Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fast Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found.

Dudkin, V. E.↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

Optical Imaging of Laser-Driven Fast Electron Weibel-like Filamentation in Overcritical Density Plasma

We report on the measurement of filamented transport of laser-generated fast electron beams in near-critical density plasma. A relativistic intensity long-wave-infrared laser irradiated a hydrodynamically shaped helium gas flow at an electron density n e ≃ 10 25 m − 3 , generating a large flux of fast electrons that propagated beyond the critical surface. The beam-to-background electron density ratio was sufficiently high to drive growth of Weibel-like filamentation, which was measured by optical probing to extend up to 800 μ m with radii ∼ 10 μ m . Particle-in-cell simulations reproduce the main features of the filamentation generation, suggesting that collisionless processes are dominant in these interactions. Expansion of the filaments after formation infers a fast electron heated plasma temperature ∼ 400 eV in the overcritical density plasma. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Miniature Convection Cooled Plug-type Heat Flux Gauges

Tests and analysis of a new miniature plug-type heat flux gauge configuration are described. This gauge can simultaneously measure heat flux on two opposed active surfaces when heat flux levels are equal to or greater than about 0.2 MW/m(sup 2). The performance of this dual active surface gauge was investigated over a wide transient and steady heat flux and temperature range. The tests were performed by radiatively heating the front surface with an argon arc lamp while the back surface was convection cooled with air. Accuracy is about +20 percent. The gauge is responsive to fast heat flux transients and is designed to withstand the high temperature (1300 K), high pressure (15 MPa), erosive and corrosive environments in modern engines. This gauge can be used to measure heat flux on the surfaces of internally cooled apparatus such as turbine blades and combustors used in jet propulsion systems and on the surfaces of hypersonic vehicles. Heat flux measurement accuracy is not compromised when design considerations call for various size gauges to be fabricated into alloys of various shapes and properties. Significant gauge temperature reductions (120 K), which can lead to potential gauge durability improvement, were obtained when the gauges were air-cooled by forced convection.

Liebert, Curt H.↗

Measurement of spectra and neutron fluxes on artificial earth satellites from the Cosmos series

In 1966-1967 measurements were carried out at the altitudes of 200 to 400 km to determine the spectra and fluxes of fast neutrons inside the hermetically sealed artificial earth satellites of the Cosmos series. The detectors used were nuclear emulsions of the B9 and BR types and an emulsion of the P9 type, filled with Li and P. Spectra and fluxes of neutrons in the range of energies from thermal energies to 10 MeV are presented. Neutron doses are also estimated.

Dudkin, V. Y.↗

Advancing Core Safety of Gen IV and Gen IV + Reactors by Encompassing High-Temperature Resistant Materials - 18673

The paper focuses on the development of materials for Gen IV/IV+ reactor core. It discusses the advancement of materials studied and their application in different components of the reactor core and other auxiliary components which will help in the development of future generation reactors. The paper summarizes the material study showing the characteristic behavior of different materials (coated with FeB and FeB{sub 2}), towards irradiation at near high temperatures and high energy neutron flux condition. The project includes different materials which are coated on the boundaries with varied thickness of FeB and FeB{sub 2}. The samples included Carbon steel, Stainless steel 310, Stainless steel 316, Inconel 718. All above-mentioned samples were received by Prof. J. Szpunar, through an industry with coatings of FeB and FeB{sub 2} with varied thickness along with a bare sample of each material. The samples were irradiated at the University of Saskatchewan reactor, with fast neutron flux of 1.1x10{sup 11} n.cm{sup -2}.sec{sup -1}. I worked on all the samples but the paper particularly focuses on, two carbon steel samples results, received so far. The methodology for the project been followed for all the samples is as follow: 1. Received samples were first polished. 2. Vickers Hardness Test. 3. Mirror polished. 4. Etched with the appropriate etchant for the material. 5. Microscopic study of the etched surface. 6. SEM imaging. 7. Sent for irradiation. 8. The same set of material testing done after irradiation, with an EBSD run on the boundary and main surface. The two Carbon Steel samples (sample 21 and 19) analyzed, were irradiated for 14 hrs. Sample 21 was a bare sample and sample 19 had a coating of FeB, FeB{sub 2} with a ∼0.0010'' thickness. The methodology was followed for material testing before and after the irradiation. The advantage of FeB and FeB{sub 2} coatings are: 1. Higher hardness - 10 times (FeB-1775 and FeB{sub 2}-1450), 2. High-stress capacity, 3. Lower abrasion, 4. Low corrosion. Through the test results obtained before and after the irradiation, I was able to get a view of coating damage at the boundaries of sample 19. The bare sample don't show any difference after irradiation but the coated sample do show cracks in the FeB layer. Which can be seen in the SEM images of sample 19. The hardness results are promising, as hardness didn't change significantly. The hardness test was done on the substrate as the coating was significantly narrow to perform the test. Though the hardness test on coatings was performed by the possessor company which show hardness higher by a factor of 10 when compared to uncoated surfaces. The XRD results, reveal irradiation effect on the crystal lattice, making it deformed, which though is usual during irradiation. The overall analysis along with EBSD done on the two samples are favorable and promising. Though it still needs to be cleared out, whether the cracks on the coating were due to irradiation or due to etching after the samples were irradiated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of neutron spectra in the experimental reactor LR-0

