Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENVIRONMENTAL CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Exploration Extravehicular Mobility Unit (xEMU) Lunar Boot Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU lunar boots. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. This paper will address only the cold environment testing results. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through a heater cage surrounding the boots. Notably, the xEMU boots also contacted the liquid-nitrogen chilled floor inside of Chamber B, which provided a conduction pathway to simulate the thermal effects of the lunar surface. Test hardware was developed to extend the water tubing from the Liquid Cooling Ventilation Garment (LCVG) into the boots to set the internal thermal boundary nominally provided by the astronaut’s foot. Thirty-three temperature sensors were used to collect data in critical locations in the xEMU boot assembly as well as for calorimetry to determine heat flux to and from the boots. This paper will document the testing results and provide a high-level interpretation of the testing results. To conclude, this paper will address possible forward work and knowledge gaps present in lunar boot thermal performance and testing.

xEMU↗

Exploration Extravehicular Mobility Unit (xEMU) Hard Upper Torso (HUT) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU hard upper torso (HUT). Two HUTs, one composite HUT and one aluminum HUT, were tested simultaneously in Chamber B, with different thermal environments. For the aluminum HUT on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs. For the composite HUT on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. Seventy-two temperature sensors were used to collect data in critical locations in the xEMU HUT assembly. This paper will document the testing results and compare the test data against the xEMU HUT and system-level thermal models for model validation.

xEMU↗

Mars Exploration Rover thermal test program overview

In January 2004, two Mars Exploration Rovers (MER) landed on the surface of Mars to begin their mission as robotic geologists. A year prior to these historic landings, both rovers and the spacecraft that delivered them to Mars, were completing a series of environmental tests in facilities at the Jet Propulsion Laboratory. This paper describes the test program undertaken to validate the thermal design and verify the workmanship integrity of both rovers and the spacecraft. The spacecraft, which contained the rover within the aeroshell, were tested in a 7.5 m diameter thermal vacuum chamber. Thermal balance was performed for the near earth (hot case) condition and for the near Mars (cold case) condition. A solar simulator was used to provide the solar boundary condition on the solar array. IR lamps were used to simulate the solar heat load on the aeroshell for the off-sun attitudes experienced by the spacecraft during its cruise to Mars. Each rover was tested separately in a 3.0 m diameter thermal vacuum chamber over conditions simulating the warmest and coldest expected Mars diurnal temperature cycles. The environmental tests were conducted in a quiescent nitrogen atmosphere at a pressure of 8 to 10 Torr. In addition to thermal balance testing, the science instruments on board the rovers were tested successfully in the extreme environmental conditions anticipated for the mission. A solar simulator was not used in these tests.

thermal vacuum test↗

Nuclear Science Symposium, 21st, Scintillation and Semiconductor Counter Symposium, 14th, and Nuclear Power Systems Symposium, 6th, Washington, D.C., December 11-13, 1974, Proceedings

Papers are presented dealing with latest advances in the design of scintillation counters, semiconductor radiation detectors, gas and position sensitive radiation detectors, and the application of these detectors in biomedicine, satellite instrumentation, and environmental and reactor instrumentation. Some of the topics covered include entopistic scintillators, neutron spectrometry by diamond detector for nuclear radiation, the spherical drift chamber for X-ray imaging applications, CdTe detectors in radioimmunoassay analysis, CAMAC and NIM systems in the space program, a closed loop threshold calibrator for pulse height discriminators, an oriented graphite X-ray diffraction telescope, design of a continuous digital-output environmental radon monitor, and the optimization of nanosecond fission ion chambers for reactor physics. Individual items are announced in this issue.

Source record↗

Exploration Extravehicular Mobility Unit (xEMU) Helmet and Extravehicular Visor Assembly (EVVA) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU helmet and extravehicular visor assembly (EVVA). Two helmets/EVVAs were tested simultaneously in Chamber B, with different thermal environments and EVVA configurations. For the helmet/EVVA on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs, with four different visor and shade configurations. For the helmet/EVVA on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing, with a single visor and shade configuration. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. The thermal effects of the Exploration Informatics (xINFO) lights and camera on the helmet/EVVA was also tested. Twenty-two temperature sensors were used to collect data in critical locations in the xEMU helmet/EVVA assembly. This paper will document the testing results and compare the test data against the xEMU helmet/EVVA and system-level thermal models for model validation.

xEMU↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Test Article Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test results from the “Suit 2” Pressure Garment System (PGS) test article. The primary objective of the “Suit 2” PGS test article was to evaluate system-level suit heat leak and Environmental Protection Garment (EPG) thermal performance. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and a heater cage surrounding the test article. This paper will principally focus on system-level thermal results from the “Suit 2” PGS test article. This paper will examine data collected from one-hundred and seventy thermocouples located in critical locations inside and outside of the suit, as well as seven resistance thermometers (RTDs) for calorimetry to determine total heat flux in and out of the suit. The test data will be compared against the system-level PGS thermal models for model validation. To conclude, this paper will address knowledge gaps presented by unmanned xPGS thermal vacuum testing and the current state of lunar xPGS thermal modeling and testing.

