Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosive detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Hyperspectral vegetation identification at a legacy underground nuclear explosion test site

The detection, location, and identification of suspected underground nuclear explosions (UNEs) are global security priorities that rely on integrated analysis of multiple data modalities for uncertainty reduction in event analysis. Vegetation disturbances may provide complementary signatures that can confirm or build on the observables produced by prompt sensing techniques such as seismic or radionuclide monitoring networks. For instance, the emergence of non-native species in an area may be indicative of anthropogenic activity or changes in vegetation health may reflect changes in the site conditions resulting from an underground explosion. Previously, we collected high spatial resolution (10 cm) hyperspectral data from an unmanned aerial system at a legacy underground nuclear explosion test site and its surrounds. These data consist of visible and near-infrared wavebands over 4.3 km 2 of high desert terrain along with high spatial resolution (2.5 cm) RGB context imagery. In this work, we employ various spectral detection and classification algorithms to identify and map vegetation species in an area of interest containing the legacy test site. Here, we employed a frequentist framework for fusing multiple spectral detections across various reference spectra captured at different times and sampled from multiple locations. The spatial distribution of vegetation species is compared to the location of the underground nuclear explosion. We discover a difference in species abundance within a 130 m radius of the center of the test site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standoff detection of chemical plumes from high explosive open detonations using a swept-wavelength external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser (ECQCL) is used to perform standoff detection of combustion gases in a plume generated from an outdoor high-explosive (HE) open detonation. The swept-ECQCL system was located at a standoff distance of 830 m from a 41kg charge of LX-14(polymer-bonded high explosive) and was used to measure the infrared transmission/absorption through the post-detonation plume as it propagated through the beam path. The swept-ECQCL was operated continuously to record broadband absorption spectra at 200hz rate over a spectral range from 2050 to 2230 cm -1 (4.48 - 4.88 μm). Fitting of measured spectra was used to determine time-resolved column densities of CO, CO 2 , H 2 O, and N 2 O. Analysis of visible video imagery was used to provide timing correlations and to estimate plume dimensions, from which gas mixing ratios were estimated. Measured emission factors and modified combustion efficiency show good agreement with previously reported values.

47 OTHER INSTRUMENTATION↗

Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that were used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geologic Assessment of the Damage Zone from the Second Test at Source Physics Experiment-Nevada (SPE-N)

The National Center for Nuclear Security (NCNS), established by the U.S. Department of Energy, National Nuclear Security Administration, is conducting a series of explosive tests at the Nevada National Security Site (NNSS; formerly the Nevada Test Site) that are designed to increase the understanding of certain basic physical phenomena associated with underground explosions. These tests will aid in developing technologies that might be used to detect underground nuclear explosions in support of verification activities for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The initial NCNS project is a series of explosive tests, known collectively as the Source Physics Experiment at the NNSS (SPE-N), being conducted in granitic rocks at the Climax stock in northern Yucca Flat. The SPE-N test series is designed to study the generation and propagation of seismic waves. The data will be used to improve the predictive capability of calculational models for detecting and characterizing underground explosions. The first SPE-N test (SPE-N-1) was a “calibration” shot conducted in May 2011, using 100 kilograms (kg) of explosives at the depth of 54.9 meters (m) (180 feet [ft]) in the U-15n source hole. SPE-N-2 was conducted in October 2011, using 1,000 kg of explosives at the depth of 45.7 m (150 ft) in the same source hole. Following the SPE-N-2 test, the core hole U-15n#10 was drilled at an angle from the surface to intercept the SPE-N-2 shot point location to obtain information necessary to characterize the damage zone. The desire was to determine the position of the damage zone near the shot point, at least on the northeast side, where the core hole penetrated it. The three-dimensional shape and symmetry of the damage zone are unknown at this time. Rather than spherical in shape, the dimensions of the damage zone could be influenced by the natural fracture sets in the vicinity. Geologic characterization of the borehole included geophysical logging, a directional survey, and geologic description of the core to document visual evidence of damage. Selected core samples were provided to Sandia National Laboratories (SNL) for laboratory tests (to be reported by SNL). A significant natural fault zone was encountered in the U-15n#10 angle core hole between the drilled depths of 149 and 155 ft (straight-line distance or range station [RS] from the shot point of 7.5 to 5.7 m). However, several of the fractures observed in the U-15n#10 hole are interpreted as having been caused by the explosion. These fractures are characterized by a “fresh,” mechanically broken look, with uncoated and very irregular surfaces. They tend to terminate against natural fractures and have orientations that differ from the previously defined natural fracture sets. The most distant fracture from the shot point that could be interpreted as having been caused by the explosion was seen at approximately RS 10.0 m. No other possibly explosion-induced fractures are apparent above the fault, but are common starting at RS 5.4 m, which is below the fault. It is unknown how the fault zone might have affected the propagation of seismic waves or how the materials in the fault zone (altered granite, breccia, gouge) were affected by the explosion. From RS 3.3 m to the end of the recovered core at RS 1.6 m, some of the core samples are softer and lighter in color, but do not appear to be weathered. It is thought this could be indicative of the presence of distributed microfracturing.

