At least 289 records · Page 16

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Ego Vehicle and System Level Benefits of Eco-Driving on Chassis Dynamometer

Eco-Driving with connected and automated vehicles has shown potential to reduce energy consumption of an individual (i.e., ego) vehicle by up to 15%. In a project funded by ARPA-E, a team led by Southwest Research Institute demonstrated an 8-12% reduction in energy consumption on a 2017 Prius Prime. This was demonstrated in simulation as well as chassis dynamometer testing. The authors presented a simulation study that demonstrated corridor-level energy consumption improvements by about 15%. This study was performed by modeling a six-kilometer-long urban corridor in Columbus, Ohio for traffic simulations. Five powertrain models consisting of two battery electric vehicles (BEVs), a hybrid electric vehicle (HEV), and two internal combustion engine (ICE) powered vehicles were developed. The design of experiment consisted of sweeps for various levels of traffic, penetration of smart vehicles, penetration of technology, and powertrain electrification. The large-scale simulation study consisted of doing approximately 96,000 powertrain simulations. A sophisticated clustering scheme was built and utilized to down select representative traces for each scenario from the simulation study for vehicle testing on a chassis dynamometer. Furthermore, this paper provides a summary of individual ego vehicle testing as well as a comprehensive overview of the method utilized for down selecting representative traces from large scale simulation studies that can be used to quantify corridor level benefits. Vehicle test results along with corresponding analyses are presented.

33 ADVANCED PROPULSION SYSTEMS↗

Efficient Air Dehumidification Can Save 15%-50% of Cooling Energy in Commercial Buildings

Current approach to dehumidification in commercial buildings with chilled/hot water AHU systems is to overcool return + supply air to dewpoint, and then reheat before supply to zone. This is energy inefficient, with reheat often being gas-fired. To reduce energy consumption, building operators will often operate at little-to-no outside air, sacrificing IAQ. Decarbonizing commercial buildings requires solutions to reduce and fully electrify dehumidification energy consumption. The Altaire ADAPT and Conservant HEDS systems aim to solve this problem by decoupling humidity control from cooling reduces energy consumption while enabling improved IAQ management.

commercial buildings↗

Dendrite-free Al recycling via electrodeposition using ionic liquid electrolytes: The effects of deposition temperature and cathode surface roughness

In this report, the electrodeposition of Al from aluminum scrap alloys (A2020) on copper cathode substrates with varied surface roughness under different deposition temperatures was studied using low-temperature AlCl 3 -1-butyl-3-methyl-imidazolium chloride (BMIC) ionic liquid electrolytes. The bulk electrodeposition of Al was carried out under a voltage of 1.5 V at a stirring rate of 120 rpm using a fixed ionic liquid electrolyte concentration (molar ratio AlCl 3 : BMIC = 2:1). The effects of deposition temperature (range from 80 °C to 140 °C) and surface roughness of Cu cathode substrates (polished by 320, 600, 800, 1200 grits SiC sandpapers and mirror polishing process) on the morphology of deposited Al, current density, current efficiency and energy consumption, were investigated. The Al deposits were characterized using scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), profilometer, and electrochemical measurements for current density, current efficiency, and energy consumption. It is demonstrated that the deposition temperature and surface roughness of Cu electrodes play a critical role in the nucleation and growth of Al deposits. Higher deposition temperature promotes the diffusion and/or migration of Al 2 Cl 7 - ions and then enhances the current density and efficiency during the electrodeposition of Al. Smoother surface of Cu electrodes is preferred for the formation of dendrite-free Al deposits. Typically, on the mirror polished Cu electrode, no Al dendrite structure was observed, and only plate-like Al deposits were formed at the deposition temperature of 100 °C. Pure metallic Al was successfully deposited on Cu electrodes in AlCl 3 + BMIC ionic liquid electrolytes for all experiments with a current efficiency range from 72% to 99% and energy consumption of 4.6–6.3 kW h/kg Al.