xEMU↗

Update on Planetary, Lunar, & Asteroid Natural Environment Testbed (PLANET)

At ISMSE15, the Planetary, Lunar, & Asteroid Natural Environment Testbed (PLANET) was introduced as an upcoming high-fidelity, combined-effects planetary surface environment laboratory. This year, we will present an update on the facility status, describing the procurement, installation, commissioning of the chamber in Huntsville, Alabama (USA). With NASA’s push to return to the Moon through the Artemis program, there is a clear need for more high-fidelity test chambers that can replicate multiple aspects of the lunar surface, especially the fine, dusty lunar soil known as regolith. The PLANET chamber is designed to fill this gap, enabling research & development, qualification, and verification testing in a combined lunar surface environment, at an affordable price, for government, commercial/industry, and academic partners. Features include a large regolith simulant bed, low energy electron and ion sources to replicate the solar wind, full-spectrum UV and Solar simulation, and a liquid nitrogen cryogenic shroud, all in a high-vacuum environment (as low as 10^-7 mbar). PLANET’s initial focus will be on the lunar environment, but other surface environments (Martian, asteroid, etc.) are also possible to simulate. Besides the environmental instrumentation, PLANET will be equipped with specialized test systems that the Space Environmental Effects Team has developed over the past two years, including an in-situ tribometer and uniform dust distribution system. The chamber is currently being manufactured, with plans to install in May 2024. This will be followed by outfitting and commissioning. The challenges and accomplishments seen during this process will be detailed, and data from the first tests performed in PLANET will be shared with the community.

environmental testing↗

A study of the durability of beryllium rocket engines

An experimental test program was performed to demonstrate the durability of a beryllium INTEREGEN rocket engine when operating under conditions simulating the space shuttle reaction control system. A vibration simulator was exposed to the equivalent of 100 missions of X, Y, and Z axes random vibration to demonstrate the integrity of the recently developed injector-to-chamber braze joint. An off-limits engine was hot fired under extreme conditions of mixture ratio, chamber pressure, and orifice plugging. A durability engine was exposed to six environmental cycles interspersed with hot-fire tests without intermediate cleaning, service, or maintenance. Results from this program indicate the ability of the beryllium INTEREGEN engine concept to meet the operational requirements of the space shuttle reaction control system.

Paster, R. D.↗

Calibration of the active radiation detector for Spacelab-One

The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

Source record↗

The Multiple Use Plug Hybrid for NanoSats (MUPHyN) Miniature Thruster

The Multiple Use Plug Hybrid (for) Nanosats is a prototype thruster is being developed to fill a niche application for NanoSat-scale spacecraft propulsion. When fully developed, the MUPHyN thruster will provide an effective and low-risk propulsive capability that could enable multiple NanoSats to be independently re-positioned after deployment from a parent launch vehicle. Because the environmentally benign, chemically-stable propellants are mixed only within the combustion chamber after ignition and the flow rate of the fuel is determined by a pyrolysis mechanism that is nearly independent of pressure or fuel grain defects, the system is inherently safe and can be piggy-backed near a secondary payload with little or no overall mission risk increase to the primary payload. The MUPHyN thruster uses safe-handling and inexpensive nitrous oxide (N2O) and acrylonitrile-butadiene-styrene (ABS) as propellants. Fused Deposition Modeling (FDM), a direct digital manufacturing process, is used to fabricate short-form-factor solid fuel grains with multiple helical combustion ports from ABS thermoplastic. This manufacturing process allows for the rapid development and manufacture of complex fuel grain geometries that are not possible to extrude or cast using conventional methods. This technology enables the construction of fuel grains with length-to-diameter ratios appropriate for incorporation into CubeSats while maintaining high surface areas and regression rates that allow the system to maintain a near optimal oxidizer to fuel ratio. The MUPHyN system provides attitude control torques by using secondary-injection thrust vectoring on a truncated aerospike nozzle. This configuration allows large impulse delta V burns and small impulse attitude control firings to be performed with the same system. To ensure survivability during extend duration burns, the MUPHyN incorporates a novel regenerative cooling design where the N2O oxidizer flows through a cooling path embedded in the aerospike nozzle before being injected into the combustion chamber near the nozzle base.

