Search NASA⌕ Search

SEARCH · Search NASA

Results for “Emittance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Tuning the spectral emittance of α-SiC open-cell foams up to 1300 K with their macro porosity

A simple and robust analytical model is used to finely predict the spectral emittance under air up to 1300 K of α-SiC open-cell foams constituted of optically thick struts. The model integrates both the chemical composition and the macro-porosity and is valid only if foams have volumes higher than their Representative Elementary Volumes required for determining their emittance. Infrared emission spectroscopy carried out on a doped silicon carbide single crystal associated to homemade numerical tools based on 3D meshed images (Monte Carlo Ray Tracing code, foam generator) make possible to understand the exact role of the cell network in emittance. Finally, one can tune the spectral emittance of α-SiC foams up to 1300 K by simply changing their porosity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasi-deterministic localization of Er emitters in thin film TiO 2 through submicron-scale crystalline phase control

With their shielded 4f orbitals, rare-earth ions (REIs) offer optical and electron spin transitions with good coherence properties even when embedded in a host crystal matrix, highlighting their utility as promising quantum emitters and memories for quantum information processing. Among REIs, trivalent erbium (Er 3+ ) uniquely has an optical transition in the telecom C-band, ideal for transmission over optical fibers, making it well suited for applications in quantum communication. The deployment of Er 3+ emitters into a thin film TiO 2 platform has been a promising step toward scalable integration; however, like many solid-state systems, the deterministic spatial placement of quantum emitters remains an open challenge. Here, we investigate laser annealing as a means to locally tune the optical resonance of Er 3+ emitters in TiO 2 thin films on Si. Using both nanoscale x-ray diffraction measurements and cryogenic photoluminescence spectroscopy, we show that tightly focused below-gap laser annealing can induce anatase to rutile phase transitions in a nearly diffraction-limited area of the films and improve local crystallinity through grain growth. As a percentage of Er:TiO 2 is converted to rutile, the Er 3+ optical transition blueshifts by 13 nm. We explore the effects of changing laser annealing time and show that the amount of optically active Er:rutile increases linearly with laser power. We additionally demonstrate local phase conversion on microfabricated Si structures, which holds significance for quantum photonics.

36 MATERIALS SCIENCE↗

SEARCHING FOR z {approx} 7.7 Ly{alpha} EMITTERS IN THE COSMOS FIELD WITH NEWFIRM

The study of Ly{alpha} emission in the high-redshift universe is a useful probe of the epoch of reionization, as the Ly{alpha} line should be attenuated by the intergalactic medium (IGM) at low to moderate neutral hydrogen fractions. Here we present the results of a deep and wide imaging search for Ly{alpha} emitters in the Cosmological Evolution Survey field. We have used two ultra-narrowband filters (filter width of {approx}8-9 A) on the NOAO Extremely Wide-Field Infrared Mosaic camera, installed on the Mayall 4 m telescope at Kitt Peak National Observatory, in order to isolate Ly{alpha} emitters at z = 7.7; such ultra-narrowband imaging searches have proved to be excellent at detecting Ly{alpha} emitters. We found 5{sigma} detections of four candidate Ly{alpha} emitters in a survey volume of 2.8 Multiplication-Sign 10{sup 4} Mpc{sup 3} (total survey area {approx}760 arcmin{sup 2}). Each candidate has a line flux greater than 8 Multiplication-Sign 10{sup -18} erg s{sup -1} cm{sup -2}. Using these results to construct a luminosity function and comparing to previously established Ly{alpha} luminosity functions at z = 5.7 and z = 6.5, we find no conclusive evidence for evolution of the luminosity function between z = 5.7 and z = 7.7. Statistical Monte Carlo simulations suggest that half of these candidates are real z = 7.7 targets, and spectroscopic follow-up will be required to verify the redshift of these candidates. However, our results are consistent with no strong evolution in the neutral hydrogen fraction of the IGM between z = 5.7 and z = 7.7, even if only one or two of the z = 7.7 candidates are spectroscopically confirmed.

79 ASTRONOMY AND ASTROPHYSICS↗

Strongly coupling a cavity to inhomogeneous ensembles of emitters: Potential for long-lived solid-state quantum memories

We investigate theoretically the coupling of a cavity mode to a continuous distribution of emitters. We discuss the influence of the emitters' inhomogeneous broadening on the existence and on the coherence properties of the polaritonic peaks. We find that their coherence depends crucially on the shape of the distribution and not only on its width. Under certain conditions the coupling to the cavity protects the polaritonic states from inhomogeneous broadening, resulting in a longer storage time for a quantum memory based on emitter ensembles. When two different ensembles of emitters are coupled to the resonator, they support a peculiar collective dark state, which is also very attractive for the storage of quantum information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid thermal emittance and quantum efficiency mapping of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets

Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the mapping procedure and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radio-frequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to 1.14 mu m/nun and from 4.6% to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper.

