Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Full-Column Greenhouse Gas Sampling Field Campaign Report

The AirCore is a balloon-borne sampler patented and developed at the National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) (Tans 2009) that has the capability to provide full-column measurements of greenhouse gases and other trace gas species (Karion et al. 2010). It consists of a long, coated stainless steel tube that is filled with a known trace gas mixture prior to balloon launch (Figure 1). The AirCore is opened at one end prior to balloon launch and, as the balloon ascends, it evacuates to ambient pressure. At 30 km, the balloon is cut away and the AirCore descends via parachute, now capturing an atmospheric air sample or “core” of air from 30 km to the surface due to the pressure gradient between the evacuated AirCore and the environment. Upon landing, the AirCore is closed, preserving the air sample collected in-flight. Because diffusion acts slowly on the AirCore sample in the four hours that it typically takes to launch, retrieve, and analyze the sample, it is possible to capture more than 100 discrete samples in the atmospheric profile collected by the AirCore. Currently, the AirCore is analyzed for carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO) at NOAA/ESRL GMD, but the sample collected can be measured on a variety of other analyzers to obtain full-column profiles of other trace gas species. Unlike routine aircraft measurements, the AirCore provides a low-cost alternative to atmospheric profiling and captures >95% of the atmospheric column. It has a variety of applications, including to full-column greenhouse and trace gas sampling and monitoring, to satellite and remote-sensing instrumentation evaluation, and to tropospheric and stratospheric model evaluation.

Greenhouse gases, Southern Great Plains, balloon-b↗

The Nuclear Accident at Three Mile Island a Practical Lesson in the Fundamental Importance of Effective Communications

The Three Mile Island Unit 2 (TMI-2) accident in March 1979 had a profound effect on the course of commercial nuclear generation in the United States and around the world. And while the central elements of the accident were matters of nuclear engineering, design and operations, its consequences were compounded, and in some respects superseded, by extraordinarily ineffective communications by all parties at all levels. Communications failures during the accident and its aftermath caused misunderstanding, distrust, and incorrect emergency response - and seeded or reinforced public opposition to nuclear power that persists to this day. There are communications lessons from TMI that have not yet been fully learned, and some that once were learned but are now gradually being forgotten. The more glaring TMI communications problems were in the arena of external interactions and communications among the plant owner, the Nuclear Regulatory Commission (NRC), the media, and the public. Confusing, fragmented, and contradictory public statements early in the accident, regardless of cause, undermined all possibility for reasonable discourse thereafter. And because the TMI accident was playing out on a world stage, the breakdown in public trust had long term and widespread implications. At the plant site, both TMI-2 cleanup and restart of the undamaged TMI-1 unit met with years of public and political criticism, and attendant regulatory pressure. Across the nation, public trust in nuclear power and those who operate it plummeted, unquestionably contributing to the 25+ year hiatus in new plant orders. There were other, less visible but equally important, consequences of ineffective communications at TMI. The unplanned 'precautionary' evacuation urged by the governor two days after the accident - a life changing, traumatic event for thousands of residents - was prompted primarily by misunderstandings and miscommunications regarding the condition of the plant. And today, nearly 30 years after the event, many in our nuclear industry have insufficient knowledge or regard for the underlying nuclear safety vulnerabilities revealed by the accident, in part because these have not been well explained. From this single, compelling experience, many lessons can be drawn. Some of these were recognized early and taken to heart by those who own and operate nuclear plants - but over time, respect for their importance has given way somewhat to the seemingly more urgent practicalities of plant cost, schedule and production goals. In other cases, the lessons have remained largely obscure. This paper will describe in greater detail the communications aspects of the TMI accident, lessons that can be drawn from them, and their implications on current and future nuclear facility operation. The paper reflects the author's personal, direct experience as part of the accident response team and subsequent cleanup operations at TMI. In summary: The Three Mile Accident was the most severe nuclear accident in U.S. history. It also is perhaps the most studied industrial accident of any kind in U.S. history. Exhaustive examinations of the public health consequences of the accident show convincingly that the effects of radioactivity releases, if any, were imperceptibly low. It is generally agreed, however, that there have been perceptible health consequences from the TMI-2 accident - those linked to stress. Stress to members of the public, particularly those living near the plant, was unquestionably high. And for some the combination of rumor, confusion, contradictory reports and uncertainty, all leading to an evacuation recommendation from the governor, took a toll. It could be argued that the ineffective internal and external communications during the course of the event were as influential to the outcome as the equipment and operational breakdowns that are now so well understood. And for that reason alone, this accident points out that communications capabilities - staffing, systems, facilities, training - can be as important to protection of the public, the plant and the environment as are the plant material and technical issues that receive constant attention. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental verification of hydrogen isotope separation by pressure swing adsorption

