Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Investigation of Methane Generation Rates from Simulated and Radioactive Waste at Evaporator Conditions

Savannah River National Laboratory researchers have performed 9 experiments with simulated waste and 13 experiments with radioactive waste to determine methane generation rates (MGR) applicable to Savannah River Site waste at temperatures greater than or equal to 100 °C. Data from these experiments was used to generate temperature-dependent expressions to conservatively account for methane generation at elevated temperatures. Measured MGRs and the derived expressions are reported in units of standard cubic feet per hour per gallon of solution, where standard conditions are 25 °C and 1 atm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An augmented Young-Laplace model of an evaporating meniscus in a micro-channel with high heat flux

High flux evaporations from a steady meniscus formed in a 2 micron channel is modeled using the augmented Young-Laplace equation. The heat flux is found to be a function of the long range van der Waals dispersion force which represents interfacial conditions between heptane and various substrates. Heat fluxes of (1.3-1.6) x 10(exp 6) W/m(exp 2) based on the width of the channel are obtained for heptane completely wetting the substrate at 100 C. Small channels are used to obtain these large fluxes. Even though the real contact angle is 0 deg, the apparent contact angle is found to vary between 24.8 deg and 25.6 deg. The apparent contact angle, which represents viscous losses near the contact line, has a large effect on the heat flow rate because of its effect on capillary suction and the area of the meniscus. The interfacial heat flux is modeled using kinetic theory for the evaporation rate. The superheated state depends on the temperature and the pressure of the liquid phase. The liquid pressure differs from the pressure of the vapor phase due to capillarity and long range van der Waals dispersion forces which are relevant in the ultra think film formed at the leading edge of the meniscus. Important pressure gradients in the thin film cause a substantial apparent contact angle for a complete wetting system. The temperature of the liquid is related to the evaporation rate and to the substrate temperature through the steady heat conduction equation. Conduction in the liquid phase is calculated using finite element analysis except in the vicinity of the thin film. A lubrication theory solution for the thin film is combined with the finite element analysis by the method of matched asymptotic expansions.

Wayner, P. C., Jr.↗

LSPRAY: Lagrangian Spray Solver for Applications With Parallel Computing and Unstructured Gas-Phase Flow Solvers

Sprays occur in a wide variety of industrial and power applications and in the processing of materials. A liquid spray is a phase flow with a gas as the continuous phase and a liquid as the dispersed phase (in the form of droplets or ligaments). Interactions between the two phases, which are coupled through exchanges of mass, momentum, and energy, can occur in different ways at different times and locations involving various thermal, mass, and fluid dynamic factors. An understanding of the flow, combustion, and thermal properties of a rapidly vaporizing spray requires careful modeling of the rate-controlling processes associated with the spray's turbulent transport, mixing, chemical kinetics, evaporation, and spreading rates, as well as other phenomena. In an attempt to advance the state-of-the-art in multidimensional numerical methods, we at the NASA Lewis Research Center extended our previous work on sprays to unstructured grids and parallel computing. LSPRAY, which was developed by M.S. Raju of Nyma, Inc., is designed to be massively parallel and could easily be coupled with any existing gas-phase flow and/or Monte Carlo probability density function (PDF) solver. The LSPRAY solver accommodates the use of an unstructured mesh with mixed triangular, quadrilateral, and/or tetrahedral elements in the gas-phase solvers. It is used specifically for fuel sprays within gas turbine combustors, but it has many other uses. The spray model used in LSPRAY provided favorable results when applied to stratified-charge rotary combustion (Wankel) engines and several other confined and unconfined spray flames. The source code will be available with the National Combustion Code (NCC) as a complete package.

