Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical power system simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Dynamic Response Testing in an Electrically Heated Reactor Test Facility

Non-nuclear testing can be a valuable tool in development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system (Bragg-Sitton, 2005). The current paper applies the same testing methodology to a direct drive gas cooled reactor system, demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. In each testing application, core power transients were controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. Although both system designs utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility.

Bragg-Sitton, Shannon M.↗

Benchmarking of Planning Models Using Recorded Dynamics

Power system planning extensively uses model simulation to understand the dynamic behaviors and determine the operating limits of a power system. Model quality is key to the safety and reliability of electricity delivery. Planning model benchmarking, or model validation, has been one of the central topics in power engineering studies for years. As model validation aims at obtaining reasonable models to represent dynamic behavior of power system components, it has been essential to validate models against actual measurements. The development of phasor technology provides such measurements and represents a new opportunity for model validation as phasor measurements can capture power system dynamics with high-speed, time-synchronized data. Previously, methods for rigorous comparison of model simulation and recorded dynamics have been developed and applied to quantify model quality of power plants in the Western Electricity Coordinating Council (WECC). These methods can locate model components which need improvement. Recent work continues this effort and focuses on how model parameters may be calibrated to match recorded dynamics after the problematic model components are identified. A calibration method using Extended Kalman Filter technique is being developed. This paper provides an overview of prior work on model validation and presents new development on the calibration method and initial results of model parameter calibration.

Huang, Zhenyu↗

Electromagnetic Transient (EMT) Simulation Algorithms for Evaluation of Large-Scale Extreme Fast Charging Systems (T&D Models)

Simulation of high-fidelity models of extreme fast charging (XFC) systems and large-area power grids with many XFCs can be time consuming in traditional simulators. Traditional simulators use a single method of discretization for all the components that results in imposing a large computational burden of inverting a large matrix as well as increased computations related to single method of discretization (that is typically a trapezoidal method). To overcome the problem of simulating large-area power grids with many XFCs, in this paper, advanced numerical simulation algorithms are applied for the first time together to reduce the dimension of matrix inversion. Here, the algorithms include numerical stiffness-based segregation, time constant-based segregation, clustering and aggregation on differential algebraic equations (DAEs), and multi-order integration approaches. These algorithms apply multiple discretization algorithms rather than a single discretization algorithm that further reduces the computational burden. The approaches mentioned here have resulted in speed-up of up to 18x in the simulation of a single distribution system with 15 XFCs and of up to 271x in the simulation of a transmission-distribution system with 300 XFCs in multiple distribution feeders with respect to conventional simulators (like power systems computer aided design [PSCAD]).

42 ENGINEERING↗

Impacts of different data averaging times on statistical analysis of distributed domestic photovoltaic systems

The trend of increasing application of distributed generation with solar photovoltaics (PV-DG) suggests that a widespread integration in existing low-voltage (LV) grids is possible in the future. With massive integration in LV grids, a major concern is the possible negative impacts of excess power injection from on-site generation. For power-flow simulations of such grid impacts, an important consideration is the time resolution of demand and generation data. This paper investigates the impact of time averaging on high-resolution data series of domestic electricity demand and PV-DG output and on voltages in a simulated LV grid. Effects of 10-minutely and hourly averaging on descriptive statistics and duration curves were determined. Although time averaging has a considerable impact on statistical properties of the demand in individual households, the impact is smaller on aggregate demand, already smoothed from random coincidence, and on PV-DG output. Consequently, the statistical distribution of simulated grid voltages was also robust against time averaging. The overall judgement is that statistical investigation of voltage variations in the presence of PV-DG does not require higher resolution than hourly. (author)

24 POWER TRANSMISSION AND DISTRIBUTION↗

2.1.3.404 - WEC Array Power Management and Output Simulation Tool

An array of wave energy converter (WEC) devices has variations in power output due to the chaotic nature of the waves. Eliminating or mitigating the power fluctuations is important for reducing the integration impacts of WEC plants in both distribution and transmission grids, and in standalone isolated power systems. Reduced variability of WEC-generated power in combination with energy storage or power management control at each WEC and at the array level will help increasing hosting capacity of distribution feeders for this type of variable renewable generation, and minimization of electric losses. To reduce risks and risk perception, gain key stakeholder acceptance, and enable developers to design effective and compatible energy plants with arrays of WEC devices, it requires the use of modeling tools to simulate the resource environment, device dynamics, utility power system response, as well as the development of an interface for an array controller. The project will create a publicly accessible numerical modeling framework to empower the wave energy sector to design projects of various scales (kW-100s MW), which are optimized on a plant performance basis and are compatible with different power systems and wave conditions. The framework will integrate with WEC-Sim, a wave environment model (SWAN-FUNWAVE), as well as established relevant electrical analysis tools, to model the grid system and interconnection, and optimize power output and power management for the WEC array.