Focusing on synthetic zeolites that adsorb hydrogen isotopes at liquid N{sub 2} temperature with priority in the order of T{sub 2}, DT, D{sub 2}, HT, HD and H{sub 2}, we have been developing a pressure swing adsorption process system for hydrogen isotope separation. For this purpose, we carried out fundamental experiments of adsorption and desorption of a tracer D{sub 2} in bulk H{sub 2} with zeolite packed-bed columns. In this paper, the results are reported that D{sub 2} is enriched in the adsorbed phase at separation factors near 2.0, flowing through zeolite 5A and 13X packed-beds at 77.4 K. These are in agreement with values predicted from the multi-component equilibrium characteristics. In the gas samples recovered by evacuating the packed-beds, however, D{sub 2} was detected at a relative concentration of 1.20 or 1.32 to that in the feed gas. This lower range results from the isotopic mass effect in kinetic process. That suggests a highly D{sub 2}-enriched residual left during evacuation. This is verified with an unusually high enrichment factor of 6.68 or 9.21 for zeolite 5A or 13X measured in the residual sample desorbed from the packed-bed by heating up to room temperature. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Retrieval System for Calcined Waste for the Idaho Cleanup Project - 12104

This paper describes the conceptual approach to retrieve radioactive calcine waste, hereafter called calcine, from stainless steel storage bins contained within concrete vaults. The retrieval system will allow evacuation of the granular solids (calcine) from the storage bins through the use of stationary vacuum nozzles. The nozzles will use air jets for calcine fluidization and will be able to rotate and direct the fluidization or displacement of the calcine within the bin. Each bin will have a single retrieval system installed prior to operation to prevent worker exposure to the high radiation fields. The addition of an articulated camera arm will allow for operations monitoring and will be equipped with contingency tools to aid in calcine removal. Possible challenges (calcine bridging and rat-holing) associated with calcine retrieval and transport, including potential solutions for bin pressurization, calcine fluidization and waste confinement, are also addressed. The Calcine Disposition Project has the responsibility to retrieve, treat, and package HLW calcine. The calcine retrieval system has been designed to incorporate the functions and technical characteristics as established by the retrieval system functional analysis. By adequately implementing the highest ranking technical characteristics into the design of the retrieval system, the system will be able to satisfy the functional requirements. The retrieval system conceptual design provides the means for removing bulk calcine from the bins of the CSSF vaults. Top-down vacuum retrieval coupled with an articulating camera arm will allow for a robust, contained process capable of evacuating bulk calcine from bins and transporting it to the processing facility. The system is designed to fluidize, vacuum, transport and direct the calcine from its current location to the CSSF roof-top transport lines. An articulating camera arm, deployed through an adjacent access riser, will work in conjunction with the retrieval nozzle to aid in calcine fluidization, remote viewing, clumped calcine breaking and recovery from off-normal conditions. As the design of the retrieval system progresses from conceptual to preliminary, increasing attention will be directed toward detailed design and proof-of- concept testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accident-tolerant fuel: quantifying relative risks and timescales in severe accidents