43 PARTICLE ACCELERATORS↗

Transverse emittance growth due to rf noise in crab cavities: Theory, measurements, cure, and high luminosity LHC estimates

The High-Luminosity LHC (HL-LHC) upgrade with planned operation from 2029 onward has a goal of achieving a tenfold increase in the integrated number of recorded collisions thanks to a doubling of the intensity per bunch ( 2.2 × 10 11 protons) and a reduction of β * (the β value in the two high luminosity detectors, namely ATLAS and CMS) to 15 cm. Such an increase in recorded collisions would significantly expedite new discoveries and exploration. Crab cavities are an important component of the HL-LHC upgrade and will contribute strongly to achieving an increase in the number of recorded collisions. However, noise injected through the crab cavity radio frequency (rf) system could cause significant transverse emittance growth and limit luminosity lifetime. We presented a theoretical formalism relating transverse emittance growth to rf noise in an earlier work. In this follow-up paper, we summarize measurements in the super-proton synchrotron (SPS) at CERN that validate the theory, we present estimates of the emittance growth rates using state-of-the-art rf and low-level rf (LLRF) technologies, and we set the rf noise specifications to achieve acceptable performance. A novel dedicated feedback system acting through the crab cavities to mitigate emittance growth will be required. In this work, we develop a theoretical formalism to evaluate the performance of such a feedback system in any collider, identify limiting components, present simulation results to validate these studies, and derive key design parameters for an HL-LHC implementation of such a feedback system. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Low Emittance, High Brilliance Relativistic Electron Beams from a Laser-Plasma Accelerator

Progress in laser wakefield accelerators indicates their suitability as a driver of compact free-electron lasers (FELs). High brightness is defined by the normalized transverse emittance, which should be less than 1{pi} mm mrad for an x-ray FEL. We report high-resolution measurements of the emittance of 125 MeV, monoenergetic beams from a wakefield accelerator. An emittance as low as 1.1{+-}0.1{pi} mm mrad is measured using a pepper-pot mask. This sets an upper limit on the emittance, which is comparable with conventional linear accelerators. A peak transverse brightness of 5x10{sup 15} A m{sup -1} rad{sup -1} makes it suitable for compact XUV FELs.

43 PARTICLE ACCELERATORS↗

Direct Measurement of the Double Emittance Minimum in the Beam Dynamics of the Sparc High-Brightness Photoinjector

In this Letter we report the first experimental observation of the double emittance minimum effect in the beam dynamics of high-brightness electron beam generation by photoinjectors; this effect, as predicted by the theory, is crucial in achieving minimum emittance in photoinjectors aiming at producing electron beams for short wavelength single-pass free electron lasers. The experiment described in this Letter was performed at the SPARC photoinjector site, during the first stage of commissioning of the SPARC project. The experiment was made possible by a newly conceived device, called an emittance meter, which allows a detailed and unprecedented study of the emittance compensation process as the beam propagates along the beam pipe.

43 PARTICLE ACCELERATORS↗

Transverse Emittance and Current of Multi-GeV Trapped Electrons in a Plasma Wakefield Accelerator

Multi-GeV trapped electron bunches in a plasma wakefield accelerator (PWFA) are observed with normalized transverse emittance divided by peak current, {epsilon}{sub N,x}/I{sub t}, below the level of 0.2 {micro}m/kA. A theoretical model of the trapped electron emittance, developed here, indicates that emittance scales inversely with the square root of the plasma density in the nonlinear 'bubble' regime of the PWFA. This model and simulations indicate that the observed values of {epsilon}{sub N,x}/I{sub t} result from multi-GeV trapped electron bunches with emittances of a few {micro}m and multi-kA peak currents.

43 PARTICLE ACCELERATORS↗

Minimum emittance in electron storage rings with uniform or nonuniform dipoles.