54 ENVIRONMENTAL SCIENCES↗

Multi-Model Future Typical Meteorological (fTMY) Weather Files for nearly every US County

Exploring climate-induced impacts on building energy consumption can provide valuable insights for sustainable energy planning and environmental management in the face of a changing climate. By utilizing future weather data statistically downscaled from the Intergovernmental Panel on Climate Change (IPCC) General Circulation Models (GCMs) from 2020-2100, this paper presents a broadening industry-consensus approach for generating future Typical Meteorological Year (fTMY) weather files through a combination of statistical downscaling and high-performance computing that generalizes across decades, multiple locations for a region, and varying climate models. Furthermore, these fTMY files have been generated for 3,128 US counties for capturing potential weather on a 20-year basis.

Building↗

Toward Enhancing Wastewater Treatment with Resource Recovery in Integrated Assessment and Computable General Equilibrium Models

Sustainable water management is essential to increasing water availability and decreasing water pollution. The wastewater sector is expanding globally and beginning to incorporate technologies that recover nutrients from wastewater. Nutrient recovery increases energy consumption but may reduce the demand for nutrients from virgin sources. We estimate the increase in annual global energy consumption (1,100 million GJ) and greenhouse gas emissions (84 million t CO2e) for wastewater treatment in the year 2030 compared to today’s levels to meet sustainable development goals. To capture these trends, integrated assessment and computable general equilibrium models that address the energy-water nexus must evolve. We reviewed 16 of these models to assess how well they capture wastewater treatment plant energy consumption and GHG emissions. Only three models include biogas production from the wastewater organic content. Four explicitly represent energy demand for wastewater treatment, and eight include explicit representation of wastewater treatment plant greenhouse gas emissions. Of those eight models, six models quantify methane emissions from treatment, five include representation of emissions of nitrous oxide, and two include representation of emissions of carbon dioxide. Our review concludes with proposals to improve these models to better capture the energy-water nexus associated with the evolving wastewater treatment sector.

42 ENGINEERING↗

Energy Prediction of the Chicago Metropolitan Area Using Distributed Transportation MBSE Framework

Energy consumption impact of vehicle powertrain is traditionally assessed using standard and regulatory drive cycles. In this paper, energy consumption is determined by studying all the trips occurring in the Chicago Metropolitan Area in a 24 hour period. The data is generated by combining Polaris, an agent based traffic flow model with SVTrip, a stochastic model that generates 1 Hz vehicle speed profiles and Autonomie, a detailed vehicle level modeling tool used to predict fuel consumption. Different scenarios are constructed to define trips for different timeframes and assumptions. Vehicle fleet distribution, vehicle technologies and automation levels are applied to represent an appropriate vehicle fleet for each scenario. Analysis of energy consumption is then discussed with a particular emphasis on the impact of powertrain technology and vehicle types.

Autonomie↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving energy performance metrics to maximize the benefits of disruptive technologies

Advances in appliance and equipment systems' technologies also cause changes in their technical characteristics that can affect energy consumption and associated greenhouse gas emissions. Energy performance evaluation methods that use testing and metrics can evolve to account for energy consumption contributed from new technological characteristics. However, there is no systematic effort to enable the advancement of test procedures and performance metrics to maximize the energy, climate, and financial benefits of disruptive technologies. Therefore, it is important for countries to regularly update their energy-efficiency policy programs, such as standards and labels, by improving test procedures and metrics to reflect the innovation in emerging technologies as well as to mitigate the risk of deploying obsolete technology. This paper shows how energy performance metrics have been improving in selected appliances and equipment and provides insights to design a systematic effort to improve metrics and test procedures at the speed of ongoing changes in technologies and markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary design data package, appendices C1 and C2

The HYBRID2 program which computes the fuel and energy consumption of a hybrid vehicle with a bi-modal control strategy over specified component driving cycles is described. Fuel and energy consumption are computed separately for the two modes of operation. The program also computes yearly average fuel and energy consumption using a composite driving cycle which varies as a function of daily travel. The modelling techniques are described, and subroutines and their functions are given. The composition of modern automobiles is discussed along with the energy required to manufacture an American automobile. The energy required to scrap and recycle automobiles is also discussed.