Eilers, Shannon D.↗

CFD Analysis of Thermal Control System Using NX Thermal and Flow

The Thermal Control Subsystem (TCS) is a key part of the Advanced Plant Habitat (APH) for the International Space Station (ISS). The purpose of this subsystem is to provide thermal control, mainly cooling, to the other APH subsystems. One of these subsystems, the Environmental Control Subsystem (ECS), controls the temperature and humidity of the growth chamber (GC) air to optimize the growth of plants in the habitat. The TCS provides thermal control to the ECS with three cold plates, which use Thermoelectric Coolers (TECs) to heat or cool water as needed to control the air temperature in the ECS system. In order to optimize the TCS design, pressure drop and heat transfer analyses were needed. The analysis for this system was performed in Siemens NX Thermal/Flow software (Version 8.5). NX Thermal/Flow has the ability to perform 1D or 3D flow solutions. The 1D flow solver can be used to represent simple geometries, such as pipes and tubes. The 1D flow method also has the ability to simulate either fluid only or fluid and wall regions. The 3D flow solver is similar to other Computational Fluid Dynamic (CFD) software. TCS performance was analyzed using both the 1D and 3D solvers. Each method produced different results, which will be evaluated and discussed.

CFD↗

Ammonia Stability in a Simulated Trace Contaminant Rich Cabin Environment

The off-gassing of ammonia from hardware and metabolic sources presents a unique challenge to trace contaminant control system design, driving process flowrates to meet crewed air quality requirements. Accurately simulating representative trace contaminant cabin loads during ground testing is necessary to validate component design as well as understand potential contaminant propagation across life-support system process interface boundaries. This effort is complicated by the observed temporal concentration instability of gaseous ammonia in ground test chambers. To this end, ammonia concentration decay rates were characterized under controlled environmental conditions to better understand underlying phenomena and quantify incidental mass losses. The suspected chemical interaction between ammonia and trace acetaldehyde was investigated and its effect on species quantification was examined by both gas chromatography-mass spectrometry and Fourier-transform infrared spectroscopy. Recommendations for ground test procedures were made in order to best compensate for undesirable ammonia mass losses and mitigate test artifacts.

Kayatin, Matthew J.↗

Environmental noise experiment (DTO 71-22)

Only general conclusions can be reached of the effect of Skylab simulation chamber noise on the crewmen. Two crewmen experienced a small hearing decrement in-chamber, but there was no pattern as to the ear and frequency affected. Temporary hearing threshold shifts were observed in all three crewmen postchamber. These postchamber threshold shifts were perhaps the most significant finding of the study. However, no lasting detrimental effects on the crew's hearing were found.

Homick, J. L.↗

Monitoring the Air Quality in a closed Chamber Using an Electronic Nose

An Electronic Nose is being developed at JPL and Caltech for use in environmental monitoring in the International Space Station. The Electronic Nose (ENose) is an array of 32 polymer film conductometric sensors; the pattern of response may be deconvoluted to identify contaminants in the environment.

Air↗

Uniformity of environmental conditions and plant growth in a hydroponic culture system for use in a growth room with aerial CO2 control

A portable system of hydroponic culture was developed that maintained temperature, pH, and nutrient concentrations of circulating nutrient solutions. The hydroponic system is used within a controlled-environment room (CER) for control of aerial environment. The CER was equipped with an auto-calibrating system for atmospheric CO2 control. The control systems for the hydroponic chambers were able to maintain acidity within +/- 0.2 pH units and the temperature with +/- 0.5 degree C. Mixing time for the 200-liter volume of solution within a hydroponic chamber was less than 12 min. The CO2 control system was able to maintain aerial concentrations within +/- 10 ppm CO2 during the light period. The only gradient found to occur within the hydroponic chambers or CER was a slight gradient in aerial temperature along the length of hydroponic chambers. Growth of soybeans [Glycine max (L.) Merr.] was characterized during a 3-week period of vegetative development by leaf number and area, plant dry weight, total N content of plants, and N depletion from the nutrient solution. The growth characteristics among populations for three hydroponic chambers within the CER were not significantly different, and the percent standard errors of means of the measurements within populations from each chamber were nearly all less than 10%. Thus, the uniformity of plant growth reflected the uniformity of environmental conditions.

NASA Discipline Life Support Systems↗

Autoignition test cell Patent

Test chamber for determining decomposition and autoignition of materials used in spacecraft under controlled environmental conditions

Bryan, C. J.↗

Self-regulating heater application to Shuttle/Centaur hydrazine fuel line thermal control

The Shuttle/Centaur high energy upper stage vehicle thermal environments were more severe than previous Centaur vehicle thermal environments, creating need for a new hydrazine fuel line thermal control technique. Constant power heaters did not satisfy power dissipation requirements, because the power required to maintain fuel line thermal control during cold conditions exceeded the maximum power allowable during hot conditions. Therefore, a Raychem Thermolimit self-regulating heater was selected for this application, and was attached to the hydrazine fuel line with Kapton and aluminum foil tapes. Fuel line/heater thermal modeling and subsequent thermal vacuum chamber testing simulated heater thermal performance during all worst-case Shuttle/Centaur thermal environmental conditions. Fuel line temperatures were maintained between the 4C to 71C limits during all analytical and test cases. Finally, the thermal model predictions were correlated with the test data, thereby ensuring that the model would provide satisfactory predictions for future missions and/or vehicles.

Unkrich, David B.↗