A simple treatment of minimum emittance theory in storage rings is presented, favoring vector and matrix forms for a more concise picture. Both conventional uniform dipoles and nonuniform dipoles with bending radius variation are treated. Simple formulas are given for computing the minimum emittance, optimal lattice parameters, as well as effects of nonoptimal parameters. For nonuniform dipoles, analytical results are obtained for a three-piece sandwich dipole model. Minimization of the effective emittance for light sources is given in detail. Usefulness of gradient and/or nonuniform dipoles for reducing the effective emittance is addressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy

Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation. Methods: Proton therapy using a beam on-line PET system mounted on a rotating gantry port (BOLPs-RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs-RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs-RGp. Results: The decay curves for measured activity were able to be approximated using two or three half-life values regardless of the treatment site. The activity of half-life value of about 2 min was important for a confirmation of the proton irradiated volume. Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs-RGp. For the monitoring of the proton irradiated volume, the detection of {sup 15}O generated in a human body was important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei in preparation of clinical application

Purpose: The purpose of this study is to develop a new calculation algorithm that is satisfactory in terms of the requirements for both accuracy and calculation time for a simulation of imaging of the proton-irradiated volume in a patient body in clinical proton therapy. Methods: The activity pencil beam algorithm (APB algorithm), which is a new technique to apply the pencil beam algorithm generally used for proton dose calculations in proton therapy to the calculation of activity distributions, was developed as a calculation algorithm of the activity distributions formed by positron emitter nuclei generated from target nuclear fragment reactions. In the APB algorithm, activity distributions are calculated using an activity pencil beam kernel. In addition, the activity pencil beam kernel is constructed using measured activity distributions in the depth direction and calculations in the lateral direction. {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei were determined as the major target nuclei that constitute a human body that are of relevance for calculation of activity distributions. In this study, ''virtual positron emitter nuclei'' was defined as the integral yield of various positron emitter nuclei generated from each target nucleus by target nuclear fragment reactions with irradiated proton beam. Compounds, namely, polyethylene, water (including some gelatin) and calcium oxide, which contain plenty of the target nuclei, were irradiated using a proton beam. In addition, depth activity distributions of virtual positron emitter nuclei generated in each compound from target nuclear fragment reactions were measured using a beam ON-LINE PET system mounted a rotating gantry port (BOLPs-RGp). The measured activity distributions depend on depth or, in other words, energy. The irradiated proton beam energies were 138, 179, and 223 MeV, and measurement time was about 5 h until the measured activity reached the background level. Furthermore, the activity pencil beam data were made using the activity pencil beam kernel, which was composed of the measured depth data and the lateral data including multiple Coulomb scattering approximated by the Gaussian function, and were used for calculating activity distributions. Results: The data of measured depth activity distributions for every target nucleus by proton beam energy were obtained using BOLPs-RGp. The form of the depth activity distribution was verified, and the data were made in consideration of the time-dependent change of the form. Time dependence of an activity distribution form could be represented by two half-lives. Gaussian form of the lateral distribution of the activity pencil beam kernel was decided by the effect of multiple Coulomb scattering. Thus, the data of activity pencil beam involving time dependence could be obtained in this study. Conclusions: The simulation of imaging of the proton-irradiated volume in a patient body using target nuclear fragment reactions was feasible with the developed APB algorithm taking time dependence into account. With the use of the APB algorithm, it was suggested that a system of simulation of activity distributions that has levels of both accuracy and calculation time appropriate for clinical use can be constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-03: A Comprehensive Comparison Between Alpha and Beta Emitters for Cancer Radioimmunotherapy

Purpose: The purpose of this study is to perform a comprehensive comparison of the therapeutic efficacy and cytotoxicity of alpha and beta emitters for Radioimmunotherapy (RIT). For each stage of cancer development, specific models were built for the separate objectives of RIT to be addressed:a) kill isolated cancer cells in transit in the lymphatic and vascular circulation,b) regress avascular cell clusters,c) regress tumor vasculature and tumors. Methods: Because of the nature of short range, high LET alpha and long energy beta radiation and heterogeneous antigen expression among cancer cells, the microdosimetric approach is essential for the RIT assessment. Geant4 based microdosimetric models are developed for the three different stages of cancer progression: cancer cells, cell clusters and tumors. The energy deposition, specific energy resulted from different source distribution in the three models was calculated separately for 4 alpha emitting radioisotopes ({sup 211}At, {sup 213}Bi, {sup 223}Ra and {sup 225}Ac) and 6 beta emitters ({sup 32}P, {sup 33}P, {sup 67}Cu, {sup 90}Y, {sup 131}I and {sup 177}Lu). The cell survival, therapeutic efficacy and cytotoxicity are determined and compared between alpha and beta emitters. Results: We show that internal targeted alpha radiation has advantages over beta radiation for killing isolated cancer cells, regressing small cell clusters and also solid tumors. Alpha particles have much higher dose specificity and potency than beta particles. They can deposit 3 logs more dose than beta emitters to single cells and solid tumor. Tumor control probability relies on deep penetration of radioisotopes to cancer cell clusters and solid tumors. Conclusion: The results of this study provide a quantitative understanding of the efficacy and cytotoxicity of RIT for each stage of cancer development.