Source record↗

Demonstration of Intelligent HVAC Load Management With Deep Reinforcement Learning: Real-World Experience of Machine Learning in Demand Control

We report that buildings account for 40% of total primary energy consumption and 30% of all CO 2 emissions worldwide. A large portion of building energy consumption is due to heating, ventilation, and air-conditioning (HVAC) systems. In the summer, for example, more than 50% of a building’s electricity consumption is used for cooling. With proper energy management, buildings can provide load shifting, peak shaving, frequency regulation, and many other demand response services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Dataset 2024.1 Documentation

Public ResStock datasets provide credible, relevant, and accessible information on energy use and related non-energy metrics to a variety of stakeholders in the residential buildings space. The current public datasets include baseline building characteristics, timeseries (15-minute) energy consumption, and timeseries carbon emissions for the baseline (existing) U.S. housing stock and the U.S. housing stock with 10 "what-if" energy measure packages applied. This report documents a new public ResStock dataset to complement and build upon the existing public datasets. This dataset is specifically intended to be a resource for state and local decision-makers considering options for energy retrofits for their housing stock to reduce carbon emissions, energy use, and/or utility bills. These data consist of housing stock characteristics and modeled full-year energy consumption, carbon emission, energy bill, and energy burden data for the baseline U.S. housing stock as well as the U.S. housing stock with 260 "what-if" energy measure packages applied. These measure packages include measures related to the building envelope, appliances, pools and spas, lighting, water heating, and HVAC (including efficiency improvements and fuel switching with equipment at a range of performance levels) in a variety of combinations. This report provides methodology information on the generation of this dataset and serves as a key part of the dataset's public documentation.

buildings↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

Transportation vehicle energy intensities. A joint DOT/NASA reference paper

A compilation of data on the energy consumption of air and ground vehicles is presented. The ratio BTU/ASM, British Thermal Units/Available Seat Mile, is used to express vehicle energy intensiveness, and related to the energy consumed directly in producing seat-mile or ton-mile productivity. Data is presented on passenger and freight vehicles which are in current use or which are about to enter service, and advanced vehicles which may be operational in the 1980's and beyond. For the advanced vehicles, an estimate is given of the date of initial operational service, and the performance characteristics. Other key considerations in interpreting energy intensiveness for a given mode are discussed, such as: load factors, operations, overhead energy consumption, and energy investments in new structure and equipment.

Mascy, A. C.↗

Development of an Energy-Efficient and High-Productivity Ammonia Recovery and Removal Process Using Resin-Wafer Electrodeionization

As efforts to develop various energy resources, ammonia energy is emerging as a promising carbon-free fuel alternative. Recovering high-concentration ammonia and ammonium from wastewater potentially offers significant environmental and economic benefits. However, research on recovery technologies for industries such as semiconductors remains limited. This study develops an efficient, energy-saving ammonia recovery technology using Resin Wafer Electrodeionization (RW-EDI), specifically for the semiconductor industry. RW-EDI shows promise for recovering ammonia from high-concentration wastewater. By optimizing parameters, such as voltage and initial concentration, a balance between productivity and energy consumption is achieved. Results indicate that ammonium and fluoride ion transport kinetics are similar, with minimal competition and selectivity values between 0.95 and 1.08. As the initial ammonia/ammonium concentration increases from 500 to 8000 ppm, reaction rate constants and the overall mass transfer coefficient decrease. Increasing the voltage can enhance mass transfer and eliminate barriers. Ion transport primarily occurs in the RW solid phase, accounting for 93.89% of the total current. Additionally, RW-EDI shows superior specific energy consumption within a concentration range of 500 ppm to 8000 ppm, outperforming technologies like electrodialysis by reducing specific energy consumption from 8−15 kWh/kg-NH 4 + to 1.2−2.5 kWh/kg-NH 4 + . This study highlights RW-EDI’s potential for ammonia recovery, providing valuable insights for future applications in wastewater treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