For such severe accident scenarios, a key objective for alternative 'accident tolerant' fuels (or ATFs) is to increase the threshold temperature for possible accelerated hydrogen production and/or fuel damage and core degradation. By reducing hydrogen production, this change to more ATF should also give more time for restoring power and cooling, for mitigating actions like emergency equipment deployment, and consequently effect on- and off-site evacuation decisions. There is always a finite and non-zero probability of core damage due to the likelihood and chance of not restoring power and cooling. Using the Fukushima complete Station Black Out (SBO) and Loss-of-Cooling (LOC) scenario as a starting point, this paper establishes a simple limiting estimate for the potential changes in the timescales available for power and cooling recovery and for emergency evacuation decision-making made possible by using ATFs. The straightforward analysis also provides a basis for estimating the realistic probability of avoiding core damage for a range of assumed ATF failure properties or criteria, and the needed backup cooling requirements. The analysis includes the effects on the recovery probability caused by significant disruption and chaos. The results show that for this accident scenario, there is a relatively small benefit or increase in recovery probability due to only having higher ATF failure limits. The largest relative benefit arises from not only having ATF but also assuring longer cooling by extending the boil off or time before core uncover and damage onset, from somehow adding and/or injecting sufficient make up water, and/or rejecting decay heat, say for five or more days. Obviously, as an added benefit, some ATF concepts avoid or reduce hydrogen production, which improves containment integrity but does not significantly alter the core damage or failure probability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Why accredit ISO/CEI 17025 a nuclear waste management laboratory? - 15112

When there is no storage, nor repository, available on a site, the entity in charge of nuclear waste management should find outlets in order to evacuate outside the site. Each outlet has his rules and waste acceptance criteria (packaging rules, physical/chemical/radiological criteria for example). Before you are able to evacuate your waste, an acceptance's process (or contract review) takes place. This process scans the entire measures implemented by the site in order to satisfy outlet's criteria. When the acceptance is obtained, shipments could be organized, and the process gets into an observation's phase. During this phase, the outlet could choose to inspect a finished nuclear waste package or to audit regularly the waste management process. In this last case, the outlet re-scans the entire documents and implemented measures. This audit lasts from one to several days. A way to tackle/approach the audit is to acknowledge, by a trusted third party (i.e. independent from the outlet), all or part of waste management system, in order to base one's reputation on this organism and win outlet's trust. For this purpose, the entity could choose certification or accreditation. Certification (ISO 9001 as often as not) aims at evaluating a system for managing the quality of one product or service. Accreditation (ISO 17025, for example) provides formal recognition for technical skills within a quality management system (clauses 5 and 4 of the ISO 17025 standard). In 2006, the LDM laboratory is the first French laboratory accredited, in accordance with ISO 17025 standard, for the characterization by gamma spectrometry on 100 L- and 200 L- radioactive waste drums (accreditation No 1-1712 - scope available on www.cofrac.fr). This accreditation allows the lab: - to update the quality management system, - to compile the entire technical file of the gamma-ray assay (description, evaluation of the uncertainties, calibration, proficiency testing programs, measurement procedures,...), - to pass previous identified constraints on to producers and nuclear waste package production, - to maintain permanent quality improvement loop, - to lighten the programs of outlets audits, through the acknowledgement of the technical competence of the laboratory to evaluate by gamma spectrometry the activity contained in our nuclear waste drums. On the other hand, the lab is re-evaluated periodically to ensure its continued compliance with requirements: within a 12 month's interval for an internal audit, with a 18 month's period for COFRAC (French sole official national accreditation body). Since 2006, the lab is accredited. His accreditation renewed in 2010. A new entire renewal audit is planned in 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solutions for management of defective fuel assemblies - 15318

