Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy efficient computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Issues in Bi-Directional Interoperability between BIM and BEM

The state-of-the-art interoperability between Building Information Modeling (BIM) and Building Energy Modeling (BEM) is mainly one-way. BEM software like EnergyPlus takes design input from BIM and simulates the energy consumption of the building. BIM, however, is unable to leverage energy simulation results from BEM smoothly. This lack of bi-directional interoperability between BIM and BEM prevents buildings from seeking more energy-efficient design options and limits BIM applications in optimal generative design. In this research, the authors have conducted the following activities related to two-way interoperability between BIM and BEM: (1) surveyed its current status through literature review, (2) investigated barriers to the bi-directional interoperability, and (3) suggested possible approaches to enable bi-directional interoperability and research outlook in the field. As a result, the authors have identified three main barriers to BIM BEM interoperability, namely, inefficient collaboration, limited scope in information transformation, and lack of BEM to BIM transformation. Future directions are suggested to address these barriers.

building design↗

Computational Investigation of a CO 2 Conversion Strategy via Diels–Alder Reaction in a Carbon Capture Solvent

Molecular-level insights into reactive separations are crucial for the design of new conversion pathways of carbon dioxide (CO 2 ). This work explores a postulated pathway that directs CO 2 to undergo inverse-electron-demand Diels–Alder reactions to produce heterocycles using the CO 2 chemically fixed on water-lean solvent molecules. Density functional theory calculations are applied to evaluate the lowest unoccupied molecular orbital (LUMO) energies of three types of reactants (1,3-butadiene, 1,3-cyclohexadiene, and 1,2,4,5-tetrazine) with various functional substituents. These calculations also provide a data set (5.8k data) for developing a machine learning model to efficiently predict LUMO energies. A computational screening of LUMO energies for an additional 47k diene and tetrazine candidates is performed, and a list of candidates with lowered LUMO energies by electron-withdrawing substituents is provided. These candidates are further examined by their reaction energy barriers computed from the interatomic potential or density functional theory. Two major energy barriers are identified, one for the proton transfer within the water-lean solvent and the other for the CO 2 transfer from the solvent molecule to the reactant candidate (diene or tetrazine). The functional substituents have a more significant impact on the second barrier but a very slight one on the first barrier. This exploratory work demonstrates a new possibility for guiding experimental efforts toward the chemical conversion of fixated CO 2 to value-added compounds.

Chemical reactions↗

Ambient and Initial Temperature Effects on Energy Consumption Rate Modeled in FASTSim

Ambient and initial temperatures significantly impact the energy consumption rate (ECR) of battery electric vehicles (BEVs) due to auxiliary loads and the temperature dependence of battery efficiency. This study introduces a streamlined, physics-based thermal modeling approach within the FASTSim tool that bridges the gap between oversimplified constant-load models and computationally expensive high-fidelity simulations. By employing a lumped thermal mass framework, the model captures fundamental energy balances and critical non-linear energy penalties while maintaining the computational efficiency required for expansive sensitivity studies. The simulations evaluated a compact BEV hatchback with a resistive heater over city (UDDS) and highway (HWFET) test cycles. Compared to a 22 degrees Celsius initial and ambient temperature baseline, a -7 degrees Celsius initial/ambient temperature resulted in a 221% increase in the ECR for the city cycle and a 100% increase for the highway cycle. Conversely, a 45 degrees Celsius initial / 40 degrees Celsius ambient temperature resulted in a 40% increase for UDDS and an 18% increase for HWFET. These results demonstrate that while cold conditions impose the most severe energy penalties due to resistive heating, the impact is consistently more pronounced in city driving where auxiliary loads represent a larger proportion of total energy. This lightweight yet robust framework enables researchers to rapidly quantify BEV thermal sensitivity across diverse climates without the need for high-overhead simulation environments.

