Search NASA⌕ Search

SEARCH · Search NASA

Results for “FAR ULTRAVIOLET RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Accurate and quick calibration method for polarization-modulation spectroscopy using an ac-modulated polarizing undulator

An accurate calibration method in which an ac-modulated polarizing undulator is used for polarization modulation spectroscopy such as circular dichroism (CD) and linear dichroism (LD) has been proposed and successfully applied to vacuum ultraviolet (vuv) CD and LD spectra measured at beamline BL-5B in the electron storage ring, TERAS, at AIST. This calibration method employs an undulator-modulation spectroscopic method with a multireflection polarimeter, and it uses electronic and optical elements identical to those used for the CD and LD measurements. This method regards the polarimeter as a standard sample for the CD and LD measurements in the vuv region in which a standard sample has not yet been established. The calibration factors for the CD and LD spectra are obtained over a wide range of wavelengths, from 120 to 230 nm, at TERAS BL-5B. The calibrated CD and LD spectra measured at TERAS exhibit good agreement with the standard spectra for wavelengths greater than 170 nm; the mean differences between the standard and calibrated CD and LD spectra are approximately 7% and 4%, respectively. This method enables a remarkable reduction in the experimental time, from approximately 1 h to less than 10 min that is sufficient to observe the storage-ring current dependence of the calibration factors. This method can be applied to the calibration of vuv-CD spectra measured using a conventional photoelastic modulator and for performing an accurate analysis of protein secondary structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the O+allyl addition/elimination reaction pathways from the OCH{sub 2}CHCH{sub 2} radical intermediate

These experiments study the preparation of and product channels resulting from OCH{sub 2}CHCH{sub 2}, a key radical intermediate in the O+allyl bimolecular reaction. The data include velocity map imaging and molecular beam scattering results to probe the photolytic generation of the radical intermediate and the subsequent pathways by which the radicals access the energetically allowed product channels of the bimolecular reaction. The photodissociation of epichlorohydrin at 193.3 nm produces chlorine atoms and c-OCH{sub 2}CHCH{sub 2} radicals; these undergo a facile ring opening to the OCH{sub 2}CHCH{sub 2} radical intermediate. State-selective resonance-enhanced multiphoton ionization (REMPI) detection resolves the velocity distributions of ground and spin-orbit excited state chlorine independently, allowing for a more accurate determination of the internal energy distribution of the nascent radicals. We obtain good agreement detecting the velocity distributions of the Cl atoms with REMPI, vacuum ultraviolet (VUV) photoionization at 13.8 eV, and electron bombardment ionization; all show a bimodal distribution of recoil kinetic energies. The dominant high recoil kinetic energy feature peaks near 33 kcal/mol. To elucidate the product channels resulting from the OCH{sub 2}CHCH{sub 2} radical intermediate, the crossed laser-molecular beam experiment uses VUV photoionization and detects the velocity distribution of the possible products. The data identify the three dominant product channels as C{sub 3}H{sub 4}O (acrolein)+H, C{sub 2}H{sub 4}+HCO (formyl radical), and H{sub 2}CO (formaldehyde)+C{sub 2}H{sub 3}. A small signal from C{sub 2}H{sub 2}O (ketene) product is also detected. The measured velocity distributions and relative signal intensities at m/e=27, 28, and 29 at two photoionization energies show that the most exothermic product channel, C{sub 2}H{sub 5}+CO, does not contribute significantly to the product branching. The higher internal energy onset of the acrolein+H product channel is consistent with the relative barriers en route to each of these product channels calculated at the CCSD(T)/aug-cc-pVQZ level of theory, although a clean determination of the barrier energy to H+acrolein is precluded by the substantial partitioning into rotational energy during the photolytic production of the nascent radicals. We compare the measured branching fraction to the H+acrolein product channel with a statistical prediction based on the calculated transition states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tunable VUV photochemistry using Rydberg H-atom time-of-flight spectroscopy