Defective fuel management is a major challenge for nuclear operators when the time comes for finding a long-term solution for their used (or spent) fuel assemblies. This question of defective fuel management can be raised in several cases: - For optimizing the remaining operating costs of shutdown reactors, the spent fuel pools must be emptied as soon as possible; a solution needs therefore to be found for evacuating all the spent fuel assemblies, defective fuel assemblies and in particular defective fuel rods included; - Some utilities are today facing a saturation of their reactor spent fuel pool; evacuating the defective fuel assemblies and extracted defective fuel rods allows optimizing the space in the pool. Whereas the solutions for managing intact used fuel assemblies are well-known, a specific technical solution must be implemented for managing the defective spent fuel assemblies as well. The purpose of this paper is to describe the existing solutions for the management of all types of defective fuel assemblies. Interim Dry Storage Solution Interim dry storage of defective spent fuel assemblies is being implemented for decades in the USA. Specific operations are performed for preparing the defective fuel assemblies for interim dry storage and they are then stored with intact used fuel assemblies in the dry storage cask. The advantage of such a solution is its short-term cost effectiveness. The paper presents the existing dry interim storage solutions for defective used fuel rods, the way they are implemented, the associated operational experience. Long-term Dry Storage Solution A long-term dry storage solution for defective fuel assemblies is being developed, compliant with direct disposal requirements. The solution is based on the encapsulation of each defective fuel rod into a fuel rod capsule and an associated specific dry storage licensing approach: this is the best available technology regarding long term storage safety requirements. The paper presents this unique capsule technology, the transport and storage casks that can be used for transportation of defective fuel rods to the storage facility, and the associated transport licensing approach currently used in Europe. Treatment Solution. The most definitive way to get rid of defective fuel assemblies is their treatment (or reprocessing) in a treatment plant. There is then no need to assess the behaviour of these specific used fuel assemblies as for an interim storage facility or a final repository. The advantage of such a solution is its sustainable approach. The paper presents the existing transport and treatment solutions, the way they are implemented, the associated operational experience. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

42 ENGINEERING↗

Fabrication and Testing of DOE Standard Canister Closure Leak Test Assembly – 24139

DOE manages over 300 types of spent nuclear fuel (SNF), many of which are located at the Idaho National Laboratory (INL) site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in onsite storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale road-ready dry storage program at the INL site. In support of establishing a large-scale road-ready dry storage program at the INL site, the Road-Ready Demonstration will first package Fort St. Vrain SNF currently in dry storage at INL into several DOE Standard Canisters (DOESCs). These DOESCs will in turn be loaded into another containment similar to commercial multi-purpose canisters. This multi-purpose canister will then be compatible with a transportation or storage system, such as a storage cask for interim storage or transportation package for offsite transport. These DOESCs will remain sealed over the course of their storage, transportation, and applicable disposal functions. The closure process for the DOESC will include fuel and basket loading, welding, inspection, leak testing, and, if needed, repair. As a follow-up to previous discussions on the design of the DOE Closure Leak Test Assembly (LTA), this report describes recent fabrication and testing efforts performed at INL. DOESCs are sealed by two sequential gas tungsten arc welds, both of which are performed by remotely operated and semiautomatic welding systems. The first weld is a circumferential pipe weld that completes the assembly of the canister body and lid assembly. The second and final closure weld attaches the vent plug to the vent socket via a butt joint. After the second weld is performed, the welds are helium leak tested using an evacuated envelope technique. The LTA was designed for both remote and manual operation. This report describes the fabrication and performance testing associated with the evacuated envelope technique. INL staff designed, fabricated, and tested the LTA at INL facilities. This testing included establishing technique and system sensitivities in accordance with ASME and American National Standards Institute N14.5 requirements. Forthcoming work will cover such areas as design optimization, process and personnel qualification, and implementation in Road-Ready Demonstration operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Linear electric field time-of-flight ion mass spectrometer

A linear electric field ion mass spectrometer having an evacuated enclosure with means for generating a linear electric field located in the evacuated enclosure and means for injecting a sample material into the linear electric field. A source of pulsed ionizing radiation injects ionizing radiation into the linear electric field to ionize atoms or molecules of the sample material, and timing means determine the time elapsed between ionization of atoms or molecules and arrival of an ion out of the ionized atoms or molecules at a predetermined position.

