Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Atomic clock based on transient coherent population trapping

We proposed a scheme to implement coherent population trapping (CPT) atomic clock based on the transient CPT phenomenon. We proved that the transient transmitted laser power in a typical {lambda} system near CPT resonance features as a damping oscillation. Also, the oscillating frequency is exactly equal to the frequency detuning from the atomic hyperfine splitting. Therefore, we can directly measure the frequency detuning and then compensated to the output frequency of microwave oscillator to get the standard frequency. By this method, we can further simplify the structure of CPT atomic clock, and make it easier to be digitized and miniaturized.

74 ATOMIC AND MOLECULAR PHYSICS↗

Data acquisition and editing for the celestial mechanics experiment

A radio tracking subsystem is reported in which the critical elements are the frequency standard and its distribution subsystem, as they ultimately limit the accuracy of both range and Doppler measurements. A rubidium vapor standard serves as the primary reference. After frequency multiplication to S-band and additional amplification, the carrier is transmitted to the spacecraft where a phase-locked receiver-transmitter system filters the signal, introduces a slight frequency shift, and retransmits it to the ground. Doppler is measured by comparing the received frequency with that being transmitted.

Martin, W. L.↗

Flexible bulb large storage box hydrogen maser

The principal limitation on the accuracy of the hydrogen maser as a primary frequency standard has been the irreproducibility of the frequency shift caused by collisions of the radiating atoms with the walls of the vessel containing them. The flexible bulb-large storage box hydrogen maser allows correction for this wall shift within a single device, sidestepping the reproducibility problem, and reducing the frequency error from the wall shift to the level imposed by the device's stability. The principles of the device are discussed including the flexible bulb technique and the complications caused by a multiple region storage bulb. The stability of the device is discussed including a comparison with an ordinary hydrogen maser. Data is presented from a working flexible bulb-large storage box hydrogen maser demonstrating the feasibility of the device and showing some of its operating characteristics. The flexibility of the device is demonstrated by showing how the device's added degrees of freedom allow measurement of parameters unmeasurable in an ordinary hydrogen maser.

Reinhardt, V.↗

Experimental optical fiber communications link

An optical fiber communications link 1.5 kilometers in length was installed between the Interim Frequency Standard Test Facility and the Timing and Frequency Systems Research Laboratory at JPL. It is being used to develop optical fiber technology for use in the DSN and particularly for precise time and frequency distribution.

Lutes, G. F.↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

The trapped ytterbium ion frequency standard under development at JPL is designed to supply ultra-stable reference signals to be used in spacecraft tests of general relativity and other science experiments. Only diode lasers meet the requirements of low power comsumption and small size for use aboard spacecraft, but diode lasers are not currently available at 369.4 nm wavelength. It is therefore necessary to employ frequency doubling methods to reach this frequency with diode lasers. Here we present the characteristics of the resonant cavity doubling system we have designed and preliminary UV conversion results.

ultra-stable↗

Relationships Between the Performance of Time/Frequency Standards and Navigation/Communication Systems

The relationship between system performance and clock or oscillator performance is discussed. Tradeoffs discussed include: short term stability versus bandwidth requirements; frequency accuracy versus signal acquisition time; flicker of frequency and drift versus resynchronization time; frequency precision versus communications traffic volume; spectral purity versus bit error rate, and frequency standard stability versus frequency selection and adjustability. The benefits and tradeoffs of using precise frequency and time signals are various levels of precision and accuracy are emphasized.

Hellwig, H.↗

A Precision, Low-Cost GPS-Based Transmitter Synchronization Scheme for Improved AM Reception

This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to {approx}1 part in 10{sup 9} or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station's carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station's audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) and often cause listeners to ldquotune outrdquo due to the low reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; hybrid digital (HD) signals will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1000-$2000), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long- term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific carrier frequency desired. The stability of the disciplining source, typically {approx}1 part in 10{sup 9} to 10{sup 11}, is thus transferred to the final AM transmitter carrier output frequency.

42 ENGINEERING↗

A Precision, Low-Cost GPS-Based Synchronization Scheme for Improved AM Reception.

This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to ~1 part in 109 or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station s carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station s audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) and often cause listeners to tune out due to the poor reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; HD will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1-2K), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long-term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific (AM broadcast) transmitter carrier frequency desired. The stability of the disciplining source, typically ~ 1 part in 109 to 1011, is thus transferred to the final AM transmitter carrier output frequency. Generally, an AM radio listener during the evening and nighttime hours, and to a lesser extent in the early morning, receives undesired skywave signals from several distant stations as well as the desired local (groundwave) signal. If all of these signals are within about 0.01-0.001 Hz of each other, any resulting carrier beats will be of such long periods that the beats will be effectively suppressed by the action of the receiver s AGC circuitry and thus be unnoticeable to the listener. Many modern, synthesizer-based transmitters can directly lock to the precision disciplined 10-MHz source, while older units usually require references at either1 e, 2 e, or 4 e the final frequency. In these latter cases, the existing transmitter crystal can usually be satisfactorily pulled via injection locking. The effectiveness of the synchronization concept to reduce interference effects was demonstrated in a laboratory test setup. Many hours of careful subjective listening were conducted, with the two interfering units both precisely on-frequency with the main unit (synchronous operation) and with the two interferers at various frequency offsets, from below 1 Hz to above 10 Hz.