33 ADVANCED PROPULSION SYSTEMS↗

Beam-wave interaction analysis of a 42 GHz, 200 kW CW gyrotron

In this paper, the self-consistent large-signal formulation is used to study the beam-wave interaction mechanism in a gyrotron oscillator. The nonlinear interaction has been computed by solving the set of self-consistent nonlinear equations along the interaction length using numerical method. Consequently, the computation of energy, phase, output power, and efficiency of a gyrotron is made. The computed results were found to be matching with the published results. A 42 GHz, 200 kW output power gyrotron operating in TE{sub 03} mode is analysed using this analysis and results found meeting desired specifications. (author)

43 PARTICLE ACCELERATORS↗

Computing with Spikes: The Advantage of Fine-Grained Timing

Neural-inspired spike-based computing machines often claim to achieve considerable advantages in terms of energy and time efficiency by using spikes for computation and communication. However, fundamental questions about spike-based computation remain unanswered. For instance, how much advantage do spike-based approaches have over conventional methods, and under what circumstances does spike-based computing provide a comparative advantage? Simply implementing existing algorithms using spikes as the medium of computation and communication is not guaranteed to yield an advantage. Here, we demonstrate that spike-based communication and computation within algorithms can increase throughput, and they can decrease energy cost in some cases. We present several spiking algorithms, including sorting a set of numbers in ascending/descending order, as well as finding the maximum or minimum or median of a set of numbers. We also provide an example application: a spiking median-filtering approach for image processing providing a low-energy, parallel implementation. Furthermore, the algorithms and analyses presented here demonstrate that spiking algorithms can provide performance advantages and offer efficient computation of fundamental operations useful in more complex algorithms.

97 MATHEMATICS AND COMPUTING↗

Exploring Applications of Random Walks on Spiking Neural Algorithms

Neuromorphic computing has many promises in the future of computing due to its energy efficient and scalable implementation. Here we extend a neural algorithm that is able to solve the diffusion equation PDE by implementing random walks on neuromorphic hardware. Additionally, we introduce four random walk applications that use this spiking neural algorithm. The four applications currently implemented are: generating a random walk to replicate an image, finding a path between two nodes, finding triangles in a graph, and partitioning a graph into two sections. We then made these four applications available to be implemented on software using a graphical user interface (GUI).

97 MATHEMATICS AND COMPUTING↗

Tunneling current-controlled spin states in few-layer van der Waals magnets

Abstract Effective control of magnetic phases in two-dimensional magnets would constitute crucial progress in spintronics, holding great potential for future computing technologies. Here, we report a new approach of leveraging tunneling current as a tool for controlling spin states in CrI 3 . We reveal that a tunneling current can deterministically switch between spin-parallel and spin-antiparallel states in few-layer CrI 3 , depending on the polarity and amplitude of the current. We propose a mechanism involving nonequilibrium spin accumulation in the graphene electrodes in contact with the CrI 3 layers. We further demonstrate tunneling current-tunable stochastic switching between multiple spin states of the CrI 3 tunnel devices, which goes beyond conventional bi-stable stochastic magnetic tunnel junctions and has not been documented in two-dimensional magnets. Our findings not only address the existing knowledge gap concerning the influence of tunneling currents in controlling the magnetism in two-dimensional magnets, but also unlock possibilities for energy-efficient probabilistic and neuromorphic computing.

Science & Technology - Other Topics↗

ytopt: Autotuning Scientific Applications for Energy Efficiency at Large Scales

As we enter the exascale computing era, efficiently utilizing power and optimizing the performance of scientific applications under power and energy constraints has become critical and challenging. We propose a low-overhead autotuning framework to autotune performance and energy for various hybrid MPI/OpenMP scientific applications at large scales and to explore the tradeoffs between application runtime and power/energy for energy efficient application execution, then use this framework to autotune four ECP proxy applications—XSBench, AMG, SWFFT, and SW4lite. Our approach uses Bayesian optimization with a Random Forest surrogate model to effectively search parameter spaces with up to 6 million different configurations on two large-scale HPC production systems, Theta at Argonne National Laboratory and Summit at Oak Ridge National Laboratory. The experimental results show that our autotuning framework at large scales has low overhead and achieves good scalability. Using the proposed autotuning framework to identify the best configurations, we achieve up to 91.59% performance improvement, up to 21.2% energy savings, and up to 37.84% EDP (energy delay product) improvement on up to 4096 nodes.

