Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enthalpy method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The use of electrical discharge for ignition and control of combustion of solid propellants

As the first step of the study of the combustion control of solid propellants by electrical discharges, the effects of an arc discharge, which flows along the burning surface, on the burning rate and on the increase of enthalpy of the combustion product were investigated. For specially devised composite propellants, which are composed of Al and Teflon powders, it was shown that the combination can be controlled by an arc discharge; the combustion continues when the arc discharge is applied and is interrupted when the arc discharge breaks. In the present investigation, it was also shown that an arc discharge coupled with a high-frequency electrical discharge has potential as an effective ignition method for solid propellants. For the application of this type of combustion control to an ignitor for a solid propellant rocket motor or to a control rocket motor, this method lacks flexibility in the configuration scale and needs relatively high electric power at the present stage.

Tachibana, Takeshi↗

Electron heating and the potential jump across fast mode shocks

Two different methods were applied to determine the cross-shock potential jump in the de Hoffmann-Teller reference frame, using a data set that represented 66 crossings of the terrestrial bow shock and 14 interplanetary shocks observed by various ISEE spacecraft, and one crossing each of the Jovian bow shock and the Uranian bow shock made by the Voyager spacecraft. Results for estimates of the electrostatic potential based on an estimate of the jump in electron enthalpy correlated well with estimates based on Liouville's theorem, although the Liouville-determined values were systematically the higher of the two, suggesting that significant irreversible processes contribute to the shape of the downstream distribution. The potential jump corresponds to approximately 12-15 percent of the incident ion ram kinetic energy, and was found not to be controlled by the Mach number, plasma beta, shock geometry, or electron to ion temperature ratios.

Schwartz, Steven J.↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Numerical implementation of the MOOSE subchannel module (SCM) algorithm

The subchannel module of moose (SCM), previously referred to as Pronghorn-SC, is a subchannel code designed to resolve single-phase flow fields and calculate the relevant flow variables, in nuclear reactor fuel-pin assemblies. The assemblies it models are: water-cooled, with bare fuel-pins in a square ducted, quadrilateral lattice and liquid-metal/water-cooled, with bare/wire-wrapped fuel pins in a hexagonal ducted, triangular lattice. Previous publications have presented the development, validation and verification of SCM. This work presents an comparative overview of the different solvers implemented within SCM. This includes the solver algorithm description, and a performance comparison. The two test cases chosen to demonstrate the solver performance were taken from the PSBT enthalpy mixing benchmark and the ORNL-19 pin benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Heterostructural Alloy Phase Diagram for (Cd 1-x Zn x ) 3 As 2

Alloying the topological semimetal Cd 3 As 2 with Zn 3 As 2 provides a potential route for controlling the electronic properties. We predict the alloy phase diagram from first-principles calculations, considering that both end members have a crystal structure derived from the antifluorite lattice, but with different arrangements of the unoccupied cation sites. To overcome the limitations of the regular solution approximation and to include short-range order effects, we perform Monte Carlo simulations, parameterize the temperature dependence of the mixing enthalpy ΔH m , and perform thermodynamic integration of the free energy. The resulting phase diagram exhibits features that are unique to heterostructural alloy systems and provides computational predictions of solubility limits and composition ranges that are stable against spinodal decomposition.

36 MATERIALS SCIENCE↗

Computing the solubility of argon and xenon in molten sodium chloride and potassium chloride salts

Molten salt reactors (MSRs) offer significant advancements in nuclear reactor safety and efficiency by operating at higher temperatures and lower pressures compared to traditional reactors. A critical aspect of MSR operation involves understanding the solubility of fission byproducts, particularly noble gases, in the molten salts used. This study employs molecular dynamics (MD) simulations to compute Henry’s law constants and enthalpies of solvation for argon and xenon in molten sodium chloride (NaCl) and potassium chloride (KCl). We developed a new pairwise potential for the noble gas and salt interactions based on first principles calculations. We then used this potential to calculate Henry’s law constants of the two gases in the molten salts, which were modeled using both a rigid ion model (RIM) and a polarizable ion model (PIM). The solubility calculations, performed using the Widom insertion method, show qualitative agreement with limited experimental data, highlighting the temperature dependence and greater solubility of both gases in KCl compared to NaCl. Additionally, free volume analysis elucidated the role of available space within the molten salts in governing solubility trends. Our findings suggest that PIM trajectories provide more reliable predictions for noble gas solubility than RIM due to their accurate density representation. Furthermore, these results enhance understanding of gas solubility in MSR environments, and the methods can be readily extended to other systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mach 4 and Mach 8 axisymmetric nozzles for a high-enthalpy shock tunnel