58 GEOSCIENCES↗

In the nuclear explosion monitoring context, what is an anomaly?

Abstract In the early years of nuclear explosion monitoring, experts used downwind detections with meaningful ratios of radioactive species to identify an explosion. Today’s reality is sparse networks of radionuclide monitoring stations looking for weak signals. Analysts need to discriminate between industrial background radioactivity and nuclear explosion signals, even using the detection of one isotope. Aerosol and xenon measurements potentially related to nuclear tests in 2006 and 2013 announced by the Democratic People’s Republic of Korea and from worldwide civilian background radioactivity are considered when defining radionuclide detection anomalies to objectively guide the use of limited analyst resources and reduce the possibility of not detecting nuclear explosions.

Miley, Harry S.↗

Towards maintaining canine training aid integrity: Effects of environmental factors and operational use on the triacetone triperoxide polymer odor capture‐and‐release system

Abstract There are many factors that may affect the longevity of or guide the use of canine training aids. Literature to date has mainly focused on identifying the headspace volatiles associated with training aids or odors and only minimal research exists into how different variables may alter those volatiles. The current study examines several factors affecting canine training aids: humidity, air flow, transportation, and operational deployment, using the triacetone triperoxide polymer odor capture‐and‐release canine training aid (TATP POCR) as the target. The TATP POCR is an absorption‐based canine training aid developed to be used to safely train canines to detect the odor of the explosive TATP in operational settings. Comparisons of the TATP POCR to neat TATP are made throughout the manuscript. First, humidity increased the background components of the POCR matrix, as well as the amount of TATP recovered was above the POCR. Humidity thus affected the amount of TATP detected but did not prevent detection. Second, air flow lessened the lifetime of the TATP POCR. Third, the practice of using primary and secondary containment successfully prevented contamination, cross‐contamination, and significant target loss, thereby maintaining kit integrity. Finally, the absorption of background odors from training environments was not observed. TATP headspace concentrations between a Deployed and Control POCR kit were not significantly different at time 0 (i.e., upon opening), which suggests that the operational use does not affect the function of the TATP POCR system. This information provides pivotal evidence for explosives detection canine handlers or trainers who utilize the TATP POCR.

Legal Medicine↗

Detection of Inorganic Salt-Based Homemade Explosives (HME) by Atmospheric Flow Tube–Mass Spectrometry

Using a commercial mass spectrometer interfaced with an atmospheric flow tube (AFT) allowed detection of a variety of inorganic compounds used as oxidizers in homemade explosives at picogram levels. The AFT provides reaction times between 3-5 seconds with flows of 6 L/min, enabling detection levels, after thermal desorption, similar to those previously demonstrated for RDX vapors in the low parts-per-quadrillion range. The thermal desorption of chlorate and perchlorate salts resulted in the production of the corresponding anions which have higher electron affinities than the nitrate reactant ions. A dielectric barrier discharge, used as the ionization source, produced the nitrate reactant ions. In some instances, the molecular salt formed adducts with the nitrate, chlorate, and/or perchlorate anions, giving insight into the original identity of the salt cation. Urea nitrate, guanidine nitrate, and potassium nitrate were also detected as adducts with the nitrate reactant ion. Direct room-temperature vapor detection of urea nitrate and hydrogen peroxide, which have relatively high vapor pressures compared to the other salts in this study, is also demonstrated. Room-temperature vapor detection of chlorate and perchlorate salts is possible by the addition of a dilute acid which converts the salt into a more volatile acidic form. A discussion of the instrumentation, methods used, and the ionization chemistry is provided.