Autotuning↗

Framework for Modeling 3D-Printed Concrete Construction to Assess Energy Efficiency and Backup Power Trade-Offs in a Mixed-Use, New Construction Neighborhood Development

This paper presents a framework that expands the URBANopt(TM) modeling platform to include 3D-printed concrete wall assemblies and assess energy efficiency and backup power trade-offs in new housing developments. Applied to a planned mixed-use neighborhood in Oil City, Pennsylvania, the workflow integrates building energy and distributed energy resource (DER) modeling to evaluate envelope and equipment upgrades alongside DER operations. Results show that advanced 3D-printed envelopes combined with efficient systems and onsite photovoltaics (PV) and storage reduce energy use intensity and sustain critical loads during outages. The framework supports planning for emerging construction technologies by quantifying key trade-offs between energy efficiency and backup power performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harnessing Quantum Computing for Energy Materials: Opportunities and Challenges

Developing high-performance materials is critical for diverse energy applications to increase efficiency, improve sustainability and reduce costs. Classical computational methods have enabled important breakthroughs in energy materials development, but they face scaling and time-complexity limitations, particularly for high-dimensional or strongly correlated material systems. Quantum computing (QC) promises to offer a paradigm shift by exploiting quantum bits with their superposition and entanglement to address challenging problems intractable for classical approaches. This Perspective discusses the opportunities in leveraging QC to advance energy materials research and the challenges QC faces in solving complex and high-dimensional problems. We present cases on how QC, when combined with classical computing methods, can be used for the design and simulation of practical energy materials. We also outline the outlook for error-corrected, fault-tolerant QC capable of achieving predictive accuracy and quantum advantage for complex material systems.

Algorithms↗

Multiobjective Optimization of Low-Energy Trajectories Using Optimal Control on Dynamical Channels

We introduce a computational method to design efficient low-energy trajectories by extracting initial solutions from dynamical channels formed by invariant manifolds, and improving these solutions through variational optimal control. We consider trajectories connecting two unstable periodic orbits in the circular restricted 3-body problem (CR3BP). Our method leverages dynamical channels to generate a range of solutions, and approximates the areto front for impulse and time of flight through a multiobjective optimization of these solutions based on primer vector theory. We demonstrate the application of our method to a libration orbit transfer in the Earth-Moon system.

trajectory design↗

Optoelectronic polymer memristors with dynamic control for power-efficient in-sensor edge computing

Abstract As the demand for edge platforms in artificial intelligence increases, including mobile devices and security applications, the surge in data influx into edge devices often triggers interference and suboptimal decision-making. There is a pressing need for solutions emphasizing low power consumption and cost-effectiveness. In-sensor computing systems employing memristors face challenges in optimizing energy efficiency and streamlining manufacturing due to the necessity for multiple physical processing components. Here, we introduce low-power organic optoelectronic memristors with synergistic optical and mV-level electrical tunable operation for a dynamic “control-on-demand” architecture. Integrating signal sensing, featuring, and processing within the same memristors enables the realization of each in-sensor analogue reservoir computing module, and minimizes circuit integration complexity. The system achieves 97.15% fingerprint recognition accuracy while maintaining a minimal reservoir size and ultra-low energy consumption. Furthermore, we leverage wafer-scale solution techniques and flexible substrates for optimal memristor fabrication. By centralizing core functionalities on the same in-sensor platform, we propose a resilient and adaptable framework for energy-efficient and economical edge computing.

