scalar ratio compared with Planck alone. We also look at a quadratic and a natural inflation model. In both cases, if the temperature of reheating is also treated as a free parameter, then the addition of BBO can significantly improve the error bars. In the case of natural inflation, we find that the addition of BBO could even partially improve the error bars of a cosmic variance-limited CMB experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing parity-violating mechanisms with cosmic microwave background experiments

Chiral gravity and cosmological birefringence both provide physical mechanisms to produce parity-violating TB and EB correlations in the cosmic microwave background (CMB) temperature/polarization. Here, we study how well these two mechanisms can be distinguished if nonzero TB/EB correlations are found. To do so, we evaluate the correlation matrix, including new TB-EB covariances. We find that the effects of these two mechanisms on the CMB are highly orthogonal, and can thus be distinguished fairly well in the case of a high-signal-to-noise detection of TB/EB correlations. Appendix 2 evaluates the relative sensitivities of the BB, TB, and EB signals for detecting a chiral gravitational-wave background.

79 ASTRONOMY AND ASTROPHYSICS↗