chlorate, perchlorate, nitrate, detection, hydroge↗

Differential Seismic Phase Detection Probability as a Potential Discriminant of Explosions and Earthquakes

Deep learning models trained to estimate the probability of seismic P and S phases are rapidly expanding the scale of local event detections. Here, we evaluate the potential for deep learning model output phase detection probabilities to contribute to event‐type classification, particularly discrimination of single‐fired borehole explosions and earthquakes at local distances (<300 km). Motivated by the empirical success of P/S amplitude ratios, we consider the difference between P and S pick probability output from previously developed phase detection models, P prob −S prob ⁠, as a discriminant. Test data include M L ∼1–4 earthquakes and explosions observed by common seismographs in ten geologically diverse localities. Depending on the picking model and training data, binary classification using P prob −S prob with at least three stations can achieve approximately equivalent classification accuracy as P/S amplitude ratios without requiring any customization. Joint classification with P/S and P prob −S prob improves accuracy for most quality control scenarios. Pick probabilities are an efficient attribute to consider in explosion discrimination because they can be automated byproducts of event detection. They avoid the binary choice of picking or not picking weakly visible S waves common to explosions.

Duan, Chenglong [Rice Univ., Houston, TX (United S↗

Molecular Simulations of Adsorption and Diffusion of RDX in IRMOF-1

In order to test the feasibility of using metal-organic frameworks (MOFs) to pre-concentrate explosive molecules for detection, molecular simulations of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) within IRMOF-1 were performed. Grand canonical Monte Carlo (GCMC) simulations were used to generate adsorption isotherms for pure RDX, RDX in dry air, and RDX in wet air. In addition to the isotherms, the GCMC simulations provide adsorption energies and density distributions of the adsorbates within the MOF. Molecular dynamics simulations calculate diffusivities and provide a detailed understanding of the change in conformation of the RDX molecule upon adsorption. The presence of dry air has little influence on the amount of RDX that adsorbs. The presence of wet air increases the amount of RDX that adsorbs due to favorable interactions between RDX and water. We found a Henry's law constant of 21.2 mol/kg/bar for both pure RDX and RDX in dry air. The RDX adsorption sites are located (i) in big cages, (ii) near a vertex, and (iii) between benzene rings. The energy of adsorption of RDX at infinite dilution was found to be - 9.2 kcal/mol. The distributions of bond lengths, bond angles and torsion angles in RDX are uniformly slightly broader in the gas phase than in the adsorbed phase, but not markedly so. The self-diffusivity of RDX in IRMOF-1 is a strong function of temperature, with an activation energy of 6.0 kcal/mol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Worldwide measurements of radioxenon background near isotope production facilities, a nuclear power plant and at remote sites: the ‘‘EU/JA-II’’ Project

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) specifies that radioxenon measurements should be performed at 40 or more stations worldwide within the International Monitoring System (IMS). Measuring radioxenon is one of the principle techniques to detect underground nuclear explosions. Specifically, presence and ratios of different radioxenon isotopes allows determining whether a detection event under consideration originated from a nuclear explosion or a civilian source. However, radioxenon monitoring on a global scale is a novel technology and the global civil background must be characterized sufficiently. This paper lays out a study, based on several unique measurement campaigns, of the worldwide concentrations and sources of verification relevant xenon isotopes. It complements the experience already gathered with radioxenon measurements within the CTBT IMS programme and focuses on locations in Belgium, Germany, Kuwait, Thailand and South Africa where very little information was available on ambient xenon levels or interesting sites offered opportunities to learn more about emissions from known sources. The findings corroborate the hypothesis that a few major radioxenon sources contribute in great part to the global radioxenon background. Additionally, the existence of independent sources of 131mXe (the daughter of 131I) has been demonstrated, which has some potential to bias the isotopic signature of signals from nuclear explosions.

Saey, P. R.J.↗

Radionuclide measurements of the international monitoring system

The International Monitoring System (IMS) is a unique global network of sensors, tuned to measure various phenomenology, with the common goal of detecting a nuclear explosion anywhere in the world. One component of this network collects measurements of radioactive particulates and gases (collectively known as radionuclides) present in the atmosphere; through this, compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) can be verified. The radionuclide sub-network consists of 120 sensors across 80 locations, supported by 16 measurement laboratories. All radionuclide stations make use of a form of γ-ray spectroscopy to measure radionuclides from samples; this remains largely unchanged since the network was first established 25 years ago. Advances in sampling and spectroscopy systems can yield improvements to the sensitivity of the network to detect a nuclear explosion. This paper summarises the status of the IMS radionuclide network, the current suite of technology used and reviews new technology that could enhance future iterations, potentially improving the verification power of the IMS.