POWER TRANSMISSION AND DISTRIBUTION,TIDAL AND WAVE↗

Load Component Database of Household Appliances and Small Office Equipment

This paper discusses the development of a load component database for household appliances and office equipment. To develop more accurate load models at both transmission and distribution level, a better understanding on the individual behaviors of home appliances and office equipment under power system voltage and frequency variations becomes more and more critical. Bonneville Power Administration (BPA) has begun a series of voltage and frequency tests against home appliances and office equipments since 2005. Since 2006, Researchers at Pacific Northwest National Laboratory has collaborated with BPA personnel and developed a load component database based on these appliance testing results to facilitate the load model validation work for the Western Electricity Coordinating Council (WECC). In this paper, the testing procedure and testing results are first presented. The load model parameters are then derived and grouped. Recommendations are given for aggregating the individual appliance models to feeder level, the models of which are used for distribution and transmission level studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IGMS: An Integrated ISO-to-Appliance Scale Grid Modeling System

This paper describes the Integrated Grid Modeling System (IGMS), a novel electric power system modeling platform for integrated transmission-distribution analysis that co-simulates off-the-shelf tools on high performance computing (HPC) platforms to offer unprecedented resolution from ISO markets down to appliances and other end uses. Specifically, the system simultaneously models hundreds or thousands of distribution systems in co-simulation with detailed Independent System Operator (ISO) markets and AGC-level reserve deployment. IGMS uses a new MPI-based hierarchical co-simulation framework to connect existing sub-domain models. Our initial efforts integrate opensource tools for wholesale markets (FESTIV), bulk AC power flow (MATPOWER), and full-featured distribution systems including physics-based end-use and distributed generation models (many instances of GridLAB-D[TM]). The modular IGMS framework enables tool substitution and additions for multi-domain analyses. This paper describes the IGMS tool, characterizes its performance, and demonstrates the impacts of the coupled simulations for analyzing high-penetration solar PV and price responsive load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An EMTP system level model of the PMAD DC test bed

A power management and distribution direct current (PMAD DC) test bed was set up at the NASA Lewis Research Center to investigate Space Station Freedom Electric Power Systems issues. Efficiency of test bed operation significantly improves with a computer simulation model of the test bed as an adjunct tool of investigation. Such a model is developed using the Electromagnetic Transients Program (EMTP) and is available to the test bed developers and experimenters. The computer model is assembled on a modular basis. Device models of different types can be incorporated into the system model with only a few lines of code. A library of the various model types is created for this purpose. Simulation results and corresponding test bed results are presented to demonstrate model validity.

Dravid, Narayan V.↗

Simulation Accelerator

Under a NASA SBIR (Small Business Innovative Research) contract, (NAS5-30905), EAI Simulation Associates, Inc., developed a new digital simulation computer, Starlight(tm). With an architecture based on the analog model of computation, Starlight(tm) outperforms all other computers on a wide range of continuous system simulation. This system is used in a variety of applications, including aerospace, automotive, electric power and chemical reactors.

Source record↗

Hubble Space Telescope six-battery nickel-cadmium mission simulation test

A simulation test of the six-battery nickel-cadmium mission to determine battery life and electrical power system (EPS) performance characteristics for the Hubble Space Telescope (HST) program, is described. The basic HST power system requirements are to provide power generation, energy storage, and EPS control and distribution for 2.5 years with the nickel-cadmium (NiCd) batteries at an end of life solar array of 2 years. Mission simulation life testing begain in April of 1986, and the batteries have completed their 2.5 year mission requirement. Conditions as close as practical to the actual predicted mission profiles were used. These included solar array degradation, load variations, beta angle changes, temperature changes (with excursions to 10 C), battery reconditioning, safemode simulations, and off-normal roll activities. Discounting system cycling interruptions caused by hardware, software, human error, and periodic updates and revisions, the HST EPS breadboard hardware operated continuously for 30 months and demonstrated the power system's ability to meet the HST requirement.