Optics↗

Modeling and comparative assessment of municipal solid waste gasification for energy production

Highlights: • Study developed a methodology for the evaluation of gasification for MSW treatment. • Study was conducted comparatively for USA, UAE, and Thailand. • Study applies a thermodynamic model (Gibbs free energy minimization) using the Gasify software. • The energy efficiency of the process and the compatibility with different waste streams was studied. - Abstract: Gasification is the thermochemical conversion of organic feedstocks mainly into combustible syngas (CO and H{sub 2}) along with other constituents. It has been widely used to convert coal into gaseous energy carriers but only has been recently looked at as a process for producing energy from biomass. This study explores the potential of gasification for energy production and treatment of municipal solid waste (MSW). It relies on adapting the theory governing the chemistry and kinetics of the gasification process to the use of MSW as a feedstock to the process. It also relies on an equilibrium kinetics and thermodynamics solver tool (Gasify®) in the process of modeling gasification of MSW. The effect of process temperature variation on gasifying MSW was explored and the results were compared to incineration as an alternative to gasification of MSW. Also, the assessment was performed comparatively for gasification of MSW in the United Arab Emirates, USA, and Thailand, presenting a spectrum of socioeconomic settings with varying MSW compositions in order to explore the effect of MSW composition variance on the products of gasification. All in all, this study provides an insight into the potential of gasification for the treatment of MSW and as a waste to energy alternative to incineration.

09 BIOMASS FUELS↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Determination Quantitative Analysis

The U.S. Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The final analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1-2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE's final determination. However, out of the 109 addenda, 34 were preliminarily determined to have a measureable and quantifiable impact. A suite of 240 computer energy simulations for building prototypes complying with ASHRAE 90.1-2007 was developed. These prototypes were then modified in accordance with these 34 addenda to create a second suite of corresponding building simulations reflecting the same buildings compliant with Standard 90.1-2010. The building simulations were conducted using the DOE EnergyPlus building simulation software. The resulting energy use from the complete suite of 480 simulation runs was then converted to energy use intensity (EUI, or energy use per unit floor area) metrics (Site EUI, Primary EUI, and energy cost intensity [ECI]) results for each simulation. For each edition of the standard, these EUIs were then aggregated to a national basis for each prototype using weighting factors based on construction floor area developed for each of the 15 U.S. climate zones using commercial construction data. When compared, the resulting weighted EUIs indicated that each of the 16 building prototypes used less energy under Standard 90.1-2010 than under Standard 90.1-2007 on a national basis when considering site energy, primary energy, or energy cost. The EUIs were also aggregated across building types to a national commercial building basis using the same weighting data. On a national basis, the final quantitative analysis estimated a floor-space-weighted national average reduction in new building energy consumption of 18.2 percent for source energy and 18.5 percent when considering site energy. An 18.2 percent savings in energy cost, based on national average commercial energy costs for electricity and natural gas, was also estimated.

03 NATURAL GAS↗

Effect of energy dependence of the density of states on pressure-dependent rate constants

The F E integral for the normalized Boltzmann-weighted number of unimolecular states above the threshold energy is the key quantity for computing the collision efficiency in the pressure-dependent unimolecular rate theory developed by Troe, who calls this the energy dependence factor of the density of states. By using the Whitten–Rabinovitch approximation and assuming that the Whitten–Rabinovitch a(E) function is independent of energy, F E can be approximated by an analytical formula; this approximate formula is widely used because of its convenience and computational efficiency. Here we test its validity by comparing the rate constants computed by using the approximate F E to the ones determined by using the numerically integrated F E . For small-sized molecules and for reactions with high threshold energies E 0 , the differences are negligible at all temperatures, but in other cases, the approximate formula tends to underestimate F E and thus overestimates the collision efficiency, and this leads to smaller pressure falloff. When a(E) at high energies differs appreciably from a(E 0 ), we find that the underestimation of pressure-dependent rate constants by using the approximate formula can be greater than a factor of 5 at high temperatures. The physical insight we draw from this study is that, for reactions with threshold energies below about 30 kcal mol -1 , the rate of collisional energy transfer can be appreciably slowed down by the increase in the density of states at higher energies, and this increases the falloff effect by which finite-pressure rate constants become lower than the high-pressure limit, especially at higher temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fighting Fire with Fire: Superlattice Cooling of Silicon Hotspots to Reduce Global Cooling Requirements