Goodwin, Matthew A.↗

Experimental Detection of the Signs of a Coulomb Explosion in Micropinch Plasma

A flow of ions with energies of about 3 MeV propagating in the direction perpendicular to the symmetry axis of discharge has been detected in high-current low inductance vacuum spark. Estimations show that the measured ion energies quite well correspond to the value that can be achieved as a result of “Coulomb explosion” of the waist of a plasma channel of discharge current at the stage preceding its radiation compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast time variations of supernova neutrino fluxes and their detectability

In the delayed explosion scenario of core-collapse supernovae, the accretion phase shows pronounced convective overturns and a low-multipole hydrodynamic instability, the standing accretion shock instability. These effects imprint detectable fast time variations on the emerging neutrino flux. Among existing detectors, IceCube is best suited to this task, providing an event rate of {approx}1000 ms{sup -1} during the accretion phase for a fiducial SN distance of 10 kpc, comparable to what could be achieved with a megaton water Cherenkov detector. If the standing accretion shock instability activity lasts for several hundred ms, a Fourier component with an amplitude of 1% of the average signal clearly sticks out from the shot noise. We analyze in detail the output of axially symmetric hydrodynamical simulations that predict much larger amplitudes up to frequencies of a few hundred Hz. If these models are roughly representative for realistic SNe, fast time variations of the neutrino signal are easily detectable in IceCube or future megaton-class instruments. We also discuss the information that could be deduced from such a measurement about the physics in the SN core and the explosion mechanism of the SN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol Sample Inhomogeneity with Debris from the Fukushima Daiichi Nuclear Accident

Radionuclide aerosol sampling is a vital component in the detection of nuclear explosions, nuclear accidents, and other radiation releases. This was proven by the detection and tracking of emissions from the Fukushima Daiichi incident across the globe by IMS stations. Two separate aerosol samplers were operated in Richland, WA following the event and debris from the accident were measured at levels well above detection limits. While the atmospheric activity concentration of radionuclides generally compared well between the two stations, they did not agree within uncertainties. This paper includes a detailed study of the aerosol sample homogeneity of 134 Cs and 137 Cs, then relates it to the overall uncertainty of the original measurement. Our results show that sample inhomogeneity adds an additional 5–10% uncertainty to each aerosol measurement and that this uncertainty is in the same range as the discrepancies between the two aerosol sample measurements from Richland, WA.

Gomez, Reynaido↗

Geologic Assessment of the Damage Zone from the Second Test at Source Physics Experiment-Nevada (SPE-N)

The National Center for Nuclear Security, established by the U.S. Department of Energy, National Nuclear Security Administration (NNSA), is conducting a series of explosive tests at the Nevada National Security Site that are designed to increase the understanding of certain basic physical phenomena associated with underground explosions. These tests will aid in developing technologies that might be used to detect underground nuclear explosions in support of verification activities for the Comprehensive Nuclear-Test-Ban Treaty. The initial project is a series of explosive tests, known collectively as the Source Physics Experiment-Nevada (SPE-N), being conducted in granitic rocks. The SPE-N test series is designed to study the generation and propagation of seismic waves. The results will help advance the seismic monitoring capability of the United States by improving the predictive capability of physics-based modeling of explosive phenomena. The first SPE N (SPE-N-1) test was conducted in May 2011, using 100 kg of explosives at the depth of 54.9 m in the U 15n source hole. SPE-N-2 was conducted in October 2011, using 1,000 kg of explosives at the depth of 45.7 m in the same source hole. The SPE-N-3 test was conducted in the same source hole in July 2012, using the same amount and type of explosive as for SPE-N-2, and at the same depth as SPE-N-2, within the damage zone created by the SPE-N-2 explosion to investigate damage effects on seismic wave propagation. Following the SPE-N-2 shot and prior to the SPE-N-3 shot, the core hole U-15n#10 was drilled at an angle from the surface to intercept the SPE-N-2 shot point location to obtain information necessary to characterize the damage zone. The objective was to determine the position of the damage zone near the shot point, at least on the northeast, where the core hole penetrated it, and obtain information on the properties of the damaged medium. Geologic characterization of the post-SPE-N-2 core hole included geophysical logging, a directional survey, and geologic description of the core to document visual evidence of damage. Selected core samples were provided to Sandia National Laboratories (SNL) for measurement of physical and mechanical properties. A video was also run in the source hole after it was cleaned out. A significant natural fault zone was encountered in the angle core hole between 5.7 and 7.5 m from the shot point. However, several of the fractures observed in the core hole are interpreted as having been caused by the explosion. The fractures are characterized by a “fresh,” mechanically broken look, with uncoated and very irregular surfaces. They tend to terminate against natural fractures and have orientations that differ from the previously defined natural fracture sets; they are common starting at about 5.4 m from the shot point. Within about 3.3 m of the shot point to the end of the recovered core at 1.6 m from the shot point, some of the core samples are softer and lighter in color, but do not appear to be weathered. It is thought this could be indicative of the presence of distributed microfracturing.