47 OTHER INSTRUMENTATION↗

The Effectiveness of Reverse Telephon Emergency Warning Systems in the October 2007 San Diego Wildfires

Late in October, 2007, fast-moving wildfires fueled by extreme Santa Ana winds threatened residents and their properties in San Diego County, California. The impacted area also included the City of San Diego within the County s boundaries. It turns out the San Diego firestorms would be the biggest in the County's history, surpassing the devastating 2003 firestorms in intensity, duration, and impacted populations. Both San Diego County and the City of San Diego have installed telephone reverse call-down emergency warning systems. A telephone survey of 1200 households located in areas identified by emergency officials as the evacuation zones for the 2007 fires was conducted in late March and early April 2008 using a random telephone dialing process to determine if people responded to the reverse telephone warning systems calls. Findings indicate that those who received a reverse emergency warning call were much more likely to evacuate than those who did not receive a call. The telephone calls were also the most likely source of first warning.

99 GENERAL AND MISCELLANEOUS↗

Challenges of deflecting an asteroid or cometary nucleus with a nuclear burst

There are many natural disasters that humanity has to deal with over time. These include earthquakes, tsunami, hurricanes, floods, asteroid strikes, and so on. Many of these disasters occur slowly enough that some advance warning of which areas will be affected is possible. However, in almost all cases, the response is to evacuate the area to be affected and deal with the damage later. The evacuations for hurricanes Katrina and Rita on the US Gulf Coast in 2005 demonstrated the chaos that can result. In contrast with other natural disasters. it is likely that an asteroid or cometary nucleus on a collision course with Earth is likely to be detected with enough warning time to possibly deflect it away from the collision course. Thanks to near-Earth object (NEO) surveys, people are working towards a goal of cataloging at least 90% of all near-Earth objects with diameters larger than {approx}140 meters in the next decade. The question is how to mitigate the threat from an asteroid or cometary nucleus found to be on a collision course. We briefly review some possible methods, describing their good and bad points, and then embark on a more detailed description of using a nuclear munition in standoff mode to deflect an asteroid or cometary nucleus before it can hit Earth.

99 GENERAL AND MISCELLANEOUS↗

Multi-Criteria Sensor Placement for Emergency Response

This paper describes an approach to locating a set of sensors to provide early warning of a dangerous chemical or biological agent release. The objective of the warning system is to minimize potential fatalities and any other health-related problems resulting from either an accidental release (such as a chemical spill) or from of a deliberate act of terrorism. The sensor placement solution is described as part of a broader simulation approach that considers the number of sensors available for deployment, the effect of weather conditions on the spread and concentration of the agent released, the speed at which appropriate emergency response actions can be taken to evacuate or shelter-in-place, and factors that make some release points more likely than others, such as the relative ease of site access or the presence of high priority or high impact targets within the at-risk area. Aerial photography and GIS also play important roles in the decision support environment described.

54 ENVIRONMENTAL SCIENCES↗

Transient analysis and energy optimization of solar heating and cooling systems in various configurations