The performance of two axisymmetric nozzles which were designed to produce uniform, parallel flow with nominal Mach numbers of 4 and 8 is examined. A free-piston-driven shock tube was used to supply the nozzle with high-temperature, high-pressure test gas. The inviscid design procedure treated the nozzle expansion in two stages. Close to the nozzle throat, the nozzle wall was specified as conical and the gas flow was treated as a quasi-one-dimensional chemically-reacting flow. At the end of the conical expansion, the gas was assumed to be calorically perfect, and a contoured wall was designed (using method of characteristics) to convert the source flow into a uniform and parallel flow at the end of the nozzle. Performance was assessed by measuring Pitot pressures across the exit plane of the nozzles and, over the range of operating conditions examined, the nozzles produced satisfactory test flows. However, there were flow disturbances in the Mach 8 nozzle flow that persisted for significant times after flow initiation.

Jacobs, P. A.↗

An Approximate Ablative Thermal Protection System Sizing Tool for Entry System Design

A computer tool to perform entry vehicle ablative thermal protection systems sizing has been developed. Two options for calculating the thermal response are incorporated into the tool. One, an industry-standard, high-fidelity ablation and thermal response program was integrated into the tool, making use of simulated trajectory data to calculate its boundary conditions at the ablating surface. Second, an approximate method that uses heat of ablation data to estimate heat shield recession during entry has been coupled to a one-dimensional finite-difference calculation that calculates the in-depth thermal response. The in-depth solution accounts for material decomposition, but does not account for pyrolysis gas energy absorption through the material. Engineering correlations are used to estimate stagnation point convective and radiative heating as a function of time. The sizing tool calculates recovery enthalpy, wall enthalpy, surface pressure, and heat transfer coefficient. Verification of this tool is performed by comparison to past thermal protection system sizings for the Mars Pathfinder and Stardust entry systems and calculations are performed for an Apollo capsule entering the atmosphere at lunar and Mars return speeds.

Dec, John A.↗

An Approximate Ablative Thermal Protection System Sizing Tool for Entry System Design

A computer tool to perform entry vehicle ablative thermal protection systems sizing has been developed. Two options for calculating the thermal response are incorporated into the tool. One, an industry-standard, high-fidelity ablation and thermal response program was integrated into the tool, making use of simulated trajectory data to calculate its boundary conditions at the ablating surface. Second, an approximate method that uses heat of ablation data to estimate heat shield recession during entry has been coupled to a one-dimensional finite-difference calculation that calculates the in-depth thermal response. The in-depth solution accounts for material decomposition, but does not account for pyrolysis gas energy absorption through the material. Engineering correlations are used to estimate stagnation point convective and radiative heating as a function of time. The sizing tool calculates recovery enthalpy, wall enthalpy, surface pressure, and heat transfer coefficient. Verification of this tool is performed by comparison to past thermal protection system sizings for the Mars Pathfinder and Stardust entry systems and calculations are performed for an Apollo capsule entering the atmosphere at lunar and Mars return speeds.