Jackson, Lorna G.↗

Hardware-based Advanced Electromagnetic Transient Simulation for A Large-Scale PV Plant in Real Time Digital Simulator

Power electronics-based resources, such as high-voltage direct current (HVdc) substations, photovoltaic (PV) plants, wind plants, electric vehicle charging stations, and energy storage systems, are increasingly being integrated within the power grid. Recently, multiple reports have emphasized the necessity for high-fidelity electromagnetic transient (EMT) simulations of these large-scale power electronics-based resources to accurately understand their behavior in power grids. However, performing hardware-based EMT simulations with high-fidelity models for such large power electronics systems is challenging due to the small time-step requirements and the involvement of a large number of states. This paper presents the implementation of hardware-based high-fidelity EMT dynamic model of a large-scale PV plant, accomplished through custom model development using the specific-C language in real-time digital simulator hardware (RTDS) and software (RSCAD).

Choi, Jongchan↗

Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI-XFC)

Review of the FY20 and FY21 progress for the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI-XFC) project. GEMINI-XFC will use first-of-a-kind integrated high-fidelity grid and transport modeling to identify effective pathways for widespread electrification, to design and evaluate integrated vehicle-grid control schemes, and to optimize electric vehicle integration at a full regional scale with individual customer resolution.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Power processing methodology

Discussion of the interim results of a program to investigate the feasibility of formulating a methodology for the modeling and analysis of aerospace electrical power processing systems. The object of the total program is to develop a flexible engineering tool which will allow the power processor designer to effectively and rapidly assess and analyze the tradeoffs available by providing, in one comprehensive program, a mathematical model, an analysis of expected performance, simulation, and a comparative evaluation with alternative designs. This requires an understanding of electrical power source characteristics and the effects of load control, protection, and total system interaction.

Fegley, K. A.↗

An integrated transportation-power system model for a decarbonizing world

Rising demand for electricity from electric vehicles (EVs) will require new paradigms to guarantee reliable and low-cost electricity. This study couples an agent-based travel demand simulator and an electricity grid model to assess the economic costs of supplying power to meet EVs' added demand across the Chicago region. Results suggest that shifting from personal EVs to a fleet of shared, fully-automated all-electric vehicles (SAEVs) could lower per-mile emissions, congestion, and embodied vehicle and charging infrastructure emissions. Further, the results should compel policymakers to shift the cost of providing power onto commercial customers, like electric ride-hail fleets, through price-indexed electricity prices, which can shift charging to off-peak periods or away from resource-scarce hours.

Integrated modeling↗

Design and Cosimulation of Hierarchical Architecture for Demand Response Control and Coordination

Demand response (DR) plays a key role for optimum asset utilization and to avoid or delay the need of new infrastructure investment. However, coordinated execution of multiple DRs is desired to maximize the DR benefits. In this paper, we propose a hierarchical DR architecture (HDRA) to control and coordinate the performance of various DR categories such that the operation of every DR category is backed-up by time delayed action of the others. A reliable, cost-effective communication infrastructure based on ZigBee, WiMAX, and fibers is designed to facilitate the HDRA execution. The performance of the proposed HDRA is demonstrated from the power system and communication perspectives in a cosimulation environment applied to a 0.4 kV/400 kVA real distribution network considering electric vehicles as a potential DR resource (DRR). The power simulation is performed employing a real time digital simulator whereas the communication simulation is performed using OMNeT++. Finally, the HDRA performance demonstrated the maximum utilization of available DR potential by facilitating simultaneous execution of multiple DRs and enabling participation of single DRR for multiple grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-Loop Simulation of a Distribution System with Air Conditioners under Model Predictive Control: Preprint

Many have proposed that responsive load provided by distributed energy resources (DERs) and demand response (DR) are an option to provide flexibility to the grid and especially to distribution feeders. However, because responsive load involves a complex interplay between tariffs and DER and DR technologies, it is challenging to test and evaluate options without negatively impacting customers. This paper describes a hardware-in-the-loop (HIL) simulation system that has been developed to reduce the cost of evaluating the impact of advanced controllers (e.g., model predictive controllers) and technologies (e.g., responsive appliances). The HIL simulation system combines large-scale software simulation with a small set of representative building equipment hardware. It is used to perform HIL simulation of a distribution feeder and the loads on it under various tariff structures. In the reported HIL simulation, loads include many simulated air conditioners and one physical air conditioner. Independent model predictive controllers manage operations of all air conditioners under a time-of-use tariff. Results from this HIL simulation and a discussion of future development work of the system are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the potential development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a liquid metal cooled reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