In this paper, a transient simulation model of solar-assisted heating and cooling systems (SHC) is presented. A detailed case study is also discussed, in which three different configurations are considered. In all cases, the SHC system is based on the coupling of evacuated solar collectors with a single-stage LiBr-H{sub 2}O absorption chiller, and a gas-fired boiler is also included for auxiliary heating, only during the winter season. In the first configuration, the cooling capacity of the absorption chiller and the solar collector area are designed on the basis of the maximum cooling load, and an electric chiller is used as the auxiliary cooling system. The second layout is similar to the first one, but, in this case, the absorption chiller and the solar collector area are sized in order to balance only a fraction of the maximum cooling load. Finally, in the third configuration, there is no electric chiller, and the auxiliary gas-fired boiler is also used in summer to feed the absorption chiller, in case of scarce solar irradiation. The simulation model was developed using the TRNSYS software, and included the analysis of the dynamic behaviour of the building in which the SHC systems were supposed to be installed. The building was simulated using a single-lumped capacitance model. An economic model was also developed, in order to assess the operating and capital costs of the systems under analysis. Furthermore, a mixed heuristic-deterministic optimization algorithm was implemented, in order to determine the set of the synthesis/design variables that maximize the energy efficiency of each configuration under analysis. The results of the case study were analyzed on monthly and weekly basis, paying special attention to the energy and monetary flows of the standard and optimized configurations. The results are encouraging as for the potential of energy saving. On the contrary, the SHC systems appear still far from the economic profitability: however, this is notoriously true for the great majority of renewable energy systems. (author)

14 SOLAR ENERGY↗

Graybox and adaptative dynamic neural network identification models to infer the steady state efficiency of solar thermal collectors starting from the transient condition

This paper deals with the development of methods for non steady state test of solar thermal collectors. Our goal is to infer performances in steady-state conditions in terms of the efficiency curve when measures in transient conditions are the only ones available. We take into consideration the method of identification of a system in dynamic conditions by applying a Graybox Identification Model and a Dynamic Adaptative Linear Neural Network (ALNN) model. The study targets the solar collector with evacuated pipes, such as Dewar pipes. The mathematical description that supervises the functioning of the solar collector in transient conditions is developed using the equation of the energy balance, with the aim of determining the order and architecture of the two models. The input and output vectors of the two models are constructed, considering the measures of 4 days of solar radiation, flow mass, environment and heat-transfer fluid temperature in the inlet and outlet from the thermal solar collector. The efficiency curves derived from the two models are detected in correspondence to the test and validation points. The two synthetic simulated efficiency curves are compared with the actual efficiency curve certified by the Swiss Institute Solartechnik Puffung Forschung which tested the solar collector performance in steady-state conditions according to the UNI-EN 12975 standard. An acquisition set of measurements of only 4 days in the transient condition was enough to trace through a Graybox State Space Model the efficiency curve of the tested solar thermal collector, with a relative error of synthetic values with respect to efficiency certified by SPF, lower than 0.5%, while with the ALNN model the error is lower than 2.2% with respect to certified one. (author)

14 SOLAR ENERGY↗

Optimization of a solar powered absorption cycle under Abu Dhabi's weather conditions

In order for the solar absorption air conditioners to become a real alternative to the conventional vapour compression systems, their performance has to be improved and their total cost has to be reduced. A solar powered absorption cycle is modeled using the Transient System Simulation (TRNSYS) program and Typical Meteorological Year 2 data of Abu Dhabi. It uses evacuated tube collectors to drive a 10 kW ammonia-water absorption chiller. Firstly, the system performance and its total cost are optimized separately using single objective optimization algorithms. The design variables considered are: the collector slope, the collector mass flow rate, the collector area and the storage tank volume. The single objective optimization results show that MATLAB global optimization methods agree with the TRNSYS optimizer. Secondly, MATLAB is used to solve a multi-objective optimization problem to improve the system's performance and cost, simultaneously. The optimum designs are presented using Pareto curve and show the potential improvements of the baseline system. (author)

14 SOLAR ENERGY↗

Earthquakes clustering based on the magnitude and the depths in Molluca Province

In this paper, we present a model to classify the earthquakes occurred in Molluca Province. We use K-Means clustering method to classify the earthquake based on the magnitude and the depth of the earthquake. The result can be used for disaster mitigation and for designing evacuation route in Molluca Province.

58 GEOSCIENCES↗