The running costs of data centers are dominated by the need to dissipate heat generated by thousands of server machines. Higher temperatures are undesirable as they lead to premature silicon wear-out; in fact, mean time to failure has been shown to decrease exponentially with temperature (Black's law). Although other server components also generate heat, microprocessors still dominate in most server configurations and are also the most vulnerable to wearout as the feature sizes shrink. Even as processor complexity and technology scaling have increased the average energy density inside a processor to maximally tolerable levels, modern microprocessors make extensive use of hardware structures such as the load-store queue and other CAM-based units, and the peak temperatures on chip can be much worse than even the average temperature of the chip. In recent studies, it has been shown that hot-spots inside a processor can generate {approx} 800W/cm{sup 2} heat flux whereas the average heat flux is only 10-50W/cm{sup 2}, and due to this disparity in heat generation, the temperature in hot spots may be up to 30 C more than average chip temperature. The key problem processor hot-spots create is that in order to prevent some critical hardware structures from wearing out faster, the air conditioners in a data center have to be provisioned for worst case requirements. Worse yet, air conditioner efficiencies decrease exponentially as the desired ambient temperature decreases relative to the air outside. As a result, the global cooling costs in data centers, which nearly equals the IT equipment power consumption, are directly correlated with the maximum hot spot temperatures of processors, and there is a distinct requirement for a cooling technique to mitigate hot-spots selectively so that the global air conditioners can operate at higher, more efficient, temperatures. We observe that localized cooling via superlattice microrefrigeration presents exactly this opportunity whereby hot-spots can be cooled selectively and allow global coolers to operate at much more efficient temperatures. Recent advances in processor cooling technologies have demonstrated that thermoelectric coolers (TEC), which use a Peltier effect to form heat pumps, can be used to reduce the temperature of hot spots. By applying a thermoelectric cooler between the heat spreader and the processor die and applying current selectively at the hot spots, heat from the hot-spots can be spread much more efficiently. The ability to implement such thermoelectric coolers on a real silicon device has been demonstrated recently, albeit for small prototype chips. The key question then, that needs to be answered before such thermoelectric coolers can be integrated in commodity server processors, is 'What is the potential for superlattice microrefrigeration to reduce global cooling costs in data centers?'. In order to answer this question, we present a comprehensive analysis of the impact of thermoelectric coolers on global cooling costs. Our thermal analysis covers all aspects of cooling a server in a data center, and integrates on-chip dynamic and leakage power sources with a detailed heat diffusion model of a processor (that models the silicon to the thermoelectric cooler to the heat spreader and the heat sink) and finally the computer room air conditioner (CRAC) efficiency, as shown in Figure 1. In Section II, we present the components of the system model.

99 GENERAL AND MISCELLANEOUS↗

An accurate and efficient computational protocol for obtaining the complete basis set limits of the binding energies of water clusters at the MP2 and CCSD(T) levels of theory: Application to (H₂O) m , m=2-6, 8, 11, 16 and 17