Raju, Manthena S.↗

A model of the evaporation of binary-fuel clusters of drops

A formulation has been developed to describe the evaporation of dense or dilute clusters of binary-fuel drops. The binary fuel is assumed to be made of a solute and a solvent whose volatility is much lower than that of the solute. Convective flow effects, inducing a circulatory motion inside the drops, are taken into account, as well as turbulence external to the cluster volume. Results obtained with this model show that, similar to the conclusions for single isolated drops, the evaporation of the volatile is controlled by liquid mass diffusion when the cluster is dilute. In contrast, when the cluster is dense, the evaporation of the volatile is controlled by surface layer stripping, that is, by the regression rate of the drop, which is in fact controlled by the evaporation rate of the solvent. These conclusions are in agreement with existing experimental observations. Parametric studies show that these conclusions remain valid with changes in ambient temperature, initial slip velocity between drops and gas, initial drop size, initial cluster size, initial liquid mass fraction of the solute, and various combinations of solvent and solute. The implications of these results for computationally intensive combustor calculations are discussed.

Harstad, K.↗

Anomalous FIM images of tungsten.

Observation of unusual field-ion images consisting of bright bands of variable width parallel to the 111 (in carets) zones in tungsten at 78 K. Typical conditions for the effect are: pulse width from 1 to 50 microsec and pulse height adjusted so that five to ten pulses are required to remove one (110) plane. The influence of a number of accessible variables was studied and the results lead to a two-mechanism model for field evaporation involving (1) a slow process requiring helium promotion and (2) unpromoted evaporation when the local helium supply is depleted at high rates. The model implies that helium diffusion is rate-limiting in the promotion mechanism and leads to a migration energy of about 0.15 eV during field evaporation. There is a measurable difference in end form in the limits of high- and low-field evaporation rates. High rates are nearly isotropic and yield a more hemispherical end form.

Hren, J. J.↗

Kinetic approach to the evaporation and condensation problem

In the paper, the Boltzmann equation governing the evaporation and condensation phenomena is solved by the Monte Carlo method. Based on the kinetic theory of gas the role of the non-equilibrium Knudsen layer and the growth of the hydrodynamic region outside the layer as time proceeds are simulated. Results show two possible types of transient developments in the vapor phase. The effects of the molecular absorption coefficient of the phase surface are examined. Except in the case of very strong evaporation the kinematic effects of binary collisions among vapor molecules on the mass flux rate are not serious. The limiting case of the quasi-steady evaporation and the maximal value of the evaporation rate are obtained.

Murakami, M.↗

Thermal and Hydrologic Signatures of Soil Controls on Evaporation: A Combined Energy and Water Balance Approach with Implications for Remote Sensing of Evaporation

The overall goal of this research is to examine the feasibility of applying a newly developed diagnostic model of soil water evaporation to large land areas using remotely sensed input parameters. The model estimates the rate of soil evaporation during periods when it is limited by the net transport resulting from competing effects of capillary rise and drainage. The critical soil hydraulic properties are implicitly estimated via the intensity and duration of the first stage (energy limited) evaporation, removing a major obstacle in the remote estimation of evaporation over large areas. This duration, or "time to drying" (t(sub d)), is revealed through three signatures detectable in time series of remote sensing variables. The first is a break in soil albedo that occurs as a small vapor transmission zone develops near the surface. The second is a break in either surface to air temperature differences or in the diurnal surface temperature range, both of which indicate increased sensible heat flux (and/or storage) required to balance the decrease in latent heat flux. The third is a break in the temporal pattern of near surface soil moisture. Soil moisture tends to decrease rapidly during stage 1 drying (as water is removed from storage), and then become more or less constant during soil limited, or "stage 2" drying (as water is merely transmitted from deeper soil storage). The research tasks address: (1) improvements in model structure, including extensions to transpiration and aggregation over spatially variable soil and topographic landscape attributes; and (2) applications of the model using remotely sensed input parameters.