42 ENGINEERING↗

Design of the stift time and frequency transfer microwave ground terminal

The Satellite Time and Frequency Transfer System is intended to provide, simultaneously, global time comparisons at the subnanosecond level and frequency comparisons to better than 1 part in 10 to the 14th power. It utilizes an orbiting hydrogen maser clock and frequency standard that communicates, via microwave links, time and frequency information to Earth terminals operated by hydrogen masers controlling local clocks. A two-way microwave link, to and from the space vehicle provides Doppler information used to cancel the Doppler shifts in a one-way link from the spaceborne oscillator. Pseudo-random noise (PRN) modulation in the two-way link also provides range information to cancel the range delay in the PRN time transfer between space and Earth. The pseudo-random noise modulation system for time difference measurement and its incorporation in the Doppler cancellation system for frequency comparison is explained. The particular PRN code sequence selected and an analysis of the system is discussed.

Penfield, H.↗

Linear Ion Trap For Atomic Clock

Linear, radio-frequency ion trap increases frequency stability of atomic frequency standard device. Confines ions with less radio-frequency motion than does point ion trap.

Prestage, John D.↗

Allan deviation computations of a linear frequency synthesizer system using frequency domain techniques

Allan Deviation computations of linear frequency synthesizer systems have been reported previously using real-time simulations. Even though it takes less time compared with the actual measurement, it is still very time consuming to compute the Allan Deviation for long sample times with the desired confidence level. Also noises, such as flicker phase noise and flicker frequency noise, can not be simulated precisely. The use of frequency domain techniques can overcome these drawbacks. In this paper the system error model of a fictitious linear frequency synthesizer is developed and its performance using a Cesium (Cs) atomic frequency standard (AFS) as a reference is evaluated using frequency domain techniques. For a linear timing system, the power spectral density at the system output can be computed with known system transfer functions and known power spectral densities from the input noise sources. The resulting power spectral density can then be used to compute the Allan Variance at the system output. Sensitivities of the Allan Variance at the system output to each of its independent input noises are obtained, and they are valuable for design trade-off and trouble-shooting.

Wu, Andy↗

Two-frequency sub-Doppler spectroscopy of the caesium D{sub 1} line in various configurations of counterpropagating laser beams

Sub-Doppler resonances in caesium vapours are studied in a laser field produced by counterpropagating two-frequency light beams with mutually orthogonal linear polarisations. The beams are in resonance with optical transitions in the D{sub 1} line, the frequency difference of the field spectral components being equal to the hyperfine ground-state splitting in the Cs atom (∼9.2 GHz). It has already been shown that in this configuration, the hypercontrast effect can be observed for sub-Doppler resonances, which makes this configuration promising for the employment in new-generation miniature optical frequency standards. In the present work, two different two-frequency configurations are compared with each other and with the single-frequency configuration widely used in practice for observing saturated absorption resonances. The parameters of nonlinear resonances are measured at various temperatures of caesium vapours and at different optical field intensities. The results of the investigations performed make it possible to find an optimal two-frequency scheme for exciting nonlinear resonances and to estimate a potential of the scheme for its applications in quantum metrology. (laser spectroscopy of atoms)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 100-kHz frequency divider, distribution amplifier

A frequency divider, distribution amplifier module having low phase noise and low phase drift with temperature and high isolation between outputs was developed for use in the hydrogen maser frequency standard, where it divides 1 MHz from the previous frequency divider down to 100 kHz and provides four transistor-transistor logic (TTL) outputs.

Lutes, G.↗

Highly Stable Microwave Resonator

Superconducting walls on sapphire-filled cavity make low-loss device. Improved microwave resonant cavity consists of sapphire cylinder coated with thin film of superconducting lead. Operated well below superconducting transition temperature at 1.5K, cavity demonstrated superior frequency stability and quality factor. Cavity frequency highly stable and therefore suitable for use in standard frequency generators and filters.

Strayer, Donald M.↗

Nonlinear optical higher-order effects in an optical lattice clock

The development of optical frequency standards with a relative uncertainty of reproducing the time and frequency units at a level as low as 10{sup −17}–10{sup −18} calls for an unprecedented accuracy in estimating the role of higher orders of optical nonlinearity, caused by the influence of the optical lattice on the frequency shift of the ‘clock transition’. This paper presents a systematic calculation of the contributions of multipole nonlinear anharmonic effects to the error of clocks based on optical lattices for alkaline-earth-like Sr, Yb, and Hg atoms. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designing for Flight Through Periods of Instability

For completeness, it is imperative that Flight Control System (FCS) designers use both complementary time and frequency domain techniques to address periods of instability. Use of standard frequency domain synthesis techniques alone may not always yield an FCS design with sufficient gain and phase stability robustness margins while simultaneously satisfying performance requirements.

Designing for Flight↗

Unprecented syntonization and syncronization accuracy via simultaneous viewing with GPS receivers: Construction characteristics of an NBS/GPS receiver

The National Bureau of Standards/Global Positioning System (NBS/GPS) receiver is discussed. It is designed around the concept of obtaining high accuracy, low cost time and frequency comparisons between remote frequency standards and clocks with the intent to aid international time and frequency coordination. Preliminary tests of this comparison technique between Boulder, CO and Washington, D.C indicate the ability to do accurate time transfer to better that 10 ns, and frequency measurements to better than 1 part in 10 to the 14th power. The hardware and software of the receiver is detailed. The receiver is fully automatic with a built-in 0.1 ns resolution time interval counter. A microprocessor does data processing. Satellite signal stabilities are routinely at the 5 ns level for 15 s averages, and the internal receiver stabilities are at the 1 ns level.

Davis, D. D.↗

A hydrogen maser with cavity auto-tuner for timekeeping

A hydrogen maser frequency standard for timekeeping was worked on at the Shanghai Observatory. The maser employs a fast cavity auto-tuner, which can detect and compensate the frequency drift of the high-Q resonant cavity with a short time constant by means of a signal injection method, so that the long term frequency stability of the maser standard is greatly improved. The cavity auto-tuning system and some maser data obtained from the atomic time comparison.

C. F. Lin↗