The measurement of fast neutron fluxes is important in many areas of nuclear technology. It affects the stability of the reactor structural components, performance of fuel, and also the fuel manner. The experiments performed at the LR-0 reactor were in the past focused on the measurement of neutron field far from the core, in reactor pressure vessel simulator or in biological shielding simulator. In the present the measurement in closer regions to core became more important, especially measurements in structural components like reactor baffle. This importance increases with both reactor power increase and also long term operation. Other important task is an increasing need for the measurement close to the fuel. The spectra near the fuel are aimed due to the planned measurements with the FLIBE salt, in FHR / MSR research, where one of the task is the measurement of the neutron spectra in it. In both types of experiments there is strong demand for high working count rate. The high count rate is caused mainly by high gamma background and by high fluxes. The fluxes in core or in its vicinity are relatively high to ensure safe reactor operation. This request is met in the digital spectroscopic apparatus. All experiments were realized in the LR-0 reactor. It is an extremely flexible light water zero-power research reactor, operated by the Research Center Rez (Czech Republic). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ITER Neutronic Challenges for Upper Port 14

The future of magnetically confined nuclear fusion facilities is extremely promising, yet there are extensive challenges that still have to be addressed. These challenges range significantly, but one of the more difficult challenges is nuclear shielding and nuclear safety. The challenge of adequately shielding neutrons is especially prevalent at ITER. Throughout the lifetime of ITER there will be large quantities of high energy (14.1- MeV) neutrons generated, with the expected neutron lifetime fluence to be around 0.3 MW.a/m{sup 2}. For such a large neutron fluence, shielding is a very important factor for the operation of ITER. Not only the shielding of the people that will be supporting the facility, but also to the components that surround the plasma. Without the many diagnostics that are planned for ITER operation, ITER would not be able to function. But with the inclusion of the diagnostics and the many apertures required, an interesting neutronics environment is created. This environment is like nothing we have seen or are currently able to create on the earth. Due to this unknown, significant time and effort is being placed on the research, design, and analysis of the ITER neutronics environment. A neutron has an interesting life after birth within the plasma on ITER. There are many different paths and reactions that can take place; so many, that trying to simplify the problem has brought significant unknowns into the analysis. Due to unique material compositions, neutron streaming paths, and neutronics requirements, the simplest of ITER neutronics calculations have to be thought out in great detail. Placing a new hole for a diagnostic creates a new streaming path; internal components must survive a high fast neutron flux, while external components face a completely different neutron energy spectrum of a high flux; material activation within human accessible areas must be maintained to an allowable level. As the complexity of the ITER device grows, so does the complexity of the neutronics challenges.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

Study of the Radiation Resistance of Endohedral Fullerenes of Rare-Earth Elements and Their Water-Soluble Derivatives

Endohedral metallofullerenes Me@C{sub 2n} (n = 30–50), their hydroxylated derivatives Me@C{sub 2n}(OH){sub 38–40} (Me = Tm, Ho, Eu, Sm, Co), and fullerenol С{sub 60}(OH){sub 38} have been synthesized The radiation resistance of these structures under irradiation in reactor by thermal and fast neutron fluxes in the fluence range of 1018–1019 cm{sup –2} (cadmium ratio of ~10) has been analyzed. Endofullerenols are shown to be more stable in comparison with initial endohedral fullerenes; the molecules containing Eu and Sm (atoms characterized by the largest slow-neutron absorption cross section) turned out to be most stable. The mechanism of the formation of secondary Eu and Sm endofullerenols is discussed taking into account the neutron capture and emission of γ quanta by excited nuclei, which acquire the recoil energy.

36 MATERIALS SCIENCE↗

Post Irradiation Examination of Fast Neutron Irradiated 14YWT Tubes at Nuclear Science User Facilities

Cladding materials for next generation nuclear reactors require resistance to high doses of fast neutron flux. Work through the Department of Energy's (DOE) Nuclear Technology Research and Development (NTR and D) Program's Advanced Fuel Campaign has identified 14YWT, a nano-ferritic oxide dispersion strengthened alloy as a promising alloy and has made a 50 kg batch of material, FCRD-NFA1, with nominal composition Fe-14Cr-3W0.4Ti-0.2Y in weight percentage. Plates were extruded from milled powder at Oak Ridge National Laboratory and then electro-discharge machined (EDM) into two sizes of tubes at Los Alamos National Laboratory (LANL). The OD of the tubes were polished to remove the EDM recast layer. Twenty-four of these tubes were placed into the BOR60 reactor, a sodium fast reactor, at the RIAR lab in Dimitrovgrad Russia. Irradiation conditions depended on exact location within the reactor, but the two samples in this study (L108 and L202) were irradiated to 7 dpa at 360-370 deg. C (Sample L108), and 6 dpa at 385-430 deg. C (L202). More detailed temperature models are pending for sample L202. Post irradiation examination took place at both LANL and the University of California, Berkeley (UCB). Facilities used at LANL (CMR Wing 9 Hot Cells, Electron Microscopy Lab (EML)) are part of a pending NSUF partner facility application, while the work at UCB was completed under a Nuclear Science User Facility, Rapid Turnaround Experiment Proposal (NSUF-RTE)