SPE, Source Physics Experiment, geology↗

Nanoporous framework materials interfaced with mechanical sensors for highly-sensitive chemical sensing.

We will describe how novel nanoporous framework materials (NFM) such as metal-organic frameworks (MOFs) can be interfaced with common mechanical sensors, such as surface acoustic wave (SAW), microcantilever array, and quartz crystal microbalance (QCM) devices, and subsequently be used to provide selectivity and sensitivity to a broad range of analytes including explosives, nerve agents, and volatile organic compounds (VOCs). NFM are highly ordered, crystalline materials with considerable synthetic flexibility resulting from the presence of both organic and inorganic components within their structure. Chemical detection using micro-electro-mechanical-systems (MEMS) devices (i.e. SAWs, microcantilevers) requires the use of recognition layers to impart selectivity. Unlike traditional organic polymers, which are dense, the nanoporosity and ultrahigh surface areas of NFM allow for greater analyte uptake and enhance transport into and out of the sensing layer. This enhancement over traditional coatings leads to improved response times and greater sensitivity, while their ordered structure allows chemical tuning to impart selectivity. We describe here experiments and modeling aimed at creating NFM layers tailored to the detection of water vapor, explosives, CWMD, and volatile organic compound (VOCs), and their integration with the surfaces of MEMS devices. Molecular simulation shows that a high degree of chemical selectivity is feasible. For example, a suite of MOFs can select for strongly interacting organics (explosives, CWMD) vs. lighter volatile organics at trace concentrations. At higher gas pressures, the CWMD are deselected in favor of the volatile organics. We will also demonstrate the integration of various NFM on the surface of microcantiliver arrays, QCM crystals, and SAW devices, and describe new synthetic methods developed to improve the quality of NFM coatings. Finally, MOF-coated MEMS devices show how temperature changes can be tuned to improve response times, selectivity, and sensitivity.

36 MATERIALS SCIENCE↗

Application of Active Seismic and Electrical Methods to Detect and Characterize Subsurface Effects of an Underground Explosion

During the period of underground nuclear testing in the U.S., now ended for over 20 years, the focus of work was to conduct the test and analyze the data as quickly as possible; there was little concern about application of technologies that could be used to detect and characterize the location and depth of the explosion. Thus, there is little experience with applying geophysical methods in places where an underground nuclear explosion (UNE) has taken place. On the other hand, application of geophysical methods to the detection of shallow artifacts and water table depth is commonly applied in the environmental remediation and site characterization realm of commercial geophysical surveys. For nuclear nonproliferation treaty applications which may incorporate both shallow and deep geophysical probing methods (such as on-site inspection (OSI) under the Comprehensive Nuclear Test Ban Treaty [CTBT]), there thus remains a need to better understand detection capabilities of the deeper targets: anomalies related to an explosion cavity or rubble zone that may be located several hundred meters below the ground surface. The purpose of this Coordinated Inspection Technologies (CIT) project was to gain experience in applying active seismic methods and electrical methods at a site in Nevada where an underground nuclear test (UNE) had been conducted in the past to get a better understanding of the capabilities of these methods for detection and characterization of deep subsurface effects of the explosion.

58 GEOSCIENCES↗