We report MP2 and CCSD(T) binding energies with basis sets up to pentuple zeta quality for the m = 2-6, 8 clusters. Or best CCSD(T)/CBS estimates are -4.99 kcal/mol (dimer), -15.77 kcal/mol (trimer), -27.39 kcal/mol (tetramer), -35.9 ± 0.3 kcal/mol (pentamer), -46.2 ± 0.3 kcal/mol (prism hexamer), -45.9 ± 0.3 kcal/mol (cage hexamer), -45.4 ± 0.3 kcal/mol (book hexamer), -44.3 ± 0.3 kcal/mol (ring hexamer), -73.0 ± 0.5 kcal/mol (D 2d octamer) and -72.9 ± 0.5 kcal/mol (S4 octamer). We have found that the percentage of both the uncorrected (dimer) and BSSE-corrected (dimer CP e ) binding energies recovered with respect to the CBS limit falls into a narrow range for each basis set for all clusters and in addition this range was found to decrease upon increasing the basis set. Relatively accurate estimates (within < 0.5%) of the CBS limits can be obtained when using the “ 2/3, 1/3” (for the AVDZ set) or the “½ , ½” (for the AVTZ, AVQZ and AV5Z sets) mixing ratio between dimer e and dimer CP e . Based on those findings we propose an accurate and efficient computational protocol that can be used to estimate accurate binding energies of clusters at the MP2 (for up to 100 molecules) and CCSD(T) (for up to 30 molecules) levels of theory. This work was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences. Pacific Northwest National Laboratory (PNNL) is a multi program national laboratory operated for DOE by Battelle. This research also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. AC02-05CH11231.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technology Integration to Gain Commercial Efficiency for the Urban Goods Delivery System, Meet Future Demand for City Passenger and Delivery Load/Unload Spaces, and Reduce Energy Consumption

This three-year project supported by the U.S. Department of Energy Vehicle Technologies Office has the potential to radically improve the urban freight system in ways that help both the public and private sectors. Working from 2018-2021, project researchers at the University of Washington’s Urban Freight Lab and collaborators at the Pacific Northwest National Laboratory have produced key data, tested technologies in complex urban settings, developed a prototype parking availability app, and helped close major knowledge gaps. All the fruits of this project can be harnessed to help cities better understand, support and actively manage truck load/unload operations and their urban freight transport infrastructure. Project learnings and tools can be used to help make goods delivery firms more efficient by reducing miles traveled and the time it takes to complete deliveries, benefitting businesses and residents who rely on the urban freight system for supplies of goods. And, ultimately, these project learnings and tools can be used to make cities more livable by minimizing wasted travel, which, in turn, contributes to reductions in fuel consumption and emissions. Cities today are challenged to effectively and efficiently manage their infrastructure to absorb the impacts of ever-increasing e-commerce-fueled delivery demand. All delivery trucks need to park somewhere to unload and load. Yet today’s delivery drivers have no visibility on available parking until they arrive at a site, which may be full. That means they can wind up cruising for parking, which wastes time and fuel and contributes to congestion. Once drivers do find parking, the faster they can unload at the spot, the faster they free up space for other drivers, helping others avoid circling for parking. This makes the parking space—and thus the greater load/unload network—more productive. To this end, the research team successfully met the project’s three goals, developing and piloting strategies and technologies to: 1. Reduce parking-seeking behavior in the study area by 20%; 2. Reduce parcel truck dwell time (the time a truck spends in a spot to load/unload) in the study area by 30%; 3. Increase curb space, alley space and private loading bay occupancy rates in the study area. The research team met these goals by creating and piloting on Seattle streets OpenPark, a first-of-its-kind real-time and forecasting curb parking app customized for commercial delivery drivers—giving drivers the “missing link” in their commonly used routing tools that tell them how best to get to delivery locations, but not what parking is available to use when they get there. Installing in-ground sensors on commercial vehicle load zones (CVLZs) and passenger load zones (PLZs) in the 10-block study area in Seattle’s downtown neighbourhood of Belltown let researchers glean real-time curb parking data. The research team also met project goals by piloting three parcel lockers in public and private spaces open to any delivery carrier, creating a consolidated delivery hub that lets drivers complete deliveries faster and spend less time parked. Researchers collected and analysed data to produce the first empirical, robust, statistically significant results as to the impact of the lockers, and app, on on-the-ground operations. In addition to collecting and analyzing sensor and other real-time and historical data, researchers rode along with delivery drivers to confirm real-world routing and parking behavior. Researchers also surveyed building managers on their private loading bay operations to understand how to boost usage.

97 MATHEMATICS AND COMPUTING↗