Dec, John A.↗

Gas-phase ion-molecule interactions in a collision reaction cell with triple quadrupole-inductively coupled plasma mass spectrometry: Investigations with N 2 O as the reaction gas

Nitrous oxide (N 2 O) was used as a reaction gas to investigate the gas phase ion-molecule interactions using the Agilent 8900 QQQ-ICP-MS. A multi-element standard containing 45 elements with masses ranging from 9 to 208 u was measured in the presence and absence of N 2 O. The main product ion species observed were oxides and nitrides. Comparison of the N 2 O reaction results with similar measurements conducted with O 2 revealed that N 2 O was more effective at forming oxides in general: the elements Cd and Pb were shown to produce oxides with N 2 O where the reaction did not occur with O 2 . Nitrous oxide was also shown to produce a significant amount of nitride species in a few cases. The general reactivity was shown to be consistent with density functional theory (DFT)-predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels at least 1% of the unreacted ion. Our results show that reaction enthalpy is a reasonable predictor of reactivity with N2O on the timescales of the interactions in non-thermal ICP-MS/MS systems. Our work demonstrates the utility of two relatively new platforms (commercial elemental ICP-MS/MS and EMSL Arrows interface to the NWChem program suite), which allows for the study of a large number of elements within a short period. While DFT with the basis sets utilized here is not the most accurate computational method, it is also not computationally expensive and is shown to be suitable for predicting gas phase reactivity in the QQQ-ICP-MS for the majority of ions studied. Here, the ease and rapidity of data collection and DFT calculations has the potential to be very impactful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

Validation of Octane Hyperboosting Phenomenon in Prenol and Structurally Related Olefinic Alcohols

Hyperboosting is a recently discovered phenomenon in which the research octane number (RON) of a blend is higher than both the neat blendstock and the neat fuel it was blended into. RON is a measure of a fuel's resistance to knock, and knock is a cause of engine inefficiency. Blends which exhibit hyperboosting are blends in which an overall improvement in engine efficiency may be expected. The first discovery of hyperboosting came from blending experiments in which prenol was blended into several different base fuels. Here, ignition delay time (IDT) measurements taken using a commercially available constant volume combustion chamber called the Advanced Fuel Ignition Delay Analyzer (AFIDA) are presented. The data show that some prenol blends have longer IDTs (lower reactivity) than either neat prenol or the base fuel, providing further evidence of hyperboosting. Additionally, more blending data is presented in which the base fuel is varied, which allows for a better understanding of hyperboosting sensitivity to chemical classes. The data indicate that aromatics may inhibit, and branched alkanes may enhance the magnitude of hyperboosting observed. Enthalpy of vaporization estimates are also given for several molecules which are blended into a 4-component surrogate. These estimates are derived from Equation of State simulations and reveal that there is no observable correlation between hyperboosting and enthalpy of vaporization. Blending data for molecules which share structural similarities with prenol are also presented. Structure property relationships are suggested, in which the double bond motif of prenol seems to play an important role in hyperboosting. This may help to understand hyperboosting and its underlying mechanism. Lastly, blending curves of surrogate blends with prenol experienced hyperboosting under lean (Homogeneous Charged Compression Ignition-HCCI) operating conditions, which validates that hyperboosting is not an artifact of the octane test methods, but inherent to the properties of prenol.

ADVANCED PROPULSION SYSTEMS↗

Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings

Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.

25 ENERGY STORAGE↗

Simulating AOTV heating environment in an arc jet

The application of arc-jet facilities to the simulation of the combined radiative and convective heating environments calculated for AOTV return missions is presented. The AOTV mission requirement and design configuration determine the magnitude of the radiative and convective heating rates. This paper considers methods for obtaining radiation from the high temperature plasma in arc-jet flows. A computer code that predicts arc-heater performance was used to determine the effect of gas mixtures on arc-heater performance, with the intent of increasing the gas temperature and resultant radiative emission. Numerical radiation solutions were compared with direct measurements of the radiative intensity from the gas cap. Convective heating measurements were made as well. The arc-jet was operated at AOTV enthalpy and pressure levels for these measurements to assess the simulation capabilities for AOTV material development/testing. A parametric study is presented that defines the capability of the Interaction Heating Facility arc jet at Ames to simulate both the radiative and the convective heating for current AOTV configurations.