60 APPLIED LIFE SCIENCES↗

Room-temperature single-photon emitters in silicon nitride

Single-photon emitters are essential in enabling several emerging applications in quantum information technology, quantum sensing, and quantum communication. Scalable photonic platforms capable of hosting intrinsic or embedded sources of single-photon emission are of particular interest for the realization of integrated quantum photonic circuits. Here, we report on the observation of room-temperature single-photon emitters in silicon nitride (SiN) films grown on silicon dioxide substrates. Photophysical analysis reveals bright (>10 5 counts/s), stable, linearly polarized, and pure quantum emitters in SiN films with a second-order autocorrelation function value at zero time delay g (2) (0) below 0.2 at room temperature. We suggest that the emission originates from a specific defect center in SiN because of the narrow wavelength distribution of the observed luminescence peak. Single-photon emitters in SiN have the potential to enable direct, scalable, and low-loss integration of quantum light sources with a well-established photonic on-chip platform.

42 ENGINEERING↗

Kinetics of system of emitters and nonequilibrium electromagnetic field

A new step in research into the Dicke model kinetics is proposed on the basis of the Bogolyubov reduced description method. A more precise description of the emitter subsystem and electromagnetic field is considered. New reduced description parameters — emitter energy density and binary correlation functions of electric and magnetic field amplitudes — open the way to investigating non-uniform systems of two-level emitters and nonequilibrium electromagnetic field with its correlation properties. Kinetic equations for such systems have been obtained in terms of electrodynamics of continuous media consisting of two-level emitters. Material equations for corresponding media are analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrical properties of the InP/InGaAs pnp heterostructure-emitter bipolar transistor

The dc performances of an InP/InGaAs pnp heterostructure-emitter bipolar transistor are investigated by theoretical analysis and experimental results. Though the valence band discontinuity at the InP/InGaAs heterojunction is relatively large, the addition of a heavily-doped as well as thin p{sup +}-InGaAs emitter layer between p-InP confinement and n{sup +}-InGaAs base layers effectively eliminates the potential spike at emitter-base junction and simultaneously lowers the emitter-collector offset voltage and increases the potential barrier for electrons. Experimentally, a high current gain of 88 and a low offset voltage of 54 mV have been achieved.

36 MATERIALS SCIENCE↗

Design of emitter structures based on resonant perfect absorption for thermophotovoltaic applications

We report a class of thermophotovoltaic emitter structures built upon planar films that support resonant modes, known as perfectly-absorbing modes, that facilitate an exceptional optical response for selective emission. These planar structures have several key advantages over previously-proposed designs for TPV applications: they are simple to fabricate, are stable across a range of temperatures and conditions, and are capable of achieving some of the highest spectral efficiencies reported of any class of emitter structure. Utilization of these emitters leads to exceptionally high device efficiencies under low operating temperature conditions, which should open new opportunities for waste heat management. We present a theoretical framework for understanding this performance, and show that this framework can be leveraged as a search algorithm for promising candidate structures. In addition to providing an efficient theoretical methodology for identifying high-performance emitter structures, our methodology provides new insight into underlying design principles and should pave way for future design of structures that are simple to fabricate, temperature stable, and possess exceptional optical properties. (C) 2015 Optical Society of America

Foley, Jonathan J.↗

Thermophotovoltaics with spectral and angular selective doped-oxide thermal emitters

Deliberate control of thermal emission properties using nanophotonics has improved a number of applications including thermophotovoltaics (TPV), radiative cooling and infrared spectroscopy. In this work, we study the effect of simultaneous control of angular and spectral properties of thermal emitters on the efficiencies of TPV systems. While spectral selectivity reduces sub-bandgap losses, angular selectivity is expected to enhance view factors at larger separation distances and hence to provide flexibilities in cooling the photovoltaic converter. We propose a design of an angular and spectral selective thermal emitter based on waveguide perfect absorption phenomena in epsilon-near-zero thin-films. Aluminum-doped Zinc-Oxide is used as an epsilon-near-zero material with a cross-over frequency in the near-infrared. A high contrast grating is designed to restrict the emission in a range of angles around the normal direction, while an integrated filter ensures spectral selectivity to reduce sub-bandgap losses. Theoretical analysis shows an expected relative enhancement of the TPV system efficiency of at least 32% using selective emitters with ideal angular and spectral selectivity at large separation distances compared to a blackbody. This enhancement factor, however, reduces to 3.9% with non-ideal selective emitters. This big reduction of the efficiency is attributed to sub-bandgap losses, off-angular losses and high-temperature dependence of optical constants.

42 ENGINEERING↗