36 MATERIALS SCIENCE↗

Energetic ion fluxes in the inner coma of Comet P/Halley

The particle phenomenon observed inside the magnetic field-free cavity near the nucleus of Comet P/Halley by the Giotto Ion Mass Spectrometer High-Energy Range Spectrometer sensor is studied. The question of access to the cavity of particles ionized farther out in the coma is addressed. A quantitative model of a mechanism for creating the observed fast-ion fluxes in the cavity is presented.

Eviatar, Aharon↗

Accident Tolerant Fuel Test (ATF-2c) Irradiation Test Report

A new fully prototypic testing platform for testing new accident tolerant fuel (ATF) designs for light water reactors has been established in the center flux trap of Idaho National Laboratory’s advanced test reactor (ATR). The irradiation experiment named ATF-2C has completed its first cycle of prototypic steady state irradiation. Irradiation conditions have been maintained via the loop 2a pressurized water coolant loop and have been monitored through in-situ instrumentation during each cycle. Power and fast neutron flux histories of each of the 24 test pins has been calculated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Detection via the Cherenkov Effect

We have incorporated neutron-absorbing elements in transparent, nonscintillating glasses and used the Cherenkov effect to convert neutron-induced beta-gamma radiation directly into light. Use of the Cherenkov effect requires glasses with a high index of refraction (to lower the threshold and increase the number of Cherenkov photons) and neutron absorbers resulting in radioactive products emitting high-energy beta or gamma radiation. In this paper, we present a brief description of the requirements for developing efficient Cherenkov-based neutron detectors, show the results of measurements of the response of representative samples to thermal and fast neutron fluxes, and give the results of a calculation of the expected response of a detector to a moderated fission spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some features of the small-scale solar wind fluctuations

We have investigated small-scale variations of the solar wind ion flux measured with Faraday cups onboard the Prognoz-8 satellite. These measurements have a high time resolution of 1.24 seconds for intervals with a duration of several hours and as high as 0.02 seconds for some periods of about 1 hour duration. The main goal of this work is the determination of the quantitative features of fast ion flux fluctuations using mainly spectral analysis but also other methods. We also identify their association with interplanetary plasma parameters. Particularly, it is shown that the slope of the power spectra in the frequency range from 1E-4 to 6E-2 Hz is close to the classical Kolmogorov (-5/3) law. We also discuss some intervals with a very high level of the relative amplitude of flux fluctuations (10-20 percent) which were observed near the Earth's bow shock in the foreshock region. The use of the wavelet method for the long time series allows us to study the temporal evolution of power spectra.

Zastenker, G.↗

VCTR: A Versatile Coupled Test Reactor Concept

The United States has currently no domestic fast neutron test and irradiation capabilities necessary to pursue a strong research and development program related to fast neutron reactors. This lack prevents the testing of fast reactor fuels in a prototypic environment, the testing of new safety features and of new coolants. A new irradiation test reactor is a costly investment that will operate for several decades and the initial specifications are crucial to ensure the relevance of such a facility in the long run. This new test reactor should be highly reconfigurable and allow operation as a fast test reactor or a thermal test reactor or a cou-pled fast-thermal test reactor. This report presents the on-going effort at Idaho National Laboratory (INL) to design a versatile coupled test reactor (VCTR—pronounced Victor) that could fulfill the R&D needs requiring high fast neutron fluxes but also high thermal neutron fluxes in configurations that could not be met in current thermal neutron test reactors such as ATR. The objective of this report is to summarize the efforts undertaken at INL from May 2015 to March 2016 aimed at understanding the main options for designing and building a versatile test reactor, with a primary mission to provide thermal and fast neutrons for irradiation of fuels and materials in a manner complementary to the ATR and HFIR reactors. Other missions can also be considered, including the validation of computer codes and the development of specific reactor technologies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical and X-ray radiation from fast pulsars - Effects of duty cycle and spectral shape

The optical luminosity of PSR 0540 is considerably stronger than what one would have predicted in a simple model developed earlier where the pulses are synchrotron radiation by secondary electrons near the light cylinder. This discrepancy can be eliminated if one incorporates into the model the effects of the large duty cycle and the spectral properties of PSR 0540. It is also shown that the same model can provide a reasonable fit to the observed X-ray fluxes from fast pulsars.

Pacini, F.↗