Balboni, J.↗

A General Method for Automatic Computation of Equilibrium Compositions and Theoretical Rocket Performance of Propellants

A general computer program for chemical equilibrium and rocket performance calculations was written for the IBM 650 computer with 2000 words of drum storage, 60 words of high-speed core storage, indexing registers, and floating point attachments. The program is capable of carrying out combustion and isentropic expansion calculations on a chemical system that may include as many as 10 different chemical elements, 30 reaction products, and 25 pressure ratios. In addition to the equilibrium composition, temperature, and pressure, the program calculates specific impulse, specific impulse in vacuum, characteristic velocity, thrust coefficient, area ratio, molecular weight, Mach number, specific heat, isentropic exponent, enthalpy, entropy, and several thermodynamic first derivatives.

Gordon, Sanford↗

Multi-wavelength Observations and Modelling of a Solar Flare

Aims: The aim of this work is to investigate the dynamic behavior of a C-class solar flare through the evolution of temperature, emission measure, energy loss and velocity. In particular, the variation of these properties with time are studied using multi-wavelength observations in combination with a recently developed 0-D hydrodynamic model. Methods: The temperature and emission measure evolution were studied using several instruments covering a wide range of temperatures - the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI, >5 MK), GOES-12 (5- 30 MK), the Transition Region and Coronal Explorer (TRACE 171 A, 1 MK) and the Coronal Diagnostic Spectrometer (CDS, 0.03-8 MK). The temperature and emission measure were analysed through the systematic cooling of flare plasma through the response functions of these instruments. These parameters were then investigated using the Enthalpy Based Thermal Evolution of Loops model (EBTEL). The Doppler shifts at both flare footpoints were analysed using five emission lines seen by CDS. Results: The flare began with clear evidence for pre-flare heating. Upflows of approx.90 km/s and low level emission, both observed in Fe XIX before the main impulsive phase were explained by pre-flare gentle chromospheric evaporation. During the main impulsive phase, the flare plasma was heated to a temperature of >13 MK in approximately 10 minutes. Explosive chromospheric evaporation was observed, driving upflows of approx.80 km/s in Fe XIX and simultaneous downflows of approx.20 km/s in He I and O v. At the peak of the Rare, conduction modelled by EBTEL was found to be the dominant loss mechanism, working efficiently to both lower the temperatures and drive gentle chromospheric evaporation. As the temperature fell below approx.8 MK, radiation became the dominant loss mechanism. During the final stages of the decay phase, downflowing plasma was observed at the footpoints in He I, O v and Mg x at velocities of up to approx.40 km/s, suggesting loop draining occurred. Conclusions. This is the first extensive study of the evolution of flare plasma using both spectroscopic and broad-band instruments in conjunction with a comprehensive hydrodynamic model. The flare began with pre-flare heating and then evolved following the predictions of the standard flare model. Detailed analysis of the plasma heating mechanisms was carried out and the heating function most consistent with observations was found to be Gaussian in shape. The simulations suggested that both direct heating and heating by a non-thermal beam played significant roles in this event.

Raftery, Claire L.↗

Extracting meaningful standard enthalpies and entropies of activation for surface reactions from kinetic rates

While analyses based on the Arrhenius kinetic model have been successfully applied since its introduction, the Arrhenius model neglects to describe pre-exponential factor in a scientifically meaningful fashion. Since the 1930s, transition-state theory (TST), has met with success in interpreting the pre-exponential factor’s value, allowing a standard entropy of activation to be estimated. However, analyses based on TST’s assumptions have been applied inconsistently in the literature, particularly in corrosion science, leading to difficulty in comparison of standard entropy of activations from different studies. In this work, the foundational principles of TST and standard states are discussed and a standard method to apply TST in analyzing rates of surface reactions is recommended. When full details are not available, reacting species’ concentrations should be normalized to the concentration of active surface sites. For corrosion reactions, conversion relationships are given to convert from units of corrosion rate to surface reaction rate, consistent with TST. This method is dubbed a surface reactant equi-density approximation. Application of this standard to reported data results in adjustments of the standard entropy of activation between - 65 and +50 J/mol K and brings reported entropies into a narrower range of values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