In this article, we report an experimental method for studying tunable vacuum ultraviolet (VUV) photochemistry using the H-atom Rydberg tagging technique. In this method, two VUV laser light beams were generated using nonlinear four-wave mixing scheme in a single Kr gas cell: one VUV beam is fixed at the 121.6 nm wavelength to probe the H-atom product through the Lyman {alpha} transition, the other beam can be tunable for photodissociating molecules in the wavelength range {lambda}{sub VUV}=121-190 nm. Preliminary results on the H{sub 2}O photodissociation in the B-tilde state are reported here. These results suggest that the experimental method is a powerful tool for investigating photodissociation dynamics in the VUV region for molecules involving H-atom processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low temperature plasma diagnostics with tunable synchrotron vacuum ultraviolet photoionization mass spectrometry

Plasma-based technology is of great importance for a range of industrial applications. However, due to the complexity of gas-phase and surface chemical reactions, the underlying plasma chemistry is still poorly understood, leading to a growing demand for experimental setups on plasma diagnostics. In this paper, we report an apparatus that combines tunable synchrotron vacuum ultraviolet (VUV) photoionization with molecular-beam mass spectrometry for detecting ionic and neutral species formed in the processes of plasma discharge. The products including reactive intermediates such as enols can be identified unambiguously with the measurements of photoionization mass spectrometry (PIMS) and photoionization efficiency spectra. The tunable VUV PIMS has been proven as an ideal and sensitive tool for a comprehensive understanding of plasma chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution Rydberg tagging time-of-flight measurements of atomic photofragments by single-photon vacuum ultraviolet laser excitation

By coupling a comprehensive tunable vacuum ultraviolet (VUV) laser system to a velocity-mapped ion imaging apparatus, we show that high-resolution high-n Rydberg tagging time-of-flight (TOF) measurements of nascent atomic photofragments formed by laser photodissociation can be made using single-photon VUV laser photoexcitation. To illustrate this single-photon Rydberg tagging TOF method, we present here the results of the VUV laser high-n Rydberg tagging TOF measurements of O({sup 3}P{sub 2}) and S({sup 3}P{sub 2}) formed in the photodissociation of SO{sub 2} and CS{sub 2} at 193.3 and 202.3 nm, respectively. These results are compared to those obtained by employing the VUV laser photoionization time-sliced velocity-mapped ion imaging technique. The fact that the kinetic energy resolutions achieved in the VUV laser high-n Rydberg tagging TOF measurements of O and S atoms are found to be higher than those observed in the VUV laser photoionization, time-sliced velocity-mapped ion imaging studies show that the single-photon VUV laser high-n Rydberg tagging TOF method is useful and complementary to state-of-the-art time-sliced velocity-mapped ion imaging measurements of heavier atomic photofragments, such as O and S atoms. Furthermore, the general agreement observed between the VUV laser high-n Rydberg tagging TOF and velocity-mapped ion imaging experiments supports the conclusion that the lifetimes of the tagged Rydberg states of O and S atoms are sufficiently long to allow the reliable determination of state-resolved UV photodissociation cross sections of SO{sub 2} and CS{sub 2} by using the VUV laser high-n Rydberg tagging TOF method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism for low-etching resistance and surface roughness of ArF photoresist during plasma irradiation

ArF excimer laser lithography was introduced to fabricate nanometer-scale devices and uses chemically amplified photoresist polymers including photoacid generators (PAGs). Because plasma-etching processes cause serious problems related to the use of ArF photoresists, such as line-edge roughness and low etching selectivity, we have to understand the interaction between plasma and ArF photoresist polymers. Investigating the effects of surface temperature and the irradiation species from plasma, we have found that ion irradiation by itself did not drastically increase the roughness or etching rate of ArF photoresist films unless it was combined with ultraviolet/vacuum ultraviolet (UV/VUV) photon irradiation. The structures of ArF photoresist polymers were largely unchanged by ion irradiation alone but were destroyed by combinations of ion and UV/VUV-photon irradiation. Our results suggested that PAG-mediated deprotection induced by UV/VUV-photon irradiation was amplified at surface temperatures above 100 deg. C. The etching rate and surface roughness of plasma-etched ArF photoresists are affected by the irradiation species and surface temperature during plasma etching. UV/VUV-photon irradiation plays a particularly important role in the interaction between plasma and ArF photoresist polymers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra Slow Muon Project at J-PARC, MUSE