Salvucci, Guido D.↗

Thermal and Hydrologic Signatures of Soil Controls on Evaporation: A Combined Energy and Water Balance Approach with Implications for Remote Sensing of Evaporation

The overall goal of this research is to examine the feasibility of applying a newly developed diagnostic model of soil water evaporation to large land areas using remotely sensed input parameters. The model estimates the rate of soil evaporation during periods when it is limited by the net transport resulting from competing effects of capillary rise and drainage. The critical soil hydraulic properties are implicitly estimated via the intensity and duration of the first stage (energy limited) evaporation, removing a major obstacle in the remote estimation of evaporation over large areas. This duration, or 'time to drying' (t(sub d)) is revealed through three signatures detectable in time series of remote sensing variables. The first is a break in soil albedo that occurs as a small vapor transmission zone develops near the surface. The second is a break in either surface to air temperature differences or in the diurnal surface temperature range, both of which indicate increased sensible heat flux (and/or storage) required to balance the decrease in latent heat flux. The third is a break in the temporal pattern of near surface soil moisture. Soil moisture tends to decrease rapidly during stage I drying (as water is removed from storage), and then become more or less constant during soil limited, or 'stage II' drying (as water is merely transmitted from deeper soil storage). The research tasks address: (1) improvements in model structure, including extensions to transpiration and aggregation over spatially variable soil and topographic landscape attributes; and (2) applications of the model using remotely sensed input parameters.

Salvucci, Guido D.↗

A two-phase three-field modeling framework for heat pipe application in nuclear reactors

Heat pipes and two-phase thermosyphons are highly efficient heat transfer devices utilizing continuous evaporation and condensation of working fluid for two-phase heat transport in closed systems. Because of the nearly isothermal and fully passive phase-change heat transfer mechanism, heat pipes and thermosyphons have found many applications in nuclear engineering, space technologies, and other energy systems. High-temperature heat pipes are used in nuclear microreactors to remove fission power from the primary system and are coupled with power conversion systems or process heat applications. Modeling of the two-phase flow phenomena inside a heat pipe is essential to its design and safety analysis. In this study, a comprehensive one-dimensional two-phase three-field flow model has been developed for the analysis of heat pipes in normal operation conditions and transients. The conservation or field equations of mass, momentum, and energy were developed for the liquid film, vapor, and droplet. In addition, constitutive models or correlations were reviewed thoroughly and provided for the closure of the three-field equations. Specific constitutive equations regarding interfacial mass and heat transfer at two interfaces, namely film-gas interface and gas-droplet interface, were reviewed for droplet entrainment and deposition rates as well as film and droplet evaporation rates. Furthermore, mechanistic correlations of annular flow film thickness were recommended for the modeling of the thermosyphons without a wick as a critical constitutive correlation. Furthermore, experimental data needs from new experiments using a prototype working fluid or surrogate fluids for the model validation of high-temperature heat pipes in microreactors were recommended for future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Transient Gas Phase Column Density Due to Droplet Evaporation

A NASA robotic refueling mission experiment on board the International Space Station (ISS) was designed to repeatedly transfer simulated cryogenic propellant between two dewars. After each metered transfer, the cryogen was to be vented overboard via sublimation or evaporation. ISS payload providers must conduct analyses to demonstrate that any planned gaseous venting generate no more than a certain level of material that may interfere with optical measurements from other payloads that may be located nearby. This requirement is expressed in terms of a maximum column number density (CND). For the experiment under consideration, fluid droplets likely would accompany any such vapor. Earlier related studies led to development of analytical expressions for column density along general paths for a number of practical cases under steady conditions, including droplet evaporation. These expressions are not appropriate for rapid evaporation of small droplets however, since the droplets cannot sustain mass flow rates consistent with steady conditions. In this work, analytical expressions are developed for estimating column density near a rapidly evaporating droplet along general paths. The influence for instantaneous evaporation is created first as a limiting case, where it is found the peak value occurs at the time it takes a wave of vapor to reach the closest point along the optical path traveling at its most probable thermal speed. Next, the case for finite-period evaporation is evaluated for constant conditions. Compared to the instantaneous case, peak column density occurs shortly after droplet extinction, but at a lower intensity. A new mathematical function is discovered that solves the integrals associated with this case. Finally, ways to account for droplet motion and changes in evaporation rate with size and temperature are discussed in this framework.

Woronowicz, M. S.↗

Sheet Membrane Spacesuit Water Membrane Evaporator

A document describes a sheet membrane spacesuit water membrane evaporator (SWME), which allows for the use of one common water tank that can supply cooling water to the astronaut and to the evaporator. Test data showed that heat rejection performance dropped only 6 percent after being subjected to highly contaminated water. It also exhibited robustness with respect to freezing and Martian atmospheric simulation testing. Water was allowed to freeze in the water channels during testing that simulated a water loop failure and vapor backpressure valve failure. Upon closing the backpressure valve and energizing the pump, the ice eventually thawed and water began to flow with no apparent damage to the sheet membrane. The membrane evaporator also serves to de-gas the water loop from entrained gases, thereby eliminating the need for special degassing equipment such as is needed by the current spacesuit system. As water flows through the three annular water channels, water evaporates with the vapor flowing across the hydrophobic, porous sheet membrane to the vacuum side of the membrane. The rate at which water evaporates, and therefore, the rate at which the flowing water is cooled, is a function of the difference between the water saturation pressure on the water side of the membrane, and the pressure on the vacuum side of the membrane. The primary theory is that the hydrophobic sheet membrane retains water, but permits vapor pass-through when the vapor side pressure is less than the water saturation pressure. This results in evaporative cooling of the remaining water.

Bue, Grant↗

Parameterizations of Entrainment-Mixing Mechanisms and their Effects on Cloud Droplet Spectral Width Based on Numerical Simulations

Entrainment-mixing mechanisms significantly affect cloud droplet number concentration, radius, and spectral shape. Quantitative examination of entrainment-mixing effects on cloud droplet spectral width is lacking. Here, we examine the effects of entrainment-mixing processes on cloud microphysics by 12,218 different setups, each simulated 10 times using the Explicit Mixing Parcel Model (EMPM) driven by the observational data from the Third Tibetan Plateau Atmospheric Scientific Experiment (TIPEX-III) campaign. Parameterizations of entrainment-mixing mechanisms are developed by relating homogeneous mixing degree to transition scale number that depends on the dissipation rate and droplet evaporation time scale. The correlation between relative dispersion of cloud droplet size distribution and homogeneous mixing degree changes from negative to positive with the decreasing homogeneous mixing degree. The different relationships are closely related to the competition between complete and partial droplet evaporation and the number concentration of small droplets, which are quantitatively described by two newly introduced dimensionless numbers. The competition is significantly affected by relative humidity and mixing fraction of entrained air as well as turbulence dissipation rate, but not much by cloud droplet number concentration. Especially, when relative humidity and dissipation rate are high, there is only a negative correlation. This study sheds new light on generalizing the homogeneous/inhomogeneous concept by considering relative dispersion, and also provides parameterizations of entrainment-mixing processes and relative dispersion for atmospheric models.

54 ENVIRONMENTAL SCIENCES↗

Four-man rated dual catalyst system for the recovery of water from urine

The catalytic system was integrated with a 4-man rated urine wick evaporator. During operation, urine vapor produced by the wick-evaporator was treated in the catalytic system to remove ammonia and volatile hydrocarbons, and water was recovered by condensation in a water cooled condenser. The system operated completely automatically and required no manual adjustments, except periodic supply of urine and removal of the recovered water. Although the system was designed for treating 0.325 kg urine per hour, this rate could be achieved only with a fresh wick, then gradually decreased as the wick became saturated with urine solids. The average urine treatment rates achieved during each of the three endurance tests were 0.137, 0.217, and 0.235 kg/hr. The quality of the recovered water meets drinking water standards, with the exception of a generally low pH.

Budininkas, P.↗

Thermal chains and entrainment in cumulus updrafts, Part 2: Analysis of idealized simulations

Research has suggested that the structure of deep convection often consists of a series of rising thermals, or “thermal chain”, which contrasts with existing conceptual models that are used to construct cumulus parameterizations. In this work, simplified theoretical expressions for updraft properties obtained in Part 1 of this study are used to develop a hypothesis explaining why this structure occurs. In this hypothesis, cumulus updraft structure is strongly influenced by organized entrainment below the updraft’s vertical velocity maximum. In a dry environment, this enhanced entrainment can locally reduce condensation rates and increase evaporation, thus eroding buoyancy. For moderate-to-large initial cloud radius R, this breaks up the updraft into a succession of discrete pulses of rising motion (i.e., a thermal chain). For small R, this leads to the structure of a single, isolated rising thermal. In contrast, moist environments are hypothesized to favor plume-like updrafts for moderate-to-large R. In a series of axisymmetric numerical cloud simulations, R and environmental relative humidity (RH) are systematically varied to test this hypothesis. Vertical profiles of fractional entrainment rate, passive tracer concentration, buoyancy, and vertical velocity from these runs agree well with vertical profiles calculated from the theoretical expressions in Part 1. Analysis of the simulations supports the hypothesized dependency of updraft structure on R and RH, that is, whether it consists of an isolated thermal, a thermal chain, or a plume, and the role of organized entrainment in driving this dependency. Additional 3-dimensional (3-D) turbulent cloud simulations are analyzed, and the behavior of these 3-D runs is qualitatively consistent with the theoretical expressions and axisymmetric simulations.

54 ENVIRONMENTAL SCIENCES↗

Volatility of sodium, potassium, and cesium perrhenates determined by thermogravimetry

Here, in this study, we investigated the volatility of sodium, potassium, and cesium perrhenates using thermogravimetry (TG) performed on single salts and their binary mixed salts. We performed simultaneous TG and differential scanning calorimetry under a ramp heating condition at 10°C/min up to 1200°C to characterize volatilization behavior as a function of temperature. We also performed isothermal TG over a temperature range of 700 to 975°C to estimate the vapor pressures of the alkali perrhenates based on a modified Langmuir equation that relates the rate of free evaporation from the open surface to vapor pressure. In this paper, we discuss the results of our study on the temperature of evaporation and temperature-dependent vapor pressure of sodium, potassium, and cesium perrhenates in relation to rhenium volatilization behavior observed during melting of simulated waste glass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Treatment of brackish water reverse osmosis brine using only solar energy

Post-treatment of brine produced by reverse osmosis (RO) is a great challenge as it often requires high energy input and works under extreme operating conditions. In this study, brine from a RO plant in El Paso, TX USA was successfully treated using a pilot-scale nanophotonics enhanced solar membrane distillation (NESMD) system. The novel NESMD reactor has a nanophotonic membrane surface area of 0.2 m 2 and an internal heat recovery system to recover the latent heat released during vapor condensation. By utilizing a sweeping gas operational mode under real solar irradiation (585–827 W m -2 ), the NESMD realized successful desalination of RO brine with the membrane flux reaching 0.45–0.65 kg m -2 h -1 and total dissolved solids (TDS) removal greater than 99.5% without an external heat condenser. The decrease in the feed flow rate to the evaporation channel of the NESMD system led to an increase in the gained output ratio (GOR) from 0.35 to 0.62. We report to the best of our knowledge, this is the largest photothermal reactor utilized for the desalination of real RO brine under practical solar irradiation. Compared with conventional brine treatment processes that require high temperature or pressure, the NESMD desalinates RO brine at near-ambient temperature and pressure with free solar energy, providing a promising approach for water desalination, and RO brine post treatment.

42 ENGINEERING↗

Measuring Q₀ in LCLS-II Cryomodules Using Helium Liquid Level

The nitrogen-doped cavities used in the Linac Coherent Light Source II (LCLS-II) cryomodules have shown an unprecedented high Q₀ in vertical and cryomodule testing compared with cavities prepared with standard methods. While demonstration of high Q₀ in the test stand has been achieved, maintaining that performance in the linac is critical to the success of LCLS-II and future accelerator projects. The LCLS-II cryomodules required a novel method of measuring Q₀, due to hardware incompatibilities with existing procedures. Initially developed at Jefferson Lab during cryomodule acceptance testing before being used in the tunnel at SLAC, we use helium liquid level data to estimate the heat generated by cavities. We first establish the relationship between the rate of helium evaporation from known heat loads using electric heaters, and then use that relationship to determine heat from an RF load. Here we present the full procedure along with the development process, lessons learned, and reproducibility while demonstrating for the first time that world record Q₀ can be maintained within the real accelerator environment.

43 PARTICLE ACCELERATORS↗