The muon science facility (MUSE), along with the neutron, hadron, and neutrino facilities, is one of the experimental areas of the J-PARC project, which was approved for construction at the Tokai JAEA site. The MUSE facility is located in the Materials and Life Science Facility (MLF), which is a building integrated to include both neutron and muon science programs. Construction of the MLF building was started in the beginning of 2004, and first muon beam is expected in the autumn of 2008.As a next step, we are planning to install, a Super Omega muon channel with a large acceptance of 400 msr, to extract the world strongest pulsed surface muon beam. Its goal is to extract 4x10{sup 8} surface muons/s for the generation of the intense ultra slow muons, utilizing laser resonant ionization of Mu by applying an intense pulsed VUV laser system. As maximum 1x10{sup 6} ultra slow muons/s will be expected, which will allow for the extension of {mu}SR into the field of thin film and surface science.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Impact of FUSE on our Understanding of Stellar Post-AGB Evolution

State-of-the-art non-LTE spectral analysis requires high-resolution and high-S/N observations of strategic metal lines in order to achieve reliable photospheric parameters like, e.g., effective temperature, surface gravity, and element abundances.Hot stars with effective temperatures higher than about 40 000 K exhibit their metal-line spectrum arising from highly ionized species predominantly in the (far) ultraviolet wavelength range.FUSE observations of hot, compact stars provided the necessary data. With these, it has been, e.g., possible to identify fluorine for the first time in observations of post-AGB stars. The evaluation of ionization equilibria of highly ionized neon, phosphorus, sulfur, and argon provides a new sensitive tool to determine effective temperatures of the hottest stars precisely. Moreover, abundance determinations have put constraints on stellar evolutionary models which, in turn, have improved greatly our picture of post-AGB evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the WHIM Gas Through Ne VIII Absorption

We report on the second ever {>=}3{sigma} detection of a Ne VIII intergalactic absorption system. The system is identified in the FUSE spectrum of 3C 263 at a redshift of z = 0.32566. The presence of intermediate ionization species such as O III, O IV, N IV and C IV at the same velocity as Ne VIII, confirms that the absorption system is tracing gas at multiple ionization conditions. Unlike the intermediate ions, we find that the Ne VIII in this absorber is inconsistent with having an origin in a cool photoionization gas phase. The more likely source is collisional ionization in a warm shock-heated phase, in which case the absorber is tracing the WHIM phase of the IGM. Further constraints from H I and O IV are needed to better understand the physical conditions in the warm collisionally ionized gas. The properties of this absorber bear resemblance to the previous detection of Ne VIII reported by Savage et al.(2005)

79 ASTRONOMY AND ASTROPHYSICS↗

Far-UV and UV Observations of the Low Redshift IGM

Most of the normal baryonic matter of the Universe at high and at low redshift is found in the space between galaxies. The study of this matter at low redshift has required access to ultraviolet spectroscopic space observatories. HST and FUSE have revealed that at low redshift {approx}30% of the baryons reside in the cool (T{approx}2x10{sup 4} K) photoionized IGM traced by the Lyman {alpha} forest while another {approx}10-20% might exist in the warm (T{approx}1-9x10{sup 5} K) portion of the warm-hot IGM. Evidence for the warm gas is provided by some of the O VI absorbers, the Ne VIII absorbers and very broad Lyman alpha absorbers. Understanding the physical conditions in these absorbers is important for reliably determining their baryonic content. The low z IGM is likely to play a crucial role in the evolution of the {approx}8% of the baryons found in galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

O VI Emission in Nuclear Region of NGC 1068

FUSE Spectra of the nuclear region of NGC 1068 find strong OVI emission consisting of a pair of narrow and broad components. There is a gradient in the velocity field for the narrow O VI component of {approx}200 kms{sup -1} from {approx}2'' southwest of the nucleus to {approx}4'' northeast. A similar pattern is also observed with the broad O VI component, with a gradient of {approx}3000 kms{sup -1}. These results are consistent with the HST/STIS findings and suggest a biconical structure in which the velocity field is mainly radial outflow.

79 ASTRONOMY AND ASTROPHYSICS↗

High-efficiency plasma display panel based on a high xenon mole fraction

The luminance efficiency of a plasma display panel is directly related to the vacuum-ultraviolet (VUV) light emitted from excited xenon atoms and molecules. The emission efficiency of 173 nm VUV light is measured in terms of the xenon mole fraction ({chi}) and is shown to become considerably enhanced at a high xenon mole fraction. For example, the emission efficiency at {chi}=0.35 under a pressure of 400 Torr is more than 2.5 times that at {chi}=0.1. The experimental data agree remarkably well with theoretical predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and test in liquid argon of the light readout system for the ArDM experiment

ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon (LAr) underground detector. The project relies on the read out of the VUV scintillation light and on the extraction of the electrons produced by ionization from the liquid into the gas phase of the detector. The light has to be converted with wavelength shifters such as TetraPhenyl Butadiene in order to be detected by photomultipliers with bialkali photocathodes. I describe the light readout system and the tests of the prototype with liquid argon in the full size detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Measurement of saturable absorption by intense vacuum ultraviolet free electron laser using fluorescent material

Advances in free electron lasers (FELs) which generate high energy photons are expected to open novel nonlinear optics in the x-ray and vacuum ultraviolet (VUV) regions. In this paper, we report a new method for performing VUV-FEL focusing experiments. A VUV-FEL was focused with Kirkpatrick-Baez optics on a multilayer target, which contains fused silica as a fluorescent material. By measuring the fluorescence, a 5.6x4.9 {mu}m{sup 2} focal spot was observed in situ. Fluorescence was used to measure the saturable absorption of VUV pulses in the tin layer. The transmission increases nonlinearly higher with increasing laser intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

System for time resolved spectral studies of pulsed atmospheric discharges in the visible to vacuum ultraviolet range

Vacuum ultraviolet (VUV) emission is believed to play a major role in the development of plasma streamers in pulsed atmospheric discharges, but detection of VUV light is difficult in pulsed experiments at atmospheric pressures. Since VUV light is absorbed in most standard optical materials as well, careful attention must be given to the selection of the lens and mirror optics used in these studies. Of highest interest is the VUV emission during the initial stage of pulsed atmospheric discharges, which has a typical duration in the nanosecond regime. An experiment was designed to study this fast initial stage of VUV emission coupled with fast optical imaging of streamer propagation, both with temporal resolution on the order of nanoseconds. A repetitive solid-state high voltage pulser was constructed which produces triggered flashover discharges with low jitter and consistent pulse amplitude. VUV emission is captured utilizing both photomultiplier and intensified charge-coupled device detectors during the fast stage of streamer propagation. These results are discussed in context with the streamer formation photographed in the visible wavelength regime with 3 ns exposure time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of multifilter based twin-prototypes for core electron temperature measurements in the TJ-II stellarator

The design and preliminary results from a prototype of a multifilter based electron temperature diagnostic for the TJ-II stellarator are presented. The diagnostic consists of four photodiodes with filters of different thicknesses to determine the electron temperature in a wide variety of plasma compositions, thanks to the set of six different signal-pairs ratios available. The impurity transport code IONEQ, the TJ-II soft x-ray tomography, and the VUV survey diagnostics give the necessary information to assess the proposed diagnostic reliability. In parallel, a vacuum-compatible multichannel electronic board has been designed for a future linear array to determine electron temperature